1977, 04-28 Permit App: M1326 ResidenceCity of Spokane. Washgton
BUILDING CODES DEPARTMENT, N. 811 JEFFERSON, SPOKANE, WASHINGTON 99201
• APPLICATION FOR LAND USE OR STRUCTURE PERMIT . 6
GENERAL REQUIREMENTS PERMIT FEE
PERMIT REQUIRED. A land use or structure permit is required by County Resolution to erect a building or structure of any
kind or alter any building or structure already erected, or to change a land use. Construction most conform with the
Spokane County Building Code and Zoning Ordinance. Construction is subject to inspection.•
WATER. Water supply must be approved by the County and State Health Departments. Where work on water connections disturbs
the surface, shoulders or ditches of County Roads, permission must be obtained from the County Engineer's Office.
SEWAGE SYSTEM. Permits are required in all cases by County Resolutions Nos. 45-133 and 47.235.
SET -BACK FROM PROPERTY LINES. In most zones and under most circumstances, a set -back from the front property line, of at'
least 25' is required, a 5' side yard, 15' side yard from a flanking street, and a 25' rear yard are required.
STATE HIGHWAYS. Where the structure abuts a State Highway, clearance must be obtained pertaining to set -back and ingress
and egress.
COUNTY ROADS. Work on street right-of-way may not be performed until staked by County Road Department and work must be
performed in accordance with stakes. Points of ingress and egress must be approved by the County Engineer. _
MOVING OF BUILDINGS. A permit is required to move an existing building. When a building is moved on a County or State
Highway, clearance must be obtained from the County Engineer and/or State Highway Department.
ACCESSORY BUILDINGS. Accessory buildings (garages, sheds, etc.) require a separate permit.
RESTRICTIVE COVENANTS. Builders should check provisions of covenants or dedications and easements running with the land
which are enforceable through civil action. County Officials can not bring action to enforce covenants or dedications.
APPLICANT FILL IN BELOW THIS LINE jx,, ,t yf,Lq y,2/h
Name of Owner (lee; L F. "Art S in Address l 1Q -2-/r k/c/�PS /Pty Phone f 7f " � Y6 -6l
Architect a S at41-P_ Address '' Phone
Engineer � yy Sa win( C y- Address ' �i /1 Phone +' _
Contractor 1�+r �.rn.NKr SK .11 G (1.N%td_2i' Address a /-i/•�-�s. ' �%l/n17ff,A2p�/ Phone 9� J*'
Legal Desc iption of Property (Give complete description from deed, tax receipt etc ) A'q-pV a rc 2. /904
t.0+ a t&lock 2 Vallty \//eo I -471s 6 add ;ten
DESCRIPTION OF WORK: New 'I/ Addition Remodel Moving Bldg. Zone / Fire Zone -5
Size of Lot g77:511..1 ' X 14/.../.. (Y 1 X 70 ' X. /S9, 4 f - Sewage System Sepphil'. Tine Const. FRAM C
wa.c , t b' /4' PSc/( /7e41- IFr., Conc., Br., etc.)
Stories Dimensions 24 X 42 i el. .1010JX (0 Osr. it) Total Sq. Ft I1 -2a7 Valuation eyC• ddc,.
Rooms _it_ Bathsa Basement rut 1 Foundation Const PCNC✓CTQ Chimney p!LOE Fireplace . pve' 'CIS
(Full, part, none) (Kind) (Number
Heat. System fOre.A,1 l=/eet Type of Roofing C.vmploa./Len •Ext Finish T11 flYiew,ai Int. Wall Finish =skeet' rock -
Use of Bldg.
.&i. rrook-
UseofBldg. rrS tcie4Cc — 5i111r -fa07;Iy '-dm-rhezi vara c/e No of Units_ Bedrooms ?
4 t
c c/ r,e.--et?r,.0t-4
PLOT PLAN
Draw sketch with dimensions showing: (1) property lines; (2) street or road locations; (3) location of existing and
proposed buildings; (4) distance to property lines and streets; (5) dimensions of buildings; (6) location of sewage sys-
tem and water supply lines.
- COMMERCIAL
SOU T
I hereby certify in orotation s ittJd is correct and there are no other structures located on this property except
as shown. / /
REQUIRED
Plumbing Permit
Heating Permit
Sewage Permit
Plans Received
Plans Checked
Plans Returned
Plans Picked Up
Plans Mailed
Owner or -Ag
A LAND USE OR STRUCTURE PERMIT MUST BE ON THE PREMISES BEFORE CONSTRUCTION COMMENCES.
THIS IS NOT .4 PERMIT.
41- C= Cr- 7
Date --
DO NOT WRITE BELOW THIS LINE
Your street address will be /94 it
�.O SGC -P JYy. The zone is JA.4.4� C2,.�/-4I 1> d—
Sewage Permit Number Issued Building Permit 3 a -L Receipt/%+' ii Issued
Remarks
Form 523 Bldg. Code