2012, 11-09 Energy Code Lettert Duct Leakage Affidavit Permit #: House address or lot number: -7 o -7 i i 1--/a- q city: Seo h �C V 1 y zip: Cond. Floor Area (ft): r 0 Source (circle one): Plans Es at Measured ❑ Duct tightness testing is not required for this residence per exceptions listed at the end of this document Air Handler in conditioned space? ❑ yes [9 no Circle Test Method: L�akage o ' e Air Handler present during test? Dyes ❑ no Total Leakage Maximum duct leakage: Post Construction, total duct leakage: (floor area x .08) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x.06) = CFM@25 Pa Rough4n, total duct leakage with air handler installed: (floor area x.06) = 1 y � CFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x.04) = CFM@25 Pa Test Result: O Z CFM@25Pa Rina (circle one if aDDlicable): Open n5 2 3 Duct Tester Location: " r % r Y Pressure Tap Location: - (Ar4 I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. `J Company Name: a L �--I Technician: �2r'. tJ I -I Technician Signature: Date: // Phone Number: Washington State Energy Code reference: 603.10.3 89sling. All ducts, air handlers, filter boxes, and building cavities used as ducts shall be sealed. Joints and seams shall comply with Section M1601.3 of the International Residential Code or 603.9 of the International Mechanical Code. Duct tightness testing shall be conducted to verify that the duds are sealed. A signed affidavit documenting the test results' hall be provided to the jurisdiction having authority by the testing agent. When required by the building official, the test shall be conducted in the presence of department staff. Exceptions: 1. Duct tightness test is not required if the air handler and all ducts are located within conditioned space. 2. Duct testing is not required if the furnace is a nondirect vent type combustion appliance installed in an unconditioned space. A maximum of six feet of connected ductwork in the unconditioned space is allowed. All additional supply and return ducts shall be within the conditioned space. Ducts outside the conditioned space shall be sealed with a mastic type duct sealant and Insulated on the exterior with R-8 insulation for above grade ducts and R-5 water resistant insulation when within a slab or earth. Property Address: -7 9 7 Y 'Fko(-c,, Conditioned Floor Area IS00 Builder or registered design professional: Ceiling: Vaulted R-_ Attic R - Walls: Above grade R - Below, int. R-_ Below, ext. R- NFRC rating (or) Default rating (Chapter 10 WSEC 2009) DHW Property Address: -7 0 % 0 OU,7, Date Conditioned Floor Area 1 1�4' .00 Date Builder or registered design professional: Floors Over unconditioned space R - Slab on grade floor R - Doors R- R- R- zZon mit Windows U- SHGC- Skylights U- SHGC- All ducts & HVAC in conditioned space (yes /U} Insulation R - Test Method: •Total leakage Leakage to exterior Air handler present Test Target 0% CFM@25Pa Test Result CFM@25Pa Building air leakage target: SLA<0.00030 - Tested leakage: SLA= A Ceiling: Vaulted R- Atti c R - Walls: Above grade R - Below, int. R - Below, ext. R- NFRC rating (or) Default rating (chapter i o wsEc zoog) I BUM Floors Over unconditioned space R - Slab on grade floor R - Doors R- R- R - Windows U- SHGC- Skylights U- SHGC- Effidenry zpad&BsNft Meat All ducts & HVAC in conditioned space yes filo Insulation R- Test Method: Totalleakage —Leakage to exterior Air handler present Test Target I CFM@25Pa Test Result �2_ CFM@25Pa Building air leakage target: SLA<0.00030 - Tested leakage: SLA -- System type: Rated annual generation Kwh System type: Rated annual generation Kwh