Loading...
HomeMy WebLinkAbout2014, 06-30 Permit: BLD-2014-0211 Duct Leakage AffidavitSu p p o r t Energy Code WASHINGTON STATE UIN[VERSITV ® EXTENSION ENERGY PROGRAM Permit #: Duct Leakage Affidavit (New Construction) House address or lot number: 1324 N Arc S . City: Spoitoone \k.11e.i Cond. Floor Area (ft2): ILI G\ Zip: cl4016 Source (circle one): ( Plans estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? 0 yes ® no Air Handler present during test? ® yes ❑ no Circle Test Method: Leakage to Outside Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .04) = S4 CFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM@25 Pa Test Result: S6 CFM@25Pa Ring (circle one if applicable): Open 1 0 3 Duct Tester Location: Lemer lave ( re }urs Pressure Tap Location: Supply _ veH4- I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name: NC}Z Technician Signature: Date: 6- 30 - l `l Phone Number: 208) 96M-SOel Technician: Kyle Eutflny Cmc}e' S- `u . o r t WASHINGTON STATE UNIVERSITY ® EXTENSION ENERGY PROGRAM Permit #: Duct Leakage Affidavit (New Construction) House address or lot number:Ig26 N Arc SV - city: Spo1(AV SIG\\rg Zip: 9 1b Cond. Floor Area (ft): I990 Source (circle one): Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? 0 yes lid no Air Handler present during test?,® yes 0 no Circle Test Method: Leakage to Outside Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM@25 Pa Rough -in, total duct leakage with air handler installed: (floor area x .04) = S9 CFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM@25 Pa Test Result: 57 CFM@25Pa Ring (circle one if applicable): Duct Tester Location: Fucvwce Open 1 2 3 Pressure Tap Location: l-inuNaci/ Q. SuPPly I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name: 0uci-2- Technician Signature: Date: 6 - 3Ci'ILI Phone Number: (20 B ) 96o1 - So$5 Technician: ICI IL ks'o"