Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2013, 09-05 Energy Compliance Certificate
% 4 "v u J % st V 5, 3 .. Property Conditioned Builder or Viking Address: 116 S Hodges Spokane Valley, WA Floor Area 1160 Date 09 / 05/ 2013 registered design professional : Construction Home Energy Audit Tech Signature: Ceiling: Walls: Above Below, Below, NFRC rating Default rating 41eQBtown 509 280 0381 R-Values Vaulted R- Floors Over unconditioned space R- Attic R- 38 Slab on grade floor R- 10 grade R- 21 Doors Metal R- 5.3 int. R- Glazed R- 3.3 ext. R- R- 1I-Factors and SHGC (or) Windows U- .30 SHGC- .32 (Chapter 10 WSEC 2009) Skylights U- SHGC- v Chapter 9 Option(s) 6 or 1a Total Chpt. 9 Credits 1 Heating, Cooling & Domestic Hot Water .l % System Type Efficiency Heating Gas forced air 92.470 Cooling Electric central 13 seer ;; DHW Gas 50 gal .58 EF ON t-v All ducts Test Method: Test Target Building System type: Duct & Building Air Leakage & HVAC in conditioned space (/ no) Insulation X Total leakage Leakage to exterior X Air handler 70 CFM@25Pa Test Result 47 R- 8 present CFM@25Pa 10 0 b 2 -I c.� air leakage target: SLA<0.00030 - Tested leakage: SLA= Onsite Renewable Energy Electric Power System Rated annual generation Kwh Part 1 Contractor Viking Job# 3545 116 S Hodges Rd LOOSE- FILL INSULATION CERTIFICATE Weatherization Division IEEL Form No. 8403 Part 2 Ceiling areas Insulated with fiberglass or loose fill Eagle Insulation Inc. Reg# RCE 2647 11017 N Government Way Hayden, ID 83835 208-762-1189 Square Added Number LBS Per Total Insulation Manufactures Feet R -Value of bags Bag Depth Type Name 0 38 0 25 10.3" Cellulose Thermoguard 64 49 Fiberglass Knauff 0 Foam Brd R Max 0 19 0 25 5.15" Cellulose Thermoguard 1110 49 71 25 13.3" Cellulose Thermoguard 0 60 0 25 16.1" Cellulose Thermoguard Part 3 Wall areas insuklated with fiberglass or loose fill Square Added Number LBS Per Total Insulation Manufactures Feet R -Value of bags Bag Depth Type Name 8 2" Fiberglass Knauff 60 11 3" Fiberglass Knauff 0 13 3.5" Fiberglass Knauff 0 15 3.5" Fiberglass Knauff 0 19 6.5" Fiberglass Knauff 911 21 5.5" Fiberglass Knauff 0 13 0 25 3.5" Cellulose Thermoguard 0 21 0 25 5.5" Cellulose Thermoguard Part 4 Floor or rim joist areas insulated with fiberglass or loose fill Square Added Number LBS Per Total Insulation Manufactures Feet R -Value of bags Bag Depth Type Name 0 11 3.5" Fiberglass Knauff 0 13 3.5" Fiberglass Knauff 0 15 3.5" Fiberglass Knauff 0 19 6.5" Fiberglass Knauff 0 21 5.5" Fiberglass Knauff 0 25 8" Fiberglass Knauff 0 30 9" Fiberglass Knauff 0 38 12" Fiberglass Knauff 0 30 0 25 10" Cellulose Thermoguard Part 5 Foundatio walls insulated with fiberglass or loose fill Square Added Number LBS Per Total Insulation Manufactures Feet R -Value of bags Bag Depth Type Name O 8 2" Fiberglass Knauff O 11 3.5" Fiberglass Knauff O 19 6.5" Fiberglass Knauff Part 6 SQ FT 0 Installed 6 mil vapor barrier in crawler Yes 1 Meets Washington State work Compliance Sheet SQ FT 1424 Installed poly vapor barrier on all exterior warm side walls SQ FT 0 Insulated water pipes R-8 SQ FT 400 Insulated heater plenum and hard ducts with R-8 insulation 40" Baffles 0 Installed cardboard or foam vents at trus heals 60" Baffles 44 Installed cardboard or foam vents at trus heals Foam Vents 0 Installed cardboard or foam vents at trus heals Eagle Insulation Inc. certifies that the above residence identifies in part 1 was insulated, inspected by local Building Depts. As specified in part 2,3,4,5 and 6 and the installation was conducted in performance to applicable codes, standards and regulations at time of Installation Authorized Signature Date Installed: 8/9/13 Energy Code S u p p a 1 t WASHINGTON STATE UNIVERSITY EXTENSION ENERGY PROGRAM Duct Leakage Affidavit (New Construction) Permit #: / AIHouse address or lot number: 11II A (o S D Zip: City: ST n Lun,l., ail( t z. Cond. Floor Area (ft): 1 1 (o 0 Source (circle one): Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handier in conditioned space? Udeas..latto Circle Test Method: Leakage to Outside Air Handier present during test?''yes " Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) = CFM©25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .04) = Li% CFM©25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM@25 Pa Test Result: 1/11 CFM©25Pa Ring (circle one if applicable): Open 1 Duct Tester Location: Lt till 2M. tit MA Pressure Tap Location: L Y v v 1 P, IAA_S IAN il I certify that these duct leakage rates are accurate and determined using standard duct testing protocol. 3 l OA Company Name: 14 0 t4tiUr Technician Signature: Date: 1 J ,./3 I n '3 Phone Number: S4)9 2 8 63 t' Technician: L l,/ ` e r b k✓ IA,