Loading...
2003, 07-28 Permit App: BD03-861 Ham Radio Tower;ity of Spokane Valley 1707 East Sprague Avenue, Suite 106 Dokane Valley, WA 99206 PERMIT #ig BUILDING PERMIT APPLICATION PHONE (509)688-0036 FAX # (509)688-0037 Box 1 OWNER 60c.c-. /1 i N JOB LOCATION I `�`��� OWNER'S ADDRES CITY PHONE DESCRIBE JOB ,-c..d -c, . 404 (,(y.JL PARTNERSHIP CORP. - THIS PROPERTY IS OWNED BY: SINGLE�.L�R1E- s--) BOX 2 CONTRACTOR'S NAME CONTRACTOR'S ADDRESS PHONE T'772s- zz. CITY CONTRACTOR'S REG.# EXPIRATION DATE (CARD MUST BE PRESENTED AND COPIED OR VERIFIED) BOX 3 CONTACT PERSON OF PROJECT PHONE ADDRESS CITY ZIP BOX 5 ESTIMATED PROJECT COST $ 70.00 EXISTING BLDG. VALUATION $ BOX 6 PROPERTY TAX ACCOUNT NUMBER LEGAL DESCRIPTION BOX 7 BUILDING SQUARE FOOTAGE (Existing / proposed) 1ST FLOOR / 2ND FLOOR / 3RD FLOOR / OTHER / BASEMENT FINISHED / BASEMENT UNFINISHED / DECK / GARAGE / CARPORT / TOTAL / HEIGHT TO PEAK OF BUILDING FT. BOX 8 ( ) SINGLE FAMILY ( ) NEW CONSTRUCTION ( ) MULTIFAMILY (NO. OF UNITS ) ( ) EXISTING STRUCTURE ( ) COMMERCIAL / INDUSTRIAL TOTAL AREA OF PROPERTY SQ. FT. ( ) TENANT IMPROVEMENT IMPERVIOUS SURFACE SQ. FT. I VERIFY UNDER THE PENALTY OF PERJURY THAT THE INFORMATION FURNISHED BY ME IS TRUE AND CORRECT TO TEST • Y KNOWLED ND FURTHER THAT I AM AUTHORIZED BY THE OWNER OF THE ABOVE PREMIS S TO PERFO THE W • ' K FOS HICH THE APPLICATION IS MADE. w OWNER / AGENT DATE 7-A5"--03 I hereby authorize the City of Spoke Valley to charge the fee for this permit to my credit card: Visa Mastercard _ _ _ _ Expiration Date Print the name of the Holder Signature 1220 N. Marcin St. Visalia, CA,•USA 93291 V, ®® T�C1 � , (3 FORMAL STRESS ANALYSIS DOCUMENT Self -Supporting Crank -Up Tower Structure Tower Model: TX -455 Phone: (559) 733-2438 Fax: (559) 733-7194 Design Specifications Meeting: 1997 Uniform Building Code (UBC) Design Wind Speed: 70 mph Basic 50 mph Basic Ice Loading: None None Exposure: B B Importance Factor: 1.00 1.00 Antenna Loading: Max. Projected Area (at l' above tower): With round elements 2"o and less With round elements > 2"o With Flat elements With 40% Flat & 60% Round elements Max. Antenna Weight: 12.3 sq. ft. 15.4 sq. ft. 9.5 sq. ft. 11 sq. ft. 200 lbs. 37.0 sq. ft. 46.3 sq. ft. 28.5 sq. ft. 33 sq. ft. 300 lbs. Notes: 1. Antenna areas indicated at 50 mph Basic wind speeds are for information only. The loads indicated within this analysis have been generated using the antenna area associated with 70 mph Basic wind speed 2. Analysis based on allowable stress design as defined by UBC -97 section 1602. 3. Analysis methodology uses fundemental concepts in statics equilibruim. The method of sections is used for analyzing tower members within the structural system. The results of our methodology has ir ® 1 -- been verified and checked with traditional hand calculations. < LU Z 4. Antenna mast and rotor weight are included in the weight of the top section. 7 N Z 5. Stress ratios are equal to the calculated stress divided by the AISC allowable stress. CO I- 0 6. This tower has been designed only for the antenna loads indicated within these calculations. Any a " Z • additional loads or differences in design criteria shall be brought to the attention of US Tower Corp. Z Z LU 7. The engineering and design of the antennas are beyond the scope of these calculations. o a F' O 8. All welds are performed by AWS certified welders utilizing ER70S-6 welding wire under a GMAW W P" O (spray Arc) welding process. CC `•I CC g. OOOOoC 9. US Tower Corp. recommends that the installation of this tower and its foundation be performed by a 1 !,.O !,0Professional, licensed Contractor with experience in installing these types of structures.''W++t 0VZ n10. This document is provided only for the use of obtaining builing permits and for tower design purpose D xwPlease refer to the installation drawings for all pertinent notes and details of tower and foundation O° ``®1. installation. 0 Q cc 6) It 2a0+-4 11. This analysis assumes the tower has been installed to US Tower specifications and is vertically plum CC W -4-, 61 aoE O 10/9/2001 Page 1 of 7 email: sales@ustower.com 1220 N. Marcin St. Visalia, CA USA 93291 a1 N co a) �CN e CO 0 tS co J c 0. v 0 z Pipe 1.05" OD x .113 wall 3/8" Solid Rod 0 z Pipe 1.05" OD x .154 wall 3/8" Solid Rod a) CO co 0 z Pipe 1.315" OD x .179 wall 7/16" Solid Rod Dwg. No. A-981069 A 55' 7041,Y/W4 A TOWER MODEL: TX -455 17' 17' 21' Elevation View No Scale Page 2 of 7 Phone: (559) 733-2438 Fax: (559) 733-7194 2" OD Tube Mast See Cover Sheet for Max. Antenna Wind Area @ 1 ft. above Top of Tower Design Criteria: Wind: 70 mph Basic Wind Speed Ice: None Design Codes: Structure: UBC -97 Div. III Sections 1615 Thru 1625 Exposure B Importance = 1.00 Steel: RISC 9th Edition Concrete: ACI 318-95 Materials: Steel Tube: ASTM A53 Gr. B or A501 Solid Rod: ASTM A36 Shapes/Plates: ASTM A36 Erection Bolts: ASTM A325 & SAE Gr. 5 Anchor Bolts: ASTM A36 Plan View No Scale www.ustower.com )220 N. Marcin St. Visalia, cA,ua*eoon1 Tower Section No. Section Length Face Width (in) Top Lap Length (ft) Bottom Lap Length (ft.) Lift Cable size (in) Top Plate depth (in) Bottom Plate depth (in) Plate Thickness (in) Leg properties: =3 IM:123 ‘2=. 4 5 6 21 21 21 11.47 13.96 16.68 0 4 4 4 4 O 0.25 0.25 0.25 4 4 4 6 6 6 0.25 0.25 0i25 be size, OD (in) 1.05 1.05 1.315 Wall thickness Un\ 0.113 0.154 0179 Pipe/Tube F.(koU 36 36 36 AUn2> 0.333 0.433 0.839 r (in) 0.334 0.321 0.407 LL (in) 15 15 15 0.9 0.9 0.9 KLLL/r 40.46 42.00 33.20 Co °^L 126.10 136.10 12610 Diagonal Properties: Rod size (in) RodF. Nu.of[�' Diag.s/section Di .|mclineong|a r (in) KrLr (in) Ccr Projected Wind Area: Leg EPA (sq. ft./ft] Diag.s EPA (sq. ft./ft.) Anchor Plates (»u.ft/ft.) Total Section w/o ice Section Weight: Legs (lbs.) Diag.s (lbs.) Anchor Plates (Ibs.) Cables & Pulleys (lbs.) Total Section Wt. 0.375 0.375 0.4375 36 36 36 32 44 44 25 21 16.5 0.110 0.110 0j50 0.094 0.094 0.109 0.8 0.8 0.8 11.50 13.83 16.02 98.11 118.00 117.21 126.10 126.10 126.10 1.95 1.56 2.14 0.12 0\12 0.15 0.032 0.052 0.071 0.038 0.044 0.053 0.184 0.214 0.270 71.2 92.7 136.7 34.5 57.1 90.0 30.4 37.0 44.3 20.4 28.0 40.6 157 215 312 Phone: (559) 733-2438 Fax: (559) 733-7194 Page 3 of 7 1220 N. Marcin St. Visalia, CA,•USA 93291 7/. Zr. Neerza-ezerzacel. 'edf /// -I' 0 w LJR% Tower Loading Calculations: Code: UBC - 97 Design Wind Speed: 70 mph Antenna Area: 12.3 ft2 (Factored Area) Importance Factor: 1 Antenna Weight: 200 lbs. (max. w/ice) Ice Loading: 0 in Cable Size: 0.375 (in) Structure Height: 55 ft. No. of Cables: 1' 100% Design Wind force without ice Phone: (559) 733-248 Fax: (559) 733-7194 Section Total Tower Section Projected Mid -Height Cq Ce go Base Shear Shear Moment Section Length (ft.) Area (ft.2) of Section (lbs.) (lbs.) (ft. - lbs.) Antenna 1 12.3 56 1 0.9 12.54 139 139 139 Mast & Rot. 1 0.670 55.5 1 0.9 12.54 7.56 146.43 143 4 17 3.132 46.5 3.2 0.87 12.54 119 265 3,644 Lap 4 & 5 4 1.591 36 3.2 0.81 12.54 55 320 4,815 5 13 2.776 27.5 3.2 0.75 12.54 90 410 9,561 Lap 5&6 4 1.933 19 3.2 0.66 12.54 54 464 11,309 6 17 4.587 8.5 3.2 0.62 12.54 121 585 20,221 Notes: 1. Antenna weight includes the weight of the antenna, rotor (if top mounted), and antenna mounting pipe. 2. The projected area includes the mast tube, lifting cable, and feedline cable(s) for each section TX-455-70mph_ExpB.xls Page 4 of 7 www.ustower.com '1220 N. Marcin St. Visalia, CA,•USA 93291 Analysis of Tower Sections Tower Section: Shear (Ib): Moment (ft -Ib): Panel Height (in): Lap length (ft): W2Z11 222221 NiZiZ2M2=1, •;//' IEVW/lEOR 4 5 6 265 410 585 3,644 9,561 20,221 15 15 15 4 4 0 Lift Cable Analysis: No. of Lift Cables 1 1 1 Pulley Frm Force (lbs) 713 1,499 Lift Cable Force (lbs) 357 928 Leg Analysis: Dia. (in): Wall Thk. (in): Compr. load (kips): Allow FaAL (kips): Leg F.S.: 1.05 1.05 1.315 0.113 0.154 0.179 4,521 9,800 16,798 8,493 10,996 16,786 0.53 0.89 1.00 Diagonal Analysis: Rod Size (in): 0.375 0.375 0.4375 Calc'd Load (lbs): 169 254 352 Allow. Load (lbs): 1,946 1,556 2,140 Diagonal F.S.: 0.09 0.16 0.16 Calc'd Load (lbs): 0.125 0.125 0.1875 Weld L (in.): 0.75 0.75 1 Calc'd weld load (#/in): 225 338 352 Allow. weld 'F' (Ib/in): 2,475 2,475 3,712 Diagonal Weld F.S.: 0.09 0.14 0.09 Phone: (559) 733-2438 Fax: (559) 733-7194 Diagonal Analysis - Lap Area (Note: Allowable loads based on reduction in unbraced member length) Lap Tower Sections Lap shear (lbs): Rod Size (in): Calc'd Load (lbs): Allow. Load (lbs): Diagonal F.S.: Weld size (in): Weld L (in): Calc'd weld load (#/in): Allow. weld 'F' (lb/in): Diagonal Weld F.S.: TX-455-70mph_ExpB.xls 4&5 5 & 6 1,176 2,800 0.375 0.375 452 1,063 2,548 2,361 0.18 0.45 0.125 0.125 0.75 0.75 500 1,155 2,475 2,475 0.20 0.47 Page 5 of 7 www.ustower.com '1220 N. Marcin St. Visalia, CA,•USA 93291 Tower -to -Anchor Bolt Interface Base Reactions: Overturning Moment (ft -lbs) Base Shear (lbs) Base Weight (lbs) Max. Compr. Force (lbs) Max. Tensile Force (lbs) Base Leg Tab Plate Analysis: Plate Width (in) Plate Height (in) Plate Thickness (in) Bolt diameter (in) No. of Bolts Ctr of Bolts to leg (in) Bolt Spacing (in) Weld Size (in) Weld Sx (in3) Weld Area (in2) Interface Tab Plate Analysis: Plate Width (in) Plate Height (in) Plate Thickness (in) Bolt eccentricity (in) Shear eccentricity (in) Dist. of first bolt to B.P. (in) 20,221 585 883 17,093 16,504 ft. -lbs. lbs. lbs. lbs. lbs. j i. •moi//off%%//� /u/wjEfri Base Leg OD 2.5 Plate Moment (in -lbs) 7 Plate Shear (lbs) 3/8 Plate Stress (psi) Force per Bolt (lbs) AIIow. Bolt Shear (Ib) AIIow. Bolt Brg. (Ib) - 3/4 3 1.25 2 3/16 2.17 1.86 3 1/2 7 3/4 3/8 0.5 4.5 2.5 Combined Stress Ratio Per Combined Stress Ratio Per Weld Size (in) Weld Sx (in3) Weld Area (in2) Interface Base Plate Analysis: Top Plate: 3 1/2 5 3/8 Plate Width (in): Plate Length (in): Plate Thickness (in): 0.3125 0.90 1.55 Weld Moment (in -lbs) Weld Shear (in) Weld Stress (psi) Kx rx_x (in) L (in) KxL/rx-x A (in`) b/t Fe' (psi) AISC eq. (H1-1) AISC eq. (H1-2) 1.2 0.11 2.50 27.71 1.31 9.33 194,442 1.00 0.84 Combined Stress Ratio: Bottom Plate: 3 1/2 5 1/2 Stress Ratio: 1.315 in Phone: (559) 733-2438 Fax: (559) 733-7194 32,604 (Bending about strong axis) 17,093 17,158 Plate Stress Ratio: 0.63 9,945 12,017 Shear Stress Ratio: 0.83 16,200 Brg. Stress Ratio: 0.61 32,604 17,093 17,652 Weld Stress Ratio: 0.63 Shear (lbs) 195 Axial Compression (lbs) 17,093 Moment (in -lbs) 9,424 fa (psi) 13,023 fb (psi) 12,308 Fa (psi) 20,100 Fb (psi) 31,680 <=== Governs - OK 0.75 < 1.00 (OK) Moment arm (in): Moment (in -lbs): Sx (in3): 0.90 < 1.00 (OK) TX-455-70mph_ExpB.xls Sheet 6 of 7 1.25 10,683 0.328 www.ustower.com • 41220 N. Marcin St. Visalia, CA, -USA 93291 Anchor Bolt Design: Anchor Bolt Embedment: Material: A36 Steel Anchor Dia. (in): 1 Rod Area (in2): 0.785 Fy (psi): 36000 Allow. Tension (lbs): 22,619 Phone: (559) 733-2438 Fax: (559) 733-7194 Anchor Embedment (in): 22 Conc. fc(psi): 2500 Pullout Capacity (lbs): 258,490 (OK) USE: 1 in x 27 in long Calc'd Tension (lbs): 16,504 (OK) A36 Anchor Bolts (or equivalent) Foundation Design: Ref. UBC -97 Section 1806 - Nonconstrained condition (1806.8.2.1) Moment: 20,221 ft. - lbs. Shear: 585 lbs. Allowable Lateral Soil Brg. (psf/ft): 266.67 Ftg. Width: 5 ft. (square) S1 (ft): 533.34 Ftg. Depth: 6.0 ft. h (ft): 35.1 Ftg. Proj.: 6 in. above grade A: 0.51 Minimum Depth Required by UBC: Lo = 4.7 ft. minimum USE: 5 ft. square x 6 ft. deep Footing Reinforcement Design: Factored Moment: 34,873 ft. - lbs. Fy(reinforcement): 60 ksi Bar Size: 9 fc (concrete): 2.5 ksi AS/bar: 0.99 in2 No. of Vert. Bars: 8 Min. Temp/Shrink. As req'd: 6.48 in2 d: 40.75 As provided : 7.95 in2 Nominal Moment: 181,232 ft. - lbs. (OK) L Anchor Bolts Vertical Bars #4 Ties 12" c -c USE: 8 - No. 9 A615 Gr. 60 vertical bars with 36" square ties at 12" c -c spacing Note: Ref. Foundation drawing for complete details for installing footing. TX -455-70m ph_ExpB.xls Page 7 of 7 www.ustower.com vertical bars 0 8 - #4 ties 2 @ Top Center of Footing Center of Tower 5' 5' Plan View No Scale Ire•••••'• 0 8 - #9 vertical bars 0 8 - #4 ties 2 @ top 5' Sqr. 6" AB Proj. Elevation View No Scale 8" Max. VIONNWio, Undisturbed Soil A 6' • Foundation has been designed to accommodate the following loads: Overturning Moment = 22.0 ft.- kips Base Shear = 0.77 kips Structure Weight = 0.90 kips Concrete volume is estimated at 6.0 yds. 24 1/16 22 9/16" --oc 21 3/16" Anchor Bolt Detail No Scale Hex Nut Base Plate 3 - 1" x 27" Anchor Bolts Anchor Bott Strike threads after tightening Hex nut to avoid loosening Grout beneath base plate after tower is installed 6" AB Proj. 2" Nom. Leveling Nut Grouting Detail Extreme care should be taken to assure that all leveling nuts are level with respect to each other prior to installation of tower Note: If leveling nuts used, grout not required, and reduce AB projection to 4". Reinforcement Material List Sym Type Bar Size Bar Spacing Dimensions Qty Weight (lbs.) a b c 10db (j) A #9 See Plan 6' - 0" -- - --- 8 163 lbs. (2) B #4 ' 12" 3' - 0" 3' - 0" 2" 5" 8 69 lbs. Type A Total Steel Weight for Complete Foundation Installation 232 lbs. A Ft% size was 3W sq. z 6W p. 21 Dec 00 REV. NO. DESCRIPTION OF REVISION BY ClikD BY DATE UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS IN INCHES. TOLERANCES: +1-1116" ON ALL FRACTIONAL DIMENSIONS +1-1/2 DEG. ON ALL ANGLE DIMENSIONS • , • US TOWER CORPORATION 1220 MARCIN STREET VISALIA CALIFORNIA93291 PHONE 559-733-2438 FAX 559-733-7194 SCALE None APPROVED REV. NO. A DATE CHKD. BY Us DATE 26 Sep 00 DRAWING TITLE Installation of Pier Footing TX -455 Crank -Up Tower DRAWN. BY AM DATE 26 Sep 00 DRAWING NO. A-200058 , t. FOUNDATION NOTES - GENERAL 1. US Tower Corporation highly recommends the customer obtain a Professonal, licensed, and insured Contractor for installing this tower foundation 2. The contractor is responsible for checking the area for underground facilities prior to excavating any soil material. 3. U.S. Tower Corporation or their Engineers accept no responsibility for field inspection during construction nor for the method of construction. This foundation may be inadequate if the ground water table rises into, and influences the strength of the surrounding soil. 4. Contractor shall use and provide deformed reinforcing bars conforming to ASTM A615 Gr. 60 (60,000 psi min. yield). Contractor shall use steel wire to tie reinforcing bars together. No welding shall be permitted on A615 reinforcing bars. If welding is preferred to hold the reinforcment cage together, ASTM A706 Gr. 60 deformed reinforcing bars shall be used. 5. Contractor is responsible for correct placement of anchor bolts. Anchor bolts must be plumb and shall be held with the projection as indicated (proj. tol. ± 1/2" max.). 6. Contractor shall use and provide concrete with a minimum compressive strength of 3,000 psi @ 28 days. Maximum concrete slump shall not exceed 6". Contractor to reference ACI "Building Code Requirements for Reinforced Concrete", ACI 318 latest edition for detailed concrete requirements. 7. Contractor shall place concrete against unconditioned soil to the depth indicated, and shall form above grade portion of foundation. Footing shall be a continous pour such that cold joints will not develop. The contractor is responsible for verifying adequate concrete coverage around reinforcement cage to avoid the potential for rebar corrosion. 8. The top of the footing shall be troweled level and smooth. Broom brushed surface texture permitted where preferred. 9. Actual footing dimensions may be slightly larger due to excavation methods and soil conditions. Rebar Bending & Lap Splice Requirements AG 318-89 Ppplicab e only to ASTM P615 Gr. 60 Rebar & 3000 psi Concrete strength Rebar Wt./ft. Std. Stirrup Vert. & Top Size Bend Bend Bottom Horiz. (lbs/ft) Diam. Diam. Horiz. Lap Lap Splice Splice #4 0.67 3" .. 2" 1' - 10" 2' - 5" #5 1.04 33/4" 2 1/2" 2'-3" 3'-0" #6 1.50 4 1/2" 4 1/2" 2' - 8" 3' - 6" #7 2.04 5 1/4" 5 1/4" 3' - 2" 4' - 2" #8 2.67 6" 6" 3' - 7" 4' - 8" #9 3.40 9 1/2" — 4' -1" 5' -4" #10 4.30 10 3/4" — 6' - 1" 7' - 10" #11 5.31 12" — 7' - 5" 9' - 8" For 2,500 psi concrete increase lap lengths by 10% For 2,000 psi concrete increase lap lengths by 25% THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION, AND SHALL NOT BE Uri 7 OR REPRODUCED OR ITS CONTENTS DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF US TOWER CORPORATION. B Added note 9. AM 11 Nov 00 A Added weldable rebar spec. AM 25 Sep 00 REV. NO. DESCRIPTION OF REVISION UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS IN INCHES. TOLERANCES: +1.1/16" ON ALL FRACTIONAL DIMENSIONS +/-1/2 DEG. ON ALL ANGLE DIMENSIONS US TOWER CORPORATION 1220 MARCIN STREET VISALIA CAUFORNIA93291 PHONE 559-733-2438 FAX 559-733-7194 BY CHID BY SCALE None DATE REV. NO. B APPROVED DATE CHID. BY US DRAWING TITLE General Notes for Crank -Up Towers DRAWN. BY AM DATE 5 Oct 99 DATE 2 Oct 99 DRAWING NO. A.991009