Loading...
2006, 06-30 Permit App: 06002373 Pole BldgProject Number: 06002373 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 6/30/2006 Page 1 of 2 Project Information: Permit Use: 30 x 30 POLE BUILDING Setbacks: Front Left: Right: Rear: Site Information: �..:., ,. Plat Key: Name: Range MORMIENONSOMNIMPV Contact: Address: C - S - Z: Phone: Group Name: Project Name: GISOLO, MARTIN R 1423 N LILY RD SPOKANE VALLEY, WA 99206 (509) 328-4431 District: Nort Parcel Number: 35131.0305 SiteAddress: 1423 N LILY RD Location:: CSV Zoning: UR -3.5 Water District: Area: 12,344 Sq Ft Block: Urban Residential 3.5 Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Lot: Owner: Name: GISOLO, MARTIN R Address: 1423 N LILY RD SPOKANE VALLEY, WA 99206 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Released By: Originally Released: 6/21/2006 By: TMELBOU Landuse/Zoning/HE Conditions Released Y: Sewer Review Permits: Originally Released: 6/20/2006 By: KKENDAL Released By: PER LANCE, PROPERTY HOOKED TO SEWER 6/24/06 Originally Released: 6/30/2006 By: amblake Operator: AMB Printed By: AMB Print Date: 6/30/2006 Project Number: 06002373 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 6/30/2006 Page 2 of 2 Contractor: OWNER Building Permit Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation POLE BDLG U-1 VB 864 $16,416.00 864 $16,416.00 Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBC SURCHARGE Notes: Payment Summary: Permit Type Building Permit Totals: 864 $16,416.00 864 $16,416.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Fee Amount $279.25 $69.81 $4.50 $353.56 Fee Amount Invoice Amount Amount Paid Amount Owing $353.56 $353.56 $0.00 $353.56 $353.56 $353.56 $0.00 $353.56 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 6/30/2006 cubing • Pipe • Kebar • Plate & Sheet Structural Shapes • Processing Services 925 North Oregon Ave. • P.O. Box 3035 • Pasco, WA 99302-3035 LOCAL WA, OR & ID FAX 545-0688 1-800-237-1742 (509) 545-0697 www.pacific-stee Steel 06/21/2006 13:15 509324156f �"1J1, 21 2006 11:06 FR Vproject Num NT: 06002373 Penalties ProjectJ'a rmation : ®, Palnit Use :10 x 30 POLE B Setbacks: Front Lef Inv: 1 JKr113 CMJ Application THIS_,IS_NOT A PERMIT nencing work without a permit Contact•. GISOLO, MARTIN R Address: 1423 N LILY RD WA 99206 C - S - Z: SPOKANE VALLEY, Phone; (509) 328-4431 Group Name: Project Name: TO 324156? Date: 6/19/2006 P.01'03 -- Page 1 of ;z Shea MSI!Jx: P)Iar R e r Name: o panel Number. 35131.030 :iteAddroas: 1423 N LILY RD 171/0( Block: Location:: CSV Zoning: UR -3.5 Urban Residential 3.5 Water District Area: 12,344 Sq Ft Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Sake le&m„ motion: Bu 11 ding Plan Review District: Nort Lot: Owner: Name: GISOLO, MARTIN R . Address: 1423 N LILY RD SPOKANE VALLEY, WA 99206 Hold: 0 Depth: 0 Right Of Way (ft): 0 Cantrai:Gn: OWNER kV)51-QC&ItIP Op:tator. AMB JUN 21 2006 14:35 Printed By: AMB Building Permit Finn: OWNER Phone: (000) 000-0000 Print Date: 6/19/2006 5093241567 PAGE.02 06/21/2006 113:15 5093241567 t<111.) tn5 •A!'BiLeetO.ur aI apse"i...i.. . ri.' . Ate1#44i i6ii4'o'.ded. eli�`A Stiw $d1R iiiUCh,4X0p i;L14itft *AI*: - .. 1.��''' I �—•-e�Ci'�Y'���'�•a9�-«�-»:.i...�..._+-i,.:\...:r..:.: i..... I a.«.....J.w.ih. �.:w.....:.. ...r � ..Ll) .Death iii p v erty urea to .$cote,.'. 1 (2) 4,441!.adlatIve:.looailon off;- :1�roD ei3ir eekf%to tank•. diiitoeai Geld, WG1I. garage, and offer dilt c�'ing :43) Make • -Irma' +or san r• betty' 44.4e ` ar atramD3� dtra or ax►p • other.iuip an •toDograDb1 detieiid. • 1D&te. when. t t....ltioia ..ri11 be r adY ,Por •.`. it s ec foti' •• _.::.x.:•_ ..:.::1:.:........ .:_.'Date.:1oAtsilati ii be nreltdj+:tor.< ~ on,,aa1 riel..iaiiipeiitian t�biit;:ie,: . $ik 4fl ARIAN•'S' ARPCORT : AND 'RiOOM L IA11bNS: .. Ground Wate---... Cb '.d�.i' k:••• ,... i:. ,..:� :_ t.; ,,:ice .... ._ it .. .. ! _c•�l1FC61atitlti tC•L.il{8:: .r:�: ,:a . `. ».::r.: r+:.:.:i•: .�;. 1' crown 846 itir st btt •04.) JUN 21 2006 14:35 5093241567 PRGE.01 Date: 6/19/2006 Page 1 of 2 lnv:1 . Application Project Number: 06002373 permit THIS IS NOT A PERMIT without a p T Penalties will be assessed for commencing Pro'ect In ormatiContact: GISOLO, MARTIN R on: a F 4 ? ,fi t� f Address: 1423 N LIR EY, WA 99206 Permit Use: 30 x 30 POLE BUILDING C S - Z: SPOKANE Phone: (509) 328-4431 Left: Right: Rear: Setbacks: Front laraavaawaro Group Name: ,� Districtrt Nort Project Name: Site Information_ Plat Key: Name: Parcel Number: 35131.0305 SiteAddress: 1423 N LILY RD Location:: CSV Zoning: UR -3.5 Water District: Area: 12,344 Sq Ft Nbr of Bldgs: 0 Block: Urban Residential 3.5 Review Information: Review Building Plan Review Width: 0 Nbr of Dwellings: 0 Landuse/Zonin /HE Conditions Lot: Owner: Name: GISOLO, MARTIN R Address: 1423 N LILY RD WA 99206 SPOKANE VALLEY, Hold: ❑ Depth: 0 Right Of Way (ft): 0 Released I Releaser Permits: Contractor: OWNER Operator AMB Building Permit Firm: OWNER Phone: (000) 000-0000 Printed By: AMB Print Date: 6/19/2006 Sjakane 41 .Walley Community Development Permit Center 11707 E Sprague Ave, Sid 106, Spokane Valley, WA 992 ;n- (509)688-0036 FAX: (56918603<' Www.spokanevalley.org c`ori Residential Construction Permit Application JUi i/ 15 2006 i3/New Construction o 'Acldition/Remiodel o Other: PERMIT NUMBER: o'Z3'73 PERMIT FEE: o Accessory Bldg o Deck SITE ADDRESS J` / �' ! , Li k t• ASSESSORS PARCEL NO: 3 � �I , 03175- LEGAL DESCRIPTION: Building owner Name: kai7' at 5 O `6 ` Address: Name: ilet/it/ /¢ fes' 77 6/$ diG Lic No: Exp. Date: Address: i ...3 Ad, L i L IMPERVIOUS SURFACE AREA: CityPOior lit4.1 Zip: 9 9 2/ -2_ PhonZXZ --W3/ ax: CONSTRUCTION TYP: Pv/e 424r/3 Contact Person' Name: £ i?zry &71-5c) Phone: 32 4*3/ Describe the scope of work in detail: Contractor Name: kai7' at 5 O `6 ` Address: City: Zip: Phone: Fax: Lic No: Exp. Date: City Business Lic No: Cost of Project: $ I el 0 ************** lJ ********************** The following MUST be co plete: (write N/A if not applicable) HEIGHT TO PEAK: DIM f�'r^ # OF STORIES: ,r TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGES.. ,$T / O (o DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYP: Pv/e 424r/3 HEAT SOURCE: SEWER OR SEPTIC? DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additionaation may be required to be submitted, and subsequently approved before this application can be processed. Signature Date Method of Payment: (Faxed permit applicatio will only be accepted with major bankcard) 0 Cash ❑ Check 0 Mastercard 0 VISA Bankcard #: Expires: VIN#: ❑ Other Authorized Signature: REVISED 8/25/2005 Steel PLANN BY: DATE: TM G DEPT. APPROVED Tubing • Pipe • Rebar • Plate & Sheet Structural Shapes • Processing Services 925 North Oregon Ave. • P.O. Box 3035 • Pasco, WA 99302-3035 LOCAL 545-0688 WA, OR & ID FAX 1-800-237-1742 (509) 545-0697 www.pacific-stee ckv fl 114' .T o� f _T .16 TYPICAL GIRT CONNECTION PURLIN CONNECTION METHODSI A). PURLINS MAY BE HUNG V. NAILS EACH GIRT OFF THE TRUSS TOP CHORD FACES W/ STANDARD SIMPSON JOIST HANGERS OR EQUAL, B). PURLINS MAY BE BUTTED AND NAILED W/(2) 16d NAILS (FLAT) INTO EACH PURLIN, C), PURLINS MAY BE LAPPED AND NAILED W/(3) 16d NAILS ON CONNECTION METHODS 'B' AND 'C', TOENAIL BACK SIDE OF PURLIN W/0) 16d NAIL INT❑ EACH TOP CHORD MEMBER NOTES FOR FLOOR PLAN Q INTERIOR FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET Q GABLE WALL POSTS - 6' X 6- TYPICAL DOOR POSTS - 4' X 6' TYPICAL FOOTING DIMENSIONS, B + 1' 8'1 D = 3' 0' MAXIMUM POST SPACING 12' 0' (3 PURLINS @ 24' O.C., BEARING OR JOIST HANGERS (TYPICAL) w SPANS 12' TO 60' IN A N } J ¢ a DOUBLE TRUSSES SEE S3 J NOTES FOR SECTION A -A FOR -J-_ O TYPICAL PURLIN, SEE FLOOR S1 REQUIRED - PLAN FOR SIZE SAIL N- S2 TRUSS DESIGN BY OTHERS N Z mN tat ------_-_ Q W 2' X 6' @ 24' D.C., 12' BAYS 18" AND MUST EXTEND DF -L #2 GIRTS FLAT @ 24' 0. C. JJ C30 S4 CONCRETE FOOTING, SEE SCHEDULE LAMINATE MAY BE SPLICED ABOVE MID _J C3 0-'J W Ld ROOF FASTENED TO PURLINS WITH 16'" to 1 1/2' LONG WOODFAST TEKS. �J CLw 0. 18'-0" GIRTS WITH 1' LONG G 0 o > �J o a coo A 2W -O" 6"XIV' o �D. J o x I x e, 8'-0" 6" X 6" 26" -O" NO 0.41 1&" 0 10'-0" 6'rX 6" _ 26"_ (Ua W 0- O 12-0" 12-0" 1r -E" 14'-0" -- 6"X 6" W/2" X 6"26' 6"X 6"UI%/2"X 6"_ ---- 26" T -O" _ Y NO _NO W CL 12-012-"- -- 1G'-0"- --- -- 6-" X 8" W/2" X 6" - -- 26" - - 3'-0" - 12-0" Bi_ +gUBLE TRUSSEQ _ 6" X 8" W/2"X 6" 26" z a A NO -J v� .V., zA..Uz _J o- T-2" NO- 0.44 POST/FOOTING n J� 1 m1- �~ �0. JKNEEBRACE CONCRETE SPACING "H" t "B" DIA. 'T' REQUIRED VOLUME, 10'-0" . aU O;flU 0 0 zaI NO 0.41 0.41 0.41 10'-0" 10`-0"_ --'- 10'-0" o o Nd• (ND L/ . ---. _--'----. ?u N N cu (n ui N 14'-0" 6" X_6" W/2"_X_ 6" 26" ...---.-. 3'-0"_ 0 cu 0.41 0.41 -- _ 16-0"_' ---- _ 6'; X 8" ---- -- _ _ 26" 3'-0" NO _ 10'-0" cu SINGLE TRUSS - 26"- -26'-'-' 26" --0"3' --- _ _ 3'-0"_ 3'-2"1 PLAN VIEW N.T.S, 12 4 W DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. 1'/ 1° 2 - 16d NAILS 111 oJ \ III .-t 111 6", 8" OR ��� 10" POST - �- N 0 i r 111 .4} - z POST COLUMN - SEE S3 J NOTES FOR SECTION A -A FOR O O TYPICAL PURLIN, SEE FLOOR S1 REQUIRED VOLUME, PLAN FOR SIZE SAIL J S2 TRUSS DESIGN BY OTHERS LAMINATIONS ZZ) S3 2'X6'@ 24' D.C., 10' BAYS NOTE: 2" X.6" LAMINATE MUST BE A Q W 2' X 6' @ 24' D.C., 12' BAYS 18" AND MUST EXTEND DF -L #2 GIRTS FLAT @ 24' 0. C. THE FOOTING. C30 S4 CONCRETE FOOTING, SEE SCHEDULE LAMINATE MAY BE SPLICED ABOVE MID SS EXTEND POST TO TOP OF PURLIN Y10 NO W Ld ROOF FASTENED TO PURLINS WITH 16'" to 1 1/2' LONG WOODFAST TEKS. - 3'" NO WALLS FASTENED TO 18'-0" GIRTS WITH 1' LONG 3'-0" WOODFAST TEKS, 0.24 IV-vl 2W -O" 6"XIV' _20" 21'` 3'-0" W DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. 1'/ 1° 2 - 16d NAILS 111 oJ \ III .-t 111 6", 8" OR ��� 10" POST - �- N 0 i r 111 .4} - BUILDING SECTION A -A N.T.S. OVERHEADSINGLE DOOR OPTION FRONT ELEVATION N.T.S. NOTES FOR FRONT ELEVATION SS HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6' OR 2' X 8' STD JOIST HANGERS, LOWER TRUSS FOR END OVERHANG, IF REQ'D S2 2' X 10' HEADER S3 2' X 6' GIRTS @ 24' O.C., 10' BAYS, DF -L #2 2' X 6' GIRTS @ 24' D.C., 12' BAYS, DF -L #2 S4 2' X 8' FACIA BOARDS SS TREATED WOOD POSTS, SIZED PER SCHEDULE S6 TREATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT NOTES FOR CONNECTION DETAIL (SD TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER S2 PURLIN SUPPORT STRUT 2' X '4' X FULL DEPTH OF TOP CHORD PLUS PURLIN, NAIL PURLINS W/(3) 16d NAILS S3 NAIL STRUT TO TOP CHORD W/(3) 16d NAILS EACH SIDE, S4 MANUFACTURED TRUSS. NOTCH POSTS 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT. S5 WOOD POST, SEE POST/FOOTING SCHEDULE. S6 4 - 40d GALV. NAILS IN PRE -DRILLED HOLES OR 3/4'0 MACHINE BOLT S7 SOLID BLOCKING AT CONNECTION POINTS, 0 TYP, PURLIN, SEE FLOOR PLAN FOR SIZE S9 2' X 6' OR 2' X 8' TOP GIRT S1 4 - 16d NAILS OR 3/4'0 M. BOLT DOUBLE OVERHEAD DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR DETAIL 2- KNEEBRACE S1 TRUSS TOP CHORD, DESIGN BY OTHERS S2 TRUSS BOTTOM CHORD, DESIGN BY OTHERS S3 2' X 6' DF -L #2 EACH SIDE S4 WOOD POST, SEE POST/FOOTING SCHEDULE S5 4 - 16d GALV. NAILS, EACH SIDE 1). KNEE BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE, BRACE NOT REQUIRED ---AT GABLE END TRUSSES. 2), ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECTION = USE 3/4'0 THRU BOLTS, EACH LOCATION, N.T.S. BUILDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE 8 AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = i PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF -L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IBC: ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksL ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL.TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, LAT GASKETED 1 OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE IN WHICH THE BUILDING WILL BE CONSTRUCTED. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF II ISI IIW TRUSS WEB BRACING r -SLIDING T.. INTERIOR OR GABLE SND TRU SINGLE SL,DIdvG DOOR OP I ICN - ,>-,,_ TRUSSES OPTIONAL FRONT ELEVATION NOTES FOR TRUSS WEB BRACING! TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS qS CEE�3 N.T.S. THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES 1' X 4' DR 2' X 4' WEB MEMBER BRACING FOLLOW THESE INSTRUCTIONS FDR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB 41 12 1 10d NAILS @ 6' D.C. Od NAILS @ 6- D.C. X 6' OR 2' X 8' X 4' L -BRACE L -BRACE I S, TRUSS WEB MEMBER TRUSS WEB MEMBER SHEATHING R 0 IRM NTS THE FOLLOWING MINDIUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED. ;. ■ ROOF STEEL. 29 GAUGE GRAND -RIB III, 36' WIDTH DR EQUIVALENT ■ FIELD SCREWS #10 x 1 1/2' AT 9' D.C. (NEXT TO MIGH RIB) I ' ;' ■ EAVE AND RIDGE. FURLIN SCREWS #14 x1 1/2' AT. BOTH SIDES ,DF EACH MAJOR RIB '" THE FOLLOWING MINItIUM ENDWALL DIAPHRAGM REQUIRMENTS ARE"NEEDED, ■ ENDWALL STEEL, 29 GAUGE GRAND -RIB III, 36" WIDTH OR EQUIVALENT It FIELD SCREWS. #16 x 1 1/2' @ 9. D.C, (NEXT TO HIGH RIB) ■ BASE GIRT, END TRUSS, AND DOOR HEADER SCREWS, #14 x 1 1/2' @ BOTH SIDES OF EACH MAJOR RIB, SECTION B -B SECTION B -B DIAPHRAGM SCREWS AT INTERIOR TRUSSES AT GABLE END TRUSS NOTES FDR FO❑TING DETAIL S1 TREATED POSTS AS SIZED PER SCHEDULE 2 VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING �3 UNDISTURBED SOIL FOOTING DETAIL N.T.S. -GABLE END TRUSS 8 - 16d NAILS--�, OPTIONAL FRONT ELEVATION N.T.S. 16d NAILS 2' X 6' X 18' ° BOLTING BLOCK CORNER POST 8 - 16d NAILS ' BOLTING BLOCK DETAIL 3 TYP, GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS SPLIT SLIDER DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS S1 HALF TRUSS DESIGN BY OTHERS S2 2- X 10' HEADER UP TO 12' 0' DOORS 2' X 12' HEADER UP TO 20' 0' DOORS 2'Y, 12' BACKED WITH 2' X 6' UP TO 24' 0' S3 2' X 6- HEADER S4 4' X 6' DOOR POST - 8' THRU 14' WALL HEIGHT W/ 2' X 6' FACER, 6' X 6' DOOR POST - 16' & 18' WALL HEIGHT W/ 2' X 8' FACER. SS DOUBLE 2- X 6' KINGPOST G TYPICAL SSRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING N.T.S. S1 GABLE END TRUSS S2 DOUBLE INTERIOR TRUSSES S3 2' X 4' X -BRACING @ 10' 0' D.C. S4 2' X 4- BOTTOM CHORD BRACING @ 10'-0' O.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER SS TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATION N.T.S. S1 2' X 8- HEADER S2 2' X 10' HEADER FOR 10' & 12' SLIDING DOORS 2' X 8' HEADER FOR 8' & SMALLER SLIDING D ENOWALLM13IIR EHEADERENBWGAH�EDAEN DGTRUSS TOPS CHORD, EAVE & RIDGE PURLINS ON RODE NNTED ABO EREWSt TYPICAL SCREW PATTERN, EXCEPT AS STEEL SHEETING SCREW PATTERNS N.T.S EXPIRES POST/FOOTING SCHEDULE 1r -24' SPANS, 30 &40 PSF LIVE LOAD POST COLUMN - SEE S3 NAILING PATTERN FOR D 'T' REQUIRED VOLUME, - 10'-0" SAIL 6" X 6" POST LAMINATIONS NO 0.20 NOTE: 2" X.6" LAMINATE MUST BE A TREATED MEMBER r. 18" AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. _ .. LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN BUILDING SECTION A -A N.T.S. OVERHEADSINGLE DOOR OPTION FRONT ELEVATION N.T.S. NOTES FOR FRONT ELEVATION SS HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6' OR 2' X 8' STD JOIST HANGERS, LOWER TRUSS FOR END OVERHANG, IF REQ'D S2 2' X 10' HEADER S3 2' X 6' GIRTS @ 24' O.C., 10' BAYS, DF -L #2 2' X 6' GIRTS @ 24' D.C., 12' BAYS, DF -L #2 S4 2' X 8' FACIA BOARDS SS TREATED WOOD POSTS, SIZED PER SCHEDULE S6 TREATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT NOTES FOR CONNECTION DETAIL (SD TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER S2 PURLIN SUPPORT STRUT 2' X '4' X FULL DEPTH OF TOP CHORD PLUS PURLIN, NAIL PURLINS W/(3) 16d NAILS S3 NAIL STRUT TO TOP CHORD W/(3) 16d NAILS EACH SIDE, S4 MANUFACTURED TRUSS. NOTCH POSTS 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT. S5 WOOD POST, SEE POST/FOOTING SCHEDULE. S6 4 - 40d GALV. NAILS IN PRE -DRILLED HOLES OR 3/4'0 MACHINE BOLT S7 SOLID BLOCKING AT CONNECTION POINTS, 0 TYP, PURLIN, SEE FLOOR PLAN FOR SIZE S9 2' X 6' OR 2' X 8' TOP GIRT S1 4 - 16d NAILS OR 3/4'0 M. BOLT DOUBLE OVERHEAD DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR DETAIL 2- KNEEBRACE S1 TRUSS TOP CHORD, DESIGN BY OTHERS S2 TRUSS BOTTOM CHORD, DESIGN BY OTHERS S3 2' X 6' DF -L #2 EACH SIDE S4 WOOD POST, SEE POST/FOOTING SCHEDULE S5 4 - 16d GALV. NAILS, EACH SIDE 1). KNEE BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE, BRACE NOT REQUIRED ---AT GABLE END TRUSSES. 2), ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECTION = USE 3/4'0 THRU BOLTS, EACH LOCATION, N.T.S. BUILDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE 8 AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = i PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF -L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IBC: ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksL ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL.TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, LAT GASKETED 1 OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE IN WHICH THE BUILDING WILL BE CONSTRUCTED. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF II ISI IIW TRUSS WEB BRACING r -SLIDING T.. INTERIOR OR GABLE SND TRU SINGLE SL,DIdvG DOOR OP I ICN - ,>-,,_ TRUSSES OPTIONAL FRONT ELEVATION NOTES FOR TRUSS WEB BRACING! TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS qS CEE�3 N.T.S. THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES 1' X 4' DR 2' X 4' WEB MEMBER BRACING FOLLOW THESE INSTRUCTIONS FDR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB 41 12 1 10d NAILS @ 6' D.C. Od NAILS @ 6- D.C. X 6' OR 2' X 8' X 4' L -BRACE L -BRACE I S, TRUSS WEB MEMBER TRUSS WEB MEMBER SHEATHING R 0 IRM NTS THE FOLLOWING MINDIUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED. ;. ■ ROOF STEEL. 29 GAUGE GRAND -RIB III, 36' WIDTH DR EQUIVALENT ■ FIELD SCREWS #10 x 1 1/2' AT 9' D.C. (NEXT TO MIGH RIB) I ' ;' ■ EAVE AND RIDGE. FURLIN SCREWS #14 x1 1/2' AT. BOTH SIDES ,DF EACH MAJOR RIB '" THE FOLLOWING MINItIUM ENDWALL DIAPHRAGM REQUIRMENTS ARE"NEEDED, ■ ENDWALL STEEL, 29 GAUGE GRAND -RIB III, 36" WIDTH OR EQUIVALENT It FIELD SCREWS. #16 x 1 1/2' @ 9. D.C, (NEXT TO HIGH RIB) ■ BASE GIRT, END TRUSS, AND DOOR HEADER SCREWS, #14 x 1 1/2' @ BOTH SIDES OF EACH MAJOR RIB, SECTION B -B SECTION B -B DIAPHRAGM SCREWS AT INTERIOR TRUSSES AT GABLE END TRUSS NOTES FDR FO❑TING DETAIL S1 TREATED POSTS AS SIZED PER SCHEDULE 2 VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING �3 UNDISTURBED SOIL FOOTING DETAIL N.T.S. -GABLE END TRUSS 8 - 16d NAILS--�, OPTIONAL FRONT ELEVATION N.T.S. 16d NAILS 2' X 6' X 18' ° BOLTING BLOCK CORNER POST 8 - 16d NAILS ' BOLTING BLOCK DETAIL 3 TYP, GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS SPLIT SLIDER DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS S1 HALF TRUSS DESIGN BY OTHERS S2 2- X 10' HEADER UP TO 12' 0' DOORS 2' X 12' HEADER UP TO 20' 0' DOORS 2'Y, 12' BACKED WITH 2' X 6' UP TO 24' 0' S3 2' X 6- HEADER S4 4' X 6' DOOR POST - 8' THRU 14' WALL HEIGHT W/ 2' X 6' FACER, 6' X 6' DOOR POST - 16' & 18' WALL HEIGHT W/ 2' X 8' FACER. SS DOUBLE 2- X 6' KINGPOST G TYPICAL SSRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING N.T.S. S1 GABLE END TRUSS S2 DOUBLE INTERIOR TRUSSES S3 2' X 4' X -BRACING @ 10' 0' D.C. S4 2' X 4- BOTTOM CHORD BRACING @ 10'-0' O.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER SS TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATION N.T.S. S1 2' X 8- HEADER S2 2' X 10' HEADER FOR 10' & 12' SLIDING DOORS 2' X 8' HEADER FOR 8' & SMALLER SLIDING D ENOWALLM13IIR EHEADERENBWGAH�EDAEN DGTRUSS TOPS CHORD, EAVE & RIDGE PURLINS ON RODE NNTED ABO EREWSt TYPICAL SCREW PATTERN, EXCEPT AS STEEL SHEETING SCREW PATTERNS N.T.S EXPIRES POST/FOOTING SCHEDULE 1r -24' SPANS, 30 &40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED VOLUME, - 10'-0" -0 _ 8'" 6" X 6" 18" NO 0.20 10'-0" 10'-0" 6" X 6" 18" _3'-0" 314;_ _ _ NO 0.20 10'•0" - - 12'-0" 14'-0" ---- 6"X 6" 6" X iFW122' X 6" ----- 16' 18" _ 3'-0" 3'-0;' Y10 NO 0.20 0.20 10'-0" 16'" - 6" X 8" 26'--:-Z " - 3'" NO 0.24 18'-0" 6" X 10" 3'-0" NO_ 0.24 IV-vl 2W -O" 6"XIV' _20" 21'` 3'-0" NO 0.27 _ 12-0" 8'-0" 6" X 6" 26" -O" NO 0.41 1&" 0 10'-0" 6'rX 6" _ 26"_ _T 3'-0" _ NO - 0.41 12-0" 12-0" 1r -E" 14'-0" -- 6"X 6" W/2" X 6"26' 6"X 6"UI%/2"X 6"_ ---- 26" T -O" _ Y NO _NO 0.41 0.41 0.41 12-012-"- -- 1G'-0"- --- -- 6-" X 8" W/2" X 6" - -- 26" - - 3'-0" - -- NO 12-0" 18'-0" _ _ 6" X 8" W/2"X 6" 26" 3'-0" NO 0.41 T-2" NO- 0.44 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF LIVE LOAD, POST COLUMN I FOOTING JKNEEBRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED VOLUME, 10'-0" 8'-0' 6" X 6" 26" T -O" NO 0.41 0.41 0.41 10'-0" 10`-0"_ --'- 10'-0" 6" X 6" _ 26' 3'-0" _ NO ___- ---. _--'----. _ 10'-0" 14'-0" 6" X_6" W/2"_X_ 6" 26" ...---.-. 3'-0"_ NO 0.41 0.41 -- _ 16-0"_' ---- _ 6'; X 8" ---- -- _ _ 26" 3'-0" NO _ 10'-0" _18'-0"_ 22'.0" 6" X 8" W/2"6" X 6"X 8" W2"X 6" 6"X 10"WIT' X 6" - 26"- -26'-'-' 26" --0"3' --- _ _ 3'-0"_ 3'-2"1 --.. NO NO NO 0.41 0.41 0.44 - 10'-0" 10'-0" 24'-0" 6" X 12" 26" 1 3'3" NO 0.46 12-0" 8'-0" 6" X G" 28" T -O" NO 0.47 124" --0 12-0" 10'-0" .12:-0::- 6" X 6" BdX 6" W/2;;X s,� 28" --28"- 3'-0" NO 0.47 0.47 _.3'-0;� . -NO -_. -tO 0.47 0.47 12-0" 16'-0"28"_3'0" NO 0.47 12-0"- 20'-0^ 6" X 12" 28" 3'-0" NO 0.47 12-0" -0 22'-0,• ----- 6"X 12" W/2" -X 8': -- - -- 28„ 3{2:' -NO 0.6 12" 12-0" 24'-0" 6" X 12" 28' 3'4„- NO .... 0.66 POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF LIVE LOAD, POST COLUMN FOOTING I KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. "T' I REQUIRED VOLUME, Y _ 10'-0" 8'-0" 6" X 6" 28" 3'-0" 0.47 -10'-0" _ 10'-0;' 6" X 6" _ _ 28" 28'_ 3b"_ _NO _ NO _ 0.47 0.47 1V -W' 14'-0"_28' 3'-0" 0.47 10'-0"_ _16'•0" 6" X 8" 28" T:& _NO NO 0.47 - _ 3'-0" NO NO_ 0.47 0.47 -10'A" 10'-0" 22, -0;• 24'-0" irk 16"VII%2'rX 6'•-28,;------9;,0-•----NO 0.47 0.60 6" X 10" W/2" X 6" 28" 3'•2" YES 12-0" 814" 6" X 6" 32" T -O" NO 0.62 - -12.0" 12.0' 12.0" _12-0" 12-0" X 6" .....32„ 32" -3'-0" -X-O"- ..IJO NO 0.62 0.62 0.62 0.62 0.62 0.62 _ IZ-O" 14'•0" 16'.0" _ 6" X 6" W/2" X B' 6"X S" 6" X 8" W%Y' X 6" 6" X 10'; W12"X 6" _ _32'__3'-0"_ 32' 32"_3'-0"_NO 32" 3'-0" T -O" NO _NO NO _18'•0"_6"X10"- 20'-0" 12 -0" 1 -24' -0" - IS" X12"W/2"X6"--32" 8'3" --NO o.G6 0.68 - POST/FOOTING SCHEDULE 40' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" I W X D "B" DIA. I 'T' REQUIRED VOLUME, YDO 10'-0" 8'-0" 6" X 6" 30" T -O"_ NO 0.65 _ 10'-0" 12'-X" 10'-0" --- _14'-0" 16'•0" --- 6" X 8" - -- 30' 3'-0" YES 0.56 10'-0" -IOm-O" _ 1 _ 10'.0" -------- 10'-0" ------ _ 18'-0" _ 20'-0" ---__ 22'-0" ----- X 6" -------'-- --- 6" X 8" W/2" X 6"_ 6;; X 10" ------------- 6" X 10" W/2" X 6" ----- ----- _30"_ 30" 3-0;v- _ 30" - .30" --- - NO 0.66 0.66 0.56 0.66 0.68 ---0-' _3'-0" _ T -O" ----- _3'-0"_ 3':2" wo-- _NO NO -- _ NO __ YES 10'-0" _ 2N.Ol' IS" X 12" - 12-0' 12.0' 12-0` ----- 8141 _ 10-0' 12 O" Gll X All 33" T -O" NO 0.66 0.66 0.66 0.66 0.66 0.66 0.66 0.70 0.72 6 X 6 G" X.6 W12' X s" 33; 33 33' - 33 -- -33" 3'-0"" 3.O" -a,:0" 3-0 3-0' - 3'-0'_ _ NO - NO-- --NO_--_ NO NO --- - 12-0" 12-0 _ 12.0' - -12'-0" 12-0' 14,.,0„_G"X8„ 16-0' 16-0" 20'-0" 22'4" - --33" 6 X8 W/2"X_6" 6 X 10 ------ 6" X 10" W/2" X 6" iti X 12" 33 3 -2" _NO - NO 12-0" -0 24'" s" X 12"W/2""X 6" '33 3'-2 " NO POST/FOOTING SCHEDULE 48' TO 62'S S, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEEBRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED IVOLUME, 10'-0" --10,:0„ 8'-0" 6 X 6" 34" 3'-0" NO 0.70 0.70 10'-0" 6" x v. - --34„ 31:0" 10'-0; _ 14 A" 6"X 6" W%2" X G" 34" T -O" _-NO-- NO 0.70 0.70 0.70 6 X 8 _ 94" 3'-0" _ VES 10'-0' 16-0'6 X S W/2' X 6" 34' T -O" _ _ NO 0.70 __-.-.._---_-_-.__---_---- 6" 3'-0"_ NO 0.70 i614;-22 10'-0" -0' 24'-0" 6" X 10" W/2" X 6" _34" 34" T -O" _ _ NO 0.70 0.70 0.70 G" X 12"VIII%2'r X G" 34" 3'-0" YES - 12-0" _12_-0" W-0" 16;-F _ I Z -W' _ 6;-X 6 v x 6 W/2' X 6" 6"X_ 6" 11V%2" X 6" 36" 36" 3'-0" 3'4"_ _ NO NO 0.79 0.79 0.79 36' 3'-0" _ _ NO 12-0;; 14-& _ 16'-0"_ 6" X 8" _ 6"X 6" W%2" X 6" _ _ 36" _ 3'-0"_ 3'-0" _ _ _ NO _ NO 0.79 0.79 - _36" _ 0.79 12-0" -- 12-0" 20-0" 22'-0" 2N.O" 14"X 6"X 90" W%2"X s;' 6--"-X- 1,2 -"'w -/-2`-'X- 6" 12' W/2"X 6 36" 36"- - 38"- 9;-0" 3':2" - 3:2- _YES NO 0.79 0.83 0.83 - NO --- -- NO 12-0"1 POSTWOOTING SCHEDULE 54' TO 60' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING I KNEE BRACE CONCRETE SPACING "H" I W X D "B" DIA. 'T' REQUIRED VOLUME, 10'-0" --lo, 8'-0" --lo--_--- 6" X 6" 36" 3'-0" NO 0.79 10'-0" 10'-0" 6" X 6" ----------. 36" NO 0.79 _10'•0" --- 12'-0" ._--- 6;' X 8"W/2" X 6" _ 38" _3'-0" 3'-0" _ NO 0.79 0.79 10'-0" 10,--0'• ---" 10'-0" IV -O"- 18':0" --0" 6" X 8" W'--- 6" X 8" W/2" X 6" -1 -JX -- 36" --- 3'-0" --'--- NO 0,79 0.79 0.79 0.79 0.83 61 10" -- --38;•-- 3'-0" NO - 20'-0" .24,:0" 6" X 10" WF2--X-i;; 6" X 10" W w/z" x s" 6" X 12,-, ---- - 36" - -- 3'-0" YES as" --36';- a'-0" -3;_2-, No YES_ 1 12-0" _ 8'-0" G" X 6" 40" -O" NO 0.97 - 12.0' -_-12-0- 10'-0" -1Y4V 6" X 6" W/2" X 6" i", X6„ -46;7-3'-0" -_4F _T _ NO -_NO- 0.97 0.97 12-0" ---- 12-04 ---._ 12-0" _12-0" 14'-0" ----G"X&' _ 16'-0" ...--'-- 20'-0" 22:0"s" 6" X 8" W&T-xX 6" &'W12 -;i R s" X 8" W/2" X_6 ----------'- 6" X 10" W/2" X 6" X 1-r; 40" _- 3'4)" NO 0.97 0.97 0.97 0.97 0.97 1.03 3'-0" NO _40" ---- 40" ---- 3'-0" -- NO 6" X 12" W/2;; X 6" 40"- -32""- NO 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" X 6" LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 28"0 X 3'-0" DEEP FOR WALL HEIGHTS TO 16'-0". ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS(CONTRAINED POSTS). IF BUILDINGS WILL NOT HAVE CONCRETE FLOORS, INCREASE FOOTING DIAMETER X 2" & FOOTING DEPTH X 4". y,"BEKE ENGINEERING YOUT, STRUCTURAL DETAILS AND SPECIFICATIONS IST FRAME BUILDINGS 2221 NORTH FAIRCHILD DRIVE MEDICAL"`LAKE WA 99022 BY DATE DRAWING NOa DRAWN WAMBEKE 6-13-06 J&J.IBC2003-06 CHECKED BY DATE DESCRIPTION OF CHANGE PROJECT N0. 2006 ISCALE, N.T.S SHEET I DF I PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TPUSSES, BEAMS AND FLOOR SvSTEMS PRIOR TO FRAMING tNispEc'nuNs CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS or REVIEVVELj FOR J3LiC;OMPUANCE. SPOKANE ViTIFI',77,',1 r.)VisION TM