Loading...
1992, 08-24 Permit App: 92006801 GarageSPOKANE COUNTY C)EPABTMENT OF BUILDINGS W. 1303 BROADWAY AVENUE SPOKANE, WASHINGTON 99260 (509) 456-3675 I certify that I have examined this permit /application, state that the information contained in it and submitted by me or my agent to compile said permit /application is true and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS /NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. I understand that the issuance of this permit /application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local laws regulating construction. SIGNATURE OF APPLICATION OWNER OR AGENT DATE PROJECT NUMBER= 92.006 {01 APPLICATION DATE-:: 08/24/92 2 ('A., 3=;1c *•*3t•3t THIS TS NOT A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 8105 E AUGUSTA AVE.: PARCEL „: W 45073.1433 ADDRESS= SPOKANE ,:faNr:: WA 99212 PERMIT USE= GARAGE F'I...AT.•'.= 002334 PLAT NAME= SANTA ROSA PARK. 4UB LK . 5, 6, 1 1 BLOCK= 1 LOT= 8 ZONE= UF 3 71c 4: iF:. AREA= F / F w F WIDTH= 80 DEPTH= 1200 R/;= 4 OF BLDGS : i : DWELLINGS= 1 WATER DIET = OWNER: :: BUi SHNE L.L, GARY F'HONE : ::: 5()9 535 3240 STREET= 8105 E: AUGUSTA AVE ADDRESS= SPOKANE: WA 992i 2 CONTACT NAME =: F'AUL_ WARD BUILDING SETBACKS: FRONT= 35 PHONE: NUMBER= 509 535 3240 LEFT= 15 RIGHT= 15 REAR= 4': * 3E ae a: 3c tii 3{ ii 3k 3: 3t 3t 3i k 3t 3e X k 3@ 3f ri is ri }{ * 3: fi REVIEW J: N F° o R 1 A T I Q N ,r tit 3t 1M #3:x3{ 3t x 1i 3i 3k tit 3,:* 3,: ; 3e 3i p:.k 3i• 3: * DEPARTMENT i•`•1F,Ti°iE T RF IEW COMMENTS BUILDING Pi...AN REVIEW REQUIRED BUILDING SETBACK REVIEW REQUIRED HE::AL..TF•LDI T INCREASE IN LOT COVE:.RAG 3Ex1:•x3:•• x 3{ •3rx1:•xxti:• *xx3* ** * **xxx*x*3k* T: UII CONTRACTOR= MFG • HANDYMAN YSTREET= � 1502 F:. 14TH AVE ADDRESS= SS: SPOKANE WA 99202 NEW= X REMODEL= DWEIy.^..L.. UNITS= i OCC;UP.. i...Dt= BLDG W :\ T't ._. 20 1i n20 Sw F- m: Ri:.Q PARKING= itHAItiiT).E C;ftil' .: DESCRIPTION GROUP TYPE GARAGE. i ••• i VN ITEM DESCRIPTION RESIDENTIAL V A i... U A T I O N STATE: SURCHARGE:: RE:EIDE".NTIAL.. SURCHARGE APPROVAL... tl As SCTETb4,U CS Z PHONE= 509 535 3240 ADDITION= CHANGE OE:. USE= BLDG H(:.T-:: i2 STORIES= IE: : 400 SPRINKLER= N CRITICAL M A T : ::: N SC FT 400 QUANTITY Y VALUATION 3 200 .. 00 FEE AMOUNT 4.50 11.34 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING BUILDING PERMIT 78.84 .00 78.,84 78..84 .00 78..8.4 PROCESSED C ESSE"D T:tY : DOM1:TRCiV1:CH, ROBIN PRINTED BY: DOMITR0v]:C:F•1, ROBIN 3:•3:• 313:• 1:•: i• 3:• xx*• 3fA• *3:•* x3 :•*•* *3:•3:•**3:•3:•3ixx3:•3E:. THANK `rOu xxx3:• xx) t3:.*. 3:• 3:• x3! xN .x*1h1:•x3:•3:•1:•x341!•*x** 3:•.: NOTICE It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit complies with applicable codes and requirements and that required inspections are requested. Failure to request required inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the owners/permittee's expense. At a minimum, the following inspections ARE REQUIRED by County Code: 1. FOOTING — when forms and reinforcement are in place and prior to placement of concrete. NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zoning regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from the property line or the center line of the roadway right -of -way, whichever provides the greater setback from the center line of the roadway right -of -way. Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County can own as much as 20 feet of right -of -way between your property and the actual improved street /curb. The responsibility to comply with applicable setback provisions lies solely with the permittee — neither Spokane County nor its authorized representatives assume any responsibility for the verification or location of your property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require its relocation at the owner's /permittee's expense. 2. FOUNDATION — when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a manufactured home is required to be inspected prior to the installation of skirting.) 3. FRAMING — after all framing, bracing and blocking is in place, and prior to concealing. 4. INSULATION — prior to the installation of drywall. 5. PLUMBING — after rough -in, before covering, and final. 6. MECHANICAL — rough -in of piping, before covering, metal chimneys before concealment, and final. 7. FINAL — when complete and prior to occupancy and /or use. Please provide 24 hours notice. NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access, on -site drainage ( "208 swaies "), road improvements, parking, and landscaping are common requirements of a permit /site plan which must be completed prior to final approval of a building or issurance of a Certificate of Occupancy. In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall, concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with commercial projects. CALL 456 -3675 FOR INSPECTIONS. TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE. YOUR INSPECTOR IS UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES: • road cuts for utilities or drives, State or County Engineer's Office 456 -3600 • on -site waste disposal system, Environmental Health District 456 -6040 • construction in a flood plain, County Engineer's Office 456 -3600 • electrical wiring, State Department of Labor and Industries 456 -2792 • sewer connection, County or City Utilities Department 456 -3604 EXPIRATION Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration. At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one -half the original fee, subject to certain limitations — please call us if you have any questions. MISTAKES? If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous information in the permit, please bring it to our attention immediately by filing a written request for correction within 10 working days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this permit. MR. HANDYMAN 1502 East 14th SPOKANE, WASHINGTON 99202 (509) 535 -3240 Lic. #MRHAN *094M5 JOB SHEET NO OF CALCULATED BY DATE CHECKED BY DATE SCALE • 6e ry 8(45-/,(4_4_ 0 4_ Le s P- 0-o . /. Lv n ocrJ r0c-„ Corvie/ of {.ousN • } row C7— eX4Q tov- co,r•,p lefe 3` Fj ruck_ lo(.F'e", ec c or n e OL LlG vtse, &Jai' c_v-)v)) LL k- -I = 'i / _s10 s/q-v.a- s .— SITE ADDRESS: E 8105 AUGUSTA AVE PROJECT NUMBER: 92006801 PERMIT TYPES: BU PERMIT USE: ATTACHED GARAGE DESCRIPTION FOOTINGS REINFORCEMENT FRAMING DRYWALL /FIREWALL FINAL INSPECTOR SILVA, DAVID SILVAN DAVID SILVA, DAVID SILVA, DAVID SILVA, DAVID O DATE 08/31/92 09/02/92 08/02/94 08/02/94 08/02/94 RESULT APPROVED APPROVED APPROVED APPROVED APPROVED