2015, 05-07 Energy Compliance CertificateProperty Address:
10 s 6-krki
Date: S / 7 I joy
Conditioned Floor Area: 157,0
Builder or registered design professional :
oc, ����� w s
Signature:
R -Values
Ceiling: Vaulted R- Floors: Over unconditioned space R -
Attic R- 46 Slab on grade floor R- / O
Walls: Above grade R- 21 Doors: 1 1 1 AGA R. /„.2s-
Below,
•ZSBelow, int. R- G (�.2� ( R- 3.3
Below, ext. R- R-
U -Factors and SHGC
NFRC rating (or) Windows U- , 3 0 SHGC- N/A
Default rating (Appendix A WSEC 2012) Skylights U- SHGC- N/A
Table 406.2 Option(s) 3A
Total 406.2 Credits
Heating, Cooling & Domestic Hot Water
System
Type
Efficiency
Heating
i-orce GQ Acv
s-9„
Cooling
Electric central
3 S,...teP.
DH W
6- s so 6w(
Duct & Building Air Leakage
All ducts & HVAC in conditioned space
Air handler present
Test Target (Q CFM(c25Pa
Insulation R -
Test Result CFMg25Pa
Building air leakage target: ACII50 < 5.0 - Tested leakage: ACH50 _ -2,
System type:
Onsite Renewable Energy Electric Power System
Rated annual generation Kwh
LOOSE- FILL
INSULATION CERTIFICATE
Part 1 Weatherization Division Eagle Insulation Inc,
Contractor IEEL Form No. 8403 Reg# RCE 2647
Viking Builders 11017 N Government Way
Job# 403 Hayden, ID 83835
105 Grady Grady St - 208-762-1189
Part 2
Ceiling areas Insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R -Value of bags Baq Depth Type Name
0 38 0 25 10.3" Cellulose Thermoguard
248 49 Fiberglass Knauff
0 Foam Brd R Max
0 19 0 25 5.15" Cellulose Thermoguard
1279 49 82 25 13.3" Cellulose Thermoguard
O 60 0 25 16.1" Cellulose Thermoguard
Part 3 Wall areas insuklated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R -Value of bags Baq Depth Type Name
8 2" Fiberglass Knauff
0 11 3" Fiberglass Knauff
0 13 3.5" Fiberglass Knauff
0 15 3.5" Fiberglass Knauff
107 19 6.5" Fiberglass Knauff
1349 21 5.5" Fiberglass Knauff
0 13 0 25 3.5" Cellulose Thermoguard
0 21 0 25 5.5" Cellulose Thermoguard
_Part 4 Floor or rim joist areas insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R -Value of bags Bag Deoth Tvpe Name
0 11 3.5" Fiberglass Knauff
O 13 3.5" Fiberglass Knauff
0 15 3.5" Fiberglass Knauff
O 19 6.5" Fiberglass Knauff
0 21 5.5" Fiberglass Knauff
0 25 8" Fiberglass Knauff
0 30 9" Fiberglass Knauff
0 38 12" Fiberglass Knauff
0 30 0 25 10" Cellulose Thermoguard
Part 5 Foundatio walls insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R -Value of bags Bag Depth Type Name
0 8 2" Fiberglass Knauff
0 11 _3.5" Fiberglass Knauff
0 19 6.5" Fiberglass Knauff
Part 6
SQ FT 0 Installed 6 mil vapor barrier in crawler
Yes 1 Meets Washington State work Compliance Sheet
SQ FT 2050 Installed poly vapor barrier on all exterior warm side walls
SQ FT 0 Insulated water pipes R-8
SQ FT 200 Insulated heater plenum and hard ducts with R-8 insulation
40" Baffles 0 Installed cardboard or foam vents at trus heals
60" Baffles 52 Installed cardboard or foam vents at trus heals
Foam Vents 0 Installed cardboard or foam vents at trus heals
Eagle Insulation Inc. certifies that the above residence identifies in part 1 was insulated,
inspected by local Building Depts. As specified in part 2,3,4,5 and 6 and the installation was
conducted in performance to applicable codes, standards and regulations at time of
Installation
Authorized Signature
Date Installed: 4/6/15