2006, 08-14 Permit App: 06003171 Temporary RampProject Number: 06003171 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 8/14/2006 Page 1 of 2
Project Information:
Permit Use: TEMPORARY RAMP
Setbacks: Front Left:
Site Information:
Plat Key:
Right:
Name: Range
Rear:
Contact:
Address:
C - S - Z:
Phone:
Group Name:
Project Name:
T & J CONSTRUCTION
4131 E CONGRESS
SPOKANE, WA 99223
(509) 435-7118
District: East
Parcel Number: 55181.3210 Block:
SiteAddress: 1022 N GREENACRES RD
Location:: CSV
Zoning: UR -3.5
Water District:
Area: .92 Acres
Urban Residential 3.5
Width: 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information:
Review
Building Plan Review
Permits:
Lot:
Owner: Name:
Address:
GEHRKE, C A
1022 N GREENACRES RD
SPOKANE VALLEY, WA 99016
Hold: ❑
Depth: 0 Right Of Way (ft): 0
91
Originally Released:
Contractor: T & J CONSTRUCTION
Address: 4131 E CONGRESS
SPOKANE, WA 99223
Released By:
Description Type Notes
DECK OPEN R-3 VB temporary
ramp
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Operator: AMB
8/14/2006 By: TMELBOU
Building Permit
Totals:
Units
1
1
1
Printed By: AMB
Firm: T & J CONSTRUCTION
Phone: (509) 435-7118
This Application:
Sq Ft Valuation
0 $1,500.00
0 $1,500.00
Unit Desc
SELECT
SELECT
SELECT
Permit Total Fees:
Print Date:
Total Project:
Sq Ft Valuation
0 $1,500.00
0 $1,500.00
Fee Amount
$69.25
$4.50
$27.70
$101.45
8/14/2006
Project Number: 06003171 Inv: 1
Notes:
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 8/14/2006 Page 2 of 2
Payment Summary:
Permit Type
Building Permit
Fee Amount Invoice Amount
$101.45 $101.45
Amount Paid
$0.00
Amount Owing
$101.45
$101.45 $101.45 $0.00 $101.45
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB Print Date: 8/14/2006
Project Number: 06003171 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 8/11/2006 Page 1 of 1
Project Information:
Permit Use: TEMPORARY RAMP
Setbacks: Front Left: Right: Rear:
Site Information:
Plat Key: Name: Range
Contact: T & J CONSTRUCTION
Address: 4131 E CONGRESS
C - S - Z: SPOKANE, WA 99223
Phone: (509) 435-7118
Group Name:
Project Name:
:41%2N/ENEPARreMEDMETAMROMFEEMMON
District: East
Parcel Number: 55181.3210 Block:
SiteAddress: 1022 N GREENACRES RD
Location:: CSV
Zoning: UR -3.5
Water District:
Area: .92 Acres
Urban Residential 3.5
Width: 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information,
Lot:
Owner: Name: GEHRKE, C A
Address: 1022 N GREENACRES RD
SPOKANE VALLEY, WA 99016
Hold: ❑
Depth: 0 Right Of Way (ft): 0
Review
Building Plan Review
Permits:
Released By: Tim �• L
Contractor: T & J CONSTRUCTION
Address: 4131 E CONGRESS
SPOKANE, WA 99223
Notes:
Building Permit
rg-RITetrUrrarreda
Firm: T & J CONSTRUCTION
Phone: (509) 435-7118
Payment Summary � ��Mgr r MrrM m .... ,O saN, nT a
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB Print Date: 8/11/2006
7' Permit Center
'nakar> e 11707 E Sprague Ave, Suite 106
ValleSpokane Valley, WA 99206
Y (509)688-0036 FAX: (509)688-0037
Community Development www.spok_anevalley.or,.com
Residential Construction
Permit Application
✓ 4
PERMIT NUMBER: 3/-7
PERMIT FEE:
I evv Construction
❑ Addition/Remodel
o Other:
o Accessory Bldg
❑ Deck
SITE ADDRESS / b7-2. /17- - p_t ) ac,,, 5
ASSESSORS PARCEL NO:
LEGAL DESCRIPTION:
Building owner
Name: C_L r €.ice 6- ell. /'k.e
Address: /p 3-2_ A/- (-teon cr ed -es Atf
City: fry,,ie /c //e/ Zip:
Phone: 926- 7035/Fax:
Contact Person
Name: TAM S
Phone: 1/3.5-- 7//
Describe the scope of work in detail:
/o b61 /ee -/-eit-Iterty
Contractor
Name: cfitOY 7-1'`r con SfA:41' 74 o r c.,
Address: q/3/ L:: (-704,J"P9,5
City: /c` -"e- Zip:jr"'2.,Z$
Phone: 4,35-- - 7//E-' Fax: 5-31" —3 y7 /
Lic No:'! T�/t7C °I6 7 ,Exp. Date: 2- / 7-07.
City Business Lic No:
Cost of Project:
**************The following MUST be complete: (write N/A if not annlicable)**********************
HEIGHT TO PEAK:
DIMENSIONS:
# OF STORIES:
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
FTG:
2Nu FLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
IMPERVIOUS SURFACE
AREA:
FINISHED BASEMENT
SQ. FTG:
GARAGE SQ. FTG:
DECK/COV. PATIO SQ. FTG:
30% SLOPES ON
PROPERTY:
# OF BEDROOMS:
CONSTRUCTION TYPE:
HEAT SOURCE:
SEWER OR SEPTIC?
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed.
Signature
Date C-17— c90
Method of Payment: (Faxed permit applications will only be accepted with major bankcard)
0 Cash 0 Check ❑ Mastercard 0 VISA
Bankcard #: Expires: VIN#:
Authorized Signature:
REVISED 8/252005
0 Other
R311.5.6.3 Handrail grip size. All required handrails
shall be of one of the following types or provide equiva-
lent graspability.
1. Type I. Handrails with a circular cross section shall
have an outside diameter of at least 1'/4 inches (32
mm) and not greater than 2 inches (51 mm). If the
handrail is not circular it shall have a perimeter di-
mension of at least 4 inches (102 mm) and not
greater than 6'/4 inches (160 mm) with a maximum
cross section of dimension of 2'/4 inches(57 mm).
2. Type II. Handrails with a perimeter greater than 6'/4
inches (160 mm) shall provide a graspable finger re-
cess area on both sides of the profile. The finger re-
cess shall begin within a distance of 3/4 inch (19 mm)
measured vertically from the tallest portion of the
profile and achieve a depth of at least 5/,6 inch (8
mm) within 7/8 inch (22 mm) below the widest por-
tion of the profile. This required depth shall con-
tinue for at least 3/8 inch (10 mm) to a level that is not
less than 13/4 inches (45 mm) below the tallest por-
tion of the profile. The minimum width of the hand-
rail above the recess shall be 1'/4 inches (32 mm) to a
maximum of 23/4 inches (70 mm). Edges shall have
a minimum radius of 0.01 inches (0.25 mm).
R311.5.7 Illumination. All stairs shall be provided with il-
lumination in accordance with Section R303.6.
R311.5.8 Special stairways. Circular stairways, spiral
stairways, winders and bulkhead enclosure stairways shall
comply with all requirements of Section R311.5 except as
specified below.
R311.5.8.1 Spiral stairways. Spiral stairways are per-
mitted, provided the minimum width shall be 26 inches
(660 mm) with each tread having a 71/2 -inches (190 mm)
minimum tread depth at 12 inches from the narrower
edge. All treads shall be identical, and the rise shall be no
more than 91/2 inches (241 mm). A minimum headroom
of 6 feet 6 inches (1982 mm) shall be provided.
R311.5.8.2 Bulkhead enclosure stairways. Stairways
serving bulkhead enclosures, not part of the required
building egress, providing access from the outside grade
level to the basement shall be exempt from the require-
ments of Sections R311.4.3 and R311.5 where the maxi-
mum height from the basement finished floor level to
grade adjacent to the stairway does not exceed 8 feet
(2438 mm), and the grade level opening to the stairway is
covered by a bulkhead enclosure with hinged doors or
other approved means.
R311.6 Ramps.
R311.6.1 Maximum slope. Ramps shall have a maximum
slope of one unit vertical in eight units horizontal (12.5 -per-
cent slope).
R311.6.2 Landings required. A minimum 3 -foot -by -3 -foot
(914 mm by 914 mm) landing shall be provided:
1. At the top and bottom of ramps,
2. Where doors open onto ramps,
3. Where ramps change direction.
2003 INTERNATIONAL RESIDENTIAL CODE®
BUILDING PLANNING
R311.6.3 Handrails required. Handrails shall be provided
on at least one side of all ramps exceeding a slope of one unit
vertical in 12 units horizontal (8.33 -percent slope).
R311.6.3.1 Height. Handrail height, measured above the
finished surface of the ramp slope, shall be not Less than
34 inches (864 mm) and not more than 38 inches (965
mm).
R311.6.3.2 Handrail grip size. Handrails on ramps
shall comply with Section R311.5.6.3.
R311.6.3.3 Continuity. Handrails where required on
ramps shall be continuous for the full length of the ramp.
Handrail ends shall be returned or shall terminate in
newel posts or safety terminals. Handrails adjacent to a
wall shall have a space of not less than 1.5 inches (38
mm) between the wall and the handrails.
SECTION R312
GUARDS
R312.1 Guards required. Porches, balconies or raised floor
surfaces located more than 30 inches (762 mm) above the floor
or grade below shall have guards not less than 36 inches (914
mm) in height. Open sides of stairs with a total rise of more than
30 inches (762 mm) above the floor or grade below shall have
guards not less than 34 inches (864 mm) in height measured
vertically from the nosing of the treads.
Porches and decks which are enclosed with insect screening
shall be provided with guards where the walking surface is lo-
cated more than 30 inches (762 mm) above the floor or grade
below.
R312.2 Guard opening limitations. Required guards on open
sides of stairways, raised floor areas, balconies and porches
shall have intermediate rails or ornamental closures which do
not allow passage of a sphere 4 inches (102mm) or more in di-
ameter.
Exceptions:
1. The triangular openings formed by the riser, tread and
bottom rail of a guard at the open side of a stairway are
permitted to be of such a size that a sphere 6 inches
(152 mm) cannot pass through.
2. Openings for required guards on the sides of stair
treads shall not allow a sphere 43/8 inches (107 mm) to
pass through.
SECTION R313
SMOKE ALARMS
[F] R313.1 Smoke alarms. Smoke alarms shall be installed in
the following locations:
1. In each sleeping room.
2. Outside each separate sleeping area in the immediate vi-
cinity of the bedrooms.
3. On each additional story of the dwelling, including base-
ments but not including crawl spaces and uninhabitable
attics. In dwellings or dwelling units with split levels and
without an intervening door between the adjacent levels,
51
WASHINGTON STATE AMENDMENTS
8311.6.3.3 Continuity. Handrails where required on ramps
shall be continuous for the full length of the ramp. Handrail
ends shall be returned or shall terminate in newel posts or
safety terminals. Handrails adjacent to a wall shall have a
space of not less than 1.5 inches (38 mm) between the wall
and the handrails. At least one handrail shall extend in the
direction of ramp run not less than 12 inches (305 mm)
horizontally beyond the top and bottom of the ramp runs.
(Insert Facing Page 52)
CITY COPY
10 INSPECTION CORRECTIONS
bpolix-E
,----.-,5\a4
REVIEWEC FOk .LE COMPLIANCE
lc
SPOKANE '.',A.1.1.FY uns.) .G DIVISION
--ri-- ti oio