Loading...
1992, 05-29 Super Good Cents ReportWATTSUN 5.2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT FILE: C:\WATTSUN5\RS#301.WS 05/29/92 HOUSE ID: RS#301 Site: 14515 EAST 5TH VERDALE, WA 99037 ( ) - Homeowner: RON SCHMIDT Builder: ( )533-7178 ( )994-4466 Analyst Jurisdiction Utility House Type Floor Area : MICHAEL DeVLEMING : SPOKANE COUNTY : VERA WATER & POWER : Single Family : 5652 ft2 Weather Data: Spokane, WA Climate Zone: 2 The PROPOSED design QUALIFIES for SGC(91 MCS) Tier 1. COMPONENT PERFORMANCE ENERGY BUDGET REFERENCE 795 4.28 PROPOSED 773 Btu/hr-F 4.69 kWh/ft2-yr REFERENCE DESIGN Component Description Reference Value X Area = UA BG Wall 7' BG Slab 7' Floor Glazing @15% Doors AG Wall Ceiling, Attic Ceiling, Vault Infiltration R21 batt 7' w/TB R30 vented joist 0.35 U -value Metal R5 base case R21+R5 ADV R49 blown Attic ADV R38 batt vault vented Standard air sealing U-0.034 F-0.557 U-0.029 U-0.350 U-0.190 U-0.041 U-0.020 U-0.027 ACH-0.350 2016 288ft 50 847.8 56.0 1401 2690 240 23000ft3 68.5 160.4 1.4 296.7 10.6 57.4 53.8 6.5 139.3 Reference UA 795 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall R21 Batt 7' depth BG Slab Floor R30 vented Joist 16oc U-0.034 F-0.557 U-0.029 2016 68.5 288ft 160.4 50 1.4 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. * Denotes adjusted UA to reflect 7-1/2 mph wind speed. Page 1 WATTSUN 5.2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT 05/29/92 FILE: C:\WATTSUN5\RS#301.WS HOUSE ID: RS/301 Glazing @8% 2G1 Wood 1/2" w/low-E U-0.410 **2 -GLAZE, VINYL FRENCH DOOR U-0.380 Doors Wood 1-3/4" solid flush U-0.330 Metal R-5 base case U-0.190 AG Wall R21 INT Lap Wood U-0.054 Skylights @ 2G1 Wood 1/2" w/low-E U-0.520 Ceiling R38 blown Attic STD baffled U-0.031 R38 blown Scissor 4:12 STD baffled U-0.040 R30 batt Vault vented 2x12 24oc U-0.033 Infiltration Standard Air Sealing ACH-0.350 Struc Mass 433.5 40.0 20.0 36.0 1775 17.0 1473 1200 240 23000ft3 169.1* 14.8* 6.4* 6.8* 95.9 8.5* 45.7 48.0 7.9 139.3 Proposed UA 773 Light Frame, Sheetrock walls M- 3.000 2851 8553 Slab w/carpet w/pad, Sheetrock wall M- 5.000 2801 14005 HEATING/COOLING/VENTILATING SYSTEMS Heating System Type: Make: System Efficiency: Modified Efficiency: Design ACH: Heating Load(at 66F dt): System Size: Maximum Size @150%: Auxiliary: HP Balance Point: Average Annual Heat: Annual Cost: Ventilation System: Cooling Load(at 12F dt): Recommended Size @125%: Solar Access: PROPOSED Heat Pump: Air Source HP Air Source Default 6.8 HSPF 178 % 0.60 59140 Btu/hr 47.4 kBtu/hr at 27.1 kBtu/hr at 26.0 kW 12.0 kW 27 F 18296 kWh $ 695 Integrated w/Forced Air Furnace 29064 Btu/hr 3.4 tons Partially Shaded 47F 17F PROPOSED DUCT SYSTEM SUPPLY RETURN Location Avg Rvalue Surface Area All in heated space All in heated space = =-- == _ = = -= = = R- 8.0 R- 8.0 Page 2 1130.4 ft2 226.1 ft2 WATTSUN 5.2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT 05/29/92 FILE: C:\WATTSUN5\RS#301.WS HOUSE ID: RS#301 GLAZING ORIENTATION South: Southeast: East: Northeast: PROPOSED 172.0 ft2 33.0 North: Northwest: West: Southwest: PROPOSED 256.5 ft2 12.0 Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. ------ __—__________—____==----- Page 3 WATER AND POWER NORTH 601 EVERGREEN RD. P O. BOX 630 VERADALE, WASHINGTON 99037-0630 May 29, 1992 Marty Robinson Department of Buildings :th--Jee-. Spokane, WA 99260-0180 Dear Marty: Distributors of Water & Power Telephone 924-3800 w42- C64 t)-0 RA IVt,� � HeFl� T//& ��2-ZrrSz The dwelling structures at 14515 East 5th. listed on the attached information packet has been reviewed by the undersigned and meets the Super Good Cents qualification criteria for the Component Performance approach using the WATTSUN5.2 computer program. In order to meet the Energy Budget requirements, a heat pump with a minimum of 6.8 H.S.P.F. rating will be required, and the Ventilation System Specifications must be complied with. I have sent a copy of this report to Ted Miller and Ron Schmidt (owner) and informed them that they need to bring you copies of the plans A.S.A.P. Sincerely, VERA WATER & POWER cciA Michael DeVleming, Directo Energy Management Services Enclosure N0911-1 601 EVI;RG9FCN RD. 0 0 BOX 630 VIPADA41±, WASH/N{1;10N 99037- 0630 May 29, 1992 Ron Schmidt P.O. BOX 727 Veradale, WA 99037 Dear Ron: Distributors of Water & Power lelephone 924-3800 Here is the wattsun run for the 14515 East 5th. I have sent a copy of the report and a note informing Marty Robinson (Spokane County Department of Buildings) that you (or Ted) will be bringing him a copy of the plan for this home. Give me a call in you have any other questions. Sincerely, VERA WATER & POWER Michael DeVleming, Director Energy Management Services Enclosure