Loading...
2006, 01-23 Permit App: 06000138 RemodelProject Number: 06000138 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 01/23/2006 Page 1 of 2 Project Information: Permit Use: INSTALL SOFIT, INSULATION, DRYWALL, Contact: ROBERT HAZELBAKER RELOCATE WATER LINE-HOSEBIB Address: 1523 S HERALD RD C - S - Z: SPOKANE VALLEY WA 99206 Setbacks: Front Left: Right: Rear: Phone: (509) 924-4046 Group Name: Site Information: Project Name: Plat Key: 000000 Name: Range District: Sout Parcel Number: 45204.3942 Block- SiteAddress: 1523 S HERALD RD Location:: CSV Zoning: UNKN Unknown Water District: Lot: Owner: Name: MARTIN, MARYJORIA I Address: 1523 S HERALD RD SPOKANE VALLEY WA 99206 Hold: ❑ Area: .00 Acres Width: 100 Depth: 118 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review Information: Permits: Building Permit Contractor: OWNER Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation I&2 FAMILY R-3 VB BASEMENT 0 $7,000.00 0 $7,000.00 REMODEL Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Contractor: OWNER Item Description MISCELLANEOUS FIXTURES Totals: 0 $7,000.00 0 $7,000.00 Units Unit Desc Fee Amount 1 SELECT $139.25 1 SELECT $4.50 1 SELECT $55.70 Permit Total Fees: $199.45 Plumbing Permit Firm: OWNER Phone: (000) 000-0000 Units Unit Desc I NUMBER OF Operator: jmm Printed By: CJJ Fee Amount $6.00 Permit Total Fees: $6.00 Print Date: 01/23/2006 Project Number: 06000138 Inv: 1 Application Date: 01/23/2006 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes • Payment Summary: , Permit Type Fee Amount invoice Amount Amount Paid Amount Owing Building Permit $199.45 $199.45 $0.00 $199.45 Plumbing Permit $6.00 $6.00 $0.00 $6.00 $205.45 $205.45 $0.00 $205.45 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: jmm Printed By: CJJ Print Date: 01/23/2006 Spokane Valley Community Development Permit Cente 11707 E Spr Spokane Val (509)688-0036 www.spokan S e 1106 V E A 99206 I J FAX: (509j6881002j7 '.ors.com �1 D Residential Construction Permit Application PERMIT NUMBER: 03r(5' PERMIT FEE: UBLOUNI • New Construction t$LAddition/Remodel o Other: o Accessory Bldg o Deck SITE ADDRESS 113 3 S Fie 2f} Ld Rid ASSESSORS PARCEL NO: Li 5&O'1 , 69' 44_ LEGAL DESCRIPTION: Building owner An-(� To�'4 -, -time[l�/,;: Name: �) Address: /$02 -R ,$ iefizi • Rd- dCity: City;Ofrop iktryZip: q7 g,,,, In Phone: l720 t{D Fax: =Contact Peison'. - Name: ic,r,hnp Phone: (i --it 0 t( (p Contractor DIMENSIONS: Name: TOTAL HABITABLE SPACE: Address: 2"u FLOOR SQ. FTG: City: Zip: Phone: Fax: ' Lic No: Exp. Date: City Business Lic No: CONSTRUCTION TYPE: Describe the scope of work in detail: Cost of Project: eters Rope..� to t r t /4'Sc,Lytre_ 02 it c w'lit )nsoL -n 1 �7P unit t— O[l%fd4–, Fa-coeTrr 0 >hoLcoli f-eD ttitrt--tet? stn, jT t **************The followine MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: 2"u FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: go7„ 2— GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? DISCLAIMER • The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with/the pity of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Centter. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can bprocessed. Signature i Method of Payment! ❑ Cash Bankcard #: (Faxed permit 0 Check Authorized Signature: REVISED 8/25/2005 Date ///-0 6 plications will only be accepted with major bankcard) ❑ Mastercard ❑ VISA Expires: VIN#: 0 Other WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°.1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Option Glazing %Area": of floor Glazing U -Factor Door9 U-Ceiling2 Factor Vaulted Ceiling3 Wall12 Above Grade Wall? int Below Grade Wall?4 Below Grade Floors Slab6 on Grade Vertical Overhead" I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-5° III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 IV. 25% 0.35 0.58 0.20 R-38 / R-301 R-21 R-15 R-12 R-30 / R-10 / Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 Occupancy U=0.054 Only V. Unlimited Group R-3 0.35 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 Occupancy Only VI. Unlimited 0.32 0.58 0.20 R-381 R-30 / R-21 R-15 R-12 R-30 / R-10 / Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 Occupancy U=0.054 Only * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. WSEC Builder's Field Guide 5th Edition COOPERATIVE EXTENSION WASHINGTON STATE UNIVERSITY rjENERGY PROGRAM u 1-7 a 4g 11 1- �1 bs ‘ ;,r, '—��~ • s fl i~ Oa 1 L e> ret2 FL -00k tSKI Viewd „vephm 7► ° . 1,400a vw j,Lflc UT 1-1-)4 rz_`; UPC 508.2 — Water heaters require anchoring or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS CITY COPY WHEN INTERIOR ALTERATIONS. REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED VNTH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24. & ON EACH FLOOR) EXHAUST FANS 100CFM kitchen 5Q CFM bathrooms & laundry %e+3 C'* TigittoA. Egress windows openable 5.7 sq. ft. - 44" sill EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING ROOMS 1) NET CLEAR OPENING 5 7 SQUARE FEET GRADE FLOOR OPENING (MAX 44') 5 0 SQUARE FEET 2) NET CLEAR OPENING HEIGHT 24 INCHES 3) NET CLEAR OPENING WIDTH 20 INCHES 4) MAX FINISHED SILL HEIGHT 44- ABOVE FLOOR Si I MERGE NCY ESCAPE & RESCUE OPENING SHALL BE OPE RATIONAL F ROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS REVIEWED FOR CODE. COMPLIANCE SPOKANE VALLEY' ^._'ILD DIVISION