Loading...
2013, 11-20 Energy Code4INGTON Mt%UN1VM1 Y txtr.N.Yoki Duct Leakage Affidavit (New Construction) Permit#: ,sa gc,7„ 433 House address or lot number: 006 ei I gb VL City: .S 4.(1.1 Cond. Floor Area (ft2): Zip: 9 9 e 3 7 Source (circle one): Estimated Measured 0 Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? 0 yes Vo Air Handler present during test? yes D no Circle Test Method: Leakage to Outside Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) = CFM@25 Pa Post Construction, leakage to outdoors: ((loor area x .04) = CFM@25 Pa Rough -In, total duct leakage with air handle tailed: (floor area x .04) = 74" CFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM@25 Pa Test Result: 6 7 CFM@25Pa Ring (circle one if applicable): Open Duct Tester Location: 2/4 1 2 Pressure Tap Location: 1 certify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name: R. e Technician: yin,/ it r, Technician Signature' Date: /./-0 Phone Number: vw--/veys"'" ,t),..ATliva, R&R Heating & Air Conditioning 5202 N Florida St. 2261 W Dakota Ave Tel (509) 484-1405 Tel (208) 765-9355 6,. V Spokane, WA 99217 Hayden Lake, ID 83835 '-7 Ca Fax (509) 483-5255 Fax (208) 719-0046 '9',* ,, 'ONDMOwww.RandRHeating.com ..) Property ...., Conditioned z..) c.Z., Builder or .,.... ,....., ;-• Signature: Address: iet.76. 5 , Covikk"- Floor Area 19 7- Date 7 / / (ef registered design professional : I. C.4) Ceiling: T.. ... ..., ,... .... ...„, Walls: Above Below, V Below, 7, -:.,'i-,,,,... .... NRFC rating .,.. Ia.) Default rating ....., I •.... , - ,.• ‘ ' - . Vaulted R- 3 Floors: Over unconditioned space R- Attic R- Llq Slab on grade floor R- grade R- 02 1 Doors: 4—,/6 R - int. R- R- R- ext. R- R- ' ," • , „,,,...;.„-:: '- U -Factors andSHGC (or) Windows U- , a SHGC- N/A : , (Chapter 10 WSEC 2009) Skylights U- SHGC- N/A , -,=:--v..4c, ,...,;:..,,,VI1..;';'. Hing, Mgr q9111! , 9nlgSPIPc watg 4) "t System Type Efficiency pj Heating force Air Ilea 1L vii , tCooling thrc-e S iiir,, #,ea -E /..i,,,t4p 1 SaiL 44 DHW 6/€c-iok... sit-,-afe... eti er All ducts NI 1*-- Test Method: 0 NI Test Target 01w:.0004g-4iroiticoge & HVAC in conditioned space: (yes e Insulation ?(Total leakage Leakage to exterior X Air handler 7Z( CFM@25Pa Test Result 6 7 CFM@25Pa R- 8 present (Building System type: Tested CFM50 i OS q 13 02 CFM50 x 60) / ( ig 15 2f0) ACII,,, = _Lf trOlivided by ig 62. ft3 LI. air leakage target: ACH50 < 5.0) — Tested ACH50= OrisiteRerfekafileEtiergyTlectm Poltivr,,,Vsfrifi Rated annual generation '''.' , --:,:, Kwh V Ii1TE CCPV TO C'U3'OI.IER - YEL_OW COP" TO (DNTP.ACTU? • SHARD CCPY TO ARIC FART ' R es den..e Address '� cis r� civ Cap"- i ;}'.r► LOOSE -FILL INSULATION CERTIFICATE ed Date ,nstali SPECIRL/ZED I SSULATIDN a srO£Nrun ' COMMEriC/RL so9.40g.351a S94 cOZZA ❑RIVE SParcarr., VVA 99203 Carar. I_tc. SPEc111939D PART 2 f Scuare Feat F Existing R -Value Ceiling Areas •7'51,1aed (Loose Flifi G9 Added R=Value No. Begs Lbs. Bag 2• I3. Total Depth 17 Combined I Insulation R -Value Type .4(405I PART 3 Square Feet I Existing R-ValLe ❑ v l Area �rula:ed (loose Fill) U Floor Areas Insulated 1 Added R -Value No. Bags Lbs. Bag I Total Dept, j Conbined R -Vacuo Insulation Type This cert;fied that the above rasidence Ident!flen in Pan 1 was insulated as specified in Part < or 5 and the inele &tion wea conducted in conformance to appi.r;able codes, stanca-ds and mutations at t -.e tuna of Instatlat ore. WHITE CORYTO CUSTOMER' \'EU-OwN ^CP"Y TO CONTRACTOR • HARD CGP' TOATTIC F (.A. rHOR'2ED SIGNATLREt