Loading...
1992, 03-17 Energy Code Compliance0 4 WA•'! Y SUN ;J. c. 1991 WA 'S ATtr: ENERGY. CO E: COMPLIANCE: REPORT 03/17/92 FILE: CM \WATTSUNJ\DURHEIMi. WS HOUSE ID: Dl.1RHE1M :lite. Homeowner: BRIAN DURHEItai Builder: (509)466-4676 ( ) The PROPOSED design *COMPLIES* COMPONENT PERFORMANCE. ENERGY BUDGET REFERENCE DESIGN C':' m C'.' ren t BCS Wall :;.'ti' BG Slab 3.5' BG Wall 7' BG Slab 7' On Grade Slab Glazing @15% Doors AG Wail Ceiling, Vault Infiltration PROPOSED DESIGN COMPONENTS Component BG Wall SG Sire, BG Wall Description Anal'v ,t : TOM BAGGOT jurisdiction: SPOKANE COUNTY BUILDING Utility: :INLAND POWER AND LIGHT House Tyne: Single Family/Duplex Floor Area a 2328 t't 2 Weather Data: Spokane, WA Climate Zone: _ with 1991 WA State Enerciv REFERENCE 326 4.37 Code. PROPOSED 326 Btu/m--E= 4.82 kWh/ft-yr Reference Value X Area = UA U -0. 04i F-0.640 U-0.036 F-0.554 U-0. 400 U-0.200 U-0. 044 U-0. 034 ACH-0. 350 56 16f•t 586 64ft t= LF f t 349.2 40.0 1111 1056 13269ft3 ( Reference UA Value X Area = 10. i 21. S: 46. :J 13. 0 139. •7 S. 0 4t). 9 35.9 60.3) .SGC, R19 Batt 3.5' depth U-0.041 F-0. 6F:5 R19 Batt 7' depth U-0.036 56 16ft 566 2.;:3 10.0 21.2 --------------------- i _1.r- 1teras in parentheses nc t incl tided in COMPONENT PERFORMANCE totals. ** Denotes non-standard values -• check calculation of thermal value. Wifl TSUN 5.2 1991 WA STATENERGY CODE COMPLIANCE REPORT 03/17/92 FILE: C:\WATTSUN5\DURHE1M.WS HOUSE. ID: DURHE1M B(; Slab On Grade Slab R15 4' vertical Glazing Doors no Wail (I19% **E:GL. 3/4" VINYL W/Af'13ON Metal R-5 base case **6" TONGUE AND GROOVE LOGS R-10 R19 STD Lao Wood R30 batt Vault vented cxld :16o+c -Standard Air Sealing Ceiling Infiltration Struc Mass Light Frame, Sheetr+M+ck walls Hr (-1T 1 NG / C:OOL_ I NG / VEN'T is i_A T I NG SYSTEMS Heating System Type: System Efficiency„ Modified Efficiency: Design ACTH; Heating i_c +ad (at 66F cit): System Size: Maximum Size @i50%e PROPOSED Electric: Zoned 100 % 100 0,60 .30596 9.0 13.4 Btu/hr kW kW Average Annual Heat: 145137 kWh Annual. Cost: 602 Ventilation System: Discrete Spot & Whole House Cooling Load(at 12F dt) c Recommended Size Id1:5/ Solar Access GLAZING ORIENTATION South: Southeast: East Northeast: PROPOSED 56.9 ft2 29.9 20.:.359 Btu/hr 2.4 tors Partially Shaded ..b 4 F-0.450 U-0.360 U-0, 190 U-0.100 U--0. 062 U-0.034 i34 ACH--0.350 North Northwest: West Southwest: 64ft 46.5 24 f t 10.6 206.0 74.2 40.0 7.6 1043 104. 211 13.1 10056 3:5.9 13269f t 3 ( 60.3) Proposed o -ped M- 3.000 2326 PROPOSED 42.1 ft2 I.J.5 ✓�6 6964 Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. June 9, 1992 Steve Schlang Real Log Homes P.O. Box 8509 Missoula, MT. 59807 Re: Durheim Residence - #5887 Nine Mile Falls, WA. Steve: As requested, I have complete a general review of your drawings on the above noted residence (stamped Final Set - dated 1/27/92) for conformance to the design criteria for Nine Mile Falls, Spokane County, Washington. I have reviewed the upper structure portion of the residence only and have not considered the foundation. My review finds the design to be structurally adequate. For details, connections, nailing, etc. not shown on the drawings, the contractor shall use information set forth in the Uniform Building Code Section 25. This initial review has been very general in nature, so please call with any questions. BEAUDETTE CONSULTING ENGINEERS, INC. 211 NORTH HIGGINS MISSOULA, MONTANA 59802 TEL: (406)721-7315 FAX: (406)542-8955 Sincerely, BEAUDETTE CONSULTING ENGINEERS INC. Tom R. Beaudette,‘'N -"4:714-z- •