2006, 03-13 Permit App: 06000808 Finish BasementProject Number: 06000808 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 3/13/2006 Project Information: Page 1 of 2 bt tt-6 I Pemiit Use: finish basement, add bedroom & rec room Contact: ODEA, MICHAEL J & KENDRA J Address: 13411 E DESMET AVE C - S - Z: SPOKANE VALLEY, WA 99216 Setbacks: Front Left: Right: Rear: Phone: (509) 922-4571 Group Name: Site Information: Project Name: Plat Key: 000000 Name: Range District: Sout Parcel Number: 45151.0302 Block: Lot: SiteAddress: 13411 E DESMET AVE Owner: Name: ODEA, MICHAEL J & KENDRA J Address: 13411 E DESMET AVE SPOKANE VALLEY, WA 99216 Location:: CSV Zoning: UR -3.5 Water District: Area: 1,125.00 Acres Urban Residential 3.5 Hold: ❑ Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Building Plan Review ReleasedBy:- T Septic Sys Review -Nwt4311310t. ReleasedBy: C e Ct.f - irtr . P.CO-tiriev J 3.It'1Itxo t ctn4aci-ed p-rgo a (L�ond t\ t • -. • %0.r ouo-S) ... • [Q ► rrn3r. vanuanCa -3t�-t phovt+i3 +o H:II4 - \ Permits • Contractor: OWNER Operator: AMB Printed By: AMB Bu'ilding Permit Firm: OWNER Phone: (000) 000-0000 Print Date: 3/13/2006 Project Number: 06000808 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 3/13/2006 Page 2 of 2 Notes: No Home Profession Needed for Kendra O'Day Payment Summary: Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 3/13/2006 03/14/2006 11:01 509324/567 I1 13 2005 16:53 FR 1 Project Ntunbel: 06000805 Inv: .1 Application TIIJS IS NOT A PI,IthIIT cit:llties will he :1S$eSt^(l for commet►t.tng wort; willttott1 :I 110rtttil j'r0"r_i1t r►tLn'rn.7l1Ai1: I , di Coulact: 0I)I A, AtiCll:i.1,L & !:� t�r:rr:� ., Penult Use: fu ool► bt,senntadd ballroom ii:rcc roots Addr._ss: 13.111 E DE$N11.:1• AV -1; C - S - x: SPOKANE VALI-EV, PYA 992_16 Phone: (509) 922- t5;11 Setbacks: �' oru La: Right:Rear. Group Nara:.: Project Naim: SRHD EHS TO 324156? Date: 3x1312006 PAGE 01/01 P. 01/02 !'age 1 int .11f� In tL2•1 LI LWi Plat 1G:}: 000000 Name: flange Patc'.I Number: 45151.0302 r)hck: Sit©Address: 13411 E PESM.ET AVE District: Sutti Lot: Owner: Name: ODEA, ti1ICI:14L J .k KENDRA •1 Address: 13:111 E DER/114 AV .31'0)ti.Ar`rt: �'.t.L1�l:)', \VA )'x716 Location:: CSV r tirir.,n IC+rsiltcnttaI33 r'1 �OninQ: U1Z-3..i 1 Tol•:1: �t cr D1�micr - i 1vt�lU Cly' �� (11): 0 ATMATMt,11,125.00Acresrta Width: 0 D'-1'Ili Nbr of Ditto: 0 Nbr of DweUln. : 0 _ Rfwierti�.I�r(,lI•,rr litlr�_ a.=:...-•yam—�'__—__----- dull; Platt 1:evielt' St rtic Sys Review 2r9- Con tra c :Or: OWNER • `' .�'�"R r y t1*Zpvlire" ?��•. rt7 fi, Tf-1��t�• �..a 11treldiny ?emir Operator: A1+4.01 Printed Dy: AT�^t1T MIR 14 2006 11:17 Furs: O'W'N. 11 phot! : (000) 000-0006 Print Date: 3/13/2006 509324156? PRGE.O1 Permit Center Spakane .0000 Valley Spokane Valley, WA 9920 (509)688-0036 FAX: (509) Community Development www.sookarevallev.ora.con1 11707 E Sprague Ave, Suite 106 Residential Construction Permit Application PERMIT NUMBER: Q Rai \ PERMIT FEE: MAR 13 2006 New Constructo Accessory Bldg ►n�n�R�mori o Deck o Other: SITE ADDRESS . 3411 Dc-e,rr_/-f- ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building owner . . Name• 011 Kr- 0 7)p44 MAIN FLOOR TO SQ. FTG: / 0 O D Address: 1 3 4 I I E D4's'm t 1 IMPERVIOUS SURFACE AREA: City: f d kRY1 / Zip: gcrjj Phone: 922 «j/ Fax: Fax: Contact Person:: Name' Mlkr n fXQn Phone: :Contractor :..;.. , DIMENSIONS: 6S-# Name: DW %Lgr MAIN FLOOR TO SQ. FTG: / 0 O D Address: UNFIN BASEMENT SQ. FTG: /000 IMPERVIOUS SURFACE AREA: City: GARAGE SQ. FTG: ti 00 Zip: Phone: # OF BEDROOMS: 3 Fax: Lic No: SEWER OR SEPTIC? 5 Prio Exp. Date: City Business Lic No: Describe the scope of work in detail: Cost of Project: i-''" /, 000 c0is/ruc4a T thkno✓ h4 ,77d/* 1vAI/% ID (0421---4 -441s- h/1 h -ed covi, t (et . t/G on,, **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK / DIMENSIONS: 6S-# OF STORIES: TOTAL HABITABLE SPACE: /00 0 MAIN FLOOR TO SQ. FTG: / 0 O D 21°" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: /000 IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: ti 00 DECK/COV. PATIO SQ. FTG: o 30% SLOPES ON PROPERTY: 0 # OF BEDROOMS: 3 CONSTRUCTION TYPE: HEAT SOURCE,: f-i.�itaAlf &,95 SEWER OR SEPTIC? 5 Prio The permitee verifies, acknowledges and agrees by their signature that 1) If this perrnit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a perrnit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application n be, processed. Signature t. , 0//0 Date 1/43/DA Method of Payment: (Faxed permit applications will only be accepted with major bankcard) 0 Cash ❑ Check 0 Mastercard 0 VISA Bankcard #: Expires: - VIN#: Authorized Signature: REVISED 8/25/2005 ❑ Other Si o1 ane galley, 11707 E Sprague Ave Suite 106 ♦ Spokane Valley WA 99206 509.921.1000 ♦ Fax: 509.921.1008 ♦ cityhall@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. O Two sets of plans including Site Pian, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor. Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. 17/ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. Smoke detector locations ❑ 22" X 30" attic access location D 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage o Floor framing details: Joist type, size, spacing and installation details o Roof framing plan and details O Fumace and hot water heater location. ❑ All header locations: type, size, and connections o Foundation plan ❑ Insulation information NUJ A 11,- 3140 0*.4 WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°,1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Option Glazing Area10: of floor Glazing U -Factor Doors U- Factor Ceiling2 Vaulted C eiling Wa1112 Above Grade Wall? int' Below Grade Wall? e' Below Grade Floors Slabs on Grade Vertical Overhead „ I, 10% 0.40 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 II. . N' 15% Me 0.40 0.58 0.20 R-38 R-30 R-19+ R-5° R-21 R-12 R-30 R-10 ' -�HI Ir NO 0 � OF TAyIt7.)a, �� ' - - 0.58 0.20 R-38 R-30 R-19+ R-5" R-21 R-12 R-30 R-10 N. . ' , iAi 1570 Group R-1 Occupancy Only 0.35 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-301 U=0.029 R-10 / F=0.54 V. ' ,. Unlimited Group R-3 . Occupancy Only.-:, 0.35 .... 0.58 • y .13P1. 0.20 R-38 R -3D R-21 R-21 R-12 R-30 R-10 int' VI.; ..„.0.°4 "' 0..; R -P'. Occupancy Only , AGroup J 0.58 0.20 R-38 / U=0.031 R -3D / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-1 D / F=0.54 * Reference Case 0. Nominal-yajues are forvyogd frame assemblies only or assemblies built in accordance with Section 601.1. •I • ! 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher):, Proposed designs which cannot meet the specific requirements of a listed option above may aalculatb bompliancetf' Chapters 4 or 5 of this Code. 2. Requirement applies to all ceiliigs`except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. WSEC Builder's Field Guide 5th Edition COOPERATIVE EATENSION WASHINGTON STATE UNIVERSITY ENERGY PROGRAM 1-7 STAIRWAYS: Minimum width 36 in. with min. tread run of 10 in., max. rise of 7 3/4 in. & nosing of 'A in. Min. 6 ft. 8 in. headroom. Enclosed usable space under stairways requires 1 hour fire protection of in. GWB HANDRAILS: Height of 34 — 38 inches when required by four or more risers shall be continuous the full length of stairs with the ends retumed or rounded. LANDINGS: Required min. width of 36 in. or width of stairway and 36 in. travel distance FACTORY -BUILT FIREPLACES: Combustion Air Required Hearth Clearances per Manufacturer's Instructions Tight Fitting Doors Required UPC 508.2 — Water heaters require anchonng or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. WINDOW WELL: Min. 9 sq. ft. horizontal area. Min. 3 ft. horizontal projection and width. Max. 44 in. vertical depth without a ladder EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING ROOMS 1) NET R OPENING 5 i SQUARE FEET GRADE Fl DOR OPENING (MAX 44-) 5 0 SQUARE FEET 2) NEI CLEAR llPEN;NG HEIGHT 2-1 INCHES 3) NET CLEAR OPENING WItJTH 20 INCHES 4) MAX FINISHED SILL HEIGHT 44' ABOVE 1,L00R BI EMERGENCY ESCAPE & RESCUE OPENING SHALL BE 0?E RATIONAL F ROM THE INSIDE OF THE ROOM WITHOUT THF IISF HE KEYS OR TOOLS Egress windows openable 5.7 sq. ft. - 44" sill SMOKE ALARMS SHALL SE INTERCON- NECTED AND HARD WIRED IN SUCH -A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS. AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24' & ON EACH FLOOR) WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. EXHAUST FANS 100 CFM kitchen 50 CFM bathrooms & laundry yaw l roo ra ts-xTe a Blocking required at mid height in unfinished bearing walls PIZEvicIAS WO/20 LCDV W"_ s 5�� N oi'v'S o f T. t b 4E- f r N ✓ ▪ W r (1610 I nw-a-I012, CU-ticnov, 3 fru R r REG R.oOyv- `( O") `{r1 %r) 11'i " 6X1Snoti tediu. �►,�a � C r � z 4 t 2 ' J —113" 5ry0gG O DC.T cT NEVI tonsreucnaN 1 0 Z Stook€ • Kiwi r r iVl ati c w4FTs 4 O r r [11 4410 MAT 040 w e-IMLLL Bibug ec,v--SS Ir6,{2-e5S wt•noe\,) wrnoovi - Cr PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS erso0Ifilley REVIEWED FOR CODE COMPLIANCE SPOKANE VALLEY EiUILDIN DIVISION