2007, 04-16 Permit App: 07001268 Mechanical Fixturef
Permit Center
S m0%anessalgiNa11707 E Sprague Ave, Suite 106
P Spokane Valley, WA 99206
Community DevelopmentPERMIT NUMBER:
® Ualle y (509)688-0036 FAX: (509)688-0037 PERMIT FEE: I ! ��
µ-1r11. spokanevallev on
Mechanical Permit Application n Commercial fl Residential
SITE ADDRESS: l .0 R. Ai. Locust gd
Building Owner �hlG .lno"- CODI[.._
-
Name. .S/1:h/r1�1 C'rolL
Phone:4e4 Fax:
�v2/-U�7 �aK-10S3'�
Address: z% mcutsy. get
City(��`I, 1) State: (,(�
Zip: �Qz0/
Contractor-'- : -
I -
„ 0 N
Name:(lIl M""
Phone:
Fax:
C •
Address:
City:
State.
. Zip:
License No:
City Business Lic-
.•
Name: .& 11 Q Yhn,t.-ncn✓t
Phone: qq 1.4 rig u.
DESCRIPTION OF WORK
# OF UNITS
X
COST
= TOTAL AMOUNT
FUEL BURNING APPLIANCE
Equal to or less than 100,000
X
$12 00
TL• an+
2
FUEL BURNING APPLIANCE
More than 100,000
X
$15.00
3
UNLISTED APPLIANCE (Additional Fee)
Equal to or less than 400,000
X
$50 00
4
UNLISTED APPLIANCE (Additional Fee)
More than 400,000
X
$100.00
5
USED APPLIANCE (WSEC min. AFUE rating)
Equal to or less than 400,000
X
$50 00
6
USED APPLIANCE (WSEC min AFUE rating)
More than 400.000
X
$100 00
7
BOILER/REFRIGERATION
1 - 100M BTU
X
$12 00
8
BOILER/REFRIGERATION
101 - 500M BTU
X
$20.00
9
BOILER/REFRIGERATION
501 - 1,000M BTU
X
$25 00
10
BOILER/REFRIGERATION
1,001 - 1,750M BTU
X
$35 00
11
BOILER/REFRIGERATION
More than 1,750M BTU
X
$60.00
12
GAS LOG. GAS INSERT, GAS FIREPLACE
X
$10.00
13
RANGE
x
$10.00
14
DRYER
X
$10.00
15
FUEL BURNING WATER HEATER
X
$10 00
16
MISC FUEL BURNING APPLIANCE
X
$10.00
`per. J0
17
GAS PIPING (each outlet)
X
$1.00
18
DUCT SYSTEMS
X
$10 00
19
VENTILATING FANS
X
510 00
20
AIR HANDLER (DOES NOT include ducting)
Equal to or less than 10.000 CFM
X
$12.00
21
AIR HANDLER (DOES NOT include ducting)
Greater than 10,000 CFM
X
515 00
22
EVAPORATIVE COOLERS
X
510 00
23
TYPE I HOOD
X
$50.00
24
TYPE II HOOD
X
510.00
25
HEAT PUMP/AIR CONDRIONER
0-3 TON
X
512 00
26
AIR CONDITIONER
3-15 TON
X
520.00
27
AIR CONDITIONER
15-30 TON
X
525 00
28
AIR CONDITIONER
30-50 TON
X
535 00
29
AIR CONDITIONER
More than 50 TON
X
560.00
30
LPG STORAGE TANK
X
$10.00
31
WOOD OR PELLET STOVE/INSERT
X
$10.00
32
WOOD STOVE - FREE STANDING
X
525.00
33
REPAIR E. ADDITIONS
x
$15.00
34
VENTILATION SYSTEMS
x
$12.00
35
VENTILATION MECHANICAL EXHAUST
X
$12.00
36
INCINERATOR — RESIDENCE
X
$19.00
37
INCINERATOR — COMMERCIAL
x
$22.00
METHOD OF PAYMENT:
❑CASH 0 CHECK '0 VISA 0 MC
CARD #:
AUTHORIZED SIGNATURE:
REVISED 8/26/05
EXPIRES'
VIN
SUBTOTAL
12.00
PROCESSING FEE
535.00
TOTAL PERMIT FEE DUE:
45. oa
Method III Worksheet for Fresh & Combustion Air
Job Address:
Furnace model #:
Furnace brand name:
Water heater brand name:
Install Foreman: r -
BTU input:
BTU input:
1
Ventilation Rate Determination
Floor area (sq. ft.) of the residence (basement + 1st floor + 2nd floor + bonus room) _
Number of bedrooms in the residence =
Using the table on the back of this form determine: .
Minimum Ventilation Air = CFM
Maximum Ventilation Air _ CFM
Formula for Combustion Air
1 - For fan assist vented furnace x 1,000 BTU input x .4 CFM/BTU = CFM
" 2 - Power vented water heater (use 90 CFM if rating unknown) = CFM
3 - For draft hood appliances x 1,000 BTU input x .8 CFM/BTU = CFM
Total CFM Required for Combustion Air (add 1+2+3). = CFM
The ventilation/combustion air duct must provide adequate combustion air or outside combustion air must be provided
separately from ventilation air. (Outside combustion air may be provided with one duct in the upper 12 inches of the enclosure
sized at 1 sq. inch per 3,000 BTU input of all appliances in the enclosure).
6"= 50- 80
7= 80-125
8"=115-175
Capacity of Round Metal Duct in CFM
9"•= 170 - 240
10"=.235-315
12"=395-495
Size of round duct
to return air drop =
1. For lengths over 20 feet increase the duct diameter 1 inch.
2. For elbows numbering more than 3, increase the duct diameter 1 inch. -
3. Insulate the ventilation/combustion air duct within the conditioned space to a minimum R-4.
Size of opening in wall of appliance enclosure (if confined space less than 50 cubic feet per
1000 BTU input) per U.M.C. and INWHVAC Assoc. standards book (2 openings sized 1 sq. in.
per 1000 BTU input of all appliances in the enclosure) = square inch
(net free area = 65% for metal louver - 25% for wood louver) _
Verification of proper drafting? YES NO
Verified by: License #
Company name:
Leave copy of this form on the job site at or on the furnace!!!
Updated 7-1-2001
Ventilation rates for all group R occupancies 4 stories and less*
" For residences that exceed 8
bedrooms, increase the minimum
requirement listed for 8 bedrooms
by an additional 15 CFM per bedroom.
The maximum CFM is equal to 1.5
times the minimum.
Bedrooms
Area ft2
2 or less
3
4
5
6
Min.
Min.
Max.
Min.
Max
Min.
Max.
Min.
Max
Min.
Max.
<500
50
75
65
98
80
120
95
143
110
_165
501-1000
55
83
70
105
85.
128
100
150
115
173
1001-1500
60
90
75
113
90
35
105
158
120
180
1501-2000
65
98
80
120
95
143
110
165
125
188
2001-2500
70
105
85
128
100
150
115
173
130
195
2501-3000
75
113
90
135
105
158
120
180
135
203
3001-3500
80
120
95
143
110
165
125
188
140
210
3501-4000
85
128
100
150
115
173
130
195
145
218
4001-5000
95
143
110
165
125
188
140
210
155
233
5001-6000
105
158
120
180
135
203
150
225
165
248
6001-7000
115
173
130
195
145
218
160
240
175
263
7001-8000
125
188
140
210
155
233
170
255
185
278
8001-9000
135
203
150
225
165
248
180
270
195
293
>9000
145
218
160
240
175
263
190
285
205
308
" For residences that exceed 8
bedrooms, increase the minimum
requirement listed for 8 bedrooms
by an additional 15 CFM per bedroom.
The maximum CFM is equal to 1.5
times the minimum.
Bedrooms
Area ft2
7
8
Min.
Max.
Min.
Max
<500
. 125
188
140
210
501-1000
130
195
145
218
1001-1500
135
203
150
225
1501-2000
140
210
155
233
2001-2500
145
218
160
240
2501-3000
150
225
165
248
3001-3500
155
233
170
255
3501-4000
160
240
175
263
4001-5000
170
255
185
278
5001-6000
180
270
195
293
6001-7000
190
285
205
308
7001-8000
200
300
215
323
8001-9000
210
315
225
338
>9000
220
330
235
353
" For residences that exceed 8
bedrooms, increase the minimum
requirement listed for 8 bedrooms
by an additional 15 CFM per bedroom.
The maximum CFM is equal to 1.5