1992, 04-02 Permit: 92-1646 Radon System Specs(i111111111 (011011111.011 E. 8620 44th Spokane, Va . 99206 Phone 509 926-6217 Fax 509 928-8689 Legend for Radon mitigation system — —perforated pipe beneath slab solid 9'ABS stack vent pipe RADON SYSTEM SPECIFICATIONS ATT RADON MITIGATION SYSTEM This radon mitigation system is designed only for the specific Job - site address designated. The system is not guaranteed unless installed by Cavalier Corporation Sub Slab System SO FT 1730 yes CravIspace System SO FT Jurisdiction County c 0 RV: Com,. Project Number Warren Environmental Protection - .11/1792 o ,Ii d e Dal. Ageri'r3y.•;R�rEiQ Builder Address Phone EHESE P 7T BY_�y ANS HAVE lice.N REVIEWED s 9T Vigue & Sons S 3806 Bovdish Spokane 99206 927 7433 Jobsite 1 81 6 S Favn Drive East of Mica Dishman Hvy # �jz - 1646 -63- a Radon Vent. garage basement 34 irtttier &gineering radon services E. 8620 44th i Spokane, WA 99206 Phone (509) 1111-6217 FAX (509) 928-8689 RADON SYSTEM SPECIFICAT * S, SPOKANE COUNTY: 1 1. Perforated pipe shalt be installed within the native soil or fill (sand, gravel or soil) at a minimum depth of 1" below the intended s$b. 2. The pipe shall be a Minimum diameter of 4". meet AASNTO M252, have perforatieas no wider than 1/16" and have a minimum of 2.5 square inches of total perforations per linear foot of pipe. 3. There shall be a minieum of 10 linear feet of perforated pipe per hundred squale feet of slab floor space. 4. The pipe shall be laid in a continuous loop, connected at both ends to the solid stack vent pipe. 5. Any slab area, which is larger than 10 square feet, which is isolated from othwr slab areas by footings or other barriers, shall have a perforated pipe installed to the above specifications. (The pipe can be a single length rather than a connected loop if the area is too small or narrow to accomodate a connected loop.) 6. A stack vent of ABS, schedule 40, minimum size 4", shall be connected to the sib -slab piping and proceed upwards to an exit location a, the roof, and extending 14" above the roof. The pipe stall be labeled "radon vent" every 16" or less for its tall length. The pipe's attic location shall allow a minimum of 4' of head room. When- ever possible this exit location shall be on the backside of the roof. 7. Any elbows in the steak vent piping shall have a centerline radius mim$um of 1.5 by pipe width. 8. An inline centrifugal fan, minimum 114 cfm @ 3/8" W.C., UL listed, manufactured specifically for radon mitigation, maximum sone level 2.2, shall be installed in the exhaust line, in the attic. 9. Couplings to connect the vent piping to the fan shall be elastomeric PVC, Fermco series 1056 or equal. 10. The fan shall be hard -wired and the breaker labeled "radon fan". 11. All penetrations and -joints in the concrete floor slab below grade shall be sealed with caulk or grout. 12. A notice shall be permanently attached to the electrical panel advising the outer or occupant about the radon system and that he/stD shall test the home for radon annually. The notice shall include Cavalier's name and phone number. 13. All craftsmanship shall be of high quality.