Loading...
2015, 02-06 Permit App: BLD-2015-0226 Shop4,o0Valley- Community Development Department Permit Center 11703 East Sprague Avenue, Suite B-3 Spokane Valley, WA 99206 Tel: (509) 688-0036 Fax: (509) 688-0037 permitcenter@spokanevalley.orq (Staff Use Only) PERMIT NUMBER: PERMIT FEE: RESIDENTIAL CONSTRUCTION PERMIT APPLICATION f IVG VII 6%•••1111•J. AV\. 1 WI% `I Pt E1 DECK 1 .1.%•.1.%•III r rl..rrv✓k.I .�{ WWA 1.11,101.11,104�o 9 OTHER ab SITE ADDRESS: 157? c Z Project # PL,D-aol's-o Upper Floor 5Q FT: 2q ASSESSORS PARCEL NO.: LEGAL DESCRIPTION: RECEIVED BUILDING OWNER NAME: FEB 0 6 2015 e--, -----' r NAME: i rr Al or r 2! --— - ADDRESS: iiciQ E��,f.L = ,_ '/ �f CITY: i5/%QKidrf/F �AY SUb # n��y'I V. # j 7L' STATE: 6j04 / /[30�% PHONE: 2)9 ) 929'-94,UC) FAX: CONTACT NAME: / /lin -r Al%p& Ag PHONE: CELL: Csiez44 r FAX: CELL: CONTRACTOR NAME: Z2E la/E!? MAILING ADDRESS: Luwf R/r (fortyl,n r, (ago .1- A,4'(/,0,✓O 4o CIN: ,,,,-)41A,06 - STATE: kit PHONE: 907.9 / ?0-0 - FAX: CELL: CONTRACTOR LICENSE NO.:2jf //n)&J6 EXPIRES: CITY BUSINESS LICENSE 140.: DESCRIBE THE SCOPE OF ORK IN DETAIL AND INDICATE USE & PROPOSED USE: 30 tso p 46t ZIP: .?,9 / P ****YOU MUST COMPLETE THE FOLLOWING**** MARK N/A IF NOT APPLICABLE Height to Peak: Dimensions: 3o )(S v No. of Stories: / Total Habitable Space: Maln,Floor SQ FT: 4.970 Upper Floor 5Q FT: Unfinished Basement SQ FT: Finished Basement SQ FT: Garage SQ FT: Deck/Covered Patio SQ FT: Impervious Surface Area: 30% Slopes on Property: No. of Bedrooms: Construction Type: Heat Source: Sewer or Septic: TOTAL COST OF PROJECT: $ 016/ OOD DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner In this transaction. 4) All construction is to be done In full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Pians or additional Information may be required to be submitted and subsequently approved before this application can be processed. Signature / `yj /may-irL Date/4 /Re-- Updated /S/ Updated 1-11-11 Page 1 of 1 http://www.spokanevalley.org/filestorage/124/938/210/948/1496/Building_Permit_ _Residential_11-11-11.doc WAMBEKE ENGINEERING Daniel Wambeke, P. E. 2913 East 615' Court Spokane, WA 99223 Telephone: 509-443-6186 • Fax: 509-448-6582 January 31, 2015 Mr. Randy Koeller ZIEGLER LUMBER COMPANY 620 E. Holland Spokane, WA 99218 • dwambeke @msn.com Project # &n-.iats RECEIVED op FEB 0 6 2015 CSV PERMIT CENTER SUBJECT: 30' X 50' X 14'6" POST FRAME BUILDING FOR TONtDtp9ftH I ,,115191 SPOKANE VALLEY, WA 99206 Dear Randy: NUE, This post frame building was sold to Mr: Taggart for construction on his lot in Spokane Valley using the standard post frame building plans I have prepared for Ziegler Lumber Company. The requirements for this building are 40 PSF roof live load, 110 MPH wind speed, Exposure B, Seismic Design Category C, IBC 2012 and 2,000 PSF allowable soil bearing pressure. The building has 10' post spacing and 4:12 pitch roof trusses. I have reviewed the design of this building and checked it for the diaphragm design criteria used in the standard plan design. The front endwall has a 16' x 12' overhead door and a 3' pass door. There is sufficient steel sheeting on this endwall to transfer lateral loads on the sidewall and roof to the base of the building. However, it will be necessary to install #12 x 5/8" stitch screws @ 9" o. c. to all steel siding vertical side laps —this endwall only. The rear endwall has no openings. There is sufficient steel sheeting on this endwall to transfer lateral loads on the sidewall and roof to the base of the building. The left sidewall has no openings. The right sidewall has no openings. Sidewall openings have no effect on the lateral load resistance for this building. You may use the standard 40 PSF live load post frame building plans for all framing details and member sizes for this building with the above exception. Please contact me if you have any additional questions about the design of this post frame building. c'ere.ly, W""�1 k/C Daniel Wambeke; P.E. Enclosures DW:dw REVIEWED FOR CODE COMPLIANCE S "• • • VALLEY BUILDING DMS •,. 'l 0. 0 .A iria FILE Designer of Small Structures, Post Frame Buildings, Foundations, Light Gauge Steel Framing and Grain Storage Systems 1 10'-0" 10 -0" 10'-0" L_ J L 6x6x24 6x6x24 10'0" 10'-0" + 10'-0" 10'-0" 10'-0" U UU U 6x8x22 6x8x22 6x8x22 6x8x22 6x6x22 Tim Taggart 11519 E. Boone Spokane Valley, Wa. 99206 6x6x22 6x8x22 6x8x22 6x8x22 6x8x22 n n n n f 6x6x22 ❑ 6x6x22 6'-10 2 16'-3" 4x6x20 .� j 6'-101 \ I 3'-2" 2 6x6x22 y 4, � J 10'-0" 10' 0" 10'-0" 10'-0" 10'-0" /gr\ 17'-11" 17'-1 11 15'-6" 14'-6" 16'-6" 1 17'-6" 6'-6" 7'-6" 7'-6" 6'-6" 17'-6" THIS ENDWALL ONLY!! INSTALL #12 X 5/8" STITCH SCREWS AT 9" O. C. ON ALL STEEL SIDING VERTICAL SIDELAPS. 16'-6" 15'-6" /i .•1 0 **I 19! ".• • f • • sir 1 ' t • }.• ... •• V j • Nay 4 Project # Et-lam'.Doi5- Oa& RECEIVED FEB 0 6 2015 Aca- % PERMIT CENTER 4.01 PLANNING DEPT. APP IC/ q BY: DATE: -2-1/3/20t t • REV.