1992, 08-14 Good Cents Compliance ReportWATTSUN 5.3 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 08/14/92 FILE: C:\WATTSUN5\KM#303.WS HOUSE ID: KM#303 Site: 15920 E. 22ND CT. VERADALE, WA 99037 ( ) - Homeowner: Builder: KEVIN MADDEN CONSTRUCTION Analyst: Jurisdiction: Utility: House Type: Floor Area: MICHAEL DeVLEMING -1IYJ SPOKANE COUNTY VERA WATER & POWER Single Family 4050 ft2 Weather Data: Spokane, WA Climate Zone: 2 The PROPOSED design QUALIFIES for SGC(91 MCS) Tier 1. COMPONENT PERFORMANCE ENERGY BUDGET REFERENCE 593 4.24 PROPOSED 590 Btu/hr-F 4.53 kWh/ft2-yr REFERENCE DESIGN Component Description Reference Value X Area = UA BG Wall 3.5' R21 batt 3.5' w/TB BG Slab 3.5' BG Wall 7' R21 batt 7' w/TB BG Slab 7' On Grade Slab Floor Glazing @15% Doors AG Wall Ceiling, Attic Infiltration R15 2' horizontal w/TB R30 vented joist 0.35 U -value Metal R5 base case R21+R5 ADV R49 blown Attic ADV Standard air sealing U-0.040 F-0.556 U-0.035 F-0.503 F-0.520 U-0.029 U-0.350 U-0.190 U-0.041 U-0.020 ACH-0.350 70 2.8 20ft 11.1 1337 46.8 191ft 96.1 17ft 8.8 50 1.4 607.5 212.6 56.0 10.6 1296 53.1 2050 41.0 18000ft3 109.0 Reference UA 593 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall R19 Batt 3.5' depth U-0.041 70 2.9 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. * Denotes adjusted UA to reflect 7-1/2 mph wind speed. Page 1 WATTSUN 5.3 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 08/14/92 FILE: C:\WATTSUN5\KM#303.WS HOUSE ID: KM#303 BG Slab BG Wall R19 Batt 7' depth BG Slab On Grade Slab R10 2' vertical Floor R30 vented Joist 16oc Glazing @8% **2 -GLAZE, VINYL FIXED WP **2 -GLAZE, VINYL SLIDER W/ARGON-WP **2 -GLAZE, PATIO SLIDER Doors Metal R-5 base case AG Wall Ceiling Infiltration Struc Mass R19 INT T1-11 R19 INT Lap Wood R38 blown Attic STD baffled Standard Air Sealing F-0.625 U-0.036 F-0.554 F-0.540 U-0.029 U-0.490 U-0.350 U-0.480 U-0.190 U-0.061 U-0.058 U-0.031 ACH-0.350 20ft 1337 191ft 17ft 50 67.1 198.4 73.0 56.0 1064 501 2050 18000ft3 12.5 48.1 105.8 9.2 1.4 31.5* 67.5* 33.6* 10.6* 64.9 29.1 63.5 109.0 Proposed UA Light Frame, Sheetrock walls M- 3.000 2050 Slab w/carpet w/pad, Sheetrock wall M- 5.000 2000 590 6150 10000 HEATING/COOLING/VENTILATING SYSTEMS Heating System Type: Make: System Efficiency: Modified Efficiency: Design ACH: Heating Load(at 66F dt): System Size: Maximum Size @150%: Auxiliary: HP Balance Point: Average Annual Heat: Annual Cost: Ventilation System: Cooling System: SEER: Cooling Load(at 12F dt): Recommended Size @125%: Annual cool requirement: Solar Access: PROPOSED Heat Pump: Air Source HP Air Source Default 6.8 HSPF 176 % 0.60 45252 Btu/hr 36.3 kBtu/hr at 47F 20.6 kBtu/hr at 17F 19.9 kW 9.0 kW 27 F 12741 kWh $ 484 Integrated w/Forced Air Furnace 0.0 (Unducted) 24068 Btu/hr 2.8 tons *** kWh/yr Partially Shaded Page 2 WATTSUN 5.3 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 08/14/92 FILE: C:\WATTSUN5\KM#303.WS HOUSE ID: KM#303 PROPOSED DUCT SYSTEM SUPPLY RETURN Location Avg Rvalue Surface Area All in heated space All in heated space R- 8.0 162.0 ft2 GLAZING ORIENTATION PROPOSED PROPOSED South 185.4ft2 North 97.1ft2 Southeast : 10.0 Northwest : East • 20.0 West • 16.0 Northeast : Southwest : 10.0 Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. 1. ,, 0,530 July 14, 1992 Randy Vissia Department of Buildings 1303 West Broadway Ave. Spokane, WA 99260-0180 Dear Mr. Vissia: C%,stn.)i,r ,r of ll-oter .4 Puwer The dwelling structure (15920 East 22rd CT) listed on the attached information packet has been reviewed by the undersigned and meets the SUPER GOOD CENTS/WSEC qualification criteria for the Component Performance approach using the WATTSUN5 Computer Program. In order to meet the SUPER GOOD CENTS/WSEC specifications, all fixed glazing will be required to be filled with Argon Gas. WSEC ventilation requirements will also need to be met. Sincerely, VERA WATER & PO --'\N\;c4P—Aii\ c\°) Michael DeVleming, Director Energy Management Services enclosure cc Kevin Madden (Kevin Madden Construction)