2014, 11-18 Duct Testing CalculatorDuct Testing Calculator (New Construction)
House address or lot #:
Conditioned Floor Area:
Duct tester location:
• Pressure tap location:
Ring (if applicable):
q j2m E , i-tia ,u
(a,) i -}U '
gj
0
Open ❑ 1 O 2 0 ❑
At Rough -In or Post Construction
Test Method
Standards
Calculated
Target
Testi
CFM2s
Alr Handler Present (Leakage
to Exterior or TotarLeakage)
< 4 CFM25 per 100 sf of CFA
cg (O
w
Air Handler not Present
5 3 CFM25 per 100 sf of CFA
Leakage to Exterior or Total Leakage)
1.- Test CFM25 must be equal to or less than the calculated target.
Air Leakage testing Calculator (Blower Door Test)
_ Conditioned Floor Area:
Ceiling Hieght (ft)
)L4b1p
Calculated Volume (cubic feet)
gj
0
Standard
Tested CFM50
Calculated Test
Result (ACHso)
ACHso (CFMSoX
<_�-127
60 - conditioned Volume)
`
a, ZZ
Glossary
Rough -In: After installation of the complete air distribution system but before installation of insulation and
sheet rock. Allows for access to all duct seams and connections for re-evaluation of seal integrity if standard
is not rnet in intitial test.
Post Construction: At or near final inspection. The home must be complete enough to pressurize the home
to 25 pa.
Total Leakage: Aggregation of the entire systems duct leakage in a duct test.
Leakage to Exterior: Aggregation of all duct system leaks to the exterior of the CFA in a duct test.
Pascal (pa): Unit of pressure
CFA: Conditioned floor area in square feet
CFM25: Cubic feet per minute of air leakage at 25 pascals of pressure
CFMso: Cubic feet per minute of air leakage at 50 pascals of prt
Conditioned Volume: Volume of conditioned space (CFA X ceil
ACHso: Air changes per hour at 50 pascals of pressure