Loading...
2015, 02-19 Permit App: BLD-2015-0297 Egress WindowSpokane Community Development Department Permit Center 11703 East Sprague Avenue, Suite B-3 Spokane Valley, WA 99206 Tel: (509) 688-0036 Fax: (509) 688-0037 permitcenter@sookanevalley.ord (Staff Use Only) PERMIT NUMBER: PERMIT FEE: RESIDENTIAL CONSTRUCTION PERMIT APPLICATION NEW CONSTRUCTION [1 ADDITION/REMODEL ❑ ACCESSORY BUILDING ❑ DECK ❑ OTHER SITE ADDRESS: 1 .,) U i 7 a ✓a iJ T o kr-1 a ( /e-47 9 / (o ASSESSORS PARCEL NO.: LEGAL DESCRIPTION: BUILDING OWNER NAME: NAME: ,O , Yt • W i /7-1 ADDRESS: CITY: STATE: l.UOL ZIP: q PHONE: S�j (� , 9S-1 -S'// U FAX: CONTACT NAME: CELL: PHONE: FAX: CONTRACTOR NAME: c iLTj a ct # IS D-. Q015-03)9 RECEIVED O MAILING ADDRESS: E' r Cc) r, vA rut C' : ti n CITY: ©k/iy.t STATE: PHONE: y-4 - 26 FAX: CONTRACTOR LICENSE No.: Sctre x....94/EXPIRES: CITY B FEB 192015 CiTPERMIT CENTER 1 CELL' j -SUB # [ REV. # DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE: ****YOU MUST COMPLETE THE FOLLOWING**** MARK N /A IF NOT APPLICABLE Height to Peak: Dimensions: No. of Stories: Total Habitable Space: Main Floor SQ FT: Upper Floor SQ FT: Unfinished Basement SQ FT: Finished Basement SQ FT: Garage SQ FT: Deck/Covered Patio SQ FT: Impervious Surface Area: 30% Slopes on Property: No. of Bedrooms: Construction Type: Heat Source: Sewer or Septic: TOTAL COST OF PROJECT: $ DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subsequently approved before this application can be processed. Signature Date: eg/ ? //,i ' Updated 1-11-11 Page 1 of 1 http://www.spokanevalley.org/filestorage/124/938/210/948/1496/Building_Permit_ _Residential_11-11-11.doc it TOP L 60er REVIEWED FOR CODE COMPLIANCE SPOKANEr LLEY BUILDING +MSION 411, AXIL FILE 30;5 x 47.5 NET casement window with egress hardware installed as per egress 60" deep well to maintain space betwee dirt -and bottom of -finished -trim of winder ;well to be concrete anchored with 6318"x3" concrete anchors 2x6 treated lumber frame to be built around new window and anchored to concrete ;cut will follow existing window width down to 48" floor joist: 2"x10"x1:3' 16"o.c runnig toward existing windo ject RECEIVED FEB 192015 CSV PERMIT CENTER SUB# j RE\I, S�1s!.00°N/alley EMERGENCY ESCAPE AND RESCUE EGRESS WINDOW *Minimum 20" wide clear opening *Minimum 24" high clear opening *Minimum 5.7 sq ft openable area **5.0 sq ft minimum @ grade floor *Top of sill maximum of 44" above finished floor .-- 20" CLEAR I MIN /,,, OPENABLE AREA 5.7SQFTMIN -(5.0 SQ FT MIN @ GRADE FLOOR) • • • • • MINIMUM SIZE WINDOW FOR 20 IN. CLEAR WIDTH 41" CLEAR SILL HEIGHT 44° MAX 34° CLEAR OPENABLE AREA 5.7 SQ FT MIN (5.0 SQ FT MIN @ GRADE FLOOR) • • MINIMUM SIZE WINDOW FOR 24 IN. CLEAR HEIGHT 24" CLEAR MIN FLOOR Grade floor opening is a window or other openings located such that the sill height of the opening is not more than 44" above or below the finished ground level adjacent to the opening. WINDOW WELL *Minimum 36" x 36" *Minimum 9 sq ft clear floor area *Top of wall a maximum of 44" above the floor of the well *A guardrail is not required unless an exit way adjoins the well. *Provide drainage DEEP WELLS *If the top of the window well wall is more than 44" above the floor of the well, either a permanently fixed ladder or stair egress is required. *The ladder or stair may encroach a maximum of 6" into the required clear floor space. WINDOW WELL LADDER OR STAIR REQUIRED NET CLEAR DIMENSIONS WHEN FULLY OPENED TO PROVIDE 9 SQUARE FEET OF OPENING LADDER EGRESS *At least 12" in width *Rungs not more than 18" on center *Minimum 3" toe space *Permanently fixed *Non-combustible *Shall extend to top of wall LADDER OR STAIR PERMITTED TO ENCROACH MAXIMUM OF 6 INCHES INTO REQUIRED DIMENSIONS 1• 1 EMERGENCY ESCAPE OR RESCUE OPENING WITH FINISHED SILL HEIGHT BELOW ADJACENT GRADE \\\ \\\'/// \\\"///\\\\ \\\ '///\\\'/// \\\"/// \\\\'/// 36" MIN 36' MIN 1 *Where bars, grills, covers, screens or similar devices are installed over emergency escape and rescue openings, they must be openable from the inside without the need of special knowledge or special tools, and the force to open them may not be greater than that required of the opening itself.