2006, 10-19 Permit App: 06004189 MHProject Number: 06004189 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Date: 10/19/2006 Page 1 of 2 Permit Use: PLACE 2006 27X56 SKYLINE MFH Setbacks: Front Left: Right: Rear: Site Information: Contact: CLAYTON HOMES Address: 15906 E SPRAGUE AVENUE C - S - Z: SPOKANE VALLEY, WA 99037 Phone: (509) 891 -9996 Group Name: Project Name: Plat Key: Name: MISSION MEADOWS MHP MFG HOME PK 123 UNITS District: East Parcel Number: 55083.9601 Block: SiteAddress: 19414 E AUGUSTA LN Location:: CSV Zoning: UR -7 Water District: Urban Residential -7 Lot: Owner: Name: CLAYTON HOMES Address: 15906 E SPRAGUE AVENUE SPOKANE VALLEY, WA 99037 Hold: ❑ Area: 0 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Flood Plain Released By. Building Plan Review RleadBy Landuse /Zoning/HE Conditions Released By Sewer Review Released By: Permits: Operator: AMB Printed By: AMB Print Date: 10/19/2006 Permit Center SliUkane 11707 E Sprague Ave, Suite 106 a Spokane Valley, WA 99206 i (509)688 -0036 FAX: 09)688 -0037 Community Development www.spokanevalley.or \ 00 1 2 OTHER Manufactured Home Permit Application PERMIT NUMBER: 41 g PERMIT FEE: SITE ADDRESS: / 4/9 f+tr/ivjk Lane. ASSESSORS PARCEL NO: 5-5093, LEGAL DESCRIPTION: L07 7(2 5 /do Mad d•zv S AP Building Owner: Name: (/ a.9 ,fo, ,j j. es Name: u�A- 116LO✓I Address: l Sgot • S/Ak_e_ five City:5,, 61, '/U /l State:IA/4 Zip:9f037 Phone: - $ q., ._.. III Fax: City: Contact Person Name: K l ' QI/ 17/1/71 Phone: O — 9s 3 392- 3 Contractor: Name: u�A- 116LO✓I Address: City: State: Zip: Phone: Fax: Contractor Lic No: Exp Date: City Business Lic. No: Describe the scope of work in detail: 6e4 maka 4 I MANUFACTURED HOME Width: 27 !co Length: 56 '...1.0// Year: zoo C, Pit Set: ye s ewer:, j Manufacture: 5 k-y 1 h Previous Address: Proposed Use: Res ?1- ( 1I-ow e The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is /will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature Method of Payment: ❑ Cash ❑ Check Bankcard #: Authorized Signature: REVISED 8123!2005 ❑ Mastercard Expires: Date O l8; 2006 ❑ VISA VIN #: PAGE 04/04 SKYLINE HOMES SALES 5034729511 08/14/2006 If 8' 5' tity elet\o Forrn-rA ri OT �wrg 6i2, OM Mg MAKI Nil row IncriNnia0111 ,riair OW14 11' 8" f-Y17 2V-fr AI NOR IC,: TT REC [11191 kron (01 OPT REC EffiR 11' Cf'T UTILiTY L J L\--)T E.O 5•0 DIVIsTONS Thi 341 112 344 115 345 125 355 13i 528 143 531 16'3 535 171 538 181 538 552 tr, 553 7 0 57] X 591 E, 812 BOX LENGTH EICRIPT1019 4K-8-3cr-n-cal DPAIII; eV Sk /Zan DIME DI/J/20:6 IinCir ?off SHEET : GI DRAWING NUMBER •I 1221)-CT Pier Spacing Under Main I-Beams (Ft.) I 6 v 9 10 Wt. Per Foot See Note 5 NOTES: 20' WIDE HOMES - - -• ..,. a I ric '4urritMbNTS (Cont TABLE 2 PIER LOADING UNDER MAIN I -BEAMS DOUBLE -WIDE HOMES 24' WIDE HOMES 26' & 28' WIDE HOMES Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone 1810 2270 2720 3170 3630 4080 4540 Pier Load (Lbs) 20 PSF Roof Zone 2060 2580 3100 3610 4130 4640 5160 Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone 2170 2710 3260 3800 4340 4880 2100 2630 3150 3680 4200 4730 32" Pier Lc (Lbs 20 PS Roof Zone 5420 5250 516 116111 2390 2980 3580 4180 4770 5370 5970 597 2560 3190 3830 4470 5110 5750 6380 638 2360 2950 3540 4130 4720 5310 5900 590 2630 3350 4020 4690 5360 6030 6700 670 2940 3670 4410 5140 5880 6610 7340 80 3350 4020 4690 5360 �+ ,+ 6700 670 1. See Table 4 for minimum footing sizes based on pier Toads and allowable soil bearing ca loads are minimum required for the applicable conditions. The footing shall not be smaller than square inches. 9 pacities. The foc the pier it 2. The maximum spacing of supports is not to exceed 10 feet. 3. Where it is impractical to maintain spacing, such as in the axle area, the average of the di may be used to determine support requirements. For example: if the distar.Les to the adjacent su the average spacing would be 7' -0 ". stance to each pports $.0‘ „ t 6_0 l t I < $,_6„ 1 Pier A Pier B Pier C The average spacing for pier B would be (6 + 8) / 2 = 7 ft., therefore, pier B would be designed for 4. Concentrated Toads at marriage line (see Table 3). g 7 ft pier 5. The last line in the above Table is the weight per foot each main I -beam is carrying. Multiply l this number by is carrying to determine the required capacity of that pier. i 14 prNDATION AND SUPPORT REQUIREMENTS (Continued) TABLE 3 PIER LOADING UNDER CENTERLINE BEAMS Span 3etween '.olumns (Ft.) See note 1 20' WIDE HOMES Ar. •Ea.,._ 24' WIDE HOMES • •v W•tr_v 26' & 28' WIDE HOMES 32' WIDE E Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone _ Pier Load (Lbs) 20 PSF Roof Zone Pier Lo (Lbs; 30 PS Root Zone 6 900 1200 1500 1080 1440 1800 1260 1680 2100 1350 180Q 3000 10 1500 2000 2500 1800 2400 3000 2100 2800 3500 2250 12 1800 2400 3000 2160 2880 3600 2520 3360 4200 270Q 3600 14 2100 2800 3500 2520 3360 4320 2940 3920 4900 3150 4200 16 2400 3200 4000 2880 3840 4800 3360 4480 5600 3600 4800 18 2700 3600 4500 3240 4320 5400 3780 5040 6300 4050 4500 540Q 6000 20 3000 4000 5000 3600 4800 6000 4200 5600 7000 24 3600 4800 6000 4320 5760 7200 5040 6720 8400 5400 7200 TOTES: Where a column is located between two openings, sum the loads for each opening to obtain the required pier load. See table 4 for minimum footing sizes based on pier loads and allowable soil bearing capacities. The concentrated load consist of roof load only. Pier locations at the marriage wall are marked with paint or metal indicator straps. Piers used side by side to obtain the required load are permissible. PIER LOADING AND INSTALLATION UNDER SIDEWALL DOORS AND WINE :Unit sidewall Typical door or window opening - Width varies t - see table below. Floor joists 4 block, 4" longer 3n joist spacing. Stalled such that it ans joists on either ie of door jamb. Pier installed when joist s not under door jamb. Pier installed when joist is under door jamb. See note 6: Unit sidewall SECTION A -A' Floor joists Typical Pier Nominal Unit Width (Ft.) 48" OPENING 78.5" MAX. OPENING 108" MAX. OPENING 121" MAX. 0 Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone Pier Load (Lbs) 20 PSF Roof Zone Pier Load (Lbs) 30 PSF Roof Zone Pier Load (Lbs) 40 PSF Roof Zone Pier Load (Lbs) 20 PSF Roof Zone Pier Loa (Lbs) 30 PSF Roof Zone 12 500 640 790 810 1050 1280 1110 1440 1760 1250 1610 14 550 710 870 890 1160 1430 1230 1600 1960 1370 1780 16 600 780 960 980 1270 1570 1340 1750 2260 1500 1960 18 650 840 1040 1050 1380 1700 1450 1890 2340 1620 2120 20 440 570 690 720 920 1130 990 1270 1550 1100 1420 24 500 640 790 810 1050 1280 1110 1440 1760 1250 1610 26 520 680 830. 860 1110 1360 1180 1520 1870 1320 1710 28 540 700 860 880 1140 1400 1210 1570 1930 1350 1750 32 590 760 940 950 1240 1530 1310 1710 2110 1470 1910 IOTES: Piers are required at all entry doors and window openings greater than four feet. Piers are also required at bay windows where the sidewall opening is greater than four feet. Piers are not required at door and window openings located along endwalls. Piers are not required at some door and window locations if the floor has been reinforced at the factory. Contact the division that built your determine if this is applicable to your home. See table 4 for minimum footing sizes based on pier loads and allowable soil bearing capacities. Maximum pier setback is 6 ". If pier load (from table 3A) is 1240 lbs. or less, and nominal unit width is 12', 14', 20', 24', 26', or 28', then sett max. If pier load (from table 3A) is 1930 lbs. or less, and nominal unit width is 18', 18', or 32', then setback may be 10" max. For piers between multiple openings, sum the loads for each opening to obtain the required load. 11A i I PEN? T 40.4•, • f Na * : r i i 19600312 , r • q STATE 3 STATE #SS oiANP,� � t� '.i. 4ONas .. .- ...Norm' 11.1 I uc-uvvvIV VC IAIL, W .a z X ¢ a O J tu J < W aii 00 z S to cE O O J 1 W F w 177 X w i TABLE 6 SEE NOTE #1 STRAP ANGLE STRAP ANGLE ANCHOR TO BE RATED FOR 36844' OF WORKING STRESS, TOTAL FOR BOTH STRAPS. (INSTALLED PER ANCHOR MANUFACTURER'S INSTRUCTIONS SEE NOTE 3) SINGLE -WIDE INSTALL Si 6'-8 5' 4'-0" @ FOR f. SING SEE TABLE F STRAP AN( P I_li --I ( STRAP ANGLE 19 I 1 I—T—I I I— r - -I PI ~j--i I 1-1-I 1--I- T 1 STRAP ANGLE ANCHOR TO BE RATED FOR 36844' OF WORKING STRESS, TOTAL FOR BOTH STRAPS. (INSTALLED PER ANCHOR MANUFACTURER'S INSTRUCTIONS SEE NOTE 3) DOUBLE -WIDE * USE 24' WIDE RESULTS FOR 12' HALF OF 22' WIDE DOUBLE WIDES SEE N WIDTH 12' 14' W ND ZONE II MIN. & MAX. ELEVATION 12' SHED ROOF 14" TO 25" 12" TO 27" MIN. & MAX. DIAGONAL STRAP ANGLE 25° TO 40° 14' SHED ROOF 16' 18' 20' OR22'• 24' 28' 25.2"TO 34.6" 23.4" TO 38.4" 16" TO 36" 20" TO 44" 12"TO 15" 12" TO 22" 32' 16' SHED ROOF 12" TO 23.5" 12" TO 33" 21 "TO 27.5" 20.5° TO 40° 41°T050" 36° TO 50° 20.5° TO 40° 20.5° TO 40° 34° TO 40° 24.5° TO 40° 23° TO 40° MIN. & MAX. ELEVATION 14" TO 26" 12"TO 28" WIND ZOI DIA 25.2"TO 34.6" 23.4" TO 38.4" 15.5" TO 38" 16.6° TO 39 -3° 25.9° TO 32.4° 19" TO 47" 12" TO 16" 12" TO 23.5" 12" TO 25.5" 12"TO 36" 21 "TO 27.5" NOTES: 1) FOR STRAP MATERIAL SPECIFICATION, CONNECTION TO FRAME I -BEAM & OTHER SETUP INFORMATION, REFER TO SK, MANUAL 2) FOR ANCHORING SYSTEMS, THE INSTRUCTIONS SHALL INDICATE: A) THE MINIMUM ANCHOR CAPACITY REQUIRED; B) CERTIFIED BY PROFESSIONAL ENGINEER, ARCHITECT OR A NATIONALLY RECOGNIZED TESTING LABORATORY AS TO 1 BASED ON THE MAXIMUM ANGLE OF DIAGONAL TIE AND /OR VERTICAL TIE LOADING AND ANGLE OF ANCHOR INSTALLA IN WHICH THE ANCHOR IS TO BE INSTALLED; C) GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE / INCHES ABOVE THE WATER TABLE; D) GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILI2 BE INSTALLED TO PROVIDE ADDED RESISTANCE TO OVERTURNING OR SLIDING FORCES; E) ANCHORING EQUIPMENT BY A PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WITH TESTIN( STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS. 3) ANCHORS RATED @ 3150# OF WORKING STRESS TOTAL FOR BOTH STRAPS, MAY BE USED IF STRAP & ANCHOR SPACIN @ WIND ZONE II AND 4' -6" @ WIND ZONE III. STRAPS AND ANCHORS MAY BE INSTALLED 4' -0" O.C. ON SHED ROOF SINGI ANCHORS RATED @ 3150 #. 4) THE A -B CHANCE STRAP SEAL DEVICE DEPICTED BY FIG. 5 -12 MAY BE USED AS DIRECTED FOR ATTACHING THE REQUIF CENTERLINE STRAPS TO GROUND ANCHORS. 5) STANDARD TIE -DOWN DETAILS ARE NOT APPLICABLE TO 5/12 ROOF PITCH DOUBLEWIDES @ WIND ZONE II & III. 30 SKYI