Loading...
1996, 06-06 Permit: 96004153 SewerSPOKANE COUNTY DIVISION OF BUILDING AND PLANNING 1026 W. BROADWAY • SPOKANE, WA 99260-0050 (509) 456-3675 SITE ADDRESS: PARCEL NUMBER: SUBDIVISION: LOT INSPECTOR: WATER DIST: OWNER: PHONE: ADDRESS: SITE INFORMATION 1911 S CALVIN RD SPOKANE WA 99037 45262.3203 UNKNOWN BLOCK: FRANK PALADICHUK RICHARDS, MICHAEL B 509 928 7636 1911 S CALVIN RD SPOKANE WA 99037 CONTRACTOR TLC CONSTRUCTION LICENSE #: TLCCO**107M6 SEWER CONNECTION PROCESSING FEE TOTAL PERMIT FEE PAYMENT DATE 1 10.00 $50.00 ZONE: UNK PAYMENT SUMMARY -warm WYNEWVONT 06/06/96 00005017 $50.00 TOTAL FEES $50.00 ISSUED PERMIT AMOUNT PAID AMOUNT OWING $50.00 BY: CAROL FRAZIER $.00 PROJECT INFORMATION PROJECT NUMBER: 96004153 ISSUE DATE: 06/06/96 PERMIT USE: SEWER CONNECTION - EARLY DAWN (96S-564) APPLICANT: TLC CONSTRUCTION PHONE: 509 927 6760 ADDRESS: 13816 E 12TH SPOKANE WA 99216 CONTACT: GENEVA PHONE: 509 927 6760 SETBACKS -> FRONT: NA LEFT: NA RIGHT: NA REAR: NA LENDER NAME: PHONE: ADDRESS: PERMI,T(S) 1 NOTES .***FOR SEWER STUB AS-BUTLT TRFORMATTOPT AIRY IITSPECTTOAS, CAtt." THE COUNTY UTILITIES DEPARTMENT AT 456-3604*** CONTRACTOR OR APPLICANT IS TO FIELD LOCATE AND CONFIRM THE ELEVATION AND POSITION OF SEWER STUB PRIOR TO ANY OTHER EXCAVATION TO LOCATE BURIED CABLES, GAS PIPING, WATER LINES, ECT. CALL BEFORE YOU DIG (456-8000) SEWER STUBS ARE TO BE CHECKED PRIOR TO CONNECTION TO INSURE THAT THEY ARE CLEAR AND UNOBSTRUCTED TO THE SEWER MAIN ********* CALL FOR INSPECTION PRIOR TO COVER ********** 24 HOUR NOTICE REQUIRED ********** 456-3604 ********** NOTICE It is the responsibIity of the permittee, not Spokane County, to see to it that the use described on the front of this permit complies with applicable codes and requirements and that required inspections are requested. Failure to request required inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may necessitate remova of certain parts of the construction at the owner's/permittee's expense. At a minimum, the tollowirig inspections ARE REQUIRED by County Code: 1. FOOTING - when forms and reinforcement are in place and prior to placement of concrete. NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zonirlg regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from the property line or the center line of the roadway hght'of'wsy, whichever provides the greater setback from the center line of the roadway right-of-way. Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback provisions lies solely with the permittee —neither Spokane County nor its authorized representatives assume any responsibility for the verification or location of your property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require its relocation at the owner's/permittee's expense. 2. FOUNDATION when forms and reinlorcement are in place and prior to placement o/concrete. (Blocking for a manufactured home is required to be inspected prior 10 the instaIation of skirting,) 3. FRAMING ' after all framing, bracing and b!ockirig is in place, and pxo uurunoea|ing. 4. INSULATION - prior to the ir,staflatron of drywafl. 5. PLUMBING after mugh-in, before covering, and final. 6. MECHANICAL - rough -in of piping, before covering, metal chimneys before concealment, and final. 7. FINAL - when complete and prior to occupancy and/or use. Please provide 24 hours notice. NOTE: In addition to inspection of the otructue, this inspection includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access on-site drainage (^2nuswm|es'). road improvements, parking, and landscaping are common requirements of a permit/site plan which must be completed prior (0 final approval of a building or issuance of a Certificate of Occupancy. In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywmU, cnncmte, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with commercial projects. CALL 456-3675 FOR INSPECTIONS. TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE. YOUR INSPECTOR IS UNDER CERTAIN CIPARTS OF ¥OUR PROJECT MAY REQUJRE INSPECTIONS FROM OTHER AGENCIES: • Road cuts for utitities or drives, County Engineer's Office • Sewer connection, County Utilities Department 4563600 456'3604 or State Department of Transportation or City Public Works Department 456-3000 625-6300 • On-site waste disposal system, Spokane County Health District • Electrical wiring, State Department of Labor and Industries 324-1560 • Construction in aVood plam. County Engineer's Office 456-3600 324-2640 EXPIRATION Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit if not commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration. At a minimum an inspection should be requested at Ieast once every 180 days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the original fee, subject to certain limitations— please call us if you have any questions. MISTAKES? If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous information in the permit, please bring it to our attention immediately by filing a written request for correction within 10 working days of discovery. All such requests should be directed to the Division of Building and Planning at the address found on the face of this permit. | certify that | have examned this penn|Vapp|icaion, state that the information contained in it and submitted by me or my agent 10 compile said permit/application is true and correct, and authorize Spokane County to proceed with processing. In addition, | have read and understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. | understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancet the provisions of any state or locat law regulating constmcxion, or as a warranty of conformance with the provisions of any state or local laws regulating construction. SIGNATURE OF OWNER OR AGENTDATE APPLICATION