1992, 03-24 Compliance ReportWATTSUN 5.2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT 03/24/92
FILE: C:\WATTSUN5\DR#301.WS
Site: 15725 EAST 22ND CT
VERADALE, WA 99037
( ) -
Homeowner:
( )
Builder: TDC
HOUSE ID: DR#201
Analyst: MICHAEL DeVLEMING
Jurisdiction: SPOKANE COUNTY
Utility: VERA WATER & POWER
House Type: Single Family
Floor Area: 2608 ft2
Weather Data: Spokane, WA
Climate Zone: 2
The PROPOSED design QUALIFIES for SGC(91 MCS) Tier 1.
COMPONENT PERFORMANCE
ENERGY BUDGET
REFERENCE
447
4.76
PROPOSED
447 Btu/hr-F
4.90 kWh/ft2-yr
REFERENCE DESIGN
Component
Description
Reference
Value X
Area = UA
BG Wall 3.5'
BG Slab 3.5'
Floor
Glazing @15%
Doors
AG Wall
Ceiling, Attic
Ceiling, Vault
Infiltration
R23. batt 3.5' w/TB
R30 vented joist
0.35 U -value
Metal R5 base case
R21+R5 ADV
R49 blown Attic ADV
R38 batt vault vented
Standard air sealing
U-0.038
F-0.627
U-0.029
U-0.350
U-0.190
U-0.041
U-0.020
U-0.027
ACH-0.350
532 20.2
152ft 95.3
30 0.9
391.2 136.9
38.0 7.2
1427 58.5
703 14.1
621 16.8
16000ft3 96.9
Reference UA
447
PROPOSED DBSIGN COMPONENTS
Component
Description
Value X Area = UA
BG Wall
BG Slab
Floor
R21 Batt 3.5' depth
R30 vented Joist 16oc
U-0.038
F-0.627
U-0.029
532 20.2
152ft 95.3
30 0.9
Items in parentheses not included in COMPONENT PERFORMANCE totals.
** Denotes non-standard values - check calculation of thermal value.
* Denotes adjusted UA to reflect 7-1/2 mph wind speed.
Page 1
WATTSUN 5.2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT 03/24/92
FILE: C:\WATTSUN5\DR#301.WS
HOUSE ID: DR#201
Glazing @10%
Doors
AG Wall
Ceiling
Infiltration
Struc Mass
**2 -GLAZE, VINYL FIXED W/ARGON-WP
**2 -GLAZE, VINYL SLIDER W/ARGON-WP
**2 -GLAZE, VINYL FRENCH DOOR
Metal R-5 base case
R21 INT T1-11
R21 INT Lap Wood
R38 blown Attic STD baffled
**R-38 BLOWN VAULT 3.5" HEEL
Standard Air Sealing
U-0.360
U-0.360
U-0.450
U-0.190
U-0.056
U-0.054
U-0.031
U-0.033
ACH-0.350
82.0
151.0
40.0
38.0
1081
464
703
621
16000ft3
28.7*
52.8*
17.2*
7.2*
60.5
25.1
21.8
20.5
96.9
Proposed UA
Light Frame, Sheetrock walls M- 3.000 1318
Slab w/carpet w/pad, Sheetrock wall M- 5.000 1290
447
3954
6450
HEATING/COOLING/VENTILATING SYSTEMS
Heating System Type:
Make:
System Efficiency:
Modified Efficiency:
Design ACH:
Heating Load(at 66F dt):
System Size:
Maximum Size @150%:
Auxiliary:
HP Balance Point:
Average Annual Heat:
Annual Cost:
Ventilation System:
Cooling Load(at 12F dt):
Recommended Size @1250:
Solar Access:
PROPOSED
Heat Pump: Air Source
HP Air Source Default
6.8 HSPF
173 %
0.60
35173 Btu/hr
27.8 kBtu/hr at
15.6 kBtu/hr at
15.5 kW
7.0 kW
27 F
8951 kWh
$ 340
Integrated w/Forced
Air Furnace
17605 Btu/hr
2.0 tons
Partially Shaded
47F
17F
PROPOSED DUCT SYSTEM
SUPPLY
RETURN
Location
Avg Rvalue
Surface Area
All in heated space
All in heated space
R- 8.0
R- 8.0
521.6 ft2
104.3 ft2
Page 2
� r
WATTSUN,5,.2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT 03/24/92
FILE: C:\WATTSUN5\DR#301.WS HOUSE ID: DR#201
GLAZING ORIENTATION
South:
Southeast:
East:
Northeast:
PROPOSED
165.0 ft2
North:
Northwest:
West:
Southwest:
PROPOSED
108.0 ft2
Economic and energy consumption estimates are designed for comparative
purposes only. Actual cost for heating will vary depending on weather
conditions, occupant lifestyle and other factors.
Page 3
NORTH 601 EVERGREEN RD.
P O. BOX 630
VE.RADALE, WASHINGTON 99037- 0630
March 24, 1992
Marty Robinson
Department of Buildings
811 North Jefferson St.
Spokane, WA 99260-0180
D ;irrbubrs of Water & Power
Telephone 924-3800
_Z5-^1
Dear Marty:
The dwelling structures at 15725 East 22nd Ct. and 2205 South
Timberlane listed on the attached information packet has been
reviewed by the undersigned and meets the Super Good Cents
qualification criteria for the Component Performance approach
using the WATTSUN5.2 computer program.
In order to meet the Energy Budget requirements, a heat pump
with a minimum of 6.8 H.S.P.F. rating will be required, and the
Ventilation System Specifications must be complied with.
I have sent a copy of this report to Dave Renz of T.D.C. and
instructed him that he needs to bring you copies of the plans
A.S.A.P.
Sincerely,
VERA W
Michael ieVleming, Director
Energy Management Services