2011, 10-28 Permit App: 11003436 Remove Separation WallSpokane Valley�� Community Cevelopment Department Permit Center 11703 East Sprague Avenue, Suite B -3 Spokane Valley, WA 99206 Tel: (509) 688 -0036 Fax: (509) 688 -0037 oermitcenter @spokanevallev.orq (Staff Use Only) PERMIT NUMBER: PERMIT FEE: 1 I- 309b RESIDENTIAL CONSTRUCTION PERMIT APPLICATION ❑ NEW CONSTRUCTION 0 ADDITION /REMODEL El ACCESSORY BUILDING 0 OTHER 0 DECK SITE ADDRESS: / 7 7/' 1 4/ If/ ASSESSORS PARCEL NO.: cS-/t 34332 LEGAL DESCRIPTION: BUILDING OWNER NAME: NAME: I .Q V it �j C , (e4 l'' ADDRESS: / 7 //‘ //7 / J/c CITY: y 5/0 (tar, 'y (/ Gj / 1 e STATE: a.. A PHONE: J g 3 q- J (�/ 0 g FAX: CELL: C4 CONTACT NAME: PHONE: 01'22%-x: CELL: CONTRACTOR NAME: MAILING ADDRESS: ()Wyly CITY: STATE: ZIP PHONE: FAX: CELL: CONTRACTOR LICENSE No.: EXPIRES: CITY BUSINESS LICENSE NO.: DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE: iZp 0,0v,Q 2X2. fi4vfi.7` /Utz 13a14w,e1 1, 2 t.e /r oc S�a% f /nvpl /'?/, * ** *YOU MUST COMPLETE THE FOLLOWING * * ** MARK N/A IF NOT APPLICABLE Height to Peak: Dimensions: No. of Stories: Total Habitable Space: Main Floor SQ FT: Upper Floor SQ FT: Unfinished Basement SQ FT: Finished Basement SQ FT: Garage SQ FT: Deck /Covered Patio SQ FT: Impervious Surface Area: 30% Slopes on Property: No. of Bedrooms: Construction Type: Heat Source: Sewer or Septic: TOTAL COST OF PROJECT: $ DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling is /will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subseq -ntly approved before this application can be processed. Signature Date: (2 1 / 2G %/ Updated 1 -11 -11 Page 1 of 1 http: / /www.spoka nevalley.org /fi lestorage/ 124/938/210/948 / 1496 /Building_ Permit _- _Residential_11- 11- 11.doc RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. ❑ SITE PLAN ❑ Property lines and dimensions ❑ Direction arrow pointing North and orientation to streets ❑ Proposed /existing buildings (footprint and dimensions) ❑ Utilities, septic tank /drain field locations and distances ❑ Setbacks to property lines ❑ Distance between buildings ❑ Right of way /easement location & sizes ❑ Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) ❑ Elevations (Front/Rear /Sides) with roof peak and wall height including basement: El Foundation Plan (crawlspace, basement or slab on grade): ❑ Footing sizes and locations ❑ Perimeter concrete foundation wall sizes ❑ Crawlspace ventilation ❑ Supporting wood cripple walls or beams ❑ Thickened concrete pads supporting beams or girder trusses ❑ Floor Plan of each level (finished or unfinished) with dimensions: ❑ Floor Joist direction, size and spacing ❑ Window and door location and sizes ❑ Header, beam or concrete lintel sizes ❑ Window well locations if applicable ❑ Brace wall panel locations ❑ Room usage labels ❑ Water heater and furnace locations ❑ Smoke detector locations ❑ Exhaust fan locations ❑ Attic and crawl space access locations ❑ Deck or concrete patio sizes and locations ❑ Fire Wall construction ❑ Roof Plan: ❑ Engineered truss direction and spacing ❑ Rafter and over frame direction, size and spacing ❑ Ridge, eave and valley lines ❑ Beam and girder size and location ❑ Wall Section Detail including: Roof ❑ Slope/ roofing material/ underlayment/ ice dam protection ❑ Truss or rafter size, spacing & connection ❑ Sheathing size and type Ceiling ❑ Joist size and spacing ❑ Size of ceiling gypsum wall board Wall ❑ Height/ top plate/ stud size and spacing/ sole plate ❑ Exterior sheathing size and type Floor ❑ Joist size and spacing Foundation Wall ❑ Concrete or Masonry unit width ❑ Earth to wood separation distance Footing ❑ Size Radon ❑ Passive system with 6mi1 vapor barrier ❑ Attic insulation/ air space baffle/ ventilation Miscellaneous Construction Details ❑ Deck: ❑ Floor plan/ side view/ dimensions ❑ Floor Joist/ decking direction, size and spacing ❑ Stairway tread rise & run and nosing ❑ Siding/ exterior house wrap/ anchor bolts ❑ Insulation, vapor barrier, gypsum wall board ❑ Sheathing or concrete floor size/ insulation ❑ Footing bottom to finished ground level depth ❑ Horizontal & vertical reinforcement if any ❑ Reinforcement if any ❑ Active system with 6 mil vapor barrier ❑ Footings/ post/ and beam size and locations ❑ Handrail / Guard height & spacing Martin Palaniuk From: Martin Palaniuk Sent: Friday, October 21, 2011 3:37 PM To: 'Babler, Toni R.' Cc: 'jerryclark5l @gmail.com' Subject: 17116 E Alki Toni, The house located at 17116 E Alki Avenue, parcel # 55183.0332, belonging to Jerry L Clark is considered a single - family residence by the City of Spokane Valley. It was originally permitted as a duplex in 1977. The property owner has taken the necessary steps to convert the structure to a single family unit. Any attempt by future property owners to use the structure as a duplex will require the necessary connection permits for utilities and fire separation. Please contact me at 720 -5031 if you have any questions regarding this matter. Marty .Martin Palaniuk Planning Technician City of Spokane Valley 11707 E. Sprague Ave. Suite 106 Spokane Valley, WA 99206 (509) 688-0243 mpalaniuk(a�spokanevalley.org 1 Spokane Valley Residential o ccupancv Approval Project #: 11003436 City of Spokane Valley 11707 E Sprague Suite 106 Spokane Valley, WA 99206 Phone: 509.688.0036 Fax: 509.688.0037 Print Date Monday, November 07, 2011 Our records confirm that inspections were made as listed below. An approved final inspection indicates that occupancy was approved at the following location for the use indicated: Address: 17116 E ALKI AVE Owners Name: CLARK, J & M Parcel # 55183.0332 REMOVE SEPERATION WALL OF 2- DWELLING UNIT TO MAKE SINGLE DWELLING Inspection Summary By Inspection Date Description 11/1/2011 FINAL ervto, \,e. U c o Status Bebout, Bob D APPROVED 4--e) (-4-o o wvL 2 r - iV 1 ` "c i