Loading...
HomeMy WebLinkAbout1991, 12-09 Permit App: 91008493 ResidenceSPOKANE COUNTY 'DEPARTMENT OF BUILDINGS W. 1303 BROADWAY AVENUE SPOKANE, WASHINGTON 99260 (509) 456-3675 I certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said permit/application is true and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local laws regulating construction. SIGNATURE OF OWNER OR AGENT DATE APPLICATION PROJECT NUMBER= 91008493 APPLICATION DATE 12/09/91 PAGE= **3i3i•3i* THIS IS NOT A PERMIT 3p;•*3i•*** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE:: STREET= 15318 F 22ND AVE PARCEL..: =: 26544-1220 ADDRESS:::: VERADALE WA 99037 PERMIT USE= RESIDE:NCE Wr'GARr=IGE: -• GAS PLATO= 00 092 P1..AT NAME= AUTUMN CREST 2ND ADD BLOCK= 1 1...OT=-: 3 '.ONE= UR :L5 T)1. rTn: ' F AREA= 00000000 F/A= F WIDTH:: Tao DEPTH= 130 R/W= '";0 4 OF' BLDGE= 1 4 DWELLINGS= 1 WATER DIST :~= VERA OWNER= LANDRETH CONSTRUCTION PHONE= 509 535 7778 STREET= 3124 .`.'. REGAL.. .SST 4100 ADDRESS-- SPOKANE WA 99223 CONTACT NAME= RON SOSS,[ PHONE NUMBER= 509 535 7778 BUILDING SETBACKS: FRONT= .:30 LEFT= 16 RIGHT= 7 REAR= 59 ***-*******k•*3i********3i•***•***:». REVIEW INFORMATION ********************=x•*3*** DEPARTMENT REVIEW COMMENTS APPROVAL. COMMENTS BUILDING PLAN REVIEW REQUIRED- /ee:/247-91 BUILDING SETBACK R `,,e EW R:EOUTRE:D PLAIN/DRAINAGE a, . ._ ...... �.v?-l/.:,i.. ENGINEER AFCROACHI-LOOD �.+/a%0 ********:**''r.•***k*#*d ***3i•*** :i.l:Ii...:(1EN(; PERMIT*****i':*»•***••*3i•3i•***n:****3i•3+3in3i• CONTRACTOR= LANDRETH CONSTRUCTION INC • PHONE.:: 509 535 7778 STREET= 3124 S RE::GA1... ST :100 S= ADDRESSPOKANE Writ 99223., NEW= X REMODEL= ADDITION-: CHANGE OE USE:: DWEI...L. L.JN:ETS= 1 OCCI.JP (...D= BL.DC9 HG T= 15 STORIES- BLDG W X i) a:: r) f 41 SC; FT= 3030 SPRINKLER= N REQ PARKING:::: 4L:HANDICAF':::: CRITICAL MAT::- N •******•**•x•******3f***:***3k3i****** iME:CHANIfA1... PERMIT **3i•********ii•**3r'N:'****•3t*N,3i•'Hi:a• CONTRACTOR::' WYATT' S HEATING ,r,, AIR COND STREET=: p 0 BOX 11.02 ADDRESS= SPOKANE WA 99211 PHONE= 509 :'s 9427 *****:x*****************3i•3i••***3r F1...UHEtING PERMIT:***3•:**'n***•*****Mi*******•**i'i**** CONTRACTOR= GATEHOUSE: F'L_UMT.•.tING STREET= PO BOX 000 ADDRESS= CHATTAROY WA 99003 PROCE:SSE:I? BY: JULIE SHATTO PRINTED BY: JULIE SF•lnTTO PHONE::: 509 23A 9132 ar; ;•*:***3i****3i****'H*****3i••:*******•* THANK YOU********'x•***************.********* 14'5e, S(c, SO ,66 90p - THESE PIANS HAVE BEEN P.R/T+ i AL -T RA.beI Sy4T BY 4/ - -. -57- 1-7-9i s + basement s • • a • • • •• • E 1 531 8 22nd Autumn Crest, off Sullivan Radon Vent r • • • • • garage 41 ((artlifr hrpuralitin E. 8620 11th Spokane, IJa . 99206 Phone 509 926-621 7 Fax 509 928-8689 Legend for Radon mitigation system -perforated pipe beneath slab Q solid 1"ABS stack vent pipe RADON SYSTEM SPECIFICATIONS ATT RADON MITIGATION SYSTEM This radon mitigation system is designed only for the specific Job - site address designated. The system is not guaranteed unless installed by Cavalier Corporation Job s[e address E 1 531 8 22nd budder Landreth Sq Ft 1800 rAicehAtb.% Warre 4•,R.M _ate Environmental Protection Agency RCP '10044 Spokane County DEPARTMENT .OF BUILDING & SAFETY West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675 INFORMATION WORKSHEET PARCEL NUMBER: STREET ADDRESS: At, A g A_ (AE._ CITY/STATE/ZIP: V a\r.f r_^0Th SUBDIVISION: /� �.t� (.4 iN C .uc ri �t:- r` ®IL) BLOCK: / LOT: 3 ZONE: DISTRICT: LOT AREA: /0140 F/A: WIDTH: CO DEPTH: /3c R/W: # OF BUILDINGS: # OF DWELLINGS: WATER DISTRICT: OWNER: C_.OA)S i ra c (_;,.- ' PHONE: -sr3S- 777Ss MAILING ADDRESS: 3 R.4 4C.01“--/ /00 CITY/STATE/ZIP:� pNE 0...,V\ . 3 2 CONTACT: ?C n-) ata S PHONE : v - 5'- 777 SETBACKS: - FRONT: 30' LEFT: ICa RIGHT: 1 REAR: S� / PERMIT USE: **************************************************************************** BUILDING INFORMATION CONTRACTOR LICENSE NUMBER: CONTRACTOR: `--4,-/v PHONE: 50/1 -Sas - r77 S MAILING ADDRESS: (.2C„A�C._ � vt:�c la Sc,Y, 2_ � f ARCHITECT/ENGINEER: MAILING ADDRESS: S- 31� PHONE: % - .3".3S' - 17 6, 3 NEW: y REMODEL: ADDITION: CHANGE OF USE: DWELL UNITS: OCCUPANT LOAD: BUILDING HGT: STORIES: BUILDING DIMENSIONS: f X (WIDTH X DEPTH) SQ. FT.: x37 REQUIRED PARKING: # HANDICAP: SPRINKLERED: CRITICAL MATERIAL: Please provide the following information for Energy Code compliance: Space heating type (check one) Forced air electric Electric baseboard or wall mount Propane X Forced air gas Heat pump Other: Flat ceilings R Vaulted ceilings R 3() Above grade walls R Below grade walls R 16\ Floor R 3 b Slab on grade R !m Doors U (Y12 - Windows U • Glazing area Total floor area of heated space 3030 Furnace efficiency rating 6D -F- Please indicate on your plans: The location of the radon vent, and the location of the vent fan area. Square footage Main floor: 1 c t 5� Second floor: Basement - Finished: Unfinished: I 1--(5-. Garage: -("7 Carport: Decks: 1 D _ Additional Areas: CURS • ti ZZ &R AVE. 0 11 R08 POND (see B,4 K) 3' CUR8 DROP ‘t°'------ DRA./NAGE IIT/G/rV 4- 4$ 41 N7_ �--- 86"b D I /i4 SETBAIX 741. EASEMeNT re/WPOR.4Ar S/ SW.-4GE (SES' BALK) M/N. sc ov' 70 SD.00 i i 0 LOT 3 BLOCK . 1 AUTUMN CREST SECOND ADD P) SCALE: I".1 zo` .,. 7 Z," 5-1rry 05 Z S ' 22.5' �c 5ra. FoR CB ORJF 540,= 5; Dc5 3 / .cf4,f. t.ca DRJP,')I £r Sc £ OfrAi PLAN - TYPICAL SWALE DETAIL 'L5. 70' YAR/ES ..1:/ MAX. I o5 L P/6' /in ORA/NAGE EA5EMENt SWALE SECTION A -- A /01 ORA/NAGE EA St-MIA/7 4-, I s' EX/S/ GROUA/D? /.r5. • I TYP'/GA4 TEMPORARY DRAINAGE SWALE SECTION "D" - A/ r 5. Ixrntier engineering radon services E. 8620 44th s Spokane, WA 99206 Phone (509) 926-6217 FAX (509) 928-8689 RADON SYSTEM SPECIFICATIONS, SPOKANE COUNTY: 1. Perforated pipe shall be installed within the native soil or fill (sand, gravel or soil) at a minimum depth of 1" below the intended slab. 2. The pipe shall be a minimum diameter of 4". meet AASHTO M252, have perforations no wider than 1/16" and have a minimum of 2.5 square inches of total perforations per linear foot of pipe. 3. There shall be a minimum of 10 linear feet of perforated pipe per hundred square feet of slab floor space. 4. The pipe shall be laid in a continuous loop. connected at both ends to the solid stack vent pipe. 5. Any slab area, which is larger than 10 square feet, which is isolated from other slab areas by footings or other barriers, shall have a perforated pipe installed to the above specifications. (The pipe can be a single length rather than a connected loop if the area is too small or narrow to accomodate a connected loop.) 6. A stack vent of ABS, schedule 40. minimum size 4", shall be connected to the sub -slab piping and proceed upwards to an exit location on the roof. and extending 14" above the roof. The pipe shall be labeled "radon vent" every 16" or less for its full length. The pipe's attic location shall allow a minimum of 4' of head room. When- ever possible this exit location shall be on the backside of the roof. 7. Any elbows in the stack vent piping shall have a centerline radius minimum of 1.5 by pipe width. 8. An inline centrifugal fan, minimum 114 cfm @ 3/8" W.C.. UL listed, manufactured specifically for radon mitigation, maximum sone level 2.8, shall be installed in the exhaust line, in the attic. 9. Couplings to connect the vent piping to the fan shall be elastomeric PVC, Fernco series 1056 or equal. 10. The fan shall be hard -wired and the breaker labeled "radon fan". 11. All penetrations and joints in the concrete floor slab below grade shall be sealed with caulk or grout. 12. A notice shall be permanently attached to the electrical panel advising the owner or occupant about the radon system and that he/she shall test the home for radon annually. The notice shall include Cavalier's name and, phone number. 13. All craftsmanship shall be of high quality.