Loading...
2008, 05-09 Permit App: 08001712 Residence W/Garage'11 ock k,;q. Permit Center rPIZ ane 11707 E Sprague Ave, Suite 106 �e �T Spokane Valley, WA 99206 (509)688 -0036 FAX: (509)688 -0037 Community Development www.spokanevallev.org.com Re; identiai Construction Permit Application KN1ew Construction ❑ Accessory Bldg ❑ Additionfiternodeil ❑ Deck ❑ Other: SITE ADDRESS /�ql, �_ nit; ASSESSORS PARCEL NO: LEGAL DESCRIPTION: 1_01- gilc L;r6-4 A lw,t,/ Building owner Name: )io, yhO/t d ZoC R (o)#S f. Address: City: Zip: Phone: Fax: contact Person Name: Pau Phone: 2„1 Yg241 Describe the scope of work in detail: ai id a SP'IZ on actor Name: i a -wit , d Sf, Address: 7,60 Z i(L S ; i / / ! I/ Cs ,1 12 01 City: SPo nL or Zip: 99 ZIL, Phone: q 2 ld - 31 6/ Fax: q 2c,- $n q q Lic No: Exp. Date: City Business Lic No: Cost of Project: $ 70, 000 * * * * * * * * * * * ** *The following MUST be complete: (write N/A if not applicable ) * * * * * * * * * * * * * * * * * * * * ** HEIGHT TO PEAK: 24 MAIN FLOOR TO SQ. FTG: y FINISHED BASEMENT SQ. FTG: —' # OF BEDROOMS: DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is /will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this applicatioi an be processed. DIMENSIONS: 2"" FLOOR SQO FTG: # OF STORIES: UNFIN BASEMENT SQ. FTG: GARAGE SQ. FAG CONSTRUCTION TYPE: C/97 DECK/COV. PATIO SQ. FTG: X00 HEAT SOURCE: Nciturct( %as Pur,Lace TOTAL HABITABIE�� i'igr IMPERVIOUS SURFACE AREA: 30% SLOPES ON PROPERTY: Mit SEWER OR SEPTIC? Signature _ Date Method of Payment: (Faxed permit applications will only be accepted with major bankcard) ❑ Cash ❑ Check ❑ Mastercard ❑ VISA Bankcard #: Expires: VIN #: Authorized Signature: REVISED 8/25/2005 ❑ Other Project Number: 08001712 Inv: 1 Application Date: 5/9/2008 Page 1 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project In formation: ®, Ft:*�......"-°''.5,�#•e °.'.,`. ✓as=.. ."a,...e °v"_�.",M.w`s+'d -k"14. %�°T a';r T. .:.1,,, ,. .',7Wa7..wra `:Y _ Permit Use: SFR W/ATT GAR Contact: DIAMOND ROCK CONSTRUCTION Address: 2602 N SULLIVAN C-S-Z: SPOKANE VALLEY WA 99216 Setbacks:Front 25 Left: 5 Right: 15 Rear: 24 Phone: (509)218-4924 Group Name: Site In formation: Project Name: Plat Key: Name: Range District: East Parcel Number: 45144.3204 Block: Lot: SiteAddress: 14916 E ALKI LN Owner:Name: DIAMOND ROCK CONSTRUCTIO Address: 2602 N SULLIVAN Location::CSV SPOKANE VALLEY WA 99216 Zoning: CF Community Facilities Water District: 010 VERA Hold: ❑ Area: 6,600 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review In formation: Y � : ... f , _ a .. . . Review Building Plan Review Released Er Originally Released: 5/8/2008 By: tmelbourn Driveway/Approach Released Ni- Originally Released: 5/9/2008 By: jdavis Landuse/Zoning/HE Conditions '1Pafg � Originally Released: 5/7/2008 By: kkendall Sewer Review Released By: Originally Released: 5/6/2008 By: jdavis Operator: JD Printed By: JD Print Date: 5/9/2008 Project Number: 08001712 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 5/9/2008 Page 2 of 3 Building Permit Contractor: DIAMOND ROCK Firm: DIAMOND ROCK CONSTRUCTIO Address: 2602 N SULLIVAN Phone: (509) 924 -8964 SPOKANE VALLEY WA 99216 Building Characteristics Building Height 24 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation 1 &2 FAMILY R -3 VB 1,490 $141,535.10 1,490 $141,535.10 BASEMENT U R -3 VB 1,490 $22,350.00 1,490 $22,350.00 DECK OPEN R -3 VB 100 $1,500.00 100 $1,500.00 GARAGE U -1 VB 440 $8,360.00 440 $8,360.00 Totals: 3,520 $173,745.10 3,520 $173,745.10 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $1,408.15 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW < 7999 SQ FT 1 SELECT $563.26 Permit Total Fees: Mechanical Permit $1,975.91 Contractor: DIAMOND ROCK Firm: DIAMOND ROCK CONSTRUCTIO Address: 2602 N SULLIVAN Phone: (509) 924 -8964 SPOKANE VALLEY WA 99216 Item Description DUCT SYSTEMS GAS WATER HEATER GAS APPLIANCE <= 100,000BTU GAS PIPING VENTILATING FANS CLOTHES DRYER HOOD -TYPE II Units Unit Desc 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 2 # OF UNITS 3 NUMBER OF 1 NUMBER OF 1 NUMBER OF Operator: JD Printed By: JD Fee Amount $10.00 $10.00 $12.00 $2.00 $30.00 $10.00 $10.00 Permit Total Fees: $84.00 Print Date: 5/9/2008 Project Number: 08001712 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 5/9/2008 Page 3 of 3 Plumbing Permit Contractor: DIAMOND ROCK Firm: DIAMOND ROCK CONSTRUCTIO Address: 2602 N SULLIVAN Phone: (509) 924 -8964 SPOKANE VALLEY WA 99216 Item Description Units Unit Desc Fee Amount TOILETSBIDETS 2 NUMBER OF $12.00 SINKS 4 NUMBER OF $24.00 SHOWERS 1 NUMBER OF $6.00 TUBS 2 NUMBER OF $12.00 DISH WASHERS 1 NUMBER OF $6.00 CLOTHES WASHER 1 NUMBER OF $6.00 MISCELLANEOUS FIXTURES 2 NUMBER OF $12.00 Permit Total Fees: $78.00 Notes: NW corner of Progress and Sprague (parent Parcel No. 45144.2145) IS NOT ALLOWED ANY individual freestanding or monument signs for Tract A -E of BSP- 03 -04. See project No. 05- 001343 for multi- business complex sign. (4- 26 -05) KK Progress Elementary parcels 45144.0317 and 45144.1031 have restrictive environmental covenant placed upon them. See building address file for copy of Environmental Covenant. Payment Summary• Permit Type Building Permit Mechanical Permit Plumbing Permit Fee Amount Invoice Amount Amount Paid Amount Owing $1,975.91 $1,975.91 $0.00 $1,975.91 $84.00 $84.00 $0.00 $84.00 $78.00 $78.00 $0.00 $78.00 $2,137.91 $2,137.91 $0.00 $2,137.91 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and /or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 5/9/2008 Sitikane� Valley Site Address: 14916 E ALKI LN Parcel Number: 45144.3204 Zoning: CF Fire District: FD 01 Project Transmittal City of Spokane Valley Community Development Department 11703 E. Sprague Ave, Suite B3 Spokane Valley, WA 99206 Phone: 509.688.0036 Water District: VERA New project ❑ Previous pre -app meeting ❑ Plan revisions LJ Transmittal Date: Tuesday, May 06, 2008 Project Number: 08001712 Applicant: DIAMOND ROCK CONSTRUCTION Owner: DIAMOND ROCK CONSTRUCTION 2602 N SULLIVAN 2602 N SULLIVAN SPOKANE VALLEY WA 99216 SPOKANE VALLEY WA 99216 (509) 218 -4924 e -mail: e-mail: Contact: DIAMOND ROCK CONSTRUCTION Occupant: 2602 N SULLIVAN SPOKANE VALLEY WA 99216 e -mail. (509) 218 -4924 e -mail: Contractor: DIAMOND ROCK CONSTRUCTION Arch / Engineer: 2602 N SULLIVAN SPOKANE VALLEY WA 99216 (509) 924 -8964 e -mail: ECEOWE Project SFR W /ATT GAR Description: Q L D Building Landuse Engineer Utilities Health Fire Dist Assessor APPLICATIO N SITE PLA N PLAN S e Please send all plan review and project comments via e-mail to the highlighted individuals. Spokane Valley® For City Use Onl PLUS Project Number <5, 0\1 \2 Project Address (19 (C 11703 E Sprague Ave Suite B -3 • Spokane Valley WA 99206 509.688.0036 • Fax: 509.688.0037 • permitcenter @spokanevalley.org As part of our on -going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review ➢ Submit complete, accurate plans and documents. Extra time may be required for re- submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date, please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure, you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre - Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re- submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick -up. Information regarding fees and pre - construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE - APPLICANT PINK - BUILDING FILE REV 9/07 O S Scc(e % k-k41. t o c...) Lo f Li 13) 1 iw`1I6( MK; Ln, PLANNING DEPT. APPROVED BY DATE N IIo,00 f WASHINGTON STATE ENERGY CODE TABLE 6 -2 PRESCRIPTIVE REQUIREMENT S °'t FOR GROUP R OCCUPANCY CLIMATE ZONE 2 * Reference Case 0. Nominal R- values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13 %, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R -12, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R -10 insulation. 8. This wall insulation requirement denotes R -19 wall cavity insulation plus R -5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U- factors from Table 10 -6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U- factor of U =0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U- factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. Effective July 1, 2007 34 Option Glazing Area10: % o of Floor Glazin U- Factor s Door U- Factor Ceiling2 Vaulted Ceiling Wall 12 Above Grade ll. Wa a int Below Grade Wall• a ext Below Grade Floors Slab 6 on Grade Vertical t1 Overhead I. 12% 0.35 0.58 0.20 R -38 R -30 R -21 int' R -21 R -12 R -30 R -10 II.* 15% 0.35 0.58 0.20 R -38 R -30 R -19 + R -58 R -21 R -12 R -30 R -10 III. 17% 0.32 0.58 0.20 R -38 R -30 R -19 + R -58 R -21 R -12 R -30 R -10 IV. 25% Group R -1 and R -2 Occupancies Only 0.35 0.58 0.20 R -38 / U.031 R -30 / U =0.034 R -21 int" / U�.054 R -15 R -12 R -30 / U =0.029 R -10 / F =0.54 V. Unlimited Group R -3 and R-4 Occupancies Only 0.35 0.58 0.20 R -38 R -30 R -19+ R -58 R -21 R -12 R -30 R -10 VI. Unlimited Group R -3 and R-4 Occupancies Only 0.30 0.58 0.20 R-49 or R -38 Adv R -38 R -21 int7 R -21 R -12 R -30 R -10 VII. Unlimited Group R -1 and R -2 Occupancies Only 0.32 0.58 0.20 R -38 / U =0.031 R -30 / U =0.034 R -21 int" / U =0.054 R -15 R -12 R -30 / U =0.029 R -10 / F =0.54 * Reference Case 0. Nominal R- values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13 %, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R -12, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R -10 insulation. 8. This wall insulation requirement denotes R -19 wall cavity insulation plus R -5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U- factors from Table 10 -6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U- factor of U =0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U- factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. Effective July 1, 2007 34 R602.10.6.2 Alternate braced wall panel adjacent to a door or window opening. Alternate braced wall panels constructed in accordance with one of the following pro- visions are also permitted to replace each 4 feet (1219 mm) of braced wall panel as required by Section R602.10.4 for use adjacent to a window or door opening with a full- length header: 1. In one -story buildings, each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 3/8-inch- minimum - thickness (10 mm) wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure R602.10.6.2. The wood structural panel sheathing shall extend up over the solid sawn or glued - laminated header and shall be nailed in accordance with Figure R602.10.6.2. Use of a built -up header consisting of at least two 2 x 12s and fastened in accordance with Table R602.3(1) shall be permitted. A spacer, if used, shall be placed on the side of the built -up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full - length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than 6 feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1000 pounds (4448 N) shall fasten the header to the side of the inner studs opposite the sheathing. One anchor bolt not less than 5/8- inch - diameter (16 mm) and installed in accordance with Section R403.1.6 shall be installed in the center of each sill plate. The studs at each end of the panel shall have a tie -down device fastened to the foundation with an uplift capacity of not less than 4,200 pounds (18 683 N). Where a panel is located on one side of the open- ing, the header shall extend between the inside face of the first full- length stud of the panel and the bear- ing studs at the other end of the opening. A strap with an uplift capacity of not less than 1000 pounds (4448 N) shall fasten the header to the bearing studs. The bearing studs shall also have a tie -down device fastened to the foundation with an uplift capacity of not less than 1000 pounds (4448 N). EXTENT OF HEADER DOUBLE PORTAL FRAME (TWO BRACED WALL PANELS) EXTENT OF HEADER SINGLE PORTAL FRAME (ONE BRACED WALL PANEL) MAX. HEIGHT 10' • MiN. 3" X 11.25" NET HEADER •1 140 6' TO 18' 1 ROWS OF 16D SINKER NAILS AT 3" O.C. TYP. • • • • FASTEN TOP PLATE TO HEADER WITH TWO 1000 LB STRAP OPPOSITE SHEATHING 1000 LB STRAP FASTEN SHEATHING TO HEADER WITH 80 COMMON OR GALVANIZED BOX NAILS IN 3" GRID PA( I ERN AS SHOWN AND 3° O.C. IN ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. •j• _— MIN. WIDTH = 16° FOR ONE STORY STRUCTURES MIN. WIDTH = 24" FOR USE IN THE FIRST OF TWO STORY STRUCTURES MIN. 2x4 FRAMING 3/8" MIN. THICKNESS WOOD •t STRUCTURAL PANEL SHEATHING MIN. DOUBLE 2x4 POST MIN. 4200 LB TIE -DOWN DEVICE (EMBEDDED INTO I• CONCRETE AND NAILED INTO FRAMING) �I• SEE SECTION fj i�.>LR R62 10 6 2 'H 3czr o 8c, r6 t %N A « The tie -down devices shall be an embedded - strap type, installed in accordance with the manu- facturer's recommendations. The panels shall be supported directly on a foundation which is con- tinuous across the entire length of the braced wall line. The foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12- inch -by -12 -inch (305 mm by 305 mm) continuous footing or turned down slab edge is permitted at door openings in the braced wall line. This continuous footing or turned down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous founda- tion located directly under the braced wall line. 2. In the first story of two -story buildings, each wall panel shall be braced in accordance -with Item 1 above, except that each panel shall have a length of not less than 24 inches (610 mm). TYPICAL PORTAL FRAME CONSTRUCTION FOR A PANEL SPLICE (IF NEEDED), PANEL EDGES SHALL BE BLOCKED, AND OCCUR WITHIN 24" OF MID - HEIGHT ONE ROW OF TYP. SHEATHING -TO- FRAMING NAILING IS REQUIRED. IF 2X4 BLOCKING IS USED, THE 2X4'S MUST BE NAILED TOGETHER WITH 3 16D SINKERS MIN. 1000 LB TIE DOWN DEVICE TT ii J. 1: FIGURE R602.10.6.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING 2006 INTERNATIONAL RESIDENTIAL CODE® WALL CONSTRUCTION 16d NAIL AT 12 IN.O.C. 8d NAIL AT 6 IN.O.C. (AU. PANEL EDGES) 16d NAIL AT 12 IN.O.C. For SI: 1 inch = 25.4 mm. Gypsum board nails deleted for clarity. ORIENTATION OF STUD MAY VARY. SEE FIGURE R602.3(2) GYPSUM WALL BOARD INSTALLED IN / ACCORDANCE WITH CHAPTER 7 8d NAIL AT 121N. O.C.ON ALL FRAMING MEMBERS NOT AT PANEL EDGES (a) OUTSIDE CORNER DETAIL WOOD STRUCTURAL PANEL INSTALLED IN ACCORDANCE WITH TABLE R602.3(1) ORIENTATION OF STUD MAY VARY. SEE FIGURE R602.3(2) GYPSUM WALL BOARD INSTALLED IN / ACCORDANCE WITH CHAPTER 7 (INTERIOR) WOOD STRUCTURAL PANEL INSTALLED IN ACCORDANCE WITH TABLE R602.3(11 8d NAIL AT 61■. O.C. ALL FRAMING MEMBERS AT PANEL EDGES AND 12IN. O.C.ON ALL FRAMING MEMBERS NOT AT PANEL EDGES (b) INSIDE CORNER DETAIL FIGURE R602.10.5 TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS STRUCTURAL PANEL SHEATHING; SHOWING REQUIRED STUD -TO -STUD NAILING 1 1 1 FOUNDATIONS TABLE R404.1.1(5) ' CONCRETE FOUNDATION WALLSh, I,j. k MAXIMUM WALL HEIGHT (feet) MAXIMUM UNBALANCED BACKFILL HEIGHT" (feet) MINIMUM VERTICAL REINFORCEMENT SIZE AND SPACING`, d, e, f, 1 Soil classes' and design lateral soil (psf per foot of depth) GW, GP, SW and SP 30 GM, GC, SM, SM -SC and ML 45 SC, ML -CL and inorganic CL 60 Minimum wall thickness (inches) 5.5 7.5 9.5 11.5 5.5 7.5 9.5 11.5 5.5 7.5 9.5 11.5 5 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC PC PC PC PC PC PC PC PC 6 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC PC PCs PC PC #4 @ 35" PCg PC PC 6 PC PC PC PC #5 @48" PC PC PC #5 @ 36" PC PC PC 7 4 PC PC PC PC PC PC . PC PC PC PC PC PC 5 PC PC PC PC PC PC PC PC #5 @47" PC PC PC 6 PC PC PC PC #5 @42" PC PC PC #6 @43" #5 @48" PCs PC 7 #5 @46" PC PC PC #6 @42" #5 @46 '. PCg PC #6@ 34" #6 @48" PC PC 8 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4 @38" PCs PC PC #5 @43" PC PC PC 6 #4 @37" PCg PC PC #5 @37" PC PC PC #6 @37" #5 @43" PCs PC 7 #5 @40" PC PC PC #6 @37" #5 @41" PC PC #6 @34" #6 @43" PC PC 8 #6 @43" #5 @47" PCs PC #6 @34" #6 @43" PC PC #6 @27" #6@ 32" #6 @44" PC 9 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4 @35" PCs PC PC #5 @40" PC PC` PC 6 #4 @34" PCg PC PC #6 @48" PC PC PC #6 @36" #5 @39" PCg PC 7 #5 @36" PC PC PC #6 @34" #5 @37" PC PC #6 @33" #6 @38" #5 @37" PCg 8 #6 @38" #5 @41" PCs PC #6 @33" #6 @38" #5 @37" PCg #6 @24" #7 @39" #6 @39" #4 @48 "" 9 #6 @34" #6 @46" PC PC #6 @26" #7 @41" #6 @41" PC #6 @19" #7 @31" #7 @41" #6 @39" 10 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4 @33" PCs PC PC #5 @38" PC PC PC 6 #5 @48" PCs PC PC #6 @45" PC PC PC #6 @34" #5 @37" PC PC 7 #6 @47" PC PC PC #6 @34" #6 @48" PC PC #6 @30" #6 @35" #6 @48" PCg 8 #6 @34" #5 @38" PC PC #6 @30" #7 @47" #6 @47" PCg #6 @22" #7 @35" #7 @48 " #6 @45 "" 9 #6 @34" #6 @41." #4 @48" PCg #6 @23" #7 @37" #7 @48" #4 @48 "h DR #6 @22" #7 @37" #7 @47" 10 #6 @28" #7 @45" #6 @45" PC DR #7 @31" #7 @40" #6 @38" DR #6 @22" #7 @30" #7 @38" For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa; 1 pound per square foot per foot = 0.157 kPa/mm. a. Soil classes are in accordance with the United Soil Classification System. Refer to Table R405.1 b. Unbalanced backfill height is the difference in height of the exterior and interior finish ground levels. Where there is an interior concrete slab, the unbalanced back - fill height shall be measured from the exterior finish ground level to the top of the interior concrete slab. c. The size and spacing of vertical reinforcement shown in the table is based on the use of reinforcement with a minimum yield strength of 60,000 psi. Vertical rein- forcement with a minimum yield strength of 40,000 psi or 50,000 psi is permitted, provided the same size bar is used and the spacing shown in the table is reduced by multiplying the spacing by 0.67 or 0.83, respectively. d. Vertical reinforcement, when required, shall be placed nearest the inside face of the wall a distance d from the outside face (soil side) of the wall. The distance d is equal to the wall thickness, t, minus 1.25 inches plus one -half the bar diameter, db (d = t - (1.25 + db /2). The reinforcement shall be placed within a tolerance of ± 3/8 inch where d is less than or equal to 8 inches, or ± 1/2 inch where d is greater than 8 inches. e. In lieu of the reinforcement shown, smaller reinforcing bar sizes and closer spacings resulting in an equivalent cross - sectional area of reinforcement per linear foot of wall are permitted. f. Concrete cover for reinforcement measured from the inside face of the wall shall not be less than 3/4 inch. Concrete cover for reinforcement measured from the out- side face of the wall shall not be less than 11/2 inches for No. 5 bars and smaller, and not less than 2 inches for larger bars. g. The minimum thickness is permitted to be reduced 2 inches, provided the minimum specified compressive strength of concrete f,', is 4,000 psi. h. A plain concrete wall with a minimum thickness of 11.5 inches is permitted, provided minimum specified compressive strength of concrete, f , is 3,500 psi. i. Concrete shall have a specified compressive strength of not less than 2,500 psi at 28 days, unless a higher strength is required by note g or h. j. "DR" means design is required in accordance with ACI 318 or ACI 332. k. "PC" means plain concrete. 1. Where vertical reinforcement is required, horizontal reinforcement shall be provided in accordance with the requirements of Section R404.4.6.2 for ICF founda- tion walls. FOUNDATIONS TABLE R404.1.1(5)--continued CONCRETE FOUNDATION WALLS',"' h. A plain concrete wall with a minimum thickness of 11.5 inches is permitted,provided minimum specified compressive strength of concrete,f',is 3,500 psi. i. Concrete shall have a specified compressive strength of not less than 2,500 psi at 28 days,unless a higher strength is required by note g or h. j. "DR"means design is required in accordance with ACI 318 or ACI 332. k. "PC"means plain concrete. 1. Where vertical reinforcement is required,horizontal reinforcement shall be provided in accordance with the requirements of Section R404.4.6.2 for ICF founda- tion walls. R404.4.6.2 Horizontal reinforcement. When verti sal reinforcement is required, ICF foundation walls shall have horizontal reinforcement in accordance with this section.ICF foundation walls up to 8 feet(2438 mm)in height shall have a minimum of one continuous No. 4 horizontal reinforcing bar placed at 48 inches(1219 mm) on center with one bar located within 12 inches (305 mm) of the top of the wall story. ICF Foundation walls greater than 8 feet(2438 mm)in height shall have a mini- mum of one continuous No.4 horizontal reinforcing bar placed at 36 inches (914 mm) on center with one bar located within 12 inches(305 mm)of the top of the wall story. R404.4.6.3 Wall openings.Vertical wall reinforcement required by Section R404.4.2,R404.4.3 or R404.4.4 that is interrupted by wall openings shall have additional ver- tical reinforcement of the same size placed within 12 inches(305 mm)of each side of the opening. • WALL CONSTRUCTION TABLE R611.7(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD - BEARING WALLS"'`'`“ NO. 4 BOTTOM BAR SIZE MINIMUM LINTEL THICKNESS, T (inches) LINTEL DEPTH, D (inches) MAXIMUM CLEAR SPAN, (feet- inches) (Number is Middle of Span, A)e Supporting Roof Only Supporting Light Framed 2nd Story and Roof Supporting ICF Second Story and Roof Ground Snow Load 30 psf 70 psf 30 psf 70 psf 30 psf 70 psf 3.5 8 4-9 (1 -2) 4-2 (0 -9) 3 -10 (0 -8) 3 -4 (0 -6) 3 -5 (0 -6) 3 -1 (0 -5) 12 6 -8 (1 -11) 5 -5 (1 -3) 5 -0 (1 -1) 4-5 (0 -10) 4 -6 (0 -10) 4 -0 10 -8) 16 7 -11 (2 -9) 6 -5 (1 -9) 6 -0 (1 -6) 5 -3 (1 -2) 5 -4 (1-2) 4 -10 (1 -0) 20 8 -11 (3 -5) 7 -4 (2-3) 6 -9 (1 -11) 6 -0 (1 -6) 6 -1 (1 -7) 5 -6 (1 -3) 24 9-10 (-1-1) 8 -1 (2 -9) 7 -6 (2-4) 6 -7 (1 -10) 6 -9 (1 -11) 6 -1 (1 -6) 5.5 8 5 -2 (1 -10) 4 -2 (1 -2) 3 -10 (1 -0) 3 -5 (0 -9) 3 -5 (0 -10) 3 -1 (0 -8) 12 6-8 (3-0) 5 5 (2 -0) 5-0 (1 -9) 4 -5 (1-4) 4 -6 (1-4) 4 -1 (1-1) 16 7 -10 (4 -1) 6 -5 (2-9) 6 -0 (2 -5) 5 -3 (1 -10) 5-4 (1 -11) 4 -10 (1 -7) 20 8 -10 (5 -3) 7 -3 (3 -6) 6 -9 (3 -1) 6-0 (2 -4) 6-1 (2 -5) 5 -6 (2 -0) 24 9 -8 (6 -3) 8 -0 (4 -3) 7 -5 (3 -8) 6 -7 (2 -11) 6 -8 (3 -0) 6 -0 (2 -5) 7.5 8 5-2 (2 -6) 4-2 (1 -8) 3 -11 (I -5) 3 -5 3-5 (1 -1) 3 -6 3 -2 (1 -1) (0 -11) 12 6 -7 (4 -0) I 5 -5 I (2 -8) 5 -0 1 (2-4) 45 (1 -10) 4 -6 4 -1 (1 -10) (i -6) 16 7 -9 (5 -5) j 6 -5 (3 8) 5 -11 (3 -3) 5 -3 (2 -6) 5 -4 4 -10 (2 -7) (2-2) 20 8 -8 (6 -10) 7 -2 (4-8) 6 -8 (4-2) 5 -11 (3 -3) 6 -0 5 -5 (3 -4) (2 -9) 24 9 -6 (8 -2) 7 -11 (5 -8) 7 -4 (5 -1) 6 -6 (3 -11) 1 6 -7 6M (4 -1) (3 -4) 9.5 8 5 -2 (3 -1) 4 -2 (2 -1) 3 -11 (1 -9) 3 -5 (1 -5) 3-6 (1 -5) 3 -2 (1 -2) 12 6 -7 (5-0) 5 -5 (3 -4) i 5-0 (3 -01 4 -5 (2-4) 4-6 (2 -5) 4 -1 (1 -1I) 16 8 (6-9), 1 6-9 . j ... < (4-7) - , 5-11 (4-2) 5 -3 5-4 �- (3-4) 4 -10 (2 -8) For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kN /m2, 1 pound per square foot = 0.0479 kN /m2. a. This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equivalent rectangular cross section. When reinforcement with a minimum yield strength of 60,000 psi is used, the span lengths in the shaded cells shall be increased by 1.2 times the table values. b. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. c. Deflection criteria: 11240. d. Design load assumptions: Floor dead load is 10 psf Attic live load is 20 psf Floor live load is 30 psf Roof dead load is 15 psf Building width is 32 feet ICF wall dead load is 69 psf Light - framed wall dead load is 10 psf e. No. 3 stirrups are required at d/2 spacing except no stirrups are required for the distance, (A), shown in the middle portion of the span in accordance with Figure R611.7(2) and Section R611.7.3.2. f. Interpolation is permitted between ground snow loads and between lintel depths. 2003 INTERNATIONAL RESIDENTIAL CODE® 173 WALL CONSTRUCTION R611.7.1.3 Horizontal steel. Concrete walls with a screen-grid walls over the length of the opening.When the minimum thickness of 4 inches (102 mm) shall have a depth of concrete above the opening is less than 12 inches minimum of one continuous No.4 horizontal reinforc- for flat or waffle-grid walls,lintels in accordance with Sec- ing bar placed at 32 inches(812 mm)on center with one tion R611.7.3 shall be provided. Reinforcement around bar within 12 inches (305 mm) of the top of the wall openings shall be provided in accordance with Table story. Concrete walls 5.5 inches (140 mm) thick or R611.7(1)and Figure R611.7(2).All reinforcement placed greater shall have a minimum of one continuous No.4 horizontally above or below an opening shall extend a mini- horizontal reinforcing bar placed at 48 inches (1219 mum of 24 inches(610 mm)beyond the limits of the open- mm) on center with one bar located with in 12 inches ing. Wall opening reinforcement shall be provided in (305 mm)of the top of the wall story. addition to the reinforcement required by Sections R611.3, R611.4, R611.5 and R6.11.7.1. The perimeter of all wall For townhouses in Seismic Design Category C, the minimum horizontal reinforcement shall be one No. 5 openings shall be framed with a minimum 2-inch by 4-inch at 24 inches(610 m)on center or one No.4 at 16 inches plate,anchored to the wall with'/Z inch(12.7 mm)diameter (407 mm)on center.For all buildings in Seismic Design anchor bolts spaced a maximum of 24 inches(610 mm)on Categories DI and D2, the minimum horizontal rein- center.The bolts shall be embedded into the concrete a mini- forcement shall be one No.5 at 18 inches(457 mm)on mum of 4 inches(102 mm)and have a minimum of 1'/2(38 mm center or one No.4 at 12 inches(305 mm)on center. )inches of concrete cover to the face of the wall. Horizontal reinforcement shall be continuous around Exception: The 2-inch by 4-inch plate is not required building corners using corner bars or by bending the where the wall is formed to provide solid concrete bars.In either case,the minimum lap splice shall be 24 around the perimeter of the opening with a minimum inches (610 mm). For townhouses in Seismic Design depth of 4 inches(102 mm)for the full thickness of the Category C and for all buildings in Seismic Design Cat- wall. egories Dl and D2,each end of all horizontal reinforce- R611.7.3 Lintels. ment shall terminate with a standard hook or lap splice. R611.7.1.4 Lap Splices.Where lap splicing of vertical R611.7.3.1 General requirements. Lintels shall be or horizontal reinforcing steel is necessary, the lap provided over all openings greater than or equal to 2 feet splice shall be in accordance with Figure R611.7.1.4 (610 mm) in width. Lintels for flat ICF walls shall be and a minimum of 40db,where db is the diameter of the constructed in accordance with Figure R611.7(3) and smaller bar. The maximum distance between Table R611.7(2) or R611.7(3). Lintels for waffle-grid noncontact parallel bars at a lap splice shall not exceed ICF walls shall be constructed in accordance with Fig- 8db, ure R611.7(4)or Figure R611.7(5)and Table R611.7(4) R611.7.1.5 Standard hook.Where the free end of a re- or R611.7(5).Lintels for screen-grid ICF walls shall be constructed in accordance with Figure R611.7(6) or inforcing bar is required to have a standard hook, the Figure R611.7(7). Lintel construction in accordance hook shall be a 180-degree bend plus 4db extension but with Figure R611.7(3) shall be permitted to be used not less than 2V2 inches,or a 90-degree bend plus 12db with waffle-grid and screen-grid ICF wall construction. extension. Lintel depths are permitted to be increased by the height R611.7.2 Wall openings.Wall openings shall have a mini- of the ICF wall located directly above the opening,pro- mum of 8 inches(203 mm)of depth of concrete for flat and vided that the lintel depth spans the entire length of the waffle-grid ICF walls and 12 inches (305 mm) for opening. TABLE R611.7(1) MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLS WALL TYPE AND MINIMUM HORIZONTAL MINIMUM VERTICAL OPENING WIDTH(L)(feet) OPENING REINFORCEMENT OPENING REINFORCEMENT Flat,Waffle-,and Screen-Grid: None required None required L<2(0.61) In locations with wind speeds less than or equal to 110 mph(177 km/hr)or in Seismic Design Categories A and B,provide one No.4 Provide lintels in accordance with Section R611.7.3. bar for the full height of the wall story within 12 inches(305 mm)of Flat,Waffle-,and Provide one No.4 bar within 12 inches(305 mm)from the each side of the opening. Screen-Grid: bottom of the opening.Top and bottom lintel 2(0.61) reinforcement shall extend a inimum of 24 inches(610 In locations with wind speeds greater than 110 mph(177 km/hr), L? m mm)beyond the limits of the opening. townhouses in Seismic Design Category C,or all buildings in Seismic Design Categories D,and D„provide two No.4 bars or one No.5 bar for the full height of the wall story within 12 inches(305 mm)of each side of the opening. For SI: 1 inch=25.4 mm,1 foot=304.8 mm,1 mile per hour=1.609 km/h. NOTE:This table is based on concrete with a minimum specified compressive strength of 2,500 psi,reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equiva- lent rectangular cross section.This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. 172 2003 INTERNATIONAL RESIDENTIAL CODE® WALL CONSTRUCTION TABLE R611.7(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD - BEARING WALLSa,b'o,d,t NO.5 BOTTOM BAR SIZE MINIMUM LINTEL THICKNESS, T LINTEL DEPTH, D MAXIMUM CLEAR SPAN, (feet- inches) (Number is Middle of Span, A)e Supporting Roof Supporting Light Framed 2nd Story and Roof Supporting ICF Second Story and Roof Ground Snow Load 30 psf 70 psf 30 psf 70 psf 30 psf 70 psf (inches) (inches) 3.5 8 4-9 (1 -2) 4 -2 (0 -9) 3 -11 (0 -8) 3 -7 (0 -6) 3 -7 (0 -6) 3 -5 (0 -5) 12 7 -2 (1 -11) 6 -3 (1 -3) 5 -11 (1 -1) 5 -5 (0 -10) 5 -5 (0 -10) 5 -0 (0 -8) 16 9 -6 (2 -9) 8 -0 (1 -9) 7 -4 (1 -6) 6 -6 (1 -2) 6 -7 (1 -2) 5 -11 (1 -0) 20 11 -1 (3 -5) 9-1 (2 -3) a, 8 -4 (1-11) 7-5 (1-6) 7 -6 (1 -7) 6 -9 (1 -3) 24 8 :'. 12 -2 (4-1) 5 -6 (1 -10) 10 -0 (2 -9) 4 -10 (1 -2) 9 -3 (2-4) 4 -7 (1 -0) 8 -2 (1-10) 4 -2 (0 -9) 8-4 (1 -11) - 4 -2 (0 -10) 7 -6 (1 -6) 3 -10 (0 -8) -, 5.5 12 8 -3 (3-0) 6 -9 (2-0) 6 -3 (1 -9) 5 -6 (1 -4) 5 -7 (1 -4) 5 -0 (1 -1) 16 9 -9 (4 -1) 8-0 (2 -9) 7-5 (2 -5) 6-6 (1 -10) 6-7 (1 -11) 6 -0 (1 -7) 20 10-11 (5 -3) 9-0 (3 -6) 8 -4 7 -5 (3-1) (2 -4) 7 -6 6-9 (2 -5) (2-0) 24 12 -0 6 -3) 9 -11 (4 -3) 9 -3 (3 -8) 4 -9 (( -5) 8 -2 8 -3 7 -6 (2 -11) (3 -0) (2 -5) 7.5 8 6 -1 (2 -6) 5 -2 (1 -8) 4 -3 4 -3 (1 -1) (1 -1) 3 -10 (0-11) 12 8 -2 (4 -0) 6 -9 (2 -8) 6 -3 5 -6 5 -7 (2 -4) (1 -10) (1 -10) 5 -0 (1 -6) 16 9 -7 (5 -5) 7 -11 (3 -8) 7 -4 6 -6 6 -7 6 -0 (3 -3) (2 -6) (2 -7) (2-2) 20 10 -10 (6 -10) 8 -11 (4-8) 8 -4 (4-2) 7 -4 7 -6 6 -9 (3 -3) j (3-4) (2-9) 24 11-10 (8 -2) 9 -10 (5 8) 9 -2 (5-1) 8 -1 8 -3 7 -5 (3 -11) (4 -1) (3 -4) 9.5 8 6 -4 (3 -1) 5 -2 (2 -1) 4 -10 (1 -9) 4 -3 4-4 3 -11 (1 -5) (1 -5) (1 -2) 12 8-2 6-8 (5 -0) (3 -4) 6-2 (3-0) 5-6 (2 -4) 6 6 (3 -3) 5 -7 (2-5) 5 -0 (1 -11) 16 9 -6 7 -11 (6 -9) (4 -7) 7-4 (4 -2) 6 -7 (3-4) 5-11 (2 -8) 20 10 -8 8 -10 (8 -4) (5 -10) 8 -3 7 -4 7-5 (5 -4) (4 -2) (4 -3) 6-9 (3 -6) 24 11 -7 9 -9 (10M) i6 -11) 9 -0 8 -1 8 -2 (6 -5) (5 -0) (5 -2) 7 -5� 1473) For SI: 1 inch = 25 4 mm, 1 foot = 304.8 mm, I pound per square inch = 6.895 kN /m', 1 pound per square foot = 0.0479 kN /m'. a. This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equivalent rectangular cross section. When reinforcement with a minimum yield strength of 60,000 psi is used the span lengths in the shaded cells shall be increased by 1.2 times the table values. b. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. c. Deflection criterion: 11240. d. Design load assumptions: Floor dead load is 10 psf Attic live load is 20 psf Floor live load is 30 psf Roof dead load is 15 psf Building width is 32 feet ICF wall dead load is 69 psf Light - framed wall dead load is 10 psf e. No. 3 stirrups are required at d/2 spacing except no stirrups are required for the distance, (A), shown in the middle portion of the span in accordance with Figure R611.7(2) and Section R611.73.2. f. Interpolation is permitted between ground snow loads and between lintel depths. 174 2003 INTERNATIONAL RESIDENTIAL CODE® WALL CONSTRUCTION FIG R611.7(3) FIG MIDDLE OF SPAN, A. NO.4 CONTINUOUS BAR R611.7(4) NOT REQUIRING STIRRUPS AS REQUIRED IN -611.7(5 SEE TABLE R611.7(2), R611.7(3), SECTION R611.7.1 R611.7(4), R611.7(5), OR R611.7(8) TOP OF WALL STORY FIG LINTEL REINFORCEMENT R611.7(6) -511.7(7 AS REQUIRED Z co -LINTEL- i /// I /// /ii i I I L<2' (0.61 m) 24" L ?_ 2' (0.61 m) X24 rr 0.6 m; 0.6 m) OPEN REINFORCEMENT WALL REINFORCEMENT AS REQUIRED PER AS REQUIRED TABLE R611.7(1) FIGURE R611.7(2) REINFORCEMENT OF OPENINGS 1.5 IN.MIN. 2.5 IN.MAX. 14---T A l A ■■i ■■1 -L III Iii ■■1 ■ii NO.4 BAR LINTEL KM NM REINFORCEMENT REQUIRED BM MI ■■M ■■1 SEE TABLE R611.7(2), ■■� ■■1 R611.7(3),R611.7(8), d ■■� ��� MINIMUM NO.3 STIRRUP R611.7(9)OR R611.7(10). D �:; ��; AS REQUIRED MEI MI ■•1 ■■I NMI MI EMI Eon INSULATING FORM ISM NM MI MEI • ■■I •■1 MEI NMI 1.5 IN.MINI. — 2.5 IN.MAX. HORIZONTAL LINTEL REINFORCEMENT AS REQUIRED For SI: 1 inch=25.4 mm. NOTE:Section cut through flat wall. I FIGURE R611.7(3) ICF LINTELS FOR FLAT AND SCREEN-GRID WALLS 186 2003 INTERNATIONAL RESIDENTIAL CODE® 2) #5 rebar o extend 24 riches beyond opening. Reinforcement for openings in plain concrete (2) #5 re beyond op do not re ar to extend ning. Doorway: uire rebar in in bottom of opening. 1909.6.3 Openings in walls. Not less than two No. 5 bars shall be provided around window and door openings. Such bars shall extend at least 24 inches (610 mm) beyond the corners of openings. * All openings for windows and doors in structural plain concrete walls must be bound by two No. 5 (16) bars as follows. For openings not extending to the bottom of the wall, the bars must be placed on all four sides of the opening. For openings extending to the bottom of the wall, the bars are only necessary along the sides and top. To provide continuity at the corners of the openings, the bars must extend 24 inches (610 mm) past the corners. These extensions should occur at all four corners of an opening not extending to the bottom of the wall, and at the two top corners for other openings. city of SPOKANE VALLEY BUILDING DEPARTMENT 11707 E. Sprauge Avenue, 4106, Spokane Valley, Washington 99206 - Tel 509- 921 -1000 - Fax 509- 921 -1008 1 -1/4" to 2" maximum Nosing of trea. 34 " -38" Handrail Return ends to wall, or terminate at newell post Intermediate rail spacing or pattern so that 4 -inch sphere cannot pass through Triangular area formed by tread, riser and guardrail so that 6 in sphere can not pass through REQUIRED WIDTH OF RU N'S HALL 8E PROVIDED INTH IS LO CATION (SECTION 1003.3.3.8.2) `1‘C)3 NOTE: HANDRAILS NOT � Z�`pp3� 5 SHOWN FOR GLARrTY REQUIRED WIDTH OFRUNSHALL BEPROVIDED 1NTHIS LOCATION ECTION 1 DD3.3.3.81) NOTE: HANDRA LS NOT SHOWN FOR CLARITY STAIRWAYWIDTH LIMrTAT1ON: APPLIES TO R -3 OCCUPANCY • (SECTION 1003-33.82) AND PRIVATE STAIRWAYS IN R -1 OCCUPANCY PLAN VIEW WINDING STAIRWAY PLAN VIEW CIRCULAR STAIRWAY WALL. yI`:!::!i@ E! i:!!•,;! p;: L!;i :;:.•!;I ";! +:!};!i;.li! +ti!B!i! PLAN VIEW ALTERNATE USE OF WINDERS MAXIMUTA 91R -NCH RISE BETWEEN TREADS .10 COLUMN z CENTER SUPPORT 7Ir MIN. LIMITATIONS: 1. ONLY APPLIES TO R-3 OCCUPANCY AND PRIVATE STAIRWAYS IN R -1 OCCUPANCIES. 2. IJ141TED TO SERVING AS EXIT FOR 400 SQUARE FEET MAXIMUM_ PLAN VIEW SPIRAL STAIRWAY Stair Dimensions 1 1 1 Width (36" minimun Rise (4" minimum ,8^' maximum) Run (minimum) 1 The greatest riser height within any flight of stairs shall not exceed the samllcst by more than 3/8 ". Stair treads shall bc of uniform size and shape, except the largest tread nun within any flight of stairs shall not cxcccd the smallest by more than 3/8 inch. Handrails osING% —.N "J / " Ansx 1''4" 1 One required (two required if stair is open on sidcs) if there arc four or more risers. 1 Height (34" to 38" above nosing of treads). 1 Projection (1 -1/2 between handrail and wall). 1 Handrails shall be continuous the full length of the stairs. Ends shall bc returned or shall terminate in newel posts or safety terminals. Guardrails 1 Required if 30" or more above grade. 1 Height (36" high at landings - handrail height at steps). 1 Openings (small enough that a 4" diameter sphere an not pass through). ACCEPTABLE SHAPES AND INSTALLATIONS -- HANDRAIL MIN .:: ism;;: 6FKef-.: v::, : :a• ^;::;:w.'.,;tI�L1r, ?-. +!; +: T WALL NOT ACCEPTABLE THE HANDRAIL DETAIL SHOWN HERE DOES NOT COMPLY WITH • THE 'CONTINUOUS TERMINOLOGY IN THE CODE- HANDRAIL CONTINUITY 1 -tp'To r 1'h' 1- 1!'T02 �To 1 -1 /4' 1 Vz TO 2" MIN 3'h" MAX NOTACCEPTABLE NOT ACCEPTABLE rote that while every effort is made to assure the accruacy of the information contained in this brochure it is not warranted for accuracy. ument is not intended to address all aspects or regulatory requirements for a project and should serve as a starting point for your investiga- • detailed information on a particular project, permit, or code requirement refer directly to applicable file and /or code /regulatory documents or he appropriate division or staff. aTi436e3Ritiel30 k.?31403 7,P1Kli14164 3 M00� C4•033110 itan 1334 ' t T331 fiA, . XAM) atil44 - • - • • OG1' .;41.10fs 7.YVA340 iii3e314 • 741044Tryv M.Th Dr IC01413f4i M. ';•".1307- .174';', • 1/117.-; .tolt; I HORHA:) leg * 00tE - 23 DARAi.) .,38A . 4DP0q iA r:41Ckti: AN% i:1.0101 314'1)00 10WORt1 ...;.11! ti Piaa OT .13.iikRAq C:14f.101 C1 !.01M: 3-18tX0 iOPICP-1 Y1.1131-1?')P7 fiiCvU 4A7"k7, • ., . • • u. JIL I Mil SS EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING 1100MS 1) NET CLEAR OPENING 5.7 SQUARE FEET GRADE FLOOR OPENING (MAX 441 5.0 SQUARE FEET 2) NE! rt f AR OOPE NING HEIGHT 24 INCHES 3) NE T CLEAR i.Pt,NING WIDTH 2O INCHES 7 MAX FINtst +ED SILL HEIGHT 44- ABOVE FLOOR E ME R I T! WY ESCAPE & RESCUE OPENING SHALL BE ;;Alit N At )ROM THE INSIDE OF THE ROOM WITHOUT IHI ■SE of ht VS OR TOOLS SMOKE ALARMS SHALL BE INTERCON- NPCTED AND HARD WIRED IN THAT THE ACTIVATION OF CONE ALARM WILL ACTIVATE ALL ALARMS. AREAS (BEDROOMS, A APPROACHING (B BEDROOM. VAULTED C E I L I N G WITH RISE OF 24" & ON EACH FLOOR) EXHAUST FANS 100;CFM kitchen 50.±CFM bathrooms & laitund`Cy JI To �1CTto l� STAIRWAYS: Minimum width 36 in. with min. tread run of 10 in., max. rise of 7 3/4 in. & nosing of 3/4 -1 1/4 in. Min. 6 ft. 8 in. headroom. Enclosed usable space under stairways requires 1 hour fire protection of /2 in. GWB UPC 508.2 — Water heaters require anchoring or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. Washington State Ventilation and Indoor Air Quality Code requires a source specific and whole house ventilation system Minimum depth for frost protection in the City of Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. Radon Mitigation System required with 6 mil Vapor Barrier WINDOW WELL: Min. 9 sq. ft. horizontal area. Min. 3 ft. horizontal projection and width. Max. 44 in. vertical depth without a ladder Concrete lintels shall conform to Tables R611.7 (2) or (3) or Engineering is required. Reinforcement for openings in plain concrete is also required. CONCRETE TO COMPLY TO IRC TABLE 4041.1(1) FOUNDAI ION WALLS - 3000 # PSI SLABS, GARAGES, CARPORTS & PORCHES - 3500 # PSI ALL FOOTINGS MUST BE CONTINUOUS PROVIDE SOLID BLOCKING UNDER ALL COLUMNS BEARINGWALLS AND SHEAR-WALLS. PROVIDE DOUBLE JOINTS (MIN) UNDER ALL WALLS PARALLEL TO SPAN UNTO. PROVIDE DOUBLE STUDS (MIN) TO FOUNDATION UNDER ALL HP AND GIRDER TRUSSES U.N.O. PROVIDE SHEAR CONNECTION FROM INTERIOR SHEAR WALLS TO TRUSSES OR JOISTS ABOVE. 0 v 15' 0" 40' 0" 11'4" 3' -10" 3' 6" 11' 4" 3' -6' m Essi 5'0" 4040SL egress UP 2,6" 4040SL egress 10' 6" N 4'0" L2 -2x10 beam 4. -0" • 2'6„ B vi F= a' A) 4'0" 3' 10" — 4040SL egress 10' 6" 2'6" 0.d�11T d"J 9�11= io r 0 I n 2'4" 9' 2" 9' 0" T 2'6" S 2x10 floor joists 12" O.C. 4040SL egress 2'6" 18'-6" 15' 0" GYPSUM BOARD USED FOR INTERIOR BRACED WALL CONSTRUCTION SHALL E FASTENED NO FURTHER THAN 7" O.C. --------------- - - - -- 5' 0" LIVING AREA isme'ft 20' 0" Er) R602.10.4 Brace Wall Panel min. 48 in.— 96 in. R602.10.5 Continuous Wood Structural Panel Sheathing R602.10.6.1 Alternate Brace Wall Panel min.28in. -42in. R602.10.6.2 Alternate Brace Wall Panel min. l6in. -24in. IBC 2305 Engineered Shear Wall Bracing O 0) O 0) N 15' 0" 7' 9" 2'3 40' 0" 9' 8" 6' 0" 3' 8" 7, 6" 15' 4" I\ 7' 10" 7t 6050SL egress \ 50" sliding glass doo \ 4040SL egress / / / / / / / / / / 8050 -- n i 4'0" 4040SL egress 10' 0" / ) MATERIALS APPROVED FOR ONE HOUR FIRI CONSTRUCTION ON THE GAR SIDE: ❑ 5!8" TYPE "*" GYP BOAR ;HABITABLE SPAC ❑ 1/2" GVP OAR() (RESI■CNCF ATTIC. FLOOR, 2) OPENINGS BETWEEN GARAGE ANf; RESIDENCE EQUIPPED WITH SOLID WOOD DOOR, SOLID OR H[ STEEL DOORS NOT LESS THAN 1 3/8 ", OR 20 MINE DOORS. GARAGE 19' -0" x 21' -6" L . (oz . (o. 3 1\\c wrilW2Ve()-:,i(at-4x2-pr-r4lAkt Egress windows openable (VS5 5.7 sq. ft.;- 44" x111 40 -0" 16'x7'OHD 0 En f WE;EN ALLI HAVE: kElISTIVE ABJVFi OR CEILING) A IL BE rEYC OMB CORE TE FI E RATER N 10'-0" 20 0" 10' -0" LIVING AREA 1479 sq ft N1101.3.1 — Attic insulation certification required as to R— value or coverage. Markers, attached to trusses or rafters, required for every 300 sf of attic space with 1 inch high numbers for installed thickness of insulation. 1 sq.. iftil 300 sq. ft. attic ventilati 15# fell Ertagineened Trusses 24.E 0.C. ,iii# felt for ice ca db a baffles 50 dam protection wit -r 24. t oiDo6. esyr€ttaL uJAc.._ R602.134 ,,S ,fu ?!1e" osia Sheathing 8 " HP lap sidling Hie wrap under sidirm s>pe away ' from 30 Year comp roofing R -38 Blown iim ic►>uli. 7I/116" OSB Sheathing 1/8" G A P BETWEEN SHEATHING 1J2 drywail1 vapor ba r " drywall 2x4 16" 0.C. Int. Walls 314" 06B Sheathi 2x10 le" O.C. 8,.x ` 6 ind. narirreatted gate parssikaeutallon system Anchor Bolts- Min. 'A" x 9" with 7" concrete embedment at 6' o.c. and 12" from ends of sill plates. _D_a_n_ott0_0fin 1 required on foundation walls from top of footing to finished grade of crawl space or basement Z 6"x 141'" baling DIped WSW X21 .. _ aaou Cam. 4. o2xio Led14� P.r L 4o fn o v54 10 c2 b L ,2x to K: -; ,ne, v?X l0 30 s -F5 e 16," o . Wove DECKS: Ledger board requires ' /2" lag bolt @ 16" o.c. with flashing behind. Guardrail 36 in. high required if floor more than 30 in. above grade. Picket spacing no more than 4 in. apart. Posts require approved base and beam connectors. Min. 24 in. frost protection to finish grade with min. 12 in. footing base. d `2 CITY COPY 0