Loading...
2013, 06-07 Permit App: BLD-2013-1056 Residence•,"\ft. Spokane do•OValley. Community Development Department Permit Center 11703 East Sprague Avenue, Suite B-3 Spokane Valley, WA 99206 Tel: (509) 688-0036 Fax: (509) 688-0037 permitcenter@spokanevallev.orq «1- ze73 - /03-4, (Staff Use Only) PERMIT NUMBER: PERMIT FEE: RESIDENTIAL CONSTRUCTION PERMIT APPLICATION ►:1 NEW CONSTRUCTION ❑ ADDITION/REMODEL ❑ ACCESSORY BUILDING ❑ DECK ❑ OTHER SITE ADDRESS: 2611 N Fox ASSESSORS PARCEL NO.: LEGAL DESCRIPTION: L 16, B3 View Ranch BUILDINi OWNER NAME: NAME: SVG View Ranch LLC ADDRESS: 2910 E 13th Avenue CITv: Spokane, STATE: WA ZIP: 9 9 2 0 2 PHONE: 509 951 0239 Fax: 534 1152 CELL: 951 0239 CONTACT NAME: Carlos F Landa PHONE: 509 951 0239 FAX: 534 1152 CELL: 951 0239 CONTRACTOR NAME: P@ Builders LLC MAILING ADDRESS: 2910 E 13th Aveenu Clnr: Spokane STATE: WA ZIP: 99202 PHONE: 509 951 0239 FAX: 534 1152 CELL: 951 0239 CONTRACTOR LICENSE NO.: on file EXPIRES: CITY BUSINESS LICENSE NO.: DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE: Build 1,324 SF Single Familyt Residence ****YOU MUST COMPLETE THE FOLLOWING**** MARK N/A IF NOT APPLICABLE Height to Peak: 16 Dimensions: 40 x 52 No. of Stories: 1 Total Habitable, Space: I, l 4 Main Floor SQ FT: 1,324 Upper Floor SQ FT: 0 Unfinished Basement SQ FT: none Finished Basement SQ FT: none Garage SQ FT: 400 Deck/Covered Patio SQ FT: 1 3 0 Impervious Surface Area: 1856 30% Slopes on Property: none No. of Bedrooms: 3 Construction Type: WF Heat Source: FAG rie;"el or Septic: TOTAL COST OF PROJECT: $ 1Oo 000 DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subsequently approved before this application can be processed. Effective October 28, 2007 Page 1 of 2 P:\Community Development\02 Administration\03 Forms - Official Versions\Permit Center\Residential Construction Permit App 10.28.07.doc +- L36 z co v9 N o O 0 O m YY� 1' S 00°00'00" E N 00°00'00" E 30.00' N 00°00'00" E 14.00' 26.00' Z 0 0) 0 0 0 0 0 0 0, O ,all-vw,la d (p o (Do -'O 1c3 0 ,o 6!1 N Tai + SPOKANE COUNTY UTILITIES PERMIT Application Number: SW -13000652 Permit Issued Date: 05/09/2013 Expiration Date: 05/09/2014 Project Description: Project Name: Primary Contact: Phone: SEWER CONNECTION VIEW RANCH ESTATES SVG VIEW RANCH, LLC 509-951-0239 Applicant: SVG VIEW RANCH, LLC Address: Phone: Email: 2910 E 13TH AVE SPOKANE, WA 99202 509-951-0239 SITE INFORMATION: Site Address: Parcel Number: 2611 N FOX LN 45091.3015 Assessor's Description: VIEW RANCH ESTATES (AFN 5478998) LT 15 BLK 3 Inspection Area: : (509)-477-3675 Zoning: Owner: Address: Phone: Email: Water District: Irvin Water District #6 SVG VIEW RANCH, LLC 2910 E 13TH AVE SPOKANE, WA 99202 509-951-0239 Fire District: Spokane Valley Fire Land Area: 4890 Square Feet CONTRACTOR INFORMATION: HAWKICC044KN, Exp. 05/15/2014 HAWKINS CONSTRUCTION CO 13718 E 41ST AVE SPOKANE, WA 99206 509-922-1047 DETAILS: Class Type Quantity Unit Charge Value SEWER SEWER CONNECTION FEE DETAIL: Processing - Utilities Utilities Permit Total Fee: $26.32 $125.00 $151.32 1 $125.00 $125.00 $125.00 CONDITIONS: Inside Public Transit Benefit Area Plan review fee is required for all site plan reviews conducted by Spokane Valley Fire. CALL 1-800-424-5555 BEFORE YOU DIG --AT LEAST 2 WORKING DAYS IN ADVANCE. SPOKANE COUNTY CODE REQUIRES THE INSTALLER COMPLY WITH ALL REQUIREMENTS OF THE WA STATE DEPT OF LABOR & INDUSTRIES, INCLUDING THOSE RELATED TO TRENCH SAFETY. SEWER PERMITS ARE VALID FOR ONE (1) YEAR FROM THE DATE OF ISSUANCE. FOR SEWER INSPECTIONS CALL THE UTILITIES DEPT AT (509) 477-3604 FROM 8:30-5:00 MONDAY -FRIDAY PRIOR TO COVER. ONE WORKING DAY NOTICE REQUIRED. PERMIT ALLOWS FOR A 30 -MINUTE INSPECTION. ADDITIONAL INSPECTION FEES APPLY AFTER 30 MINUTES. INSTALLER IS RESPONSIBLE TO INSURE ALL WASTEWATER DRAINS ARE CONNECTED TO THE SEWER AND MAY BE REQUIRED TO PERFORM TESTS FOR VERIFICATION. INSTALLER IS TO FIELD LOCATE AND CONFIRM THE ELEVATION AND POSITION OF SEWER STUB PRIOR TO ANY OTHER EXCAVATION. Date Printed: 05/09/2013 12:22:13 Project Coordinator: Julie Shatto SPOKANE COUNTY UTILITIES PERMIT Application Number: SW -13000652 Permit Issued Date: 05/09/2013 Expiration Date: 05/09/2014 SEWER STUBS AND DRY SIDE SEWERS ARE TO BE CHECKED PRIOR TO CONNECTION TO ENSURE THAT THEY HAVE ACCEPTABLE GRADE AND ARE CLEAR AND UNOBSTRUCTED. SEWER LINES SHOULD BE CONSTRUCTED TO ALLOW FOR GRAVITY FLOW FROM THE LOWEST LEVEL OF THE STRUCTURE. THE INSTALLER AND THIS PERMIT MUST BE PRESENT AT THE JOB SITE AT THE SCHEDULED INSPECTION TIME. BOTH STATE LAW RCW 19.122 AND COUNTY CODE REQUIRES THE INSTALLER TO GIVE NOTICE OF EXCAVATION TO OWNERS OF UNDERGROUND FACILITIES. Date Printed: 05/09/2013 12:22:13 Project Coordinator: Julie Shatto 1 TAS Technical Assistance Services Garden Court Building, 222 W. Mission Avenue. Suite 234, Spokane, WA 99201 (509) 325-4476 FAX (509) 325-4587 05/20/13 City of Spokane Valley Building Department 11707 E. Sprague, #106 Spokane Valley, WA Project: Single Family Residence Total Area: 1314 sq.ft. Address: 2611 N. Fox Lane Spokane Valley Contractor/Phone: Carlos Landa / 951-0239 Glazing Percentage: 13.7% PROJECT COMPLIES with TABLE 5-1/ TARGET COMPONENT VALUES FOR GROUP R OCCUPANCY, 2009 Washington State Energy Code. ALLOWABLE HEAT LOSS (Btu/h/deg.F) Glazing: 15% 1314 sq.ft.-- 197.1 @ U .30 Doors: 40 sq.ft. @ U .20 Ceiling (Attic): 1320 sq.ft. R38 ADV or R49 STD @ U .027 Walls (1658 gross sq.ft.): 1467 sq.ft. R21 INT @ U .056 Floor: 1314 sq.ft. R30 @ U .029 = 59.1 = 8.0 = 35.6 = 82.2 = 38.1 TOTAL UA ALLOWABLE = 223.0 660-v /, /0c6. PROPOSED HEAT LOSS (Btu/h/deg.F) Glazing (13.7%): 115.7 sq.ft.vinyl operable w/low-E @ U .34 45 sq.ft.vinyl fixed w/low-E @ U .31 19 sq.ft insulated full light door w/low-E @ U .28 Doors: 21 sq.ft. insulated w/ small glass light @ U .20 19 sq.ft. insulated @ U .16 Ceiling: 909 sq.ft. R38 5:12 STD truss @ U .030 421 sq.ft. R38 5:12/2:12 Scissor Truss @ U .031 Walls: 1470 sq.ft.R21 INT horiz. Siding @ U .054 Floor: 1314 sq.ft. R30 @ U .029 2611 N. Fox Lane = 39.3 = 14.0 5.3 = 4.2 = 3.0 = 27.3 = 13.1 = 79.4 = 38.1 TOTAL PROPOSED HEAT LOSS = 222.9 222.9 Btu/h < 223.0 Btu/h -- Project complies w/ Table 5.1 Edward R. Fields Technical Assistance Services ESTIMATED HEAT LOSS CALCULATION For System Sizing Building Identification: 2611 N. Fox Lane Interior Temperature: 70 deg.F Exterior Temperature: 4 deg.F (Spokane) Temperature differential: 66 deg.F Component Heat Loss: 222.9 Btu/h per hour x 66 deg. temp. differential Air Leakage Heat Loss (Volume = 12295 cu.ft.): .018 x 12295 cu.ft. x 66 deg.= 14606 14606 x .60 air change per hour Building Design Heat Load Duct Heat Load Multiplier (Ducts in unconditioned space): 1.15 x 23,337 Btu/h ESTIMATED TOTAL HEAT LOSS (Maximum Btu/h) : 26,996 Btu/h x 150% = 14,711 Btu/h = 8,764 Btu/h 23,475 Btu/h = 26,996 Btu/h = 40,494 Btu/h NOTE: This is an estimated heat loss for building permit purposes only. Input Btu/h required depends on the efficiency of the equipment (fuel fired)-- divide the Estimated Total Heat Loss by the % efficiency of furnace to be used. EXAMPLE: 40,494 Btu/h / 92% efficiency = 44,016 Btu/h input. When sizing the furnace, pick a unit with a factory input Btu/h that is the closest to the calculated input required but greater than, not less than, the required input. Electric resistance heating is considered 100% efficient. It is the mechanical contractor's responsibility to size the system.