Loading...
2008, 04-08 Permit App: 08001197 Pole BldgProject Number: 08001197 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/8/2008 Page 1 of 2 Project Information: Permit Use: 24 X 48 POLE BLDG Contact: TOWN & COUNTRY Address: 5918 E TRENT AVE C - S - Z: SPOKANE, WA 99212 Setbacks: Front Left: Right: Rear: Phone: (509) 535-9016 Group Name: Site Information: Project Name: Plat Key: 002816 Name: WALNUT ADD District: Nort Parcel Number: 45172.1005 SiteAddress: 1103 N LOCUST RD Location:: CSV Zoning: UR -3.5 Water District. Area: 25,370 Sq Ft Block: Lot: Urban Residential 3.5 Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Owner: Name: GRANDYS, MICHAEL J/NELSON, Address: 1103 N LOCUST RD SPOKANE, WA 99206-4078 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Released By: Originally Released: Landuse/Zoning/HE Conditions 4/3/2008 By: tmelbourn Released By:. Originally Released: 4/8/2008 By: tschmidt Permits. Operator: JD Printed By: jmm Print Date: 4/8/2008 Project Number: 08001197 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/8/2008 Contractor: TOWN & COUNTRY BUILDERS Address: 5918 E TRENT AVE SPOKANE, WA 99212 Description Grp Type Notes POLE BDLG U-1 VB Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBC SURCHARGE Building Permit Page 2 of 2 Firm: TOWN & COUNTRY BUILDERS I Phone: (509) 535-9016 This Application: Total Project: Sq Ft Valuation Sq Ft Valuation 1,152 $21,888.00 1,152 $21,888.00 Totals: 1,152 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT $21,888.00 1,152 $21,888.00 Fee Amount $349.25 $87.31 $4.50 Permit Total Fees: $441.06 Notes: Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $441.06 $441.06 $0.00 $441.06 $441.06 $441.06 $0.00 $441.06 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: jmm Print Date: 4/8/2008 Sp®man � "Valley. Community Development Residential Construction Permit Application Permit Center 11707 E Sprague Ave, Suite 106 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 ww w.sDokanavallev.orE PERMIT NUMBER t ton PERMITTEE: New Construction ❑ Addition/Remodel ❑ Other: ?I -Accessory Bldg ❑ Deck Slit ADDRESS: IID) N1 Locus+ —90444 VA/4-Y / cefol 9924 ASSESSORS PARCEL NO:Ai DrI7� . (00S LEGAL DESCRIPTION: Building Owner: DIMENSIONS: /I -)y•-XYB'xt21-b.feur- # OF STORIES: . LL .. Contractor: Name. M aael ("eresicky S 2"u FLOOR SQ. FTG: -._.:__/V//%.•.:. .:'' UNFIN BASEMENT SQ. FTG: -- Name: -MUM/ It (ouu r&y &m. tf is lie. Address:3 n1• I..8Lust GARAGE SQ: FTG: f (Sa O /� DECK/GOV. P TIO SQ. FTG: N��- ' • Address: $9/e ERs-:TRF4✓T4i/ENGE City:S(la�Lt rte 410.1 telt tats Sas: , Zip City.: _stoma v,HeEi state:h4r,. Zip: 772/2 Phon�SO4i 3%U-1444 Fax:, :Phone: :53c.y; :. Fax:Se9 939 293a Contact Person Name: Ggt£ Bub, )E•Tr Phone: 509 53S 9016 Err 24 Describethe scope of work in.detaii:...- • Contractor Lic No:TWUt1�i3C6 Exp Date: 0413908 City Business Lic. No: 60/ 05'7 495-; -a: Cost of Project:_.$ l9,.Sao �y'x go'x I2.r•4' 614-06CI Proposed Use: **************The following MUST be complete: (write N/A:if•not aDn&able)********************** HEIGHT TO PEAK t-7' DIMENSIONS: /I -)y•-XYB'xt21-b.feur- # OF STORIES: . LL .. TOTAL HABITABLE SPACE: N - MAIN FLOOR TO SQ. FTG: N A- -- 2"u FLOOR SQ. FTG: -._.:__/V//%.•.:. .:'' UNFIN BASEMENT SQ. FTG: -- IMPERVIOUS SURFACE AREA: FINISHED B SEMS T SQ. FTG: N�f�' GARAGE SQ: FTG: f (Sa O /� DECK/GOV. P TIO SQ. FTG: N��- ' 30% SLOPES ON P nPF 7y; NO # OF BED OMS: /V - CONSTRUCTION TYPE: Po sr FR4144 HEAT SOURCE: A/I4,-- SEWER R SEPTIC? The permifee verifies, a nowledges and agrees by their signature that: 1) If this pens t is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Perrnit inure to the property owner. 3) The sig natory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances 6) Plans or additional information may be required to be submitted, and subsequently approved before this.application can be • •cessed. y• SIGNATURE: Method of Pay ❑ Cash Bankcard #: Authorized Signature: REVISED 2/15/D7 0. Check ❑ Mastercard Expires: DATE: "Pit 3 20oNg ❑ VISA VIN#: Spokane Valley o For City Use Only R PLUS Project Number �t 4 ! \G% Project Address i)OE- X) LQccdhr- 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revi ed target date. I I Your application review TARGET DATE is The TARGET DATE is the date we estimate your project application will have had' its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review i Submit complete, accurate plans and documents. Evtra time may be required for re -submittals as project application reviewers work 00 multiple applications and it nrar be several Jars before they can look at your new or revised information. i Designate a specific contact person to communicate with the City. IVhile the person designated as the applicant's contact person with the Citv can he changed, one individual with the expertise farr dealing with reviewer continents would be the best choice for the entire review process. Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date. please feel five to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By .following this procedure, you will save time and allow the reviewers to complete the work more expeditiouslv. Steps in the Permit Process I. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre -Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete. your application will be routed to the appropriate staff and remain in their review queue until it comes tip for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff niay include multiple reviewers. You should be contacted by phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re - submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre -construction meetings (if required) will be provided by the Permit Specialist at that time. . WHITE -APPLICANT PINK- BUILDING FILE REV 9/07 rcr1nit 6R-IM'I r 1.5 /1o3 ni I-00 (6— 401440J& Ater, wa u5/?z,/Oo•c PLANNING DEPT. BY.� DATE: `1/4/de e�.64n ase Locks+ o v er) Len {b�cr I n,,,• WAMBEKE ENGINEERING 2913 East 61st Court Daniel Wambeke, P. E. Spokane, WA 99223 Telephone: 509-443-6186 • Fax: 509-448-6582 • dwambeke @msn.com STRUCTURAL DESIGN DRAWINGS FOR 24' X 48' X 12'6" POST FRAME BUILDING FOR MICHAEL GRANDY'S SPOKANE VALLEY, WASHINGTON JOB NO. SP 8744 PREPARED FOR TOWN & COUNTRY BUILDERS, INC. SPOKANE, WASHINGTON April 3, 2008 EXPIRES f i • 2-41',4 Designer o! Small Structures, Post Frame Buildings, Foundations, Light Gauge Steel Framing and Grain Storage Systems .b Zee Wind Load Live Load Desi • n Criteria Dead Load Bay Spacing PLF 3o Psf 5- PsF iZ Fr Vzo P 87y "cijeL 6 4 J ?s sfo ,,1E Uht-Ler, 14/4 ZY' x `ex /2' qua 0X4 70744, is - EXPIRES (L 7 Grkad c re -S---' Pori L P l2 : 60 ,cT �11 a Da 4 a p Scc 1 g _a_1ou, 11 FnoTI1\1 C 17FTA7/ FOSTI FGOT / NG r2.E L04,4 y /oA/ SCNEOuL E Foor,A)6 512-E ( V qb GX .!- lo# x j1 -(o"x 3' ip lc 5.86G 64 r.- B" . , l-9' x 31-6" AIL OrliEKS 44.6 1164 Y /1-61 x 3.-6" EXPIRES IL- u1 t&-cl SP87Yq CoRn EES U RI FTVR_ JO 11,41 41A-Lts S u PfeuT Btacit 10 1a /* r r.s Gran 5-_Adn/AiLs 12 /64) AfitiLS S -u PPo-T L oc% s I z 1 dd Nuts 6i P -T5 git NittLs dorrom Ci/oRb Tt65 a x, OF --t Z SFr t) msr 1444)6egs ~, 7?45s 0o7 -7o' C OIL'S 5P'40416- TN TE.)2,1oR. 2-2x6 Fidgal 84641. CAirC `7 If1A-4LS To RA-FrE125 vR- 6)12 -Ts '1 /id Ah s a� u p2,4S W ail q 41461.: Tb PvwEt'Jlatieks PctP—LiAJ -ropUtEA) EXPIRES .24`c4 Sp 87ff " STEEL Boos ZX_ fu24•t/S 2y•'e.c Jrµ lnArifER s ovik4fPFED &YPI(4L? fl�., �X.._DiVeta Tp coos 0-vERLAerED 41:r k,L L '� \ •".I\ a tx_DealiL BorroM Cjtox~,os E Sapp ,o S' /1r e itItE g. CSR SteTi of TRt( z x8 Aoy&L rq Caroms 2)t. h ow8 i-rbp a l p'•b 2xia 00414 Top cHocDS 2 x6. wud&N� '. Til zx(v EtocK/4/C- 2y" LoA16- 2x ►Z BCL # MS 3/y" rTai. Foe's .HOZ . lirnioc F.Ks ¥ Au- Boers A-4. A /11,0 Iwo of z" p! c49 ?gem Eoce of thel To Nat- ePAo‘r if /a hers frfa k 04411h OF 3" x : VrPosr Mai GENS Ahsocr ib eang **tr. HIM/kit f1*kCTio9 DF SUSS wAti sesm D ciip q •S • R .S.h icS[rf 3 ICI 403 ,Sli s ks cht lb P401,0 Sti.8 FASO Codr/VEcriV4l 77 PvlL r. / Wsr0140 Roof Ova PA 6.1 - 44/413 81r-4414 £tra.+ij°&'��: gq F reric i4Q4& ( t yfcrii4) TQ E"4 RAF,r rZ- Ovceti6 1 EXPIRES(S 2-?` I SPB7yy 14 Watip 3 /0 4Q1/$ 5U8F4S4if To P4 'M/ ✓ l 4' 5 `7 \1;17 N4 ij POP 4) To XPIRES IG` 4 69F o V E I imd 6 FkA'nI41 6' . 0 crifa., 11 .+98'yY EXPIRES /L -v 1 • FAD 1ffr s (-o' 4A 1- 2x io Lc -L Z Kise 1,110 x'10 — cr'oios0 Y8; i. U 3f 874N U2jpan _ 1/3 Span 114 ,spy Purling t=1...4t Zy " oc run of rafter . N•`—Top Chord to Bottom Chord '—Top Chord to Post "—Support Block to Post —Shear Block to Poet Rat Runs @ Girts 2X6 OF -02 a 24" oc 2X10 PT IlaIlk2Assl birdwa,lK RitIGE Ili • Bolts if/ %p mats l 4 1 Bolts u/ trails IG 2 :8730:1 ts w/(� naps Ibd L ts w/ (o nails !bd (111 Eo r'E40 Live Load Dead Load Othr Load 30 psf psf 0 psf Total Load 3S psf PLF 410 Truss Width 2 �T Z Roofing. & Siding 29 Guage Steel PaF1416 OAK 304 Ftcr f '/6nosB DOUBLE TRUSS Top Chord ZX►o kr-112- Bot r{1t Bot Chord 20o OF.L'EL Webbing 24prL*z Bolts 3/4 1+ 4114,00 2-2X6 Blockin 6X 6 PT 1211.+1 _1±14___ .6 retension • 2Xj GiriiB TYPICAL CROSS SgCTION " Concrete Sia 7 u i kinn-, O AIMf'l 0 n n 1 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION.CORIECTIONS sky R SPOKANED AOR CODD•� O DIVISION E —rte O�