Loading...
2001-12-03 Permit Application: 01010573 ResidenceProject Number: 01010573 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 12/3/01 Page 1 of 3 Project htfornnation: Permit Use: RESIDENCE W /GARAGE - GAS Setbacks: Front 43 Left: 35 Right: 25 Rear: 10 Site Information: Plat Key: 006113 Name: TURTLE CREEK 3RD ADDITION Contact: HAIDER, ALEX Address: 17503 N KIMBERLY RD C - S - Z: COLBERT WA 99005 Phone: (509) 468 -1613 Group Name: Project Name: Parcel Number: 55194.1208 Block: 2 Lot: 8 SiteAddress: 920 S BEIGE RD GREENACRES, WA USA 9901 Location:: GRE District: G Owner: Name: HAIDER, ALEX Address: 17503 N KIMBERLY RD COLBERT WA 99005 Zoning: UR -3.5 Urban Residential 3.5 Water District: 008 CONSOLIDATED IRRG #1 Hold: ❑ Area: 11,164 Sq Ft Width: 90 Depth: 125 Right Of Way (ft): 50 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Review Site Plan Review Plan Review Approach / Drainage ReleasedBy Or A-004331 Landuse /Zoning /i Released By: 4 Released By: IReleased By: Sewer Review / etrki cci a Released By: O ILLrI -i oSe-22-p Operator: JAS Printed By: JAS Print Date: 12/3/01 1 Project Number: 01010573 Permits: Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 12/3/01 Page 2 of 3 Contractor: ALEX HAIDER CONSTRUCTION Address: 17503 N KIMBERLY RD COLBERT, WA 99005 Const Category: New Nbr Of Dwellings: 1 Occupant Load: Bldg W x D: 30 Req Parking: Handicap Parking: Building Permit Firm: ALEX HAIDER CONSTRUCTION Phone: (509) 468 -1613 Building Characteristics Group: R -3 Type: VN Building Height: 16 2440 Sprinklers: El Critical Materials: ❑ This Application: Sq Ft Valuation 200 $3,152.00 1,000 $11,560.00 80 $588.80 600 $7,200.00 1,240 $76,880.00 x 72 Building Sq Ft: Description Grp Type Notes BASEMENT F R -3 VN BASEMENT U R -3 VN DECK R -3 VN GARAGE U -1 VN RESIDENCE R -3 VN Item Description RESIDENTIAL VALUATION STATE SURCHARGE RESIDENTIAL SURCHARGE Stories: 1 Total Project: Sq Ft Valuation 200 $3,152.00 1,000 $11,560.00 80 $588.80 600 $7,200.00 1,240 $76,880.00 Totals: 3,120 $99,380.80 Units Unit Desc 1 Y OR BLANK 1 Y OR BLANK 1 Y OR BLANK Permit Total Fees: Mechanical Permit Contractor: R & R HEATING & AIR COND INC Address: 4019 E CENTRAL SPOKANE, WA 99207 Item Description GAS WATER HEATER GAS APPLIANCE <= 100,000BTU GAS PIPING VENTILATING FANS CLOTHES DRYER RANGE GAS LOG OR GAS INSERT HOOD -TYPE II Units 1 1 5 3 1 1 1 1 Operator: JAS Printed By: JAS 3,120 $99,380.80 Fee Amount $892.50 $4.50 $196.35 $1,093.35 Firm: R & R HEATING & AIR COND INC Phone: Unit Desc NUMBER OF NUMBER OF # OF UNITS NUMBER OF NUMBER OF NUMBER OF NUMBER OF NUMBER OF Permit Total Fees: (509) 484 -1405 Print Date: Fee Amount $10.00 $12.00 $5.00 $30.00 $10.00 $10.00 $10.00 $10.00 $97.00 12/3/01 Project Number: 01010573 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 12/3/01 Page 3 of 3 Contractor: JACKSON PLUMBING Address: P.O. BOX 7272 SPOKANE, WA 99207 Item Description TOILETS /BIDETS SINKS SHOWERS TUBS DISH WASHERS GARBAGE DISPOSAL CLOTHES WASHER FLOOR DRAINS WATER USING DEVICES Plumbing Permit Firm: RANDY JACKSON PLUMBING Phone: (509) 926 -7101 Units Unit Desc 2 NUMBER OF 3 NUMBER OF 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 2 NUMBER OF Fee Amount $12.00 $18.00 $6.00 $6.00 $6.00 $6.00 $6.00 $6.00 $12.00 Permit Total Fees: $78.00 Notes: Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $1,093.35 $1,093.35 $0.00 $1,093.35 Mechanical Permit $97.00 $97.00 $0.00 $97.00 Plumbing Permit $78.00 $78.00 $0.00 $78.00 $1,268.35 $1,268.35 $0.00 $1,268.35 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and /or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be contrued to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JAS Printed By: JAS Print Date: 12/3/01 OWNER /APPLICANT INFORMATION El Indiatle who sfiottld he tatladed trsaniiur !big t'refee! ❑ Owner. Phone: / ,5 h &j-C �C'iVA> Fax: ❑ Applic t: le". 7-76J -d'(� Phone: Fax: Mailing Address: / Mailing Address: Fire District Zoning Cit, State, Zip /�/(J, ! �7 �j7 /Ci 'Z Xe G- 4-2/.9: `-' U.> City, State, Zip //J / Garage sq. ft. 6o �= ❑ Contractor / y Phone �Ze -ice. t� ,,/6 I.ax ❑ Architect /Engineer Heat source (clectri _, gas, etc.) '7Ce. S Phone Fax Mailing address (7 5`0 3 /Y. A.---/ 6- iZ /c/ Mailing address City, State Zip _ City, State Zip \W!\ State Con actor license # / WC' At13S /9, Contact name: / VA SPOKANE COUNTY PROJECT APPLICATION WORK SHEET SPOKANE COUNTY DIVISION OF BUILDING & CODE ENFORCEMENT 1026 WEST BROADWAY AVENUE SPOKANE, WA 99260 509- 477 -3675 SPECIFIC SITE INFORMATION Street Address: Assessor's Tax Parcel Number(s): c Legal Description•; . u. 1 Project Description: J Building Permit ❑ Relocation ❑ Change in Use ❑ Grading ❑ Manufactured Home Permit ❑ Sign ❑ Tenant (New /Change) ❑ Other Department Use Only Water District /Purveyor. Sewer District /Purveyor Road width Setbacks Front Rear. Left Right School District Fire District Zoning PROTECT INFORMATION Building Information Building height to peak /G # of stories ,,, l�z Main floor sq. ft. h1 l o / Unfinished basement sq. ft.• 76200 Dimensions ( 3- 72 Total habitable space 2"d floor sq. ft. Finished basement s }a. ft .e ‘,2c-..3 7C. Occupancy group 5.' 4' 7lr `, "'- � Construction n e C -'�/ j%?/ `7 Garage sq. ft. 6o �= Deck sq. ft. 767 Cost of project (7O, Do1>, 0 C) Heat source (clectri _, gas, etc.) '7Ce. S 14.810.100 Rear Yard Where any specified rear yard is required, no building shall be hereafter erected or altered so that any portion thereof may be nearer to the rear lot line than the distance indicated by the depth of the required rear yard. 1. Exceptions: Eaves, cornices, steps, platforms and open porches may extend into the required rear yard for a distance of not more than two (2) feet. The required setback for an attached private garage for single - family and duplex dwellings is five (5) feet per story; b. If on a corner lot a residence maintains the required front yard setback from both the front and flanking streets, the required rear yard shall be that area included within a twenty-five (25)- foot radius measured from the inside lot corner; c. Exceptions for solar developments are provided in Section 14.812.040(2); d. Exceptions for zero -lot -line housing are provided in Chapter 14.814; and e. Structures less than one hundred twenty (120) square feet may be located on the rear lot line. f. See Chapter 14.506 Administrative Exception. 14.810.120 Height of Structures and Roof Structures Penthouses or roof structures for the housing of elevators, stairways, tanks, ventilating fans, or similar equipment required to operate and maintain the building; fire or parapet walls, skylights, flagpoles, chimneys, smokestacks, church steeples and belfries, wireless masts, and similar structures; and silos, barns, windmills, and equipment used in harvesting agricultural and forest products may be erected above the height limits of this Code; provided, however, no penthouses or roof structure, or any other space above the height limit prescribed for the zone in which the building or structure is located, shall be allowed for the purpose of providing additional livable floor area. Section 14.812.040(b) provides for height exceptions for solar energy systems and except that the provisions for height within the Airport Overlay zone shall apply to any structure. 14.810.140 Building Line Variations 1. The Board of County Commissioners on recommendation of the Planning Commission after public hearing with notice as provided in Section 14.402.080 by the Planning Commission may establish a building line or setback along certain streets or property throughout certain zones or throughout certain natural areas other than the line established by the yard requirements specifically provided in this Code when it is found that to do so will protect the public health, safety and welfare. Such building line or setback shall be identified on a plan and, if adopted, shall be placed on the Official Zoning maps. 2. Where there is an established building line in a B-1, B -2, B-3, I -2 or I -3 zone, a commercial or industrial building may be built on the established building line. The established building line can not be determined by a single existing structure, but rather shall be determined by the setback of at least two existing structures constituting a minimum of sixty-five percent (65 %) of the existing structures three hundred (300) feet in each direction on the same side of the street in the same block as the proposed building. 14.810.160 Canopies 1. Any service station, drive -in restaurant or drive -in bank canopy may extend into the front or flanking street yards provided that: a. the canopy is cantilevered or projected from the building, support columns are located in the service islands or support columns are no greater than two (2) feet in any horizontal dimension; b. no such canopy shall extend closer than five (5) feet to any property line; 2. Any other nonresidential canopy which is cantilevered or projected from a building may extend into the front or flanking street yards provided that: Chapter 14.810 Zoning Code Printed: November 1998 Page 366 of Spokane County 1 ■ 7/51/Pt o I2 . oO 90 9,°ter 9(‹.s tt), vz. 2 r3,M -) C' i. l 1 CoQ C�-E 12 110 ‘k-f Thls site plan Is bonsubmitted for thepurpose of btaining a building permit and is a true and cc -rect resentatton of the proposal, All known prop rty line dimensions, curb lines. structures and easements have . n identified. Also indicated are wetlands, bodies of slo ;e f n` {'C7{ arCLa. Signed: /r Date: 1.1