2008, 03-28 Permit App: 08000902 Remodel, Plumbing FixturesProject Number: 08000902 Inv: I
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Date: 3/28/2008 Page 1 of 2
Permit Use: NEW SIDING, WINDOWS, EGRESS WINDOW, Contact: MCBRIDE, JOHN R & LORNA R
UPGRADE KITCHEN & BATH Address: 20632 E SALTESE LAKE RD
C - S - Z: SPOKANE VALLEY, WA 99016-9776
Setbacks: Front Left: Right: Rear: Phone: (509) 927-7915
Group Name:
Site Information; Project Name:
Plat Key: Name: Range District: East
Parcel Number: 55184.2404
SiteAddress: 18518 E BOW AVE
Location:: CSV
Block: Lot:
Owner: Name: MCBRIDE, JOHN R & LORNA R
Address: 20632 E SALTESE LAKE RD
SPOKANE VALLEY, WA 99016-97
Zoning: MF -1 MF MDR District
Water District: 134 CONSOLIDATED ID #19
Area: 16,000 Sq Ft Width: 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information:
Review
Building Plan Review
Permits:
Hold: ❑
Depth: 0 Right Of Way (ft): 0
n
Released By:
Originally Released: 3/28/2008 By: tmelbourn
Contractor: OWNER
Building Permit -- — Firm: OWNER
Phone: (000) 000-0000
This Application:
Description Grp Type Notes So Ft Valuation
1&2 FAMILY R-3 VB REMODEL 0 $2,600.00
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Total Project:
Sq Ft Valuation
0 $2,600.00
Totals: 0 $2,600.00 0 $2,600.00
Units Unit Desc Fee Amount
1 SELECT $83.25
1 SELECT $4.50
1 SELECT $33.30
Operator: jmm Printed By: JD
Permit Total Fees: $121.05
Print Date: 3/28/2008
Project Number: 08000902 Inv: I
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Plumbing Permit --
Firm: OWNER
Phone: (000) 000-0000
Date: 3/28/2008 Page 2 of 2
Contractor: OWNER
Item Description
TOILETS/BIDETS
TUBS
Notes:
Payment Summary:
Permit Type
Building Permit
Plumbing Permit
Units Unit Desc
1 NUMBER OF
1 NUMBER OF
Permit Total Fees:
Fee Amount
$6.00
$6.00
$12.00
Fee Amount Invoice Amount Amount Paid Amount Owing
$121.05 $121.05 $0.00 $121.05
$12.00 $12.00 $0.00 $12.00
$133.05 $133.05 $0.00 $133.05
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: jmm Printed By: JD
Print Date: 3/28/2008
*Wane
Community Development
Residential Construction
Permit Application
Permit Center
11703 E Sprague Ave, Suite B-3
Spokane Valley, WA 9:serr.:-.
(509)688-0036 FA14
PO88-0037' VPIL—
www.spokanevalley.Wrg
fAt1/41( 4 2110
PERMIT NUMBER:
PERMIT FEE:
New eo uction
Addition/Remodel
Other:
1 1
Accessory Bldg
Deck
SITE ADDRESS: 1 R'S / E
ASSESSORS PARCEL NO: LEGAL DESCRIPTION:
Building Owner: A -)11c:Lti
DIMENSIONS:
Name: Ln V 00 li)(1C t>r 1 U -
Name:
Address: 1
2' FLOOR SQ. FTG:
City: tcriSspokAdk Di)//1 State:
Zip: K0/4,
Phone: 9/5 if/
City:
Contact Person
Name: ,..(:)f )n f\E
Phone: S09 V? -? 9 t
Describe the scope of work in detail:
SA Li (A)-1,;v414A )-3 t4ffloi
Proposed Use:
Contractor:
DIMENSIONS:
# OF STORIES:
Name:
MAIN FLOOR TO SQ.
FTG: 13/0
2' FLOOR SQ. FTG:
Address:
IMPERVIOUS SURFACE
AREA:
FINISHED BASEMEN1
SQ. FTG:
City:
State:
Zip:
Phone:
Fax:
HEAT SOURCE:
Contractor Lic No:
Exp Date:
City Business Lic. No:
Cost of Project: $
ta
cfl
(900°
**************The followin2 MUST be com lete:
write N/A if not a licable)**********************
HEIGHT TO PEAK:
DIMENSIONS:
# OF STORIES:
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
FTG: 13/0
2' FLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
IMPERVIOUS SURFACE
AREA:
FINISHED BASEMEN1
SQ. FTG:
GARAGE SQ. FTG: \f
DECK/COV. PATIO SQ. FTG:
30% SLOPES ON
PROPERTY:
# OF BEDROOMS: N
0-C\
CONSTRUCTION TYPE
PIN
HEAT SOURCE:
SEWER OR SEPTIC?
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application canli.7p3cessed.
(Ci e:62
SIGNATI) ZA6
Methopf of Niment:
0 Cash
Bankc rd #:
Authorized Signature:
REVISED 2/15/07
0 Check
0 Mastercard
Expires:
DATE:
M VISA
VIN#:
SCITYO��e 11703 E Sprague Ave Suite B-3♦ Spokane Valley WA 99206
p♦509.688.0036 ♦ Fax: 509.688.0037 •
Valle
y
El
El
El
❑X
0
Completed Building and Mechanical Application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature and date.
Three (3) sets of plans including Site Plan, elevations, floor plans, foundation plans
with details, roof plan, framing plans and details.
Show the height of any proposed buildings or accessory structures.
Floor plan for each floor: Dimension to scale(minimum 1/8") and label each room
(including sq footage of house and garage on plans) show each level of existing
house and square footage of any additions.
Egress windows: Provide at least one window or exterior door approved for
emergency escape or rescue from basement and in every room for sleeping.
Floor framing details: Joist type, size, spacing and installation details.
Roof framing plan and details
3 9 .
Furnace and hot water heater location
All header locations: type, size and connections
Foundation plan
Insulation information
Decks and Stairway details
All braced wall panel types: show locations and details of installation, including
engineered design
Smoke detector locations
22" x 30" attic access location
18" x 24" crawl space access
One-hour separation detail: between house and garage
sliekarThe
... Mi11ey
Permit Center
11703 E Sprague Ave, Suite B-3
' Spokane Valley, WA 99206
(509)688-0036 FAX: (509)688-0037
Community Development www.spokano.alley.org
Plumbing Permit Application
❑ Commercial
PERMIT NUMBER:
PERMIT FEE:
❑ Residential
SITE ADDRESS: p S I o E
c_ /Z �^ + n 6
Building Owner ',ow
n
Name: ),Ok l) 11 III 6 r / t\
>
Phone: V - / C1 /qSn
�j
C /� SIP 7 --f7
pP
Address: ) S / � f , 1C4/u J
City: (e ke v.r j) 4
U
State: J. )✓t Zip: �/ l
Contractor s A m
Name:
Phone:
Fax:
Address:
City:
State:
Zip:
License No:
City Business Lic:
Contact
Name:
Phone:
1
2
3
4
5
DESCRIPTION OF WORK
TOILETS
# OF UNITS
X
COST
TOTAL. AMOUNT
WATER CLOSET, BIDETS
X
$6.00
cO
URINALS
TUBS
X
$6.00
X
$6.00
SHOWERS (PER TRAP)
SINKS
BATH, STALL, ON-SITE BUILT
X
$6.00
LAVS/BASINS, BAR, FLOOR, KITCHEN,
LAUNDRY, UTILITY, JANITOR, PHOTO,
X-RAY, FOOD, PREP/CULINARY MEAT
X
$6.00
6
7
8
9
10
11
12
13
14
15
16
DISHWASHER
X
$6.00
CLOTHES WASHER
X
$6.00
GARBAGE DISPOSAL
WATER SOFTENER
X
$6.00
X
$6.00
ELECTRIC WATER HEATER
FLOOR DRAINS
NOTE: IF GAS, SEE MECHANICAL
X
$6.00
AREA, CASE, COIL, TRENCH,
CONDENSATE
X
$6.00
ROOF DRAINS/OVERFLOW DRAINS
FOUNTAINS, DRINKING
X
$6.00
X
$6.00
WATER PIPING/DRAIN-IN WASTE,
VENT, PLUMBING, REVERSAL
SEWAGE EJECTOR
NSTALLATION, ALTERATION, REPAIR,
REVERSALS
X
$6.00
GRINDER, SUMP PUMP
X
$6.00
WATER USING DEVICE
ICE AN/OR COFFEE MAKER, HOSE BIB,
STEAMER
PROOFER, CARBONATOR, SWAMP
COOLER
X
$6.00
17
18
19
20
21
22
CROSS CONNECTION DEVICE
INTERCEPTORS
VACUUM BREAKER, CHECK VALVE,
AND R.P.B.P.D. FOR: VATS, TANKS,
BOILERS
X
$6.00
GREASE TRAP, SAND TRAP,
CHEMICAL HOLDING TANK
X
$6.00
MEDICAL GAS (per outlet)
NITROUS, OXYGEN
X
$6.00
MISCELLANEOUS PLUMBING FIXTURE
PRIVATE SEWAGE DISPOSAL/SYS
X
$6.00
X
$20.00
INDUSTRIAL WASTE INTERCEPTOR
METHOD OF PAYMENT:
X
$15.00
❑CASH ❑ CHECK ❑ VISA ❑ MC
Card#
EXPIRES:
VIN:
SUBTOTAL
PROCESSING FEE
$35.00
TOTAL PERMIT FEE DUE:
AUTHORIZED SIGNATURE:
Effective October 28, 2007
P:\Community Development\Forms\Building forms\Plumbing Permit Application.doc
Okane
Valley
EMERGENCY ESCAPE AND RESCUE
EGRESS WINDOW
*Minimum 20" wide clear opening
*Minimum 24" high clear opening
*Minimum 5.7 sq ft openable area
**5.0 sq ft minimum @ grade floor
*Top of sill maximum of 44" above finished floor
20' CLEAR 1
MIN
4/I
•
OPENABLE
AREA
\ 5.7 SO FT MIN
(5.0 SQ FT MIN
GRADE
FLOOR)
MINIMUM SIZE
WINDOW FOR 20 IN.
CLEAR WIDTH
41' CLEAR
SILL HEIGHT
44MAX
34' CLEAR
\ 7
\ .7
\ 7
.... 7
OPENABLE AREA
5.7 SO FT MIN
(5.0 SQ FT MIN
GRADE FLOOR)
7'
MINIMUM SIZE WINDOW
FOR 24 IN. CLEAR HEIGHT
24' CLEAR
MIN
FLOOR
Grade floor opening is a window or other openings located such that the sill height of
the opening is not more than 44" above or below the finished ground level adjacent to
the opening.
WINDOW WELL
*Minimum 36" x 36"
*Minimum 9 sq ft clear floor area
*Top of wall a maximum of 44" above
the floor of the well
*A guardrkil is not required unless an
exit way adjoins the well
*Provide drainage
DEEP WELLS
*If the top of the window well wall is more
than 44" above the floor of the well, either
a permanently fixed ladder or stair egress
is required.
*The ladder or stair may encroach a maximum
of 6" into the required clear floor space.
WINDOW WELL
LADDER OR STAIR
REQUIRED
'///,\\\'/// 97/
'./1/% '1/'
'n/'
v\\\ \\\V// \\\"fig/,\\\
NET CLEAR DIMENSIONS WHEN
FULLY OPENED TO PROVIDE
9 SQUARE FEET OF OPENING
EMERGENCY ESCAPE
OR RESCUE OPENING
WITH FINISHED SILL
HEIGHT BELOW
ADJACENT GRADE
LADDER EGRESS
*At Ieast 12" in width
*Rungs not more than 18" on center
*Minimum 3" toe space
*Permanently fixed
*Non-combustible
*Shall extend to top of wall
LADDER OR STAIR PERMITTED
TO ENCROACH MAXIMUM OF
6 INCHES INTO REQUIRED
DIMENSIONS
'/// AN,
'/J/\\\'/// \\' '///.\\\'///
36' MIN
36' MIN
*Where bars, grills, covers, screens or similar devices are installed over emergency
escape and rescue openings, they must be openable from the inside without the need
of special knowledge or special tools, and the force to open them may not be greater
than that required of the opening itself.
t
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR, OR"WHEWONEOR MORE
SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING f
DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
SMOKE ALAIMO . S •E INTERCON-
MANNER AANNS� NA►COM�E, N..OP'SUCH . A
MANNER TIIl11 ONE
ALARM WILL ACTIVATE 'ALL ALARMS.
(BEDROOMS, AREAS ,APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24" & ON EACH FLOOR)
EMAERGENCY EGRESS
FROM SLEEPING
) NET CLEAR OPENING:
GRADE FLOOR OPENING 04AX 4
NET CLEAR OPENING HEIGHT
) NET CLEAR OPENING WIDTH
) MAX FINISHED SILL HEKiNT
) EMERGENCY ESCAPE &RESC
PERATIONAL FROM THE INSIDE
HE USE OF KEYS OR TOOLS
OUIREMENTs
5.1 SQUARE FEET
) S.SSUG FEET
24 20INCHES
44' ABOVE FLOOR
OPENING SHALL BE
THE ROOM WITHOUT
2006 IRC
Ten Things You Must Know!! 1ZV 5F 6. -err
„ 0 -
1 R105.2 'Work Exempt From Permit" — Spokane County will maintain the 200
sq/ft threshold for one-story detached accessory structures used as tool and storage
sheds, or similar uses.
2. Table R301.5 "Live Loads" — Attic storage is clarified in the footnotes of this table.
An example: If two or more adjacent trusses with the same web configuration
contain a rectangle 42 inches or greater in height by 24 inches or greater in width,
located within the plane of the truss, a 20 psf live load must be applied to the design
of the bottom chord components affected.
3 R319.L5 "Exposed Glued-laminqted Timbers" — Those portions of glu-lam
timbers that form structural support_of buildings/structures and are exposed to the
weather, and not protected by a roof, eave, or similar covering shall be pressure
treated, or naturally durable wood.
4. WAC AMENDMENT R327 "Protection Against Radon" — State adoption of
IRC Appendix F for mitigation measures applicable for buildings constructed in
"High Radon Potential Counties" (Spokane county). Appendix F, Section AF101.1
(WAC Amendment) no longer permits un -vented (conditioned) crawl spaces.
Appendix F further requires passive radon vents to be installed in vented crawl
spaces. WAC Amends R408.2, permitting 1:300 sq/ft ratios for ventilating crawl
spaces.
5. R406.1 "Foundation Damp -proofing" — Language change removes "habitable or
usable spaces", and replaces with "foundation walls that retain earth and enclose
interior spaces and floors below grade..." effectively requiring damp -proofing of
crawl space foundation walls. R406.2 similar for water -proofing.
6. R613.2 'Window Sills" — New section requires protection similar to guardrails (4"
fbiipklabN portions of windows less than 24 inches above the finished
greaterIhn /2 inches above the adjacent exterior grade or surface below.
7. R702.4.2 Tile Backer Board — Requires cement, fiber -cement, or glass mat gypsum
backers for tile installation in tub and shower areas and wall panels in shower areas.
8. R703.2 and Table R703.4 "Water -resistive Barrier" — Felt, or other approved
barriers (house wrap) are now required over all exterior wall studs or sheathing, nd
there is no longer an exception for not requiring such felt/barriers under panel
sidings with shiplap joints.
9. R703.8 "Flashing" — The provisions for self -flashing windows (use if the window's
mounting flange) has been eliminated. Approved corrosion -resistive flashings must
be applied shingle fashion at all door/window openings. R613.1 requires window
manufacturers to provide installation/flashing instructions for each window.
10. Washington State Energy Code Section 505.3 "Outdoor Lighting" —
Luminaries providing outdoor lighting and permanently to residential buildings must
.,„Itliigh efficiency (compact fluorescent) bulbs with pin style base. Exception allows
incandescent fixtures controlled by motion sensors with integral photo sensors.