Residential Building Air Leakage Test (Blower Door Test) Results
Permit#: 1\- 0` -to
House address or lot number:
City: 5 pole -0..t. l��le. Zip: 911 2-0 (40
Cond. Floor Area (ft2): 1 2_5-0 Age of house: Oct-)
Source (circle one): /Plans Estimated Measured
Results shall be reported as Specific Leakage Area (SLA) and shall be calculated as follows:
SLA = (CFM50 x 0.055)/(CFA x 144)
Where:
CFM50 = Blower door fan flow at 50 Pascal pressure difference
CFA = Conditioned Floor Area of the housing unit
Blower Door Test Result: .0°0 W.71 SLA
to -R CFM@50Pa
Ring (circle one if applicable):
Open
A
B
Blower Door Fan Location: (nc,ro., boor Weather Conditions: yM—,‘ /No (�;A)
I certify that these blower door results are accurate and determined using standard industry protocol.
Company Name: l -aa 1-1/2SA Technician:i�__,t m w tt .c LA -Th
Technician Signature2_ J 2 Date: 8/x-1711 Phone Number: 5-04k- -3Z-911 O _
2009 Washington State Energy Code reference:
502.4.5 Building Air Leakage Testing: Building envelope air leakage control shall be considered acceptable when tested to
have an air leakage less than 0.00030 Specific Leakage Area (SLA) when tested with a blower door at a press of 50 Pascals
(0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope,
including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. When
required by the building official, the test shall be conducted in the presence of department staff. The blower door test results
shall be recorded on the certificate required in Section 105.4.
EXCEPTIONS: 1. Additions less than 750 square feet.
2. Once visual inspection has confirmed the presence of a gasket (see Section 502.4), operable windows
and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test.