2006, 03-27 Permit App: 06000942 Finish BasementProject Number: 06000942 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 3/27/2006 Page 1 of 2
Project Information:
• yipwwwww.,..-eowwwolgswwtot
Permit Use: FINISH BASEMENT: FRAME, INSULATE &
DRYWALL
Setbacks: Front Left:
Right: Rear:
Site Information:
Plat Key: 005709 Name: CHINOOK NO 3 ADD
Contact:
Address:
C - S - Z:
Phone:
Group Name:
Project Name:
FALK, WILLIAM & SHANNON
16309 E BROAD AVE
SPOKANE, WA 99216
(509) 922-4682
District: H
Parcel Number: 46364.1002
Block:
SiteAddress: 16309 E BROAD AVE
Location:: CSV
Zoning: UR -3.5
Water District:
Urban Residential 3.5
Area: 1,258.00 Acres
Lot:
Owner: Name: FALK, WILLIAM & SHANNON
Address: 16309 E BROAD AVE
SPOKANE, WA 99216
Hold: ❑
Width: 125 Depth: 80 Right Of Way (ft): 50
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:
Review
Building Plan Review
Permits:
Released By:
Originally Released:
3/27/2006 By: TMELBOU
. f411 1116,016it77 S4772i :Y..!\liVPNLYer 1.1700,0110RiOr Rt^.•a,cifV,411WMP,P`YL':aa: 7/1%73T
Contractor: OWNER
Description Grp Type Notes
GARAGE U-1 VB k
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Operator: AMB
Building Permit
Firm: OWNER
Phone: (000) 000-0000
This Application:
Sq Ft Valuation
0 $4,500.00
Total Project:
Sq Ft Valuation
0 $4,500.00
Totals: 0 $4,500.00
Units Unit Desc
1 SELECT
1 SELECT
1 SELECT
Printed By: AMB
Permit Total Fees:
Print Date:
0 $4,500.00
Fee Amount
$111.25
$4.50
$44.50
$160.25
3/27/2006
Project Number: 06000942 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 3/27/2006 Page 2 of 2
Notes: .-4 :.. .. W 0 . .:.,
Payment Summary:;152�� ;,....:,. 41-u a1iMal' W.s c..-..r1.C41. a: M
Permit Type
Building Permit
Fee Amount Invoice Amount Amount Paid Amount Owing
$160.25 $160.25
$0.00 $160.25
$160.25 $160.25 $0.00 $160.25
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB Print Date: 3/27/2006
Project Number: 06000942 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 3/21/2006 Page 1 of 2
Project Information: xsxs+, a M.EVT
Permit Use: FINISH BASEMENT: FRAME, INSULATE & Contact: FALK, WILLIAM & SHANNON
DRYWALL Address: 16309 E BROAD AVE
C - S - Z: SPOKANE, WA 99216
Setbacks: Front Left: Right: Rear: Phone: (509) 922-4682
Group Name:
Project Name:
Site Information:
. {.14 `✓ss15*.wa'."...:wN• T3,r.:;-P^c'r X',4g. b E^.1,,.Y,`Aac.
Plat Key: 005709 Name: CHINOOK NO 3 ADD District: H
Parcel Number: 46364.1002
Block: Lot:
SiteAddress: 16309 E BROAD AVE
Location:: CSV
Zoning: UR -3.5
Water District:
Urban Residential 3.5
Owner: Name: FALK, WILLIAM & SHANNON
Address: 16309 E BROAD AVE
SPOKANE, WA 99216
Hold: ❑
Area: 1,258.00 Acres Width: 125 Depth: 80 Right Of Way (ft): 50
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information: ,,,, ,,,.aa„prv,Tte.r.-raw,7serrommater,,Pr'. ^re.ttns .amAvv.: ,s.osr,nitmr
Review
Building Plan Review
Permits:
LA9Al7+'-E�7"'i"-••.^,-."::,14 7,7 Tr72 idAVIZIMMUNAVIM.',7 r,w,r7k. r'F%D4'rt4lti,4."YRw7'/re3" 2iiY 7 tiCOM"ai;�o,°'d'•I':r�'P,'4+f"rWWF,
Contractor: OWNER
Building Permit
Firm: OWNER
Phone: (000) 000-0000
This Application: Total Project:
Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation
GARAGE U-1 VB 413 $7,847.00 413 $7,847.00
Totals: 413 $7,847.00 413 $7,847.00
Operator: AMB Printed By: AMB Print Date: 3/21/2006
rfi
Permit Center
stri e
11707 E Sprague Ave, Suite 106
.0•Ovalley (S5p0o9k)a6n8e8-0036
(9590290)66 8 8 _ 0
Community Development www.spokanevalley.org
Residential Construction
Permit Application
MAR 21 2006,
NUMBER:CM 2...-
U_ \\ ER FEE:
New Construction
gAddition/Remodel
Other:
Accessory Bldg
Deck
SITE ADDRESS a ()DO CI
ASSESSORS PARCEL NO: 111- t, 3 4, o
/417 S,iju VLLL1'1 cA4
LEGAL DESCRIPTION: 411— 64--° ie:—.4.73 r2&_ /6
Building Owner:
DIMENSIONS:
Name: i/t) 'LA- I il ill 4• .kbit
F---nue--
Address: 1 b3Oq e--, 12,4M.7)
AKE,
City: ....c, pi iLttive im.12, State:
Zi • 9214,
Phone: 6 I,? ,, Fax:
City:
Contact Person
Name: 5 hi- tvAi' 0 N -Ffh—g--
Phone:
Describe the scope of work in detail:
Contractor:
DIMENSIONS:
# OF STORIES: /
Name:
MAIN FLOOR TO SQ.
1
FTG: a , 1,
2Nu FLOORSQ. FTG:
t
N, ,-4-
Address:
IMPERVIOUS t SURFACE
AREA: Ai +
FINISHED BASEMENT
SQ. FTG: k/L:3
City:
State:
Zip:
Phone:
Fax:
Contractor Lic No:
Exp Date:
City Business Lic. No:
Cost of Project: Web
)/1-1.Ch dZ,)-enle/ L'& /141 //v5/ Utz:17 n4/
**************The following MUST be complete: (write N/A if not a licable **********************
HEIGHT TO PEAK:
11 tr
DIMENSIONS:
# OF STORIES: /
TOTAL HAOITABLE_SPACE:
.7 6 t0,5' t7 Fr
MAIN FLOOR TO SQ.
1
FTG: a , 1,
2Nu FLOORSQ. FTG:
t
N, ,-4-
UNFIN BASEMENT SQ. FTG:
1/1
IMPERVIOUS t SURFACE
AREA: Ai +
FINISHED BASEMENT
SQ. FTG: k/L:3
GARAGE,SQ. FTG:
N : ,4
CO STRUCTION TYPE;
//JJ( (Le “ 17 1G(
DECK/COV.(PATIO SQ. FTG:
i1/4, . IA-
HEAT SOURCE:
.,:-;
30% SLOPES ON/ ," 4
PROPERTY: // I I/ I
SEWER OR SEPTIC?
,ce plit v --
# OF BEDR OMS:
V- iL&tLJ
The permitee verifies, acknowledges and agrees by their si nature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed.
Signature
Method of Payment:
ID Cash
Bankcard #:
Authorized Signature:
REVISED 8/25/2005
0 Check
El Mastercard 0 VISA
Expires: VIN#:
WSEC TABLE 6-2
PRESCRIPTIVE REQUIREMENTS"- FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
Option
Glazing
%Area1s:
of floor
Gazing U -Factor
Doors
U-
Ceiling2
Ceilings ulted
Ce
Ware
Above
Grade
Wali?
Below
Grade
Wall?
Below
Grade
Floors
Slabs
on
Grade
Vertical
Overhead"
Factor
I.
10%
0.40
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
II.
15%
0.40
0.58
0.20
R-38
R-30
R-19+
R-21
R-12
R-30
R-10
R -5s
III.
17%
0.37
0.58
0.20
R-38
R-30
R-19+
R-21
R-12
R-30
R-10
R -5s
IV.
25%
0.35
0.58
0.20
R-38 /
R-30 /
R-21
R-15
R-12
R-30 /
R-10 /
Group R-1
U=0.031
U=0.034
int' /
U=0.029
F=0.54
Occupancy
U=0.054
Only
V.
Unlimited
Group R-3
0.35
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
Occupancy
Ony
VI.
Unlimited
0.32
0.58
0.20
R-38 /
R-30 /
R-21
R-15
R-12
R-30 /
R-10 /
Group R-1
U=0.031
U=0.034
int' /
U=0.029
F=0.54
Occupancy
U=0.054
Only
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option (or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material, manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
WSEC Builder's Field Guide 5th Edition
COOPERATIVE EXTENSION
WASHINGTON STATE UNIVERSITY
ENERGY PROGRAM
1-7
Compass Construction Inc ESTIMATE
2420 North Wall St.
Spokane WA. 99205
(509) 879-5543
Fed. Id. # 91-1947756
Main Level
23'10'
11' 6'
7'8'
Osman
3'6'
8' 1"
3' 5'
%3'1'
closet (11r
1 4
Office
1'10'
do
4'8'
WINDOW WELL:
Min. 9 sq. ft. horizontal area.
SILK SHANNON Min. 3 ft. horizontal projection and width.
Max. 44 in. vertical depth without a ladder
7' 4
EMERGENCY EGRESS REQUIREMENTS
FROM SLEEPING ROOMS
1) NET CLEAR OPENING: 5.7 SQUARE FEET
GRADE FLOOR OPENING (MAX 44") 5.0 SQUARE FEET
2! NET CLEAR OPENING HEIGHT 24 INCHES
3! NET CLEAR OPENING WIuTH 20 INCHES
1 t MAX FINISHED SILL HEIGHT 44- ABOVE FLOOR
E MI RGE NCY ESCAPE & RESCUE OPENING SHALL BE
'i F.ATiJNA,L FROM THE INSIDE OF THE ROOM WITHOUT
vS OR TOOLS
SMOKE ALARMS SHALL. BE INTERCON-
NECTED AND HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24' & ON EACH FLOOR)
WHEN INTERIOR ALTERATIONS, REPN I OR ADDITIONS
REQUIRING A PERMIT OCCUR. OR WHEN ONE ON MORE
SLEEPING ROOMS ARE AIMED OR CREMEDN I DATING
DWELLINGS, THE DINELUNB UNIT SHALL RE PROVIDED
WITH SMOKE ALAS LOCATED AS REOUIIED FOR NEW
pW LUNGS.
EXHAUST FANS
100 CFM kitchen
50 CFM bathrooms
& laundry M -ret.
To �X T setc,0 iL
STAIRWAYS: Minimum width 36 in. with min. tread
run of 10 in., max. rise of 7 3/4 in. & nosing of 3/4-1 1/4 in.
Min. 6 ft. 8 in. headroom. Enclosed usable space under
stairways requires 1 hour fire protection of 1/2 in. GWB
HANDRAILS: Height of 34 — 38 inches when required by four or
more risers shall be continuous the full length of stairs with the
ends returned or rounded. LANDINGS: Required min. width of 36
in. or width of stairway and 36 in. travel distance
03/16/2006 Page: 5
Main Level
19-5
Page 1 of 1
http://roomplannenscripps.com/roomplanner/RpImageFromDB.asp?ImageName=249145... 03/20/2006