Loading...
HomeMy WebLinkAbout2014, 07-10 Permit: BLD-2014-0207 Duct Leakage Affidavit (2)LAS pagy Code" Support.. - WASHINGTON_ STATE_;UN WRSITY ®EATENSIONENERGY PROGRAM Permit #: Duct Leakage Affidavit (New Construction) House addressor lot number: 131'1 kJ Arc SI - City: Sfk+\rrnt, e V�nlle Zip: gg016 Cond. Floor Area (f12): Ijgo Source (circle one): Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? ❑ yes ® no Circle Test Method: Leakage to Outside Air Handler present during test? RI yes ❑ no Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .04) = Sct CFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM@25 Pa Test Result: S6 CFM@25Pa Ring (circle one if applicable): Duct Tester Location: Furho,e.c Open 1 3 Pressure Tap Location: Iry ani Rn., Supply I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name: Doc{ -2., Technician Signature: Date: -7-10--1`1 Technician: Kylc Scnvlsotn Phone Number: (208) %L1- Sot%