2008, 08-26 Permit App: 08003193 Addition, RemodelProject Number: 08003193 Inv: I Application Date: 8/26/2008 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Proiect Information:
Permit Use: ADD LOFT TO GARAGE / REMODEL BASEMENT Contact: FAZES, BRENT
BEDROOM Address: 4314 S DARCY DR
C - S - Z: SPOKANE VALLEY WA 99206
Setbacks: Front Left: Right: Rear: Phone: (509) 924-3247
Group Name:
Site Information: Project Name
Plat Key: 000594 Name: DARCY EST District: Sout
Parcel Number: 45333.0803 Block: Lot:
SiteAddress: 4314 S DARCY DR Owner: Name: FALES, BRENT
Location:: CSV
Zoning: AGRI
Water District:
Area: .00 Acres Width: 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Address: 4314 S DARCY DR
SPOKANE VALLEY WA 99206
Hold: ❑
Depth: 0 Right Of Way (ft): 0
Review Information:....
�,,
Building Plan Review ReleasedBy s= I",x
Originally Released: 8/25/2008 By: tmelbourn
Permits:.
Building Permit
Contractor: OWNER Firm: OWNER
Phone: (000) 000-0000
This Application: Total Project:
Description Grp Type Notes Sn Ft Valuation Sa Ft Valuation
BASEMENT R R-3 VB BASEMENT 0 $2,000.00 0 $2,000.00
BEDROOM
REMODEL
GARAGE U-1 VB
Item Description
RESIDENTIAL PERMIT FEE
WSBCSURCHARGE
SF PLNS RVW < 7999 SQ FT
530 $10,070.00
Totals:
530 $12,070.00
Units
Unit Desc
1
SELECT
1
SELECT
1
SELECT
Permit Total Fees
530 $10,070.00
530 $12,070.00
Fee Amount
$223.25
$4.50
$89.30
$317.05
Operator: JD Printed By: JD Print Date: 8/26/2008
Project Number: 08003193 Inv: 1 Application Date: 8/26/2008 Page 2 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Notes:
Payment Summary. �e �w _= ro .-1
Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $317.05 $317.05 $0.00 $317.05
$317.05 $317.05 $0.00 $317.05
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: JD Printed By: JD Print Date: 8/26/2008
Spolkane
,,;0oPValley
CITY OF SPOKANE VALLEY
Community Development Department
Permit Center
11703 East -Sprague Avenue, Suite B-3
Spokane Valley, WA 99206
Tel: (509) 688-0036
Fax: (509) 688-0037
Perm itcenter@spokanevaIley.org
(Staff Use Only)
PERMIT NUMBER'
PERMIT FEE: - - -- - - -" - --- -
RECEIVED BY
CITY OF SPOKANE VALLEY
QG 15 2000
PERMIT LATER
BY:
RESIDENTIAL CONSTRUCTION PERMIT APPLICATION
❑'! NEW CONSTRUCTION Zi ADDITION/ REMODEL ❑j ACEESSORY BUILDING
F1 DECK ❑ OTHER
SITE ADDRESS: 4314 S. DARCY
ASSESSORS PARCEL NO.: LEGAL DESCRIPTION:
BUILDING OWNER NAME:BRENT FALES
NAME:BRENT FALES
ADDRESS:4314 S. DARCY DR.
t.
CITY:SPOKANE VALLEY STATE:WA ZIP:99206
PHONE: 509-924-3247 FAX:SAME CELL: 509-994-4069
CONTACT NAME:SAME
PHONE:SAME FAX:SAME CELL:SAME
CONTRACTOR NAME:N/A
MAILING ADDRESS:
CITY: STATE: ZIP:
PHONE: FAX: CELL:
CONTRACTORLICENSENO.: EXPIRES: CITY BUSINESS LICENSE NO.:
DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE:
REMOVE EXISTING FINISHED BASEMENT STORAGE AREA - REPLACE WITH LOFT IN GARGE.
;SPLIT EXISTING BEDROOM / STORAGE AREA INTO TWO BEDROOMS.
- SEE ATTACHED DRAWINGS
PROPOSED USE:
PERSONAL RESIDENCE
Effective October 28, 2007 Page 1 of 2
C:\Documents and Settings\Brent\My Documents\Residential Construction Permit App Bedroom and Garage.doc
r- 3153
****YOU MUST COMPLETE THE FOLLOWING****
- MARK iN M IF NOT -APPLICABLE
Height to Peak:NO
Dimensions:No CHANGE
No. of Stories:No
Total Habitable
-CHANGE
CHANGE
Space: NO CHANGE
Main Floor SQ FT:No
Upper Floor SQ.FT Nq-
Unfinished Basement
finished Basement
CHANGE
eta ,_?a SM4 A 4Cr
SQ FT:N E
SQ F E
Garage SQ_ FT:No
Deck/Covered Patio
Impervious Surface
30% SI,Qpes on
CHANGE
SQ,-FT:No CHANGE
Area -NO CHANGE
-Property:NO CHANGE
. of Bedrooms:6,
Construction Type:No
Heat Source:NO
Sewer or Septic:NO
AFTER SPLIT OF ONE RO
CHANGE
CHANGE
CHANGE
Qtlk.a'a (trc-t•Jc_
TOTAL COST OF PROJECT: $ < $20000(- F'p' JF -'d f b"' 1b &4& WT
DISCLAIMER
The permitted verifies, acknowledges and agrees by.their signature that: 1) If this permit is for construction or on a dwelling, the dwelling Is/will
be served by potable water, 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property
owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of
Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of
Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional
information may be required to be submitted and subsequently approved before this application can be processed.
Signature r,�L3�t .. Date: & f�
Method of payment: ❑ Cash
6ankcard #:
Authorized Si4nature:
❑ Check ❑ Visa ❑ Mastercard
EXP: VIN#:
Effective October 28, 2007 Page 2 of 2
G:\Documents and Settings\Brent\My Documents�Residentiai Construction Permit App Bedroom and Garage.doc
:
ValiC p
11703 E Sprague'Ave Suite B 3 Spokane Valley WA 99206
509.688.0036 4 Fax 509:688.0037♦'permrtcenterC�spokanevalley.org'
As part: of our on=going commitment to. customer, service during the review 'process 'of your" project,
application, we are providing'you with a TARGET DATE for the initial technical application review.'. If Tor.,
any reason we cannot: meet this date' ;we will contact. you. with a revised: Target. date
Your application review TARGET DATE, is
PP �
The. -TARGET DATE is the date' we estimate your project application will have `had `its initial technical,
review. It is not the.date' for approval or permit issuance.
Tips for.a Smoother Project Application Review
➢
Submit complete, accurate,plans.arid documents.
Extra time may be req.uired.for resubinittals as.project application reviewers work on multiple, applications and it
may be several days before they can look at your new or:revised 'information.
➢ Designate a specific contact person to communicate with the City. =
While the person designated as,;the applicant's contactperson.with the City�can be, changed, "one individual with the. '
expertise for dealing.with reviewer comments would be the best choice for,ahe en
Call
process
➢ Call staff regarding the. status of your project only after the target date shown; at the top of the page
Although you should be contactedon, or by the target -date, please feel free: to contactus`: f youhaven't Beard from us
by your target date. Staff may contact you before the target date if the initial review as .'complete By; following this
procedure,`you will save time and allow the reviewers, tocomplete the work mor expeditiously
Steps in the Permit Process
1. Counter Complete. Your application has` been accepted. "as- "..counter 'complete..!: This.•.means` all of the required
documents, as indicated on your Pre -Application Checklist have_.been`submitted or- have -'been approved .for. deferred ,
submittal. This does not'prevent`technical staff from requesting additional. information as a result of:.their technical review., '
2. Quality Check. The next step in the process is a qualrfy,check,to make sure that the application is reviewab'le,and free
from substantive flaws that would prevent technical staff'from completing the,technieal review once it is ��started. 'When, ;
this step is complete, your 'application 'wiII be.. routed to the appropriaW staff `and reiriam im,their review queue until it
comes up for review.
3. Technical Compliance. Once an application is admimstrati vely.complete it is routed to techmcal'staff fo'r compliance
review. Depending on the type of project, technical .staff. may. ;include: multiple reviewers.�Nou should: be contacted by.
phone, fax; email, or mail by your TARGET DATE once the initial techn''ical• compliance review is complete.
4. Permit Issuance: When the technical compliance review of the application is complete, including• any subsequent re -
submittals, each reviewer will approve their section of the application and route it to the"Permit Center :When all sections
of the application are received, a Permit Specialist will Iprocess the application and contact -the person specified on your.''
application for permit pick-up.. Information regarding fees and pre -construction meetings (if required); will .be provided. by
the Permit Specialist at that time. ;
WHITE -APPLICANT PINK - BUILDING FILE REV 9/07
Site Address: 4314 S DARCY DR
Parcel Number: 45333.0803
Zoning: AGRI
Fire District: FD 01
Project
Transmittal
City of Spokane Vallee
Community Development
Department
11703 E. Sprague Ave, Suite B3
Spokane Valley, WA 99206
Phone: 509.688.0036
Water District:
Applicant: FALES, BRENT
4314 S DARCY DR
SPOKANE VALLEY WA 99206
(509) 924-3247
e-mail:
Contact: FALES, BRENT
4314 S DARCY DR
SPOKANE VALLEY WA 99206
(509) 924-3247
e-mail:
Contractor: OWNER
( ) - 0
Newproject E]
Previous pre -app meeting ❑
Plan revisions ❑
Transmittal Date:
Monday, August 25, 2008
Project Number. 08003193
Owner: FALES, BRENT
4314 S DARCY DR
SPOKANE VALLEY WA 99206
e-mail:
Occupant:
e-mail:
Arch / Engineer. R is C E � W E D
AUG 2 5 Z0
e-mail:
Project ADD LOFT TO GARAGE / REMODEL BASEMENT BEDROOM
Description:
Please send all plan review and project comments via e-mail to the
highlighted individuals.
Site Address: 4314 S DARCY DR
Parcel Number. 45333.0803
Project
Transmittal
City of Spokane Valley
Community Development
Department
11703 E. Sprague Ave, Suite B3
Spokane Valley, WA 99206
Phone: 509.688.0036
New project
Previous pre -app meevhig ❑
Plan revisions ❑
Transmittal Date:
Friday, August 15, 2008
Project Number. 08003193
Zoning: AGRI Water District:
Fire District: FD 01
Applicant: FALES, BRENT Owner. FALES, BRENT
4314 S DARCY DR 4314 S DARCY DR
SPOKANE VALLEY WA 99206 SPOKANE VALLEY WA 99206.
(509) 924-3247
e-mail: e-mail:
Contact: FALES, BRENT Occupant:
4314, S DARCY DR
SPOKANE VALLEY WA 99206 a=mail:
(509) 924-3247
e-mail:
Contractor: OWNER Arch / Engineer:
( ) - 0
e-mail:
RECEIVED BY
CITY OF SPOKANE VALLEY
QG 15 2000
PERMIT CENTER
I
I� 18 ter -
i
-�
II[�u
Project ADD LOFT TO GARAGE / REMODEL BASEMENT BEDROOM
Description: ) u I7i n ,M �(
J
Please send all plan review and project comments via e-mail to the
highlighted individuals.
MENas Aub, 21, 2008 11:00AM No. 9383 P. 1
Ma
MENEM
■®■
■®■
SprayCoolt
2218N, Molter Road
Liberty Lake, WA 99019 i
(509) 232 2600 •�\\
..........
SPR 00L"
Facsimile transmittal
To: �ovvi ( bou,Ty\ Fax: soq • q2/ --loos
From: j fi�,�-�- cele Date: 16 21- v 8
Re: 43i'4 S �c�rc�/ �,r. Pages: S. '�,cl- r✓ovcr
Upd�,�ecl M «.�to�s►y st�.bw+: ccs drtAC S bwVl
ori -fit, d'•sGu.sS'Ioh� W�tJe I�IA.� - �-�`�-s �
—to1 .
LGFr Zto� " Foo4lrrd, oddcd u`^�car ?oa-�s �h c�a,•r.�C
2
IMSC Go.,l t MR- W� YOtti✓ C D41 g„ �„eA'.L e
This fax may contain information that is privileged, confidential and subject to legal restrictions and penalties regarding its unauthorized disclosure or
other use, This transmission is for the intended recipient only, If you are not the intended recipient, please destroy this transmission (and any
attachments) without retaining a copy and advise the sender immediately' via e-mail, 'Unauthorized use or distribution is prohibited and may be unlawful.
Thank you for your cooperation.
WASHINGTON STATE ENERGY CODE
TABLE 6-2
PRESCRIPTIVE REQUIREMENT So" FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area
of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the
specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced
Framed Ceiling.
3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling
and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation.
Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of
ceiling area for any one dwelling unit.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12, or on the interior to the same level as
walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its
intended use, and installed according to the manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according
to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.
8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing.
9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C.
10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross
conditioned floor area shall be less than or equal to that value. Overhead glazing with U -factor of U=0.40 or less is not included in
glazing area limitations.
11. Overhead glazing shall have U -factors determined in accordance with NFRC 100 or as specified in Section 502.1.5.
12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement.
34 Effective July 1, 2007
Glazing
Glazin U-Factore
Wa1l'2
Wall.
Wall•
Slab'
'°:
Area:
Door
Ceilin 2
g
Vaulted
Above
int'
ext°
5
Floor
on
% of Floor
Vertical
„
Overhead
U -Factor
3
Ceiling
Grade
Below
Below
Grade
Grade
Grade
I.
12%
0.35
0.58
0.20
R-38
R-30
R-21
R-21
R-12
R-30
R-10
int'
lI.*
15%
0.35
0.58
0.20
R-38
R-30
R-19 +
R-21
R-12
R-30
R-10
R-58
III.
17%
0.32
0.58
0.20
R-38
R-30
R-19 +
R-21
R-12
R-30
R-10
R -5a
R'.
25%
0.35
0.58
0.20
R-38 /
R-30 /
R-21
R-15
R-12
R-30 /
R-10 i
U=0.031
U=0.034
int' /
U=0.029
F=0.54
Group R -I
U=0.054
and R-2
Occupancies
Only
�'.
Unlimited
0.35
0.58
0.20
R-38
R-30
R-19+
R-21
R-12
R-30
R-10
Group R-3
R-58
and R-4
Occupancies
Only
Unlimited
0.30
0.58
0.20
R49 or
R-38
R-21
R-21
R-12
R-30
R-10
Group R-3
R-38 Adv
int?
and R-4
Occupancies
Only
VII1.
Unlimited
0.32
0.58
0.20
R-38 /
R-30 /
R-21
R-15
R-12
R-30 /
R-10 /
Group R-1
U=0.031
U=0.034
int' /
U=0.029
F=0.54
and R-2
U=0.054
Occupancies
Only
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area
of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the
specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced
Framed Ceiling.
3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling
and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation.
Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of
ceiling area for any one dwelling unit.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12, or on the interior to the same level as
walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its
intended use, and installed according to the manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according
to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.
8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing.
9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C.
10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross
conditioned floor area shall be less than or equal to that value. Overhead glazing with U -factor of U=0.40 or less is not included in
glazing area limitations.
11. Overhead glazing shall have U -factors determined in accordance with NFRC 100 or as specified in Section 502.1.5.
12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement.
34 Effective July 1, 2007
24'
GARAGE LOFT ADDITION
zxg
„�f �NCs�^►�
eASTe" ali,
0
N
d7
L
c
M0 W04
� U_ m
me
C: -
aC)
M,
ew"
1
2
a
N
C.D
I
LO
Q
r
C
11
O
LL
_
o Cf]
d co
M
1
2
a
N
C.D
I
LO
' PROTECTION AND OPEWNGS BETWEEN
DVWcLUNG AND PRIVATE GARAGE SHALL HAVE:
1) MATERIALS APPROVED FOR ONE HOUR FIRE RESISTIVE
CONSTRUCTION ON THE GARAGE SIDE:
❑ SM TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) OR
❑ 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING)
2 OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE
E�LIMPED WITH SOLID WOOD DOOR, SOLID OR HONEYCOMB CORE
STEEL DOORS NOT LESS THAN 1 3/8', OR 20 MINUTE FIRE RATED
DOORS.
33H X 29W ACCESS DOOR
EXIST. DECK
Attic Ventilation
1 Sq Ft per every 300 Sq Ft of space
ventilated with at least 50% in the upper
Portion of roof area.
Attic Accessible
by 22'x 30"
-- DOUBLE 2 X 12 HEADER 2 X 8 JOIST (16" O.C.)
3'-10"
N r,� N+ JE>%—, 4 $ t_ rS S t oW-,& 5Tz WB" OSB FLOOR
oN
DROP DOVVN
ACCESS LADDER 6 X 16 X 20' BEAM
26"X26"X10" FOOTING
� 4X6X6?4"POST
10" J
GARAGE LOFT ADDITION (CROSS SECTION)
151-81
� r �
REMOVE EXISTING DOOR
I
BEDROOM
O C%j (326.0 SF)
W.0 "
I
I
REMOVE EXISTING WALL & DOOR
�---I-----------------------
SSI -5"
2V -1U 1/2"
EXISTING LAYOUT f DEMOLITION
O
N
m
3 ca cU N
� LL CY,
QQ
:7 mvcnW
0
4)
0
LU
oLU
gL
OC
00
FS
hoot
0
_a
T
coii
CA loo
�ci
EMERGENCY EGRESS REOUIREMENU
FROM SLEEP** ROOMS
ET CLEAR OPENING 5.1 SQUARE FM
GRADE fIOOR OPENING (MAX 44'I S 0 SQUARE FEET
21 NL T Cl FAR PlI'f NTNG HEIGHT 24 INCHES
31 NET rLf AR Oil NWG MOTH 20 INCHES
C 41AX I INI�14t O SILL HEIGHT 44• ABOVE FLOOR
! , t "t RGT 'jCv I SCAPE & RESOX OPENING SHALL BE
0;1^ ' AI %-% - ritW. THE INSIDE OF THE ROOM WITHOUT
THE S[ , •', S OR TOOLS
k
S
WHEN INTERIOR ALTERATIONS REPAIRS OR ADDITIONS SVQN
N D AND HARD WHi D IN SUCH A
SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING MANNER THAT THE ACTIVATION OF ON
DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED ALARM WILL ACTIVATE ALL ALARM
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW (BEDROOMS, AREAS APPROACHIN
DWELLINGS. BEDROOMS, VAULTED CEILIN
WITH RISE OF 24' & ON EACH FLOOR)
3Ox84
',48X84' E#=
I
I 5
I
BEDROOM
13'-3 1J2" I (161.5 SF)
I
I
2 x 4 WALL (16" O.C.),
ALL NON -LOAD BEARING
�---------- ---
12'-3 112"
NEW LAYOUT
s
30x84
Ii
S l� -
BEDROOM %
(144.5 SF) 12'-8 112"
1U-7 112'
EXIS71NG EGRESS
WINDOWS
IN -a,
7
_ s
G� r
(U o
0
Q
"rT tZ
om
�n
� Tti
41
W � � M
CV
u- aj c rn
m,0p
v >✓ M
m -q- 05
2
I
C
O
0
LL
m
ou
as
9Y
O �-
E
V�
d W
4
2
I
0
LL
m
ou
as
T
ZQ
Ji c
2
I
0! C7
rn
—I N1
g n a
0 0 C-0
rr' 0 M N x w
E<0 -- -
cr
<=
0
co
0 C)
C">
Q M
4aZNt't
M
00 c" ac
MM
.c S cr
0 0 M CC
2 cc x 0
F5 >
s tx;k M
N; cz 0
0 cu
4 6 rn
rr
cc Q -t
CA
C)
> <
cv, w
> M
MM<
fri�F-ryGrr
"'U00
.
< M
MWO-�L 1
M D rr < C)
0 3:0 2 V7
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR.
ROOF TRUSSES, BEAMS AND
FLOOR SYSTEMS PRIOR TO FRAMING
INSPECTIONS
CITY CPY
THIS BUILDING
E 'T
.7
TO FIELD INS E
Salley Sp -d -raw
;_l,0Wley
REVIEWED FOR CQ) E COMPLIANCE
SPOKANE VALLEY, ULDIN DIVISION
2- 0
7w p t�