Loading...
2008, 07-15 Permit App: 08002638 ResidenceProject Number: 08002638 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Date: 7/15/2008 Page 1 of 3 Permit Use: SFR W/ATT GAR Setbacks: Front Site Information: Plat Key: Left: Right: Rear: Contact: DIAMOND ROCK CONSTRUCTION Address: 2602 N SULLIVAN RD C - S - Z: SPOKANE VALLEY, WA 99216 Phone: (509) 218-4924 Group Name: Project Name: Name: Range District: East Parcel Number: 55202.2312 Block: SiteAddress: 109 S HOLIDAY RD Location:: CSV Lot: Owner: Name: DIAMOND ROCK CONSTRUCTIO Address: 2602 N SULLIVAN RD SPOKANE VALLEY, WA 99216 Zoning: R-3 SF Res District Water District: 134 CONSOLIDATED ID #19 Hold: ❑ Area: 8,037 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information • Review Building Plan Review Released By: .. Driveway/Approach Originally Released: 7/15/2008 By: tmelbourn Released By: NO DRIVEWAY APPROACH REQUIRED Originally Released: 7/15/2008 By: TMELBOU Landuse/Zoning/HE Conditions Released By: - - Sewer Review Originally Released: 7/10/2008 By: mpalaniuk Released By: Permits: r a_ Operator: JD Printed By: jmm Print Date: 7/15/2008 Project Number: 08002638 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 7/15/2008 Page 2 of 3 Building Permit Contractor: DIAMOND BACK Firm: DIAMOND BACK CONSTRUCTIO Address: 2600 E SELTICE WAY #118 Phone: (208) 704-0828 POST FALLS ID 83854 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation 1&2 FAMILY R-3 VB 1,637 $155,498.63 1,637 $155,498.63 BASEMENT U R-3 VB 1,637 $24,555.00 1,637 $24,555.00 COV DECK R-3 VB 25 $375.00 25 $375.00 DECK OPEN R-3 VB 128 $1,920.00 128 $1,920.00 GARAGE U-1 VB 440 $8,360.00 440 $8,360.00 Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Totals: 3,867 $190,708.63 3,867 $190,708.63 Units Unit Desc Fee Amount 1 SELECT $1,503.35 1 SELECT $4.50 1 SELECT $601.34 Permit Total Fees: Mechanical Permit $2,109.19 Contractor: DIAMOND ROCK Firm: DIAMOND ROCK CONSTRUCTIO Address: 2602 N SULLIVAN Phone: (509) 924-8964 SPOKANE VALLEY WA 99216 Item Description DUCT SYSTEMS GAS WATER HEATER GAS APPLIANCE<=100,00013TU GAS PIPING VENTILATING FANS CLOTHES DRYER HOOD -TYPE I1 Units Unit Desc 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 2 # OF UNITS 3 NUMBER OF 1 NUMBER OF 1 NUMBER OF Operator: JD Printed By: jmm Fee Amount $10.00 $10.00 $12.00 $2.00 $30.00 $10.00 $10.00 Permit Total Fees: $84.00 Print Date: 7/15/2008 Project Number: 08002638 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 7/15/2008 Contractor: DIAMOND ROCK Address: 2602 N SULLIVAN SPOKANE VALLEY WA 99216 Item Description TOILETSBIDETS SINKS SHOWERS TUBS DISH WASHERS CLOTHES WASHER MISCELLANEOUS FIXTURES Plumbing Permit Page 3 of 3 Firm: DIAMOND ROCK CONSTRUCTIO Phone: (509) 924-8964 Units Unit Desc 2 NUMBER OF 4 NUMBER OF 1 NUMBER OF 2 NUMBER OF 1 NUMBER OF 1 NUMBER OF 2 NUMBER OF Permit Total Fees: Fee Amount $12.00 $24.00 $6.00 $12.00 $6.00 $6.00 $12.00 $78.00 Notes: Payment Summon,: Permit Type Building Permit Mechanical Permit Plumbing Permit Fee Amount $2,109.19 $84.00 $78.00 Invoice Amount $2,109.19 $84.00 $78.00 $2,271.19 $2,271.19 Amount Paid $0.00 $0.00 $0.00 Amount Owing $2,109.19 $84.00 $78.00 $0.00 $2,271.19 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed 13y: jmm Print Date: 7/15/2008 S`�poka e 4.0000,Valley® For City Use//�YOnly V PLUS ProjectNumber Ill ?ynact Project Address _ irrr.5 4.Oltdl\i 11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206 .- 509.688.0036 509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review. process of your project application, we are providing you with a TARGET DATE for the initial technical application•review. If for any reason we cannot meet this date, we will contact you with a revised target date., . Your application review TARGET DATE is The TARGET DATE is the date we estimate your project application 'will' have had its initial technical review. it is not the date for approval or permit issuance. • Tips for a Smoother Project Application Review . i . Submit complete, accurate plans and documents.. Extra time may be required for re -submittals as project application reviewers [Work on multiple applications and it mqy he several days before they can look at your new or revised information.' . i Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise, for dealing with reviewer comments would be the hest choice for the'entire review process., i Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date, please fee/ free to contact us if .you haven't heard from us by your target date. Staff may contact you before the target date if the Initiarreview is complete. By following this procedure, you will save time'und allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter 'complete. This means all of the required documents, as indicated on your Pre -Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from.requesting additional information as a result of their technical review. • 2. Quality Check. The next step in the process is a quality check -to make sure that the application is reviewable arwl free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue ,until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is'routed to technicafstaff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You -should be contacted by phone. fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re - submittals, each reviewer will approve their section of the application and route it to -the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre -construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE -APPLICANT PINK- BUILDING FILE REV 9/07 Spokane s— Valley Permit Center 11707 E Sprague Ave, Suite 106 Spokane Valley, \VA 99206 (509)688-0036 FAX: (509)688-0037 Community Development wawspokanevallev.ore.com Residential Construction Permit Application A New Construction ❑ Addition/Remodet ❑ Other: =PERMITNUM 1117R:;p car PERMITTEE o Accessory I3kilg ❑ Deck SITE ADDRESS /oi S, do/day ASSESSORS PARCEL NO: LEGAL DESCRIPTION: (o 1 /2 Bi t I Me/111 an "pier 13gilcling;otvnek; = T"4Y Name: D ] 'c ✓ 4 e /kJ i2eir t Cans f , Address: r City: Zip: Phone: Fax: LContactr$erson . Name: 1-20,Ll\ Phone: 21 K- Lig Z.'4 Describe the scope of work in detail: 3,,;ia n k)eL.) SFR eon tQtr w 21- r, Contractor., Name: Ole, wto 1 c9 foci it. CO AS Address: 260z .t/ SU/livei4 City: s'po rl&tne viC Zip: 242-j; Phone: 92 y- b'R 6 Fax: 9 26 ?o 9G/ Lic No: Exp. Date: City Business Lic No: Cost of Project: I$70,,coo **************The following MUST be com tete• i • (wrte N/A The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature GA,ti t .P4711-9- Date Method of Payment: (Faxed permit applications will only be accepted with majorbankcard) ❑ Cash ❑ Check ❑ Mastercard ❑ VISA Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8/25/2005 7/i/o1 0 Other HEIGHT TO PEAK: Z-5DIMENSIONS:5-SXb0t # OF STORIES: 1 TOTAL HABITABLE SPACE: MAIN FLOOR -T TOO SQ. / FTG: i /_ 3'� /r/p 3 / 2Nu FLOOR SQ. FTG: UNFIN BASEMENT SQ. -F7TG: Au) - I �l�J ( IMPERVIOUS FACE AREA: N J n �' FINISHEDBASEMENTGARAGE SQ. FTG: 0 SQ. FTG'JD 7 6y�'7" a EC OV. PAT2 SQ. FTG: / Ai, 23701 --PROPERTY: 30% SLOPES ON 41W-1- # OF BEDROOMS: 3 CONSTRUCTION ION TYPE: SU. - AT •URCE: IcturZxI ec.s S orr.e,Le SEWER OR SEPTIC? Set -t✓ DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature GA,ti t .P4711-9- Date Method of Payment: (Faxed permit applications will only be accepted with majorbankcard) ❑ Cash ❑ Check ❑ Mastercard ❑ VISA Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8/25/2005 7/i/o1 0 Other C� l'euntt Centel Su)okariea 11707 E Sprague Ave, Suite 106 c3 Valley Community Development Mechanical Permit SITE ADDRESS 14 Spokane Valley. WA 99206 (509)688-0036 FAX' (509)688-0037 wwv. spokancralle', mu corn �_„..1VII I}FE `PERMTT..-NLIMBE' Application o Co mer'cial igRe$ide$aiai • Building oivrici-- s{ "^�/ , -..__ _ _ -z' ;_rt1t Name .0;(n VIA°AI ICG t- S U! I VIM ObA 12 / Phone:9zt/ g% ci Fax Ci Zi., --9o91 p City xL,K V/V state Zip C: rn'f, Address Z4,o L- Al,/V ., /, - -1 _ _ .Contracfue r'= - .- �rF,m a �__. _ - ,� _ ,'. - .- -- ,+6 r />Z/6 +!.'A' tr - -. -� -�: ;:x �^, r z- - ti - Name. (O A4 1cr-1- (tel gl'}7't\ I Phone. Fax Address' City State Zip License No. City Business License No. tContact'3z•tr-:,a�-.-1'2#'.ii . f'.,,:_ k�.-, ;t,1,t;�a, a�f=���-r�':< '-�`-," Name' PQ AA `., Phone. ZI4-9I Zy _- .,r.,.. ,.�..,.._.. #OF UNITS X COST 1 FUEL BURNING APPLIANCE Equal to or less than 100,000 X 00 2 3 4 5 6 7 8 9 10 11 FUEL BURNING APPLIANCE UNLISTED APPLIANCE (Additional Fee) UNLISTED APPLIANCE (Additional Fee) USED APPLIANCE (W SEC min. AFUE rating) USED APPLIANCE (W SEC min. AFUE rating) BOILER/REFRIGERATION BOILER/REFRIGERATION BOILER/REFRIGERATION BOILER/REFRIGERATION BOILER/REFRIGERATION 12 GAS LOG, GAS INSERT, GAS FIREPLACE 13 RANGE More than 100,000 515M0 = TOTAL AMOUNT i a- Equal to or less than 400,000 More than 400,000 Equal to or less than 400,000 More than 400,000 1 - 100M BTU X X X X $50.00 $50.00 X 101 -500M BTU X 501 -1,000M BTU $1200 $20.00 1,001 - 1,750M BTU X X 00 More than 1,750M BTU X $1000 $10.00 14 DRYER X 51000 15 FUEL BURNING WATER HEATER X 510 00 I0 16 MISC FUEL BURNING APPLIANCE x $10.00 17 GAS PIPING (each outlet) Z X $1.00 18 DUCT SYSTEMS X $10 00 19 VENTILATING FANS 3 x $10.00 20 AIR HANDLER (DOES NOT include ducting) Equal to or less than 10,000 CFM X $12.00 7- i (.) 3U 21 AIR HANDLER (DOES NOT include ducting) Greater than 10,000 CFM X 515.00 22 EVAPORATIVE COOLERS X $10 00 23 TYPE I HOOD X $50 00 24 25 26 27 28 TYPE II HOOD HEAT PUMP/AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER 29 AIR CONDITIONER 0-3 TON 3-15 TON x X 15-30 TON 30-50 TON X X X More than 50 TON 30 LPG STORAGE TANK 31 WOOD OR PELLET STOVE/INSERT 32 WOOD STOVE - FREE STANDING 33 REPAIR & ADDITIONS 34 VENTILATION SYSTEMS X X X x $1000 $1200 $20.00 $25.00 535.00 560.00 $10.00 $10 00 $25 00 $15.00 /Cl $12,00 35 VENTILATION MECHANICAL EXHAUST X $12.00 36 INCINERATOR - RESIDENCE X $19.00 37 INCINERATOR - COMMERCIAL x 522.00 METHOD OF PAYMENT: ['CASH 0 CHECK 0 VISA 0 MC CARD 4 AUTHORIZED SIGNATURE: DATE EXPIRES SUBTOTAL PROCESSING FEE 535.00 TOTAL PERMIT FEE DUE: REVISED 8/26/05 I'cunit Center �.3g 11707 Il Sprague Ave, Suite 106 Valley Spokane \'alley, \VA 99206 (509)688-0036 FAX (509)688-0037 Community Development www spokanevallcy.mee cum ".;YERMIT'FEE:a Plumbing Permit Application o Commercial Residential ... 1'1?lu(%I1'I'.NLTM13EI SITE ADDRESS /Ass S. Hol(dti�, Ko� Lou nutrng owner. �` =_ _ -, -- - - - t"�o- Name P l Lt 6/10,4 12-0 ( K (V,i( f Phone. H 7 0/- 3 , b'-/ Fax Fax 4Z v ✓ . City $Pct KcV h !f State (111i ami y ZIP �$' Z/,E Address. .. r _ss...e Z X a:a. :`Contractor-:3.'S`z -.,K _ .,_ ....' �., �"r x'S,.' ( t ty 7 1 - Name• (W,K.Q .rV So,is = Phone Fax: TUBS Address: X $6.00 = City State 4 Zip License No: „_�_ ,a„-_,�„ 1 X 56 00 City Business License No 6 5 SINKS ,,_ r _ yo, i=.,t. 'h.. ere., r.:--.'-'"'.r..T..E j4 t ,s,.r-"wa", r- -t 4'"s'`'s,. ° icr":.,.,uTe. ..,.«. ,m ..Ars': 2 9 Name: PG t/., DISHWASHER Phone- 'Z I �'— �/� Z, y $6.00 _... _. . 7 CLOTHES WASHER 1 X X $600 $6.00 AUTHORIZED SIGNATURE: REVISED 8/26/05 DESCRIPTION OF WORK # OF UNITS X COST = TOTAL AMOUNT 1 TOILETS WATER CLOSET, BIDETS Z X 56 00 = / 2 URINALS X $6.00 = 2_ 3 TUBS 'Z X $6.00 = (-Z 4 SHOWERS (PER TRAP) BATH, STALL, ON-SITE BUILT 1 X 56 00 = 6 5 SINKS LAVSBASINS, BAR, FLOOR, KITCHEN, LAUNDRY, UTILITY, JANITOR, PHOTO, X-RAY, FOOD, PREP/CULINARY MEAT Ai X $6 00 2 9 6 DISHWASHER 1 X $6.00 = 7 CLOTHES WASHER 1 X X $600 $6.00 = = ‘, 8 GARBAGE DISPOSAL 9 WATER SOFTENER X $600 = 10 ELECTRIC HOT WATER TANK NOTE: IF GAS, SEE MECHANICAL X $6.00 11 FLOOR DRAINS AREA, CASE, COIL. TRENCH, CONDENSATE X $6.00 12 ROOF DRAINS/OVERFLOW DRAINS X $600 = 13 FOUNTAINS. DRINKING X $600 = 14 WATER PIPING/DRAIN-IN WASTE, VENT. PLUMBING, REVERSAL NSTALLATION, ALTERATION, REPAIR REVERSALS X $600 = 15 SEWAGE EJECTOR GRINDER, SUMP PUMP X 5600 = 16 WATER USING DEVICE ICE AN/OR COFFEE MAKER, HOSE BIB, - STEAMER PROOFER, CARBONATOR SWAMP COOLER Z X 56 00 ^7 ) _ 17 CROSS CONNECTION DEVICE VACUUM BREAKER, CHECK VALVE, AND R P B.P.D. FOR: VATS, TANKS, BOILERS X 5600 = 18 INTERCEPTORS GREASE TRAP, SAND TRAP, CHEMICAL HOLDING TANK X $6 00 = 19 MEDICAL GAS (per outlet) NITROUS, OXYGEN X $600 = 20 MISCELLANEOUS PLUMBING FIXTURE X 56 00 = 21 PRIVATE SEWAGE DISPOSAUSYS X 52000 = 22 INDUSTRIAL WASTE INTERCEPTOR X $15,00 METHOD OF PAYMENT: 0 CASH 0 CHECKPROCESSING DATE: SUBTOTAL ,78 0 VISA 0 MASTERCARD FEE 535.00 EXPIRES: TOTAL PERMIT FEE DUE: AUTHORIZED SIGNATURE: REVISED 8/26/05 PLANNING DCriOVED BY. DATE: ?40/Z0o8 Anil; day Pd 65,00' i3' 6order' is M n i- /0' 65 r-) H -d Scc, I -e '44 5 Lot (Z 5/Kj Mc Allan L's J- es IUa s. ifo i; cf&y (zca. S' Lot. fZ ��i1G1 1V1c.M,l�an l"s fz,te: 0q s. fir) r; (.c.y 2e), W I; day Ed 6s.co' 13' 3ord e r ism i- '0' trk l i i -y WASHINGTON STATE ENERGY CODE TABLE 6-2 PRESCRIPTIVE REQUIREMENT S°'1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Option Glazindg %Area + of Floor Glazin U -Factor s Door U -Factor z Ceiling Vaulted Ceiling' Wall +z Grade Wall. intll Below Grade Wall. ext4 Below Grade Floors Slab s on Grade Vertical Overhead ++ .I. 12% 0.35 0.58 0.20 R-38 R-30 R -2I int7 R-21 R-12 R-30 R-10 II.* 15% 0.35 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 III. 17% 032 0.58 0.20 R-38 R-30 R-19 + R-58 R-21 R -I2 R-30 R-10 IV. 25% Group R-1 and R-2 Occupancies Only 0.35 0.58 0.20 R-38 / U4.031 R-30 / U=0.034 R-21 int7 / U=0.054 R-15 R-12 R-30 / 11=0.029 R-10 / F=0.54 V. Unlimited Group R-3 and R-4 Occupancies Only 0.35 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 VI. Unlimited Group R-3 and R-4 Occupancies Only 0.30 0.58 0.20 R-49 or R-38 Adv R-38 R-21 int' R-21 R-12 R-30 R-10 VII. Unlimited Group R-1 and R-2 Occupancies Only 0.32 0.58 0.20 R-38 / U4.031 R-30 / U=0.034 R-21 int? / U'0.054 R-15 R-12 R-30 / U4.029 R-10 / F=0.54 * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U -factor of U�.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U -factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. 34 Effective July 1, 2007 R602.10.6.2 Alternate braced wall panel adjacent to a door or window opening. Alternate braced wall panels constructed in accordance with one of the following pro- visions are also permitted to replace each 4 feet (1219 mm) of braced wall panel as required by Section R602.10.4 for use adjacent to a window or door opening with a full-length header: 1. In one-story buildings, each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 3/8 -inch -minimum -thickness (10 mm) wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure R602.10.6.2. The wood structural panel sheathing shall extend up over the solid sawn or glued -laminated header and shall be nailed in accordance with Figure R602.10.6.2. Use of a built-up header consisting of at least two 2 x 12s and fastened in accordance with Table R602.3(1) shall be permitted. A spacer, if used, shall be placed on the side of the built-up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full-length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than 6 feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1000 pounds (4448 N) shall fasten the header to the side of the inner studs opposite the sheathing. One anchor bolt not less than 3/einch-diameter (16 mm) and installed in accordance with Section R403.1.6 shall be installed in the center of each sill plate. The studs at each end of the panel shall have a tie -down device fastened to the foundation with an uplift capacity of not less than 4,200 pounds (18 683 N). Where a panel is located on one side of the open- ing, the header shall extend between the inside face of the first full-length stud of the panel and the bear- ing studs at the other end of the opening. A strap with an uplift capacity of not less than 1000 pounds (4448 N) shall fasten the header to the bearing studs. The bearing studs shall also have a tie -down device fastened to the foundation with an uplift capacity of not less than 1000 pounds (4448 N). EXTENT OF HEADER DOUBLE PORTAL FRAME (TWO BRACED WALL PANELS) EXTENT OF HEADER SINGLE PORTAL FRAME (ONE BRACED WALL PANEL) MAX. HEIGHT 10' .1: MIN. 3' X 11.25' NET HEADER 6' TO 18' FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3' O.C. TYP. 1000 LB STRAP OPPOSITE SHEATHING 1000 LB STRAP FASTEN SHEATHING TO HEADER WITH 80 COMMON OR GALVANIZED BOX NAILS IN 3' GRID PATTERN AS SHOWN AND 3' O.C. IN ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. MIN. WIDTH = 16' FOR ONE STORY STRUCTURES MIN. WIDTH = 24' FOR USE IN THE FIRST OF TWO STORY STRUCTURES MIN. 2x4 FRAMING 3/8' MIN. THICKNESS WOOD STRUCTURAL PANEL SHEATHING MIN. DOUBLE 2x4 POST MIN. 4200 LB T1E-DOWN DEVICE (EMBEDDED INTO CONCRETE AND NAILED INTO FRAMING) SEE SECTION R60?.10.6.2 .V3 ,I/ti''^/C N612 c304 -T Fie 0.1R TZ7 i' x eot-TCM cr t=ct,.1ivc`.411 z4 %VALE The tie -down devices shall be an embedded - strap type, installed in accordance with the manu- facturer's recommendations. The panels shall be supported directly on a foundation which is con- tinuous across the entire length of the braced wall line. The foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12 -inch -by -12 -inch (305 mm by 305 mm) continuous footing or turned down slab edge is permitted at door openings in the braced wall line. This continuous footing or turned down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous founda- tion located directly under the braced wall line. 2. In the fust story of two-story buildings, each wall panel shall be braced in accordance with Item 1 above, except that each panel shall have a length of not less than 24 inches (610 mm). TYPICAL PORTAL FRAME CONSTRUCTION FOR A PANEL SPLICE (IF NEEDED), PANEL EDGES SHALL BE BLOCKED, AND OCCUR W111HIN 24' OF MID - HEIGHT. ONE ROW OF TYP. SHEATHING -TO - FRAMING NAILING IS REQUIRED. IF 2X4 BLOCKING IS USED, THE 2X4'S MUST BE NAILED TOGETHER WITH 3 16D SINKERS MIN. 1000 LB TIE DOWN DEVICE r. FIGURE R602.10.6.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING 140 2006 INTERNATIONAL RESIDENTIAL CODE® 16d NAIL AT 12 IN.O.C. 8d NAIL AT 6 IN.0 C. (ALL PANEL EDGES) 16d NAIL AT 121N.O.C. For SI: 1 inch = 25.4 mm. Gypsum board nails deleted for clarity. ORIENTATION OF STUD MAY VARY. SEE FIGURE R602.3(2) GYPSUM WALL BOARD INSTALLED IN / ACCORDANCE WITH CHAPTER 7 8d NAIL AT 121N 0.C. ON ALL FRAMING MEMBERS NOT AT PANEL EDGES (a) OUTSIDE CORNER DETAIL W000 STRUCTURAL PANEL INSTALLED IN ACCORDANCE WITH TABLE R602.3(1) ORIENTATION OF STUD MAY VARY. SEE FIGURE R602.3(2) GYPSUM WALL BOARD INSTALLED IN / ACCORDANCE WITH CHAPTER 7 (INTERIOR) \ WOOD STRUCTURAL PANEL INSTALLED IN ACCORDANCE WITH TABLE R602.3(1) Bd NAIL AT 6 IN.0 CALL FRAMING MEMBERS AT PANEL EDGES AND 12 IN. 0.C. ON ALL FRAMING MEMBERS NOT AT PANEL EDGES (b) INSIDE CORNER DETAIL FIGURE R602.10.5 TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS STRUCTURAL PANEL SHEATHING; SHOWING REQUIRED STUD -TO -STUD NAILING WALL CONSTRUCTION , 1 1 1 FOUNDATIONS TABLE R404.1.1(5) ' CONCRETE FOUNDATION WALLS"' MAXIMUM WALL HEIGHT (feet) MAXIMUM UNBALANCED BACKFILL HEIGHT' (feet) MINIMUM VERTICAL REINFORCEMENT SIZE AND SPACING'•tl•.. " ' Soll classes' and design lateral soli (psf per foot of depth) GW, GP, SW and SP 30 GM, GC. SM, SM -SC and ML 45 SC, ML -CL and inorganic CL 60 Minimum wall thickness (inches) 5.5 7.5 9.5 11.5 5.5 7.5 9.5 11.5 5.5 7.5 9.5 11.5 5 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC PC PC PC PC PC PC PC PC 6 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC PC PCg PC PC #4@35" PCB PC PC 6 PC PC PC PC #5@48" PC PC PC #5@36" PC PC PC 7 4 PC PC PC PC PC PC • PC PC PC PC PC PC 5 PC PC PC PC PC PC PC PC #5@47" PC PC PC 6 PC PC PC PC #5@42" PC PC PC #6@43" #5@48" PCg PC 7 #5@46" PC PC PC #6@42" #5@46"- PCg PC #6@34" #6@48" PC PC 8 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4@38" PCB PC PC #5@43" PC PC PC 6 #4@37" PCB PC PC #5@37" PC PC PC #6@37" #5@43" PCg PC 7 #5@40" PC PC PC #6@37" #5@41" PC PC #6@34" #6@43" PC PC 8 #6@43" #5@47" PCg PC #6@34" #6@43" PC PC #6@27" #6@32" #6@44" PC 9 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4@35" PCB PC PC #5@40" PC PC` PC 6 #4@34" PG PC PC #6@48" PC PC PC #6@36" #5@39" PCg PC 7 #5@36" PC PC PC #6@34" #5@37" PC PC #6@33" #6@38" #5@37" PCs 8 #6@38" #5@41" PCg PC #6@33" #6@38" #5@37" PCs #6@24" #7@39" #6@39"#4@48"" 9 #6@34" #6@46" PC PC #6@26" #7@41" #6@41" PC #6@19" #7@31" #7@41" #6@39" 10 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4@33" PCg PC PC #5@38" PC PC PC 6 #5@48" PCB PC PC #6@45" PC PC PC #6@34" #5@37" PC PC 7 #6@47" PC PC PC #6@34" #6@48" PC PC #6@30" #6@35" #6@48" PCg 8 #6@34" #5@38" PC PC #6@30" #7@47" #6@47" PCg #6@22" #7@35" #7@48"#6@45"h 9 #6@34" #6@417 #4@48" PCB #6@23" #7@37" #7@48" #4@48"1' DR #6@22" #7@37" #7@47" 10 #6@28" #7@45" #6@45" PC DR #7@31" #7@40" #6@38" DR #6@22" #7@30" #7@38" For SI: 1 inch = 25.4 rnm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa: 1 pound per square foot per foot = 0.157 kPa/mm. a. Soil classes are in accordance with the United Soil Classification System. Refer to Table R405.1 b. Unbalanced backfill height is the difference in height of the exterior and interior finish ground levels. Where there is an interior concrete slab, the unbalanced back- fill height shall be measured from the exterior finish ground level to the top of the interior concrete slah c. The size and spacing of vertical reinforcement shown in the table is based on the use of reinforcement with a minimum yield strength of 60,000 psi. Vertical rein- forcement with a minimum yield strength of 40,000 psi or 50,000 psi is permitted, provided the same size bar is used and the spacing shown in the table is reduced by multiplying the spacing by 0.67 or 0.83, respectively. d. Vertical reinforcement, when required, shall be placed nearest the inside face of the wall a distance d from the outside face (soil side) of the wall. The distance d is equal to the wall thickness, t, minus 1.25 inches plus one-half the bar diameter, db (d =t - (1.25 + db/2). The reinforcement shall be placed within a tolerance of ± 3/8 inch where d is less than or equal to 8 inches, or ± 1/2 inch where d is greater than 8 inches. e. In lieu of the reinforcement shown, smaller reinforcing bar sizes and closer spacings resulting in an equivalent cross-sectional area of reinforcement per linear foot of wall are permitted. f. Concrete cover for reinforcement measured from the inside face of the wall shall not be less than 3/4 inch. Concrete cover for reinforcement measured from the out- side face of the wall shall not be less than 11/2 inches for No. 5 bars and smaller, and not less than 2 inches for larger bars. g. The minimum thickness is permitted to be reduced 2 inches, provided the minimum specified compressive strength of concrete J.: , is 4,000 psi. h. A plain concrete wall with a minimum thickness of 11.5 inches is permitted, provided minimum specified compressive strength of concrete, f', is 3,500 psi. i. Concrete shall have a specified compressive strength of not less than 2,500 psi at 28 days, unless a higher strength is required by note g or h. j. "DR" means design is required in accordance with ACI 318 or ACI 332. k. "PC" means plain concrete. I. Where vertical reinforcement is required, horizontal reinforcement shall be provided in accordance with the requirements of Section R404.4.6.2 for ICF founda- tion walls. FOUNDATIONS TABLE R404.1.1(5)—continued CONCRETE FOUNDATION WALLS".4l'k h. A plain concrete wall with a minimum thickness of 11.5 inches is permitted, provided minimum specified compressive strength of concrete, f', is 3,500 psi. i. Concrete shall have a specified compressive strength of not less than 2,500 psi at 28 days, unless a higher strength is required by note g or h. j. "DR" means design is required in accordance with Ni 318 or ACI 332. k. "PC" means plain concrete. 1. Where vertical reinforcement is required, horizontal reinforcement shall be provided in accordance with the requirements of Section R404.4.6.2 for ICF founda- tion walls. R404.4.6.2 Horizontal reinforcement. When vertical reinforcement is required, ICF foundation walls shall have horizontal reinforcement in accordance with this section. ICF foundation walls up to 8 feet (2438 mm) in height shall have a minimum of one continuous No. 4 horizontal reinforcing bar placed at 48 inches (1219 mm) on center with one bar located within 12 inches (305 mm) of the top of the wall story. ICF Foundation walls greater than 8 feet (2438 mm) in height shall have a mini- mum of one continuous No. 4 horizontal reinforcing bar placed at 36 inches (914 mm) on center with one bar located within 12 inches (305 mm) of the top of the wall story. R404.4.6.3 Wall openings. Vertical wall reinforcement required by Section R404.4.2, R404.4.3 or R404.4.4 that is interrupted by wall openings shall have additional ver- tical reinforcement of the same size placed within 12 inches (305 mm) of each side of the opening. 2) 15 rebar o extend 24 nches beyond pening. Reinforcement for openings in plain concrete (2) 15 re beyond op do not re • ar to extend ning. Doorway: uire rebar in in bottom of opening. 1909.63 Openings in walls. Not less than two No. 5 bars shall be provided around window and door openings. Such bars shall extend at least 24 inches (610 mm) beyond the corners of openings. * All openings for windows and doors in structural plain concrete walls must be bound by two No. 5 (16) bars as follows. For openings not extending to the bottom of the wall, the bars must be placed on all four sides of the opening. For openings extending to the bottom of the wall, the bars are only necessary along the sides and top. To provide continuity at the corners of the openings, the bars must extend 24 inches (610 mm) past the corners. These extensions should occur at all four corners of an opening not extending to the bottom of the wall, and at the two top corners for other openings. • WALL CONSTRUCTION R611.7.1.3 Horizontal steel. Concrete walls with a minimum thickness of 4 inches (102 mm) shall have a minimum of one continuous No. 4 horizontal reinforc- ing bar placed at 32 inches (812 mm) on center with one bar within 12 inches (305 mm) of the top of the wall story. Concrete walls 5.5 inches (140 mm) thick or greater shall have a minimum of one continuous No.4 horizontal reinforcing bar placed at 48 inches (1219 mm) on center with one bar located with in 12 inches (305 mm) of the top of the wall story. For townhouses in Seismic Design Category C, the minimum horizontal reinforcement shall be one No. 5 at 24 inches (610 m) on center or one No. 4 at 16 inches (407 mm) on center. For all buildings in Seismic Design Categories Dt and D2, the minimum horizontal rein- forcement shall be one No. 5 at 18 inches (457 mm) on center or one No. 4 at 12 inches (305 mm) on center. Horizontal reinforcement shall be continuous around building corners using corner bars or by bending the bars. In either case, the minimum lap splice shall be 24 inches (610 mm). For townhouses in Seismic Design Category C and for all buildings in Seismic Design Cat- egories D, and D2, each end of all horizontal reinforce- ment shall terminate with a standard hook or lap splice. R611.7.1.4 Lap Splices. Where lap splicing of vertical or horizontal reinforcing steel is necessary, the lap splice shall be in accordance with Figure R611.7.1.4 and a minimum of 40db, where db is the diameter of the smaller bar. The maximum distance between noncontact parallel bars at a lap splice shall not exceed 8db. R611.7.1.5 Standard hook. Where the free end of a re- inforcing bar is required to have a standard hook, the hook shall be a 180 -degree bend plus 4db extension but not less than 2'/2 inches, or a 90 -degree bend plus 12db extension. R611.7.2 Wall openings. Wall openings shall have a mini- mum of 8 inches (203 mm) of depth of concrete for flat and waffle -grid ICF walls and 12 inches (305 mm) for screen -grid walls over the length of the opening. When the depth of concrete above the opening is less than 12 inches for flat or waffle -grid walls, lintels in accordance with Sec- tion R611.73 shall be provided. Reinforcement around openings shall be provided in accordance with Table R611.7(1) and Figure R611.7(2). All reinforcement placed horizontally above or below an opening shall extend a mini- mum of 24 inches (610 mm) beyond the limits of the open- ing. Wall opening reinforcement shall be provided in addition to the reinforcement required by Sections R611.3, R611.4, R611.5 and R611.7.1. The perimeter of all wall openings shall be framed with a minimum 2 -inch by 4 -inch plate, anchored to the wall with'/2-inch (12.7 mm) diameter anchor bolts spaced a maximum of 24 inches (610 mm) on center. The bolts shall be embedded into the concrete a mini- mum of 4 inches (102 mm) and have a minimum of 1'/2 (38 mm) inches of concrete cover to the face of the wall. Exception: The 2 -inch by 4 -inch plate is not required where the wall is formed to provide solid concrete around the perimeter of the opening with a minimum depth of 4 inches (102 mm) for the full thickness of the wall, R611.7.3 Lintels. R611.7.3.1 General requirements. Lintels shall be provided over all openings greater than or equal to 2 feet (610 mm) in width. Lintels for flat ICF walls shall be constructed in accordance with Figure R611.7(3) and Table R611.7(2) or R611.7(3). Lintels for waffle -grid ICF walls shall be constructed in accordance with Fig- ure R611.7(4) or Figure R611.7(5) and Table R611.7(4) or R611.7(5). Lintels for screen -grid ICF walls shall be constructed in accordance with Figure R611.7(6) or Figure R611.7(7). Lintel construction in accordance with Figure R611.7(3) shall be permitted to be used with waffle -grid and screen -grid ICF wall construction. Lintel depths are permitted to be increased by the height of the ICF wall located directly above the opening, pro- vided that the lintel depth spans the entire length of the opening. TABLE R611.7(1) MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLS WALL TYPE AND OPENING WIDTH (L) (feet) MINIMUM HORIZONTAL OPENING REINFORCEMENT MINIMUM VERTICAL OPENING REINFORCEMENT Flat, Waffle-, and Screen -Grid: L< 2 (0.61) None required None required Flat, Waffle-, and Screen -Grid: L >_ 2 (0.61) Provide lintels in accordance with Section R611.7.3. Provide one No. 4 bar within 12 inches (305 mm) from the bottom of the opening. Top and bottom lintel reinforcement shall extend a minimum of 24 inches (610 mm) beyond the limits of the opening. In locations with wind speeds less than or equal to 110 mph (177 km/hr) or in Seismic Design Categories A and B, provide one No. 4 bar for the full height of the wall story within 12 inches (305 mm) of each side of the opening. In locations with wind speeds greater than 110 mph (177 km/hr), townhouses in Seismic Design Category C, or all buildings in Seismic Design Categories D, and D1, provide two No. 4 bars or one No. 5 bar for the full height of the wall story within 12 inches (305 mm) of each side of the opening. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.609 km/h. NOTE: This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equiva- lent rectangular cross section. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. 172 2003 INTERNATIONAL RESIDENTIAL CODE® WALL CONSTRUCTION NO. 4 CONTINUOUS BAR AS REQUIRED IN SECTION R611.7.1 TOP OF WALL STORY L<2'(0.61m) FIG R611.7(4) 611.7(5 FIG R611.7(6) 611.7(7 MIDDLE OF SPAN, A. NOT REQUIRING STIRRUPS SEE TABLE R611.7(2), R611.7(3), R611.7(4), R611.7(5), OR R611.7(8) LINTEL REINFORCEMENT AS REQUIRED A - LINTEL - L 24" 0.6 m >2'(0.61m) 24" m 0.6 WALL REINFORCEMENT AS REQUIRED OPEN REINFORCEMENT AS REQUIRED PER TABLE R611.7(1) FIGURE R611.7(2) REINFORCEMENT OF OPENINGS 1.5 IN. MIN. 2.5 IN. MAX. SEE TABLE R611.7(2). R611.7(3), R611.7(6), R611.7(9) OR R611.7(10) -> For SI: 1 inch = 25.4 mm. NOTE: Section cut through flat wall. 1•I •ui MIN IMINI ■■I ■■i ■■I ■■O ■■I ■■u ■■. ■■I 1.5 IN. MIN. 2.5 IN. MAX NO. 4 BAR LINTEL REINFORCEMENT REQUIRED MINIMUM NO. 3 STIRRUP AS REQUIRED INSULATING FORM HORIZONTAL LINTEL REINFORCEMENT AS REQUIRED FIGURE R611.7(3) ICF LINTELS FOR FLAT AND SCREEN -GRID WALLS 186 2003 INTERNATIONAL RESIDENTIAL CODE® WALL CONSTRUCTION TABLE R611.7(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLS°,b",c,r NO. 4 BOTTOM BAR SIZE MINIMUM LINTEL THICKNESS, T (inches) LINTEL DEPTH, D (inches) MAXIMUM CLEAR SPAN, (feet -inches) (Number is Middle of Span, A)° Supporting Light Framed Supporting Roof Only 2nd Story and Roof Supporting ICF Second Story and Roof Ground Snow Load 3.5 8 30 psf 4-9 (1-2) 70 psf 30 psf 4-2 (0-9) 3-10 (0-8) 12 6-8 5-5 (1-11) (1-3) 16 7-11 (2-9) 5-0 (1-1) 6-5 6-0 (1-9) (1-6) 70 psf 3-4 (0-6 30 psf 3-5 (0-6) 70 psf 3-1 (0-5) 4-5 4-6 4-0 (0-10) j (0-10) (0-8) 5-3 5-4 4-10 11-2) (1-2) (1-0) 20 8-11 (3-5) 7-4 6-9 6-0 6-1 5-6 (2-3) (1-11) (1-6) (1-7) (1-3) 24 9-10 8-1 7.6 6-7 (4-1) (2-9) (2-4) 5.5 8 5-2 (1-10) 12 16 20 8-10 (5-3) (1-10) 6-9 (1-11) 6-1 (1-6) -2 3-10 i1-21 (1-0) 3-5 3-5 3-1 (0-9) . (0-10) (0-8) 5-5 -0 4-5 (2-0) (1-9) (1-4) 4-6 (1-4) 6-5- 6-0 5-3 . . 5-4 (2-9) (2-5) (1-1(1) (1-11) 7-3 6-9 (3-6) 6-0 6-1 5-6 (3 7) (2-4) (2-5) (2-0) 24 9-8 (6-3) 8-0 7-5 (4-3) (3-8) 7.5 8 6-7 (2-11) 6-3 6-0 (3-0) (2-5) 5-2 4-2 3-11 3-5 3-6 (2-6) (1-8) (1-5) (1-1) (1-1) 3-2 (0-11) 12 6-7 5-5 5-0 4-5 (4-0) (2-8) (2-4) 4-6 4-1 (1-1 16 7.9 .. . 6-5 5-11 (5-5) (3-8) (3-3) 0) (1-70) (1-6) 5 3 5-4 (2-6) (2-7) 4-10 (2-2) 20 8-8 (6-10) 24 9.5 8 9-6 (8-2) 7-2 (4-8) 6-8 (4-2) 5-11 (3-3) 6-0 (3-4) (2-9) 7-11 (5-8) - 7-4 (5-1) 5-2 4-2 : 3 1 (3-]) - (2-1) (1-9) 12 16 6-7 - (5-0) 7-8 (6-9) 6-6 (3-11) 6-7 (4-1) 5-5 5-0 4-5 4-6 (3-4) (3-0) (2-4) (2-5) 6-4 5-11 5-3 5-4 (4-7) (9-2) .°`(- .. (3-3):.:v _:..(34) For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kN/m2, 1 pound per square foot = 0.0479 kN/m2. a. This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equivalent rectangular cross section. When reinforcement with a minimum yield strength of 60,000 psi is used, the span lengths in the shaded cells shall be increased by 1.2 times the table values. b. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. c. Deflection criteria: 71240. d. Design load assumptions: Floor dead load is 10 psf Attic live load is 20 psf Floor live load is 30 psf Roof dead load is 15 psf Building width is 32 feet ICF wall dead load is 69 psf Light -framed wall dead load is 10 psf e. No. 3 stirrups are required at d/2 spacing except no stirrups are required for the distance, (A), shown in the middle portion of the span in accordance with Figure R611.7(2) and Section R611.7.3.2. f. Interpolation is permitted between ground snow Toads and between lintel depths. 2003 INTERNATIONAL RESIDENTIAL CODE® 173 WALL CONSTRUCTION TABLE R611.7(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa'boef NO. 5 BOTTOM BAR SIZE MINIMUM LINTEL THICKNESS, T LINTEL DEPTH, D (inches) (inches) 3.5 8 MAXIMUM CLEAR SPAN, (feet -inches) (Number is Middle of Span, A)° Supporting Roof Supporting Light Framed 2nd Story and Roof Supporting ICF Second Story and Roof Ground Snow Load 30 psf 70 psf 30 psf 70 psf 30 psf 70 psf 4-9 (1-2) 4-2 (0-9) 3-11 (0-8) 3-7 (0-6) 3-7 (0-6) 3-5 (0-5) 12 7-2 6-3 (1-3) 5-11 5-5 (0-10) 5-5 (0-10) 5-0 (0-8) 16 9-6 (2-9) 8-0 (1-9) 7-4 (1-6) 6-6 (1-22) 6-7 (1-2) 5-11 (1-0) 20 11-1 (3-5) 9-1 (2-3) 7-5 7-6 (1-6) (1-7) 6-9 (1-3)- 24 5.5 8 5-6 (1-10) 9-3 N 112 4) 4-10 4-7 (1-2) (1-0) 8-2 8-4 (1-10) 1111, 4-2 4-2 (0-9) (0-10) 7-6 1Z t `(1-6) 3-10 (0-8) 12 8-3 (3-0) 16 9-9 (4-1) 6-9 (2-0) 6-3 (1-9) 5-6 (1-4) 8-0 (22-9) (2-5) 5-7 (1-4) 5-0 6-6 6-7 6-0 (1-10) (1-11) (1-7) 20 10-11 9-0 (5-3) (3-6) 24 12-0 9-11 (6-3) (4-3) 7.5 8 6-1 (2-6) 5-2 (1- 12 8-2 (4-0) 6-9 (2-8) 8-4 7-5 (3-1) (2-4) 7-6 (2-5) 9-3 8-2 (3-8) (2-11) 4-9 4-3 (1-5i (1-1i 8-3 (3-0) 1-1) 6-9 (2-0) 7-6 (2-5) 3-10 (0-11) 6-3 (2-4) 5-6 (1-10) 5-7 (1-10) 5-0 (1-6) 16 20 9-7 7-11 (5-5) I (3-8) 7-4 (3-3) 6-6 (2-6) 6-7 6-0 (2-7) (2-2) 10-10 (6-10) 8-11 (4-8) 8-4 (4-2) 7-4 (3-3) 7-6 (3-4) 6-9 (2-9) 24 11-10 9-10 (8-2) (5-8) 9.5 8 6-4 5-2 (3-1) (2-1) 12 8-2 6-8 (5-0). (3-4) 9-2 (5-1) 8-1 (3-11) 8-3 (4-1) 7-5 (3-4) 4-10 4-3 4-4 (1-0) (1-5) (1-5) 6-2 5-6 5-7• (3-0) (2-4) (2-5) 5-0 (1-11) 16 20 9-6 (6-9) 7-11 (4-7) 7-4 6-6 6-7 (4-2) (3-3) (3-4) 5-11 (2-8) 10-8 (8-4) 8-10 (5-10) 8-3 7-4 (5-4) - (4-2) 7-5 (4-3) 6-9 (3-6) 24 11-7 (10-0) 9-9 (6-11) 9-0 8-1 8-2 (6-5) (5-0) (5-2) 7-5 (4-3) For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. 1 pound per square inch = 6.895 kN/m , 1 pound per square foot = 0.0479 kN/m'. a. This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equivalent rectangular cross section. When reinforcement with a minimum yield strength of 60,000 psi is used the span lengths in the shaded cells shall be increased by 1.2 times the table values. b. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. c. Deflection criterion: !/240. d. Design load assumptions: Floor dead load is 10 psf Attic live load is 20 psf Floor live load is 30 psf Roof dead load is 15 psf Building width is 32 feet ICF wall dead load is 69 psf Light -framed wall dead load is 10 psf e. No. 3 stirrups are required at 62 spacing except no stirrups are required for the distance. (A). shown in the middle portion of the span in accordance with Figure R611.7(2) and Section R611.7.3.2. f. Interpolation is permitted between ground snow loads and between lintel depths. 174 2003 INTERNATIONAL RESIDENTIAL CODE® WALL CONSTRUCTION TABLE R611.7(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS WITHOUT STIRRUPS IN LOAD-BEARING WALLS0',"°. t. o. h (NO 4 OR NO.5) BOTTOM BAR SIZE For SI: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 pound per square foot = 0.0479 kPa; 1 pound per square inch = 6.895 kPa. a. Table values are based on tensile reinforcement with a minimum yield strength of 40,000 psi (276 MPa), concrete with a minimum specified compressive strength of 2,500 psi, and a building width (clear span) of 32 feet. b. Spans located in shaded cells shall be permitted to be multiplied by 1.05 when concrete with a minimum compressive strength of 3,000 psi is used or by 1.1 when concrete with a minimum compressive strength of 4,000 psi is used. c. Deflection criterion is L/240, where L is the clear span of the lintel in inches. d_ Linear interpolation shall be permitted between ground snow loads and between lintel depths. e. Lintel depth, D, shall be permitted to include the available height of ICF wall located directly above the lintel, provided that the increased lintel depth spans the entire length of the opening. f. Spans shall be permitted to be multiplied by 1.05 for a building width (clear span) of 28 feet. g. Spans shall be permitted to be multiplied by 1.1 for a building width (clear span) of 24 feet or less. h. ICF wall dead load is 69 psf. 206 2006 INTERNATIONAL RESIDENTIAL CODE® MAXIMUM CLEAR SPAN (feet -Inches) Supporting Roof Only Supporting Light -Framed Second Story and Roof Supporting ICF Second Story and Roof MINIMUM LINTEL MINIMUM UNTEL MAXIMUM GROUND SNOW LOAD (psi) THICKNESS, T (Inches) DEPTH, D (inches) 30 70 30 70 30 70 Flat ICF Lintel 8 2-6 2-6 2-6 2-4 2-5 2-2 12 4-2 4-2 4-1 3-10 3-10 3-7 3.5 16 4-11 4-8 4-6 4-2 4-2 3-11 20 6-3 5-3 4-11 4-6 4-6 4-3 24 7-7 6-4 6-0 5-6 5-6 5-2 8 2-10 2-6 2-6 2-5 2-6 2-2 12 4-8 4-4 4-3 3-11 3-10 3-7 5.5 16 6-5 5-1 4-8 4-2 4-3 3-11 20 8-2 6-6 6-0 5-4 5-5 5-0 24 9-8 7-11 7-4 6-6 6-7 6-1 8 3-6 2-8 2-7 2-5 2-5 2-2 12 5-9 4-5 4-4 4-0 3-10 3-7 7.5 16 7-9 6-1 5-7 4-10 4-11 4-5 20 8-8 7-2 6-8 5-11 6-0 5-5 24 9-6 7-11 7-4 6-6 6-7 6-0 8 4-2 3-1 2-9 2-5 2-5 2-2 12 6-7 5-1 4-7 3-11 4-0 3-7 9.5 16 7-10 6-4 5-11 5-3 5-4 4-10 20 8-7 7-2 6-8 5-11 6-0 5-5 24 9-4 7-10 7-3 6-6 6-7 6-0 Waffle -Grid ICF Lintel 8 2-6 2-6 2-6 2-4 2-4 2-2 12 4-2 4-2 4-1 3-8 3-9 3-7 6 or 8 16 5-9 5-8 5-7 5-1 5-2 4-8 20 7-6 7-4 6-9 6-0 6-3 5-7 24 9-2 8-1 7-6 6-7 6-10 6-2 For SI: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 pound per square foot = 0.0479 kPa; 1 pound per square inch = 6.895 kPa. a. Table values are based on tensile reinforcement with a minimum yield strength of 40,000 psi (276 MPa), concrete with a minimum specified compressive strength of 2,500 psi, and a building width (clear span) of 32 feet. b. Spans located in shaded cells shall be permitted to be multiplied by 1.05 when concrete with a minimum compressive strength of 3,000 psi is used or by 1.1 when concrete with a minimum compressive strength of 4,000 psi is used. c. Deflection criterion is L/240, where L is the clear span of the lintel in inches. d_ Linear interpolation shall be permitted between ground snow loads and between lintel depths. e. Lintel depth, D, shall be permitted to include the available height of ICF wall located directly above the lintel, provided that the increased lintel depth spans the entire length of the opening. f. Spans shall be permitted to be multiplied by 1.05 for a building width (clear span) of 28 feet. g. Spans shall be permitted to be multiplied by 1.1 for a building width (clear span) of 24 feet or less. h. ICF wall dead load is 69 psf. 206 2006 INTERNATIONAL RESIDENTIAL CODE® City of SPOKANE VALLEY BUILDING DEPARTMENT 11707 E. Sprauge Avenue, #106, Spokane Valley, Washington 99206 - Tel 509-921-1000 - Fax 509-921-1008 1-1/4" to 2" maximum Nosing of crea. 34"-38" 6' 8" minimum Handrail Return ends to wall, or terminate at newell post 34" — 38" Triangular arca formed by tread, riser and guardrail so that 6 inr sphere can not pass through Intermediate rail spacing or pattern so that 4 -inch sphere cannot pass through REQUIRED WIDTH OFRUNSHALL BE PROVIDED INTHISLOCATION (SECTION 1003 2.3.82) �1 '� NOTE HANDRAILS NOT ���1-�3 sHown FOR r1.WTY STAIRWAYWIDTH 6 c,S O; LIMITATION:APPLIES TO Ra OCCUPANCY (SECTION 1003.33.82) LS4, AND PRIVATE STAIRVAYS IN R -I OCCUPANCY PLAN VIEW PLAN VIEW WINDING STAIRWAY ALTERNATE USE OF WINDERS REQUIRED WIDTH OF RUNSHALL HE PROVIDED INTHIS LOCATION ECTION 1003.3.3.A.1) NOTE HANDRAILS NOT SHOWN FOR CLARnY LuJcwuu P'2-wp/ RISE BETWEEN TREADS PLAN VIEW CIRCULAR STAIRWAY WALL IMITATIONS: I. ONLY APPLIES TO R.3 OCCUPANCY 0.140 PRIVATE STAIRWAYS IN R -t OCCUPANCIES. 2 LIMITED TO SERVING A5 EXIT FOR 400 SOUARE FEET MAXIMUM. PLAN VIEW SPIRAL STAIRWAY Stair Dimensions 1 1 1 1 Width (36' minimum) Rise (4" minimum -,8"s if Run Vir minimum) The greatest riser height within any flight of stairs shall not exceed the samllest by more than 3/8". Stair treads shall be of uniform sizc and shape, except the largest tread run within any flight of stairs shall not cxcccd the smallest 1 Wb more than 3/8 inch. Dc�INFa —T.4 /,} ?c ass t'4v 1 Onaerath regquired (two required if stair is open on sides) if there arc four or more risers. 1 Height (34" to 38' above nosing of treads). 1 Projection (1-1/2 between handrail and wall). 1 Handrails shall be continuous the full length of the stairs. Ends shall be returned or shall terminate in newel posts or safety terminals. Guardrails 1 Required if 30' or more above grade. 1 Height (36' high at landings - handrail height at stops). 1 Openings (small enough that a 4" diameter sphere can not pass through). ACCEPTABLE SHAPES AND INSTALLATIONS --HANDRAIL t-lle TOS 1rJusm;n ..ftl.ii?r„C�HIt WALL NOT ACCEPTABLE THE HANDRAIL DETAIL SHOWN HERE DOES NOT COMPLY WR13 THE tONTWUDUS- TERMINOLOGY IN THE CODE HANDRAIL CONTINUITY j1 NOTACCEPTABLE NOT ACCEPTABLE ole that while every effort is made to assure the accruacy of the information con ained in this brochure it is not warranted For accuracy. ument is not intended to address all aspects or regulatory requirements for a project and should serve as a starting point for your investiga- • detailed information on a particular project, permit, or code requirement refer directly to applicable file and/or code/regulalory documents or he appropriate division or staff. {L PCLIA S 5-/-tc 14-4' (4 L,/ 5 ('-r 1,.l, pyt�T4piP aS ii 14� Y� "Me} a fir•. I7"lu ..` r 1f 'MY remarimamne taS"•J"'awaramr3S"'3 als MIA9V IDV1890P'"tri 11211N4i1RWIMIR`aA7lRlbf C441•1 ^a3xratl.RU414X4Qiw GIVIIE laHlanr• .i a t,4,�iUs ` •.? 14iZ%:af _,laf :.CJ, Stix '�.I�:.�. �j:2h 4 vdr v'1 PAMIIIPk4it17014441 Jt£!k@'f }SIAM) ILMN 4aS1{S5ICASY7H17pmmt llM4 R a st:a ortreili 4 ptiktI iVMAININ6ffVMitilntr:Vtl.6Y+f7G1 t'b nrn1f00LINia11ltti.SA"7SPR'QRS'IJFWV&99Mty,A� t }� « { rind s, M7R71XS7J.,.@91W916'I1 ff.. RyH�1Y'ARl'F.:DAOq i'..R'A9A,..,,„..,610A.M.,.7A.,,,. 'gcP'iWWW.. G774IIMPRIII AVAt ritIMlq y 1411gyN CA PAittftitt t faiMAIMAtti 6@t149 MIREtrtirr fi'69P74•n4�NiFTaHS lLLNafdBRitXtWiINYa'WYk1Y4f03Q6.1'>pPt ri. Fr1RWHRW{WWBc'A 7F g 9AAAPSMxk7fMN'.I�M191rtdCUA1YR51otAM'IF191W RT1C11AV1TJ9rHYVfi7R1Hl�aR]p111Yu"5R7'7A7ANM7,4J1'A4YN5'„L IBIENRI 7g11HER M17tNa'i7A(w7IIMO R, NAY91AANt0 4,L 10:141191V®2M7 MTENE 1111 l 'IM� ‘4,:t1A, 7r Y tI , f' 40,91? dR ori d N bt$�5iare1F.t6�'S 1:: yr n 1�S clFiki anc1 warty rra?.lSarwIxnreantl411ATA klA/i�gt}1oµ mo LY y 't1Yp�r,fy ' Y+R . 6$g cc '+, 1 AV Or;' rr�r, �1 cY, au 1f'"Ck 1n.: ) , / \,t 2'\ , ! y a ; . ƒ { ) w/, & PROVIDE SOLID BLOCKING UNDER ALL COLUMNS BEARING WALLS AND SHEAR -WALLS. PROVIDE DOUBLE JOINTS BM UNDER ALL WALLS PARALLEL TO WM UJiA. PRCNIDE DOUBLE STUDS_ NMA TO FOUNDATION UNDER ALL HIP ANO GIRDER TRUSSES U.N.O. PROVIDE SHEAR CONNECTION FROM INTERIOR SHEAR WALLS TO TRUSSES OR JOISTS ABOVE. EMERGENCY FROM x111PMNROOMS 1) NET CLEAR OPENIII 5.7 SQUARE FEET GRADE FLOOR OPENING FMK 4i') 5.0 SQUARE FEET 2) NET CLEAR OPENING HEIGHT 24 INCHES 3) NET CLEAR OPENING WIDTH 20 MICHES 4) MAX FINISIiED SIL1. IIT 44• MOVE FLOOR 51 E ME RGE NC Y ESCAPE iMEIGUE OPENING SHALL BE OPERATIONAL FROM THE IIINE Of TME ROOM *MOUT THE IJSE OF KEYS OR TOOLS :.- SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS. AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24. & ON EACH FLOOR) EXHAUST FANS 100, M. kitthn 50 CFM bath -moms & latthdry Vail -1r° -rb 1t7T �C I o fL Washington State Ventilation and Indoor Air Quality Code requires a source specific and whole house ventilation system Minimum depth for frost protection in the City of Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. Radon Mitigation System required with 6 mil Vapo_ Ear -i -r WINDOW WELL: Min. 9 sq. ft. horizontal area. Min. 3 ft. horizontal projection and width. Max. 44 in. vertical depth without a ladder Concrete lintels shall conform to Tables R6113 (2) or (3) or Engineering is required. Reinforcement for openings in plain concrete is also required. CONCRETE TO COMPLY TO IRC TABLE 404.1.1(1:) FOUNDATION. WALLS - 3000 # PSI SLABS, GARAGES, CARPORTS & PORCHES - 3500 # PSI ALL FOOTINGS MUST BE CONTINUOUS 18'-0" 44' 0" 11' 1" 10' 7" 4040SL egress 4040SL egress 5'0" J 1 4040SL egress 2'6" • fo L J LIVING AREA 1639 sq ft 2'6 10' 5" 4040SL egress 4'0. 2-2x10 beam 2'6" 9' 11" totA•b wsrr 41" Rtrt'pu t 26th 2'6" ® FwNt v AAt A Bq 0 2-2x10 beam 1 k �J 2'4" 0 9' 2" 2'6" 9.9. 18' 8" Minimum 24' x 7-96" x 10" thickened concrete pad w/o continuous footing for Girder Truss or Glulam Beam above GARAGE 19'-D" x 21'-6" LU U 44' 0" UPC 508.2 — Water heaters require anchoring or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. O Ana tc7of fr 20' 0" \ 3' 0" -4'-9"- O CO ax./6 OCsc < -1 TY GLASS - m 44' 0" 6' 0" l'-3" --2-0 2'-9" -.,----- 4'-6" 15' 4" 6' 0" • • \ 3036SH Goz,la. 3 Meted 3 4 'Y(' c 4 XYZ. 10 Ey-es Gc2Z•!c2.--- \ 6' " sliding glass door • T. 4'10" \ 2030SH df^ • 2'4' • 6050SL egress / / / \ eGoz. /U, j "- s d5 2'6" 3'-2" 11'-2" y\a0f\L 4-10 S 4040SL egress 4-10" 4'0" 4040SL egress / / / / / / / / / 7 6" / / / / / 8050 Living Area 1639 sq ft - 18'-8" J n ih ..rricr MIMES* �_^ NG - �,• VE: :sieR ONE HOURRN sfigielpotn w^ ❑ 0 SQUARE FEET 5$1" ' 'fl ® : :LESPBQ OR ❑ 1/BP rifrreom i nc. FLOCZO/ROPINI 3'-2" - GYPSUM BOARD USED FOR INTERIOR BRACED WALL CONSTRUCTION SHALL,BE FASTENED NO FURTHER THAN 7" O.G. EQUIP a Y1' i STEEOCOORBOAR DOORSif USE OF f vS ORI GARAGE 19'-0" x 21'-6" L LIVING AREA SAtlGsg4t- 44' 0" 16' 0" 20' 0" '0'» LANDING required on both sides or exit doors with mm. size or 3 ft. measured in direction of travel by 3 ft. or width of door if greater, and not lower than 1 1/2 in. below threshold. Landing required at other exterior doors is a minimum size of 3 ft travel distance by width of door, and not lower than 7 3A in. below threshold provided the door does not swing over the landing. 7- 7'1 1 Lix4-1 (4- ,° epeloCo. elh i..2x to ' i w, • �•� �. 1 • - ;)( lo Led3e r 4-4-4.4.t G e.-- -fo leo G454, V /x '10611.1~5 0I �4%, e t,i• c . DECKS: Ledger board requires %2" lag bolt @ 16" o.c_ with flashing behind. Guardrail 36 in. high required if floor more than 30 in. above grade. Picket spacing no more than 4 in. apart. Posts require approved base and beam connectors. Min. 24 M. frost protection to finish erade with min 19 in fent;,,,, 02X 10 3"Qis+5@ It" o.C. Flo JSe. h �W N1101.3.1 — Attic insulation certification required as to R — value or coverage. Markers, attached to trusses or rafters, required for every 300 sf of attic space with 1 inch high numbers for installed thickness of insulation. felt for ice dam protection `rD 2�`IM-tofr €' K1 I R10 it um 04:aidbesard baffles 60 *felt R602.13.5 continuous brace mail 7116" OSB Shing 8" HP lap siding 'Douse wrap under J vapor trannear 1 sq. Li 300 sq. ft. attic ventilate 15#felt Engineered Trusses 24` D.C. 30 Year comp roofing R-38 Blown iim insult WIC OSB Sheathing 1/8" GAP RE WEEN SHEATHING 1142"" drywall' slime away from Round) Sr drywall 2x4 16" O.C. Int. Walls 6"x t 6" found.lwall mai—Treated ph Anchor Bolts- Min. %i" x 9" with 7" concrete embedment at 6' o.c. and 12" from ends of sill plates. 6" x 144" 100firng 2x111110" O.C. passiveranion system Damn -Proofing required on foundation walls from top of footing to finished grade of crawl space or basement Ext 16" 0.C. R-21 Batt i saul4 3/4" 06B Sheathing 2x4 16" 0.C. Draped insunl. 6 mull vapor barrier 111" drywall mill. fie taped Maim door Garage 4" cam Ibor slope toward door (A/4 n, red 711 Se/a1171- 711 Driveway Approach Deviations, relocations or alter- ations to existing or designated driveway approaches in subdivisions will require a right of way permit address- ing storm water engineered configuration and sizing. PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS STolume REVIEWED FOR CODE ' OM • LANCE SPOKANE VALLEY aU;t'iN IVISION -7-71A- 7 oK