Loading...
2006, 06-22 Permit App: 06002418 Garage AdditionProject Number: 06002418 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 06/22/2006 Page 1 of 2 Project Information: .....:amuMMAr€ ,.. `V P i w 5,„vjggpx. nowA {TMC- ..-- Permit Use: 10 X 20 GARAGE ADDITION Contact: WHITE WATER CONSTRUCTION Address: 10403 S GRANITE DR C - S - Z: MEDICAL LAKE, WA 99022 Setbacks: Front Left: Right: Rear: Phone: (509) 299-4969 Group Name: Site Information: Project Name: Plat Key: 001648 Name: MISSION ADD igMSNEMMARMati District: Parcel Number: 45172.0519 SiteAddress: 1220 N FARR RD Location:: CSV Zoning: AGSUB Water District: Area: 10,450 Sq Ft Block: Lot: Owner: Name: THIEL, PATRICK H Address: 1220 N FARR RD SPOKANE VALLEY, WA 99206-40 Hold: ❑ Width: 76 Depth: 137 Right Of Way (ft): 50 Nbr of Bldgs: 2 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Released By: Driveway/Approach Originally Released: 06/21/2006 By: TSCHOLT Released By: Originally Released: 06/22/2006 By: amblake Landuse/Zoning/HE Conditions Released By: Sewer Review Originally Released: 06/21/2006 By: KKENDAL Released By: per utilities Operator: AMB Originally Released: 06/22/2006 By: amblake Printed By: jmm Print Date: 06/22/2006 Project Number: 06002418 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 06/22/2006 Permits: :. VV•,_W .,, Contractor: WHITE WATER CONST CO Address: 10403 GRANITE DR MEDICAL LAKE, WA 99022 Description Grp Type Notes POLE BDLG U-1 VB Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBC SURCHARGE Notes: Payment Summary: Permit Type Building Permit Building Permit Page 2 of 2 Firm: WHITE WATER CONST CO Phone: (509) 299-4969 This Application: Total Project: Sq Ft Valuation Sq Ft Valuation 400 $7,600.00 400 $7,600.00 Totals: 400 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT $7,600.00 400 $7,600.00 Fee Amount $153.25 $38.31 $4.50 Permit Total Fees: $196.06 Fee Amount Invoice Amount Amount Paid Amount Owing $196.06 $196.06 $196.06 $196.06 $0.00 $196.06 $0.00 $196.06 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: jmm Print Date: 06/22/2006 Project Number: 06002418 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 6/21/2006 Page 1 of 2 Project Information: Permit Use: 10 X 20 GARAGE ADDITION Setbacks: Front Left: Right: Rear: Site Information: gagmen Plat Key: 001648 Name: MISSION ADD Contact: WHITE WATER CONSTRUCTION Address: 10403 S GRANITE DR C - S - Z: MEDICAL LAKE, WA 99022 Phone: (509) 299-4969 Group Name: Project Name: District: F Parcel Number: 45172.0519 Block: SiteAddress: 1220 N FARR RD Location:: CSV Zoning: AGSUB Water District: Area: 10,450 Sq Ft Lot: Owner: Name: THIEL, PATRICK H Address: 1220 N FARR RD SPOKANE VALLEY, WA 99206-40 Hold: ❑ Width: 76 Depth: 137 Right Of Way (ft): 50 Nbr of Bldgs: 2 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Released By: Driveway/Approach Released By: Landuse/Zoning/HE Conditions Sewer Review Released By: Permits: ImpzeisvparAwampgrormgm, Operator: AMB Printed By: AMB Print Date: 6/21/2006 Permit Center SpoJane 11707 E Sprague Ave, Suite 106 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 Community Development www.spokanevalley.org.com Residential Construction Permit Application PERMIT NUMBER:a/4(k PERMIT FEE: C? , ❑ New Construction o Addition/Remodel o Other: o Accessory Bldg o Deck SITE ADDRESS / ? 'c N F;412.2 fa) . ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building owner DIMENSIONS: �O X?.O Name: PATi2rc4 TNr, Address: 104 n , i ,S. GRAi /Inc D Z . Address: /220 //, IaA,ez 2 City: ,s /'OK.4.V 1/.4CLCy Zip: Phone: Ci -1 C/ 7S8 Fax: Contact Person Name: jniA VNE 7 C y Phone: X 99-49( / Og3`7 Describe the scope of work in detail: l-sAr€4CaC / r7--()/1/ Contractor DIMENSIONS: �O X?.O Name: 1/1/ I-1 T77-- II,/ATG,e, OAA/ t i APL.) c DA�bC. Address: 104 n , i ,S. GRAi /Inc D Z . City: MEDLC.4L . -i is AIA Zip: 99.022 2ND FLOOR SQ. FTG: Phone: ,99- 4 9 6 9 Fax: Z.,:f - G,n i IMPERVIOUS SURFACE AREA: Lic No: Wi/ TF_ !n/(97<jNExp. Date: -) /1-/7-07 S City Business Lic No: 30% SLOPES ON PROPERTY: Cost of Project: $ 73/0.00 **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: l,Z l DIMENSIONS: �O X?.O # OF STORIES: ( TOTAL HABITABLE SPACE: i oo D ` MAIN FLOOR TO SQ. FTG: 2ND FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: o(1- -/C0a ' DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature Method of Payment: (Faxed permit applica 0 Cash 0 Check Bankcard #: Date Cv` O—o(0 s will only be accepted with major bankcard) 0 Mastercard 0 VISA Expires: VIN#: 0 Other Authorized Signature: REVISED 8/25/2005 8pflflW* 91)1AVV401.41ACSIOITIA s :slid iAi Ojoi MOM t �i� 1 3 X X39 A+ UQR aoinui sit)=* IRA WOO Otiffilie t+>BUILDING DEPARTMENT 11707 E. Sprague Avenullpokane Valley, Washington 99206 - TO 509-688-0036 - Fax 509-688-0037 Following is a typical cross-section for a residential garage. It may not represent the proposed project If you are using this detail as a portion of your plan submittal, please complete the requested information in the boxes provided on both sides of this sheet This completed sheet, along with any additional information needs to be submitted with your aplication and be on site at the time of inspection. PROTECTION AND OPENINGS BETWEEN DWELLINGS AND PRIVATE GARAGES SHALL HAVE: 1) MATERIALS APPROVED FOR ONE HOUR FIRE RESISTIVE CONSTRUCTION ON THE GARAGE SIDE: • 5/8" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) ` 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING) 2) OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOOR, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8", OR 20 MINUTE FIRE RATED DOORS. ALTERNATE FOUNDATION FOR ACCESSORY BUILDINGS FROM 400 SQ. FT. TO 3000 SQ. FT. SECTION A -A it: JAI OT NOTE: Diagonal wall bracing required on each comer and every 25 feet of wall. Walls within 3 feet of a property line or within 6 feet of a dwelling must be 1 hour rated. (5/8" type X" gypsum sheathing on both sides of waif). Openings are not permitted in these walls. Garages over 3,000 sq. ft. require protection when closer than 20 feet to the property fine. Parapets may be required. '119M0‘) ') 01 .1 12q * 000E 8JJAV '" ENGINEERED TRUSS OR 8T ocIPA3 ,23OA0;R?kFTER SIZE AND SPACING I?(1 * wee - 23H')ROrr /6 1/8" GAP BE WEEN SHEATHIN 1`4"i I /f` ROOF SHEATHING 6" MIN. 24"MIN. (2) /4 REBAR ROOFING MATERIAL ROOFING PAPER 0. Ua. 7 CO m y � ., c o U. C (./) . co eu a > •3 CL 0 —T°0 viii m 0 tic Accessible b 22'x30" SOLID BLOCKING BETWEEN.TRUSSES WALL SHEATHING AAAI/ %%`, SIDING 6" MIN. DOUBLE TOP PLATE WALL HEIGHT O.C. PRESSURE TREATED SOLE PLATE 3-12" CONCRETE SLAB 24" MIN. 6" Mi1r'i • ANCHOR BOLTS 12"x9" MIN. (7" INTO CONCRETE) 6' O. C. OR APPROVED 6"x12' ANCHOR INSTALLED FOOTING PER MANUFACTURER CEILING: '/2" GWB if perpendicular to rafters or trusses 24" o.c. and no water based texture used— otherwise 5/8" GWB. FOUNDATION PLAN mem INTERIOR ALTERATIONS, ROM OR AOOITI01I REQUIRING A PERMIT OCCORAMMIBI ONE OR MOUE SLEEPING ROOMS ARE ADDED OR MATEO IN E>N$TII16 DWELLINGS. THE MUMS UNIT SHALL SE FRO NTH SMOKE ALARMS LOCATED AS REWIRED FOR NNW DWELLINGS. PLEASE COMPLETE THE FOLLOWING INFORMATION AND ADD ON T-ll�d�?Ay RFmrumlNagESg�WE BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS. VAULTED CEILING WITH RISE OF 24. & ON EACH FLOOR) INDICATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON THE PLAN. BUILDING DIMENSIONS: GARAGE OPENING AND HEADER SIZE: fvlfa V Z W J a> RIDGE LANE WIDTH CONCRETE TO COMPLY TP IRC TABLE 404.1.1(1) .DATION WALLS SLABS, GARAGES, CI & PORCHES - 3; ALL FOOTINGS MUST E 3000 # PSI PORTS IO#PSI ,ONTINUOU$ PROTE4TION AND OPENINGS BETWEEN DWELLING ND PRIVATE i;AAAGE SHALL HAVE: µl<l') 1) MATER !ALS A PROVED FOR ONE HOUR FIRE RESISTIVE 1�'I� CONSTRUCTION N THE GARAGE SIDE: Or) 1-1 Awa-" ❑ 5/8" TYPE "X" YP BOARD (HABITABLE SPACE ABOVE) OR ❑ 1/2" GYP BOARD (RESIDENCE/ATTIC. FLOOR/CEILING) 2 OPENINGS BE1INEEN GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH 90LI0 WOOD DOOR, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8", OR 20 MINUTE FIRE RATED DOORS. LxLS Tivvc,G •e4c e lel 2, • f MoNc 4Trf Ic: , SLA B ' . /:?->4 (:, WAIS Please note that while every effort is made to assure the accuracy of the information contained in this brochure is not warranted for accuracy. This document is not intended to address all aspects or regulatory requirements for a project and should serve as a starting point for your investigation. For detailed information on a particular project, permit, or code requirement refer directly to applicable file and/or code/regulatory documents or contact the appropriate division. Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4 Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6 Min. 16, 18 or 20 in. APA Portal Frame Bracing Engineered Shear Wall Bracing FROM :UNIVERSITY HIGH SCHOOL D EIDE WE JUN 2 0 2006 [7)) DAB DEIN FAX NO. :5092285249 Jun. 20 2006 10:24RM P1 PLANNING By. :�� �- 7b( gffi 06-20-2006 10:30 WHITE WATER CONSTRUCTION 5092996E164 PAGE1 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS THESE PLANS MUST BE KEPT ON THE JOB SITE. THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS adoe� y REVIEWED FOR CODE COMPLIANCE SPOKANE VALLA F "" SING DIVISION