Loading...
1994, 12-01 Permit App: 94011860 ResidencePROJECT NUMBER= 94011860 APPLICATION DATE= 12/01/94 PAGE= 01 THIS IS NOT'A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 3104 S EARLY DAWN CT PARCEL#= 45263.1009PTN ADDRESS= VERADALE WA 99037 PERMIT USE= RESIDENCE/ATTACHED GARAGE - FORCED AIR GAS PLAT#= 005415 PLAT NAME= EVERGREEN POINT 8TH ADD BLOCK= 22 LOT= 15 ZONE= UR -3.5 DIST#= F AREA= 00013400 F/A= F WIDTH= 91 DEPTH= 1350 R/W= 50 # OF BLDGS= 1 # DWELLINGS= 1 WATER DIST = VERA OWNER= W R S & ASSOCIATES INC STREET= P 0 BOX 14084 ADDRESS= SPOKANE WA 99214 PHONE= 509 922 0782 CONTACT NAME= CAL SMITH PHONE NUMBER= 509 922 0782 BUILDING SETBACKS: FRONT= 30 LEFT= 8 RIGHT= 30 REAR= 40 ****************************** REVIEW INFORMATION •**************************** DEPARTMENT REVIEW REQUIREMENT BUILDING CONTRACTOR LICENSE REQUIRED COMMENTS: BUILDING PLAN REVIEW REQUIRED COMMENTS: LOS l°R-f- y' BUILDING SETBACK REVIEW REQUIRED COMMENTS: BUILDING of Pea Arri cfea S\ -r i , �.rJ � :2-a44.44,-1, 12.1 'gig q -I' -tig z J 2t -J}L[ ` CI)• 040 OvJ,0f7 APPRIt'CH/FLOOD PLAIN/DRAINAGE 1941 ITIOCXN (a(a'7 • " V SEWER PERMIT PENDING COMMENTS: ******************************* BUILDING PERMIT ******************************* CONTRACTOR= W R S & ASSOCIATES STREET= P 0 BOX 14084 ADDRESS= SPOKANE WA 99214 PHONE= 509 922 0782 NEW= X REMODEL= ADDITION= CHANGE OF USE= PROJECT NUMBER= 94011860 APPLICATION DATE= 12/01/94 PAGE= 02 DWELL UNITS= 1 OCCUP. LD= BLDG HGT= 17 STORIES= 1 BLDG W X D = 48 X 43 SQ FT= 2064 SPRINKLER= N REQ PARKING= #HANDICAP= CRITICAL MAT= N DESCRIPTION GROUP TYPE SQ FT VALUATION BASEMENT U R-3 VN 1521 16731.00 GARAGE M-1 VN 440 5280.00 RESIDENCE R-3 VN 1521 83655.00 ITEM DESCRIPTION QUANTITY FEE AMOUNT RESIDENTIAL VALUATION Y 660.50 STATE SURCHARGE Y 4.50 RADON MONITOR 1 12.57 SALES TAX 1 1.01 RESIDENTIAL SURCHARGE Y 118.89 ******************************* MECHANICAL PERMIT ***************************** CONTRACTOR= ALLIED HEATING INC STREET= 9309 E TRENT AVE ADDRESS= SPOKANE WA 99206 ITEM DESCRIPTION PHONE= 509 928 8252 QUANTITY FEE AMOUNT GAS APPLIANCE<=100,000BTU 1 12.00 GAS LOG OR GAS INSERT 1 10.00 GAS WATER HEATER 1 10.00 GAS PIPING 3 3.00 VENTILATING FANS 4 40.00 HEAT PUMP OR A/C 0-5 TONS 1 12.00 ***************************** PLUMBING PERMIT ****************************** CONTRACTOR= W R S & ASSOCIATES STREET= P 0 BOX 14084 ADDRESS= SPOKANE WA 99214 ITEM DESCRIPTION PHONE= 509 922 0782 QUANTITY FEE AMOUNT TOILETS/BIDETS 2 12.00 TUBS 2 12.00 SINKS 4 24.00 DISH WASHERS 1 6.00 CLOTHES WASHER 1 6.00 GARBAGE DISPOSAL 1 6.00 FLOOR DRAINS 1 6.00 WATER USING DEVICES 2 12.00 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING PROJECT NUMBER= 94011860 APPLICATION DATE= 12/01/94 PAGE= 03 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING BUILDING PERMIT 797.47 .00 797.47 MECHANICAL PRMT 87.00 .00 87.00 PLUMBING PERMIT 84.00 .00 84.00 968.47 PROCESSED BY: BURRIS, ROBIN PRINTED BY: BURRIS, ROBIN .00 968.47 ******************************** THANK YOU ************************************ Spokane County DEPARTMENT OF BUILDINGS West 1303 Broadway Avenue Spokane, WA 99260 -(509) 456-3675 PARCEL NUMBER: INFORMATION WORKSHEET q4-11gb0 STREET ADDRESS: CITY/STATE/.ZIP: SUBDIVISION: 3 1 o q 5 Ei L? J.)M cr, UES -PA /E. 1_<J,0 37 EveaG2 A.Q? tit -r- 8 411T0te1 BLOCK - LOT: 15 ZONE: DISTRICT: 50 LOT AREA: /3,14°0 F/A: WIDTH: 91, 8 / DEPTH: R/W: 5 # OF BUILDINGS: / # OF DWELLINGS: / WATER DISTRICT: 1%E'.4 OWNER: t04.$ *4'35CX. MAILING ADDRESS: CITY/STATE/ZIP: PHONE: 472.2. CONTACT: CAI . oA, l ! t,+1 SETBACKS: - FRONT: Zb LEFT: /O PERMIT USE: k►=.5 (Dan.t , ►'4- I PHONE: RIGHT: 3<) REAR: iJ ****************************************************************************** BUILDING INFORMATION CONTRACTOR LICENSE NUMBER: W R SA5 2 y 5 M G - CONTRACTOR: W 25 co-455cci 2 Jc MAILING ADDRESS: PHONE: ARCHITECT/ENGINEER: MAILING ADDRESS: PHONE: NEW: REMODEL: ADDITION: CHANGE OF USE: DWELL UNITS: ) OCCUPANT LOAD: BUILDING HGT: 1.T,_, STORIES: BUILDING DIMENSIONS: u8 x y3 (WIDTH X DEPTH) SQ. FT. 106Y REQUIRED PARKING: # HANDICAP: SPRINKLERED: CRITICAL MATERIAL: PLEASE PROVIDE THE FOLLOWING INFORMATION FOR ENERGY CODE COMPLIANCE: SPACE HEATING TYPE (Check One) FORCED AIR ELECTRIC ELECTRIC BASEBOARD OR WALL MOUNT FORCED AIR GAS HEAT PUMP PROPANE OTHER: r FLAT CEILINGS R 3 DOORS U ill VAULTED CEILINGS R SACA WINDOWS U ABOVE GRADE WALLS R 19 GLAZING AREA ' 35 % Jf BELOW GRADE WALLS TOTAL FLOOR AREA OF HEATED SPACE: FLOOR R SLAB ON GRADE R FURNACE EFFICIENCY RATING 84 PLEASE INDICATE ON YOUR PLANS: The location of the radon vent, and the location of the vent fan area. ******************************************************************************1 SQUARE FOOTAGE: MAIN FLOOR /5 2- SECOND FLOOR ••••••••••.., ""�.' BASEMENT : FINISHED UNFINISHED /5 �I GARAGE CARPORT DECKS ADDITIONAL AREAS: ****************************************************************************** LENDER/BOND HOLDER: ADDRESS CONTACT PHONE •1 PLUMBING PERMIT APPLICATION PROJECT ADDRESS: 1 9 ok-i C / OWNER: 1/l.1 S , MAILING ADDRESS: PHONE: CONTRACTOR: A C. T/ dm -f 2 .a MAILING ADDRESS: (street) (city/state) (zip) LICENSE: PHONE: (street) (city/state) (zip) SIGNATURE SPOKANE COUNTY DIVISION OF BUILDINGS WEST 1026 BROADWAY AVENUE • SPOKANE, WA 99260 • (509) 456-3675 WASTER FLUMI4tMJMD PLUMI3INU FIX DESCRIPTION LURES DETAIL # O1 UNITS mutat— nUBDDT COST /UNIT Bums AMOUNT 7, x S6 = $ 1 1 TOLD WATER CLOSETS, BIDETS URINALS - x $6 = $ B( TUBS BATH. JACUZZI, SPA, GARDEN 2-. x . $6 = $ BO5 SHOWERS (per trap) BASE, STALL, ON-SITE BUILD X $6 = $ SINKS LAVS/BASINS, BAR, FLOOR, KITCHEN. LAUNDRY, UTILITY. JANITOR, PHOTO, X—RAY, FOOD (PREP/CULINARY/MEAT) L-�- ( x $6 = • $ X47 DISHWASHER - ' x $6 = $ BOS CLOTHES WASHER - I x $6 = $ B0 GARBAGE DISPOSAL/GRINDER - 1 x $6 = $ 131O WATER SOFTENER - x S6 = S 1) ELECTRIC HOT WATER TANKS (NOTE: u gas water tank, see mechanical) X $6 = $ • . FLOOR DRAINS AREA, CASE, COIL, TRENCH. CONDENSATE 1 X $6 B • ROOF DRAINS/'OVERFLOW DRAINS (ea.) - x $6 = S $314 FOUNTAINS, DRINKING - X $6 = $ B15 WATER PIPING/DRAIN—WASTE—VENT INSTALLATION, ALTERATION OR REPAIR x $6 = $ 4.16 SEWAGE EJECTORS GRINDER, SUMP PUMP ', x $6 — $ {^ #:, WATER USING DEVICFS - COFFEE MAKER, HOSE BIB, S'' MER,PROOFBR, CARBONATOR, SWAMP COOLERS le x $6 = $ Bib Y�y;:;::::: CROSS—CONNECTION DEVICES VACUUM BREAKER. CHECK VALVE, AND R.P.B.P.D. FOR: VATS, SUMPS. TANKS, BOILERS, & SPRINKLER SYSTEMS x S6 = $ ,,;.: 110 INTERCEPTORS GREASE TRAP, SAND TRAP. CHEMICAL HOLDING TANK x $6 = $ 820 MEDICAL GAS (per outlet/bottle station) NITROUS. OXYGEN x $6 = $ 1321 MISCELLANEOUS FIXTURES x $6 = $ NOTE: MINIMUM PE I FEE IS $35.00 7) /11 ; _ . .% Subtotal PLUS: PROCESSING FEE $25.0( TOTAL PERMIT FEB DUE S SIGNATURE SPOKANE COUNTY DIVISION OF BUILDINGS WEST 1026 BROADWAY AVENUE • SPOKANE, WA 99260 • (509) 456-3675 WASTER FLUMI4tMJMD MECHANICAL PERMIT APPLICATION PROJECT ADDRESS: 3 IC -T OWNER: LC) k.'" MAILING ADDRESS: Cr (PHONE: j (street) CONTRACTOR: MAILING ADDRFSS: Att,_ea,.* Q 00 (**/ (city/state) (Zip) LICENSE: PHONE: city/state (zip) SIGNATURE: m=ster\mcthperm.hnd SPOKANE COUNTY DIVISION OP BUILDINGS WEST 1026 BROADWAY AVENUE * SPOKANE. WA 99260 • (509) 456-3675 DESCRILI1ON OF WORK # mum- OF UNITS _n.reot+r_ COST /UNIT lummu AMOUNT = or <100.000 j = $12 - s FUEL BURNING APPLIANCE B:t FUEL BURNING APPLIANCE >100,000 $15 - s ... Bf�sUNIdSTED PVEL BURNING APPLIANCE = or <400.000 s $50 - s S >400,000 = $100 - r UNLI5TI :D FUFI. BURNING APPLIANCE USED APPLIANCE (Must meet WSEC"s min. AFUE rating) - or <400.000 = $50 - s . USED APPLIANCE (Must meet WSEC"s min. AFUE rating) >400.000 = $100 - $ BOILER/REFRIGERATION 1-100M BTU = $12 - s BOILER/REFRIGERATION 101-500M BTU - $20 - s 131Q` BOILER/REFRIGERATION 501-1.000M BTU $25 - s • 011.}. BOILER/REFRIGERATION 1.001-1.750M BTU $35 - r• Sd`` BOILER/REFRIGERATION +1.75OM BTU = S60 - * GAS LOG GAS INSERT. AND/OR GAS FIREPLACE - ! = S10 - s RANGE - = $10 - s . DRYER - = $10 - s .: FUEL BURNING WATER HEA LER - i = S10 - s . MISCELLANEOUS FUEL BURNING APPLIANCE - $10 ..1$" GAS PIPING (ea. outlet) - S1 - s BBQ;: DUCT SYSTEMS - = S10 - s 20 VENTILATING FANS - = $10 - r 32I` AIR HANDLER (DOES NOT include duct systems) - or <10.000 CPM = S12 - $ # ' AIR HANDLER (DOES NOT include duct systems) >10.000 CFM = $15 82'' EVAPORATIVE COOLERS - = $10 - s ?l` TYPE I HOOD - ` $50 - s 2S` TYPE II HOOD - $10 - s ?, HEAT PUMP/AIR CONDITIONER 0-5TONS 1 = $12 # AIR CONDITIONER 6-0 TONS = S20 - s Ste; AIR CONDITIONER 16-10TONS $25 - s Z • AIR CONDITIONER 31-SOTONS = $35 - s B3Q AIR CONDITIONER +so TONS $60 - s i . LPG STORAGE TANK - S10 - s i332' WOOD OR PELLET STOVE/INSERT - = S25 - s Subtotal NOTA MINFMUMPE jvflT S $35. /1 PLUS: PROCESSING FEE $25 TOTAL PERMIT FEE DUE S SIGNATURE: m=ster\mcthperm.hnd SPOKANE COUNTY DIVISION OP BUILDINGS WEST 1026 BROADWAY AVENUE * SPOKANE. WA 99260 • (509) 456-3675 PLAT BOUNDARY 00 u7 lv� 91.81' ADDRESS: S '' 04. E ZONE: _LAX" ROAD ROAD WIDTH:.a5-O FRONT a RANKING: COMMENTS: REVIEWED COMMENTS_,,,. �1yA 3 tkJ 1 WISE ti3 GARAGE 440 ' UTIU EM ENT 20.29' i 30' BUILD IN G ;O :G) ••N :03 SETBACK W v` POND J2 ROPERTY LINE TYPE A CURB L=73.22' EARLY DAWN COURT 1 1 1 co 1 4 POND BOTTOM ELEV. =2016.10 RECEIVED APR 2 7 1994 ``;/ REVISED D14+5(o4 ON eZ t4) J'L kt1p-40514w/Says f e7P f2RM�RR4- 1 SPOKANE COUNTY STANDARD TYPE. "B" DRYWELL WITH TYPE 4 METAL FRAME AND GRATE STA -7+51.62- RT:--25'---------- GRATE EL= • • .60 21: 4 CURB DROP STA. 3+69.01 ELEV.=2017.60 T.C. 3/0q So. eiv2l.y 17Aw./ cr. LOT 15, BLOCK 22 EVERGREEN POINT 8TH ADDITION DATE: 4/21/94 SCALE: 1" =20' J INLAND PACIFIC ENGINEERING 707 West 7th • Suite 200 Spokane. WA 99204 (509) 458-6840 FAX (509) 458-684-4