Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2006, 04-21 Permit App: 06001381 Residence
Project Number: 06001381 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/21/2006 Page 1 of 3 Project Information: Permit Use: SFR, GAS HEAT, ON SEWER Setbacks: Front Site Information: Plat Key: Contact: VIKING CONSTRUCTION INC Address: 2605 W HAYDEN C - S - Z: HAYDEN LAKE, ID 83835 Left: Right: Rear: Phone: (208) 762-9106 Group Name: Project Name: Name: Hidden Valley District: East Parcel Number: 55073.1901 Block: Lot: SiteAddress: 17219 E MANSFIELD AVE Location:: CSV Zoning: UR -3.5 Water District: Area: 6,949 Sq Ft Urban Residential 3.5 Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Owner: Name: VIKING CONSTRUCTION INC Address: 2605 W HAYDEN HAYDEN LAKE, ID 83835 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Originally Released: Landuse/Zoning/HE Conditions 4/20/2006 By: TMELBOU Sewer Review Originally Released: 4/18/2006 By: CJJANSSE easel Permits: Operator: AMB Printed By: AMB Print Date: 4/21/2006 Project Number: 06001381 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/21/2006 Page 2 of 3 Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Item Description APPROACH -CONST IN ROW Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Description Grp Type 1&2 FAMILY R-3 VB 2ND FLOOR R-3 VB BASEMENT U R-3 VB DECK OPEN R-3 VB GARAGE U-1 VB Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Notes Contractor: AIR DESIGN INC Address: 1807 E FRANCIS AVE SPOKANE, WA 99207 Item Description GAS WATER HEATER GAS APPLIANCE<=100,000BTU GAS PIPING AIR CONDITIONER:4-15 TONS VENTILATING FANS RANGE HOOD -TYPE II Approach Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 Units Unit Desc Fee Amount 1 NUMBER OF $50.00 Permit Total Fees: Building Permit $50.00 Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 This Application: Total Project: Sq Ft Valuation Sq Ft Valuation 1,000 $86,370.00 1,000 $86,370.00 482 $35,995.76 482 $35,995.76 986 $14,790.00 986 $14,790.00 124 $1,860.00 124 $1,860.00 493 $9,367.00 493 $9,367.00 Totals: 3,085 $148,382.76 3,085 $148,382.76 Units 1 1 1 Unit Desc SELECT SELECT SELECT Permit Total Fees: Mechanical Permit Units 1 1 4 1 4 1 1 Operator: AMB Printed By: AMB Fee Amount $1,268.15 $4.50 $507.26 $1,779.91 Firm: AIR DESIGN INC Phone: (509) 487-4328 Unit Desc NUMBER OF NUMBER OF # OF UNITS NUMBER OF NUMBER OF NUMBER OF NUMBER OF Permit Total Fees: Print Date: Fee Amount $10.00 $12.00 $4.00 $20.00 $40.00 $10.00 $10.00 $106.00 4/21/2006 Project Number: 06001381 Notes: Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/21/2006 Payment Summary: Permit Type Approach Building Permit Mechanical Permit Fee Amount Invoice Amount $50.00 $50.00 $1,779.91 $1,779.91 $106.00 $106.00 Amount Paid $0.00 $0.00 $0.00 Page 3 of 3 Amount Owing $50.00 $1,779.91 $106.00 $1,935.91 $1,935.91 $0.00 $1,935.91 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 4/21/2006 Project Number: 06001381 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/18/2006 Page 1 of 2 Project Information: Permit Use: SFR, GAS HEAT, ON SEWER Setbacks: Front Site Information: Plat Key: Left: Right: Rear: Name: Hidden Valley Contact: Address: C - S - Z: Phone: Group Name: Project Name: VIKING CONSTRUCTION INC 2605 W HAYDEN HAYDEN LAKE, ID 83835 (208) 762-9106 District: East Parcel Number: 55073.1901 Block: SiteAddress: 17219 E MANSFIELD AVE Location:: CSV Zoning: UR -3.5 Water District: Area: 6,949 Sq Ft Urban Residential 3.5 Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Lot: Owner: Name: VIKING CONSTRUCTION INC Address: 2605 W HAYDEN HAYDEN LAKE, ID 83835 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Landuse/Zoning/HE Conditions Sewer Review Permits: edBy: Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Approach Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 Operator: AMB Printed By: AMB Print Date: 4/18/2006 Project Number: 06001381 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/18/2006 Page 2 of 2 Building Permit Contractor: VIKING CONSTRUCTION Firm: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE Phone: (208) 762-9106 HAYDEN, ID 83835 Contractor: AIR DESIGN INC Address: 1807 E FRANCIS AVE SPOKANE, WA 99207 Notes: Mechanical Permit Firm: AIR DESIGN INC Phone: (509) 487-4328 Payment Summary:. Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 4/18/2006 r� Ck none Permit Center 11707 E Sprague Ave, Suite 106 Spokane Va11e-y, 2117A 99296 (509)5$8-00 6 r: . (5' 9)658-0037 row.. . :y D evelop �_=. 1. 4-:^ .2.1.,; aile1'.on r.cor r Residential Construction Permit Application PERMIT 1\TUMBER: t 33'f. ?ERMI T FEE: X,'New Construction o Addition/Remodel o Other: _ccessoIy Bldg ❑ Deck SITE ADDRESS fl C 1 ''� —k3:3J1 ASSESSORS PARCEL, Nati r L=l,3 0 LEGAL DESCRIPTION: t 1-10 L ..t ie6164 Building owner Name: A: Address: :)1 ,!:- 'ky. %.i, VI,j, IA �s City: �i j(\ Zip: CG _,�_' '. Phone: 16, -CitU..L Fax: .1U)--t-k`x1 `Contact Person':.. Name: Phone: Describe the scope of work in detail: Contractor Name: -2,G+„._,0,,N '- Address: Zip: `City: Phone: Fax: Lic No: \\ 1 iltc-t ',..s3 Exp. Date: City Business Lic No: Cost of Project: **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO P AK:Ls (� DIMENSIONS: 36 # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TGO-SIQ. FTG: ( boy O�- 214" FLOOR SQ. FTG: �O� 014-7S UNFIN BASEMENT SQ. FTG: t. d K— IMPERVIOUS SURFACE AREA:.2 � › ! ^ FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: t.'ci 3 DECK/COV. PATIO SQ. FTG: 1 29 0 (C_ 30% SLOPES ON PROPERTY: # OF BEDRO M : CONSTRUCTION TYPE: M Cw IIees, HEAT SOURCE:SEWER 4S I OR SEPTIC? S (0 e7 2 DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signatures l\ -'r14 '�'t tbu Method of Payment: (Faxed permit ap ❑ Cash ❑ Check Bankcard #: Date 141(31C/(G cations will only be accepted with major bankcard) ❑ Mastercard ❑ VISA Expires: VIN'.`: ❑ Other Authorized Signature: REVIS5D 82512305 Sii&cane 11707 E Sprague Ave Suite 105 + Spokane Valley WA 99206 509.921.1000 + rax. 509.921.1003 + cityhali®spokanevailey.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor pians, foundation pians With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information Permit Center Spokane 11707 E Sprague Ave, Suite 106 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 Community Development www.spokanevallev.org.com Mechanical Permit Application .Valley PERMIT_<< 1uM ER ' PERMIT EEE: ❑ Commercial 1(Residential SITE ADDRESS \1 )-\\\jVL1i`J+ Building owner Name: Y 1 Y Q xi: l (10 11 (‘ 1 on ; 0 Phone: f:416.- L 1(1, Fax flifr',._ '')(4),-45-r,---1 Address: 4 -LP la-) , 4 V i,11 `t' City itk Igo n State I`t Zip VP)• (=i Contractor Name: Ott/ L ) .- rk,trl Phone: Fax: Address: City State Zip License No: City Business License No: Contact Name: Phone: • • DESCRIPTION OF WORK # OF UNITS X COST 1 2 FUEL BURNING APPLIANCE FUEL BURNING APPLIANCE Equal to or less than 100,000 More than 100,000 X $12.00 X $15.00 3 4 UNLISTED APPLIANCE (Additional Fee) UNLISTED APPLIANCE (Additional Fee) Equal to or less than 400,000 More than 400,000 X $50.00 X $100.00 5 USED,APPLIANCE (WSEC min. AFUE rating) Equal to or less than 400,000 X $50.00 6 USED APPLIANCE (WSEC min. AFUE rating) More than 400,000 X $100.00 7 BOILER/REFRIGERATION 1 - 100M BTU X $12.00 8 BOILER/REFRIGERATION 101 - 500M BTU X $20.00 9 BOILER/REFRIGERATION 501 - 1,000M BTU X $25.00 10 BOILER/REFRIGERATION 1,001 - 1,750M BTU X $35.00 11 BOILER/REFRIGERATION More than 1,750M BTU X $60.00 12 GAS LOG, GAS INSERT, GAS FIREPLACE X $10.00 13 RANGE X $10.00 14 DRYER X $10.00 15 FUEL BURNING WATER HEATER X $10.00 16 MISC. FUEL BURNING APPLIANCE 17 18 GAS PIPING (each outlet) DUCT SYSTEMS 1\ X $10.00 X $1.00 X $10.00 19 VENTILATING FANS l4 x $10.00 20 AIR HANDLER (DOES NOT include ducting) Equal to or less than 10,000 CFM X $12.00 21 22 AIR HANDLER (DOES NOT include ducting) EVAPORATIVE COOLERS Greater than 10,000 CFM X $15.00 X $10.00 23 TYPE I HOOD X $50.00 24 TYPE II HOOD X $10.00 25 HEAT PUMP/AIR CONDITIONER 0-3 TON X $12.00 26 AIR CONDITIONER 3-15 TON x $20.00 27 AIR CONDITIONER 15-30 TON X $25.00 28 AIR CONDITIONER 30-50 TON X $35.00 29 AIR CONDITIONER More than 50 TON X $60.00 30 LPG STORAGE TANK X $10.00 31 WOOD OR PELLET STOVE/INSERT X $10.00 32 WOOD STOVE - FREE STANDING X $25.00 33 REPAIR & ADDITIONS X $15.00 34 VENTILATION SYSTEMS X $12.00 35 VENTILATION MECHANICAL EXHAUST X $12.00 36 INCINERATOR - RESIDENCE X $19.0o 37 INCINERATOR - COMMERCIAL X $22.00 METHOD OF PAYMENT: ['CASH ❑ CHECK ❑ VISA 0 MC CARD #: AUTHORIZED SIGNATURE: DATE: EXPIRES: SUBTOTAL PROCESSING FEE $35.00 TOTAL PERMIT FEE DUE: REVISED 8/26/05 WCommuriity Development • Spo rte Val ley Permit h.ente2 j 7 707 E Spra,ue Ave. Suite 106 r Spokane Valle -v. A)t' =; 99206 (509168$_0036 FAA: '50)58-003' ' w.spokanevalley.orR Approach Permit Application PFP M t T NVIVE • PERMIT FEE. PROJECT ADDRESS n.1C‘ CT' .� "- START DATE ANTICIPATED COMPLETION DATE Building Owner: Contractor: Narne: Y Ike f Address: 1A1) City: deal. ATA State: Zip: '3b`3 Phone: �OiS'71a `�\f )l Fax: (kfi5 = llor�'u�Cl Contact Person Name: Phone:�'s_`lco-N-c11C)( PROJECT DESCRIPTION (Provide site sketch) Residential Driveway Existing Curb Gutter Culvert Installation Other Conditions Narne: iYv) Address: City: State: Zip: Phone: Fax: Contractor Lic No: v IK I geme.exp Date: City Business Lic. No: Cotntnercial/Industrial Driveway Rural Road Section Sidewalk Repan -/Construction Bond/Insurance certification must be on file with the city. DISCLAIMER The permittee verifies, acknowledges and agrees by their signatures that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or app -oval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may he required to he submitted, and subsequently approved before this application can he processed. Signature Da\VN-- Date MMeibad of Payment: ❑ Cash ❑ Check ❑ Mastercard ❑ VISA Bankcard #: Expires: VIN #: •uthorized Sig -nature: REVISED 2."9JOE ~.. ---• •-.. --• •,- ' .L1 !•'.. I 1,,\;-!" ••• "\.1-* • !! • : •1, ' •H! h ,! !! .!1.11i!,' ; 1'1 c-!•!!!!--.1 It!! !!!-!!!!!!!!„•11 _ '.., ,.1 1,,,,;,!.!..!:!!,!:!,,,c; ,,,5.-‘,.:!•:--2,:-..!,! 1!!!‘.: , 1.!...:,!!!!-!!!!—, .!: '7•: '7 -0!:-.. ' ' • - ' • " I I - ! • TT: • I' I . , , • i! I 1,1111t--,1 it: - !•'• "'- 1-! ' , r• - !"•!,!!!": Cyl,J111, r, I.!!!•!: • 1 --•-.11111111;117 ..•:!.111!!'111tt'!' P:t mr111 • SIVE PL1_,Mi 1 SCALE: 1 "= 20'- 0" LOT 1 BLOCK 1 HIDDEN VALLEY SPOKANE VALLEY, WASHINGTON 0 • UNDER GROUND POWER PLANNING DEPT. APPROVED BY: •• 4 i 131 610 69.48' SLOPE 5% IN 10' 54'-6" 8'-11 13/16" SP T ii EN -iplR Y' DRIVEWAY. CONC. PORCH AND SIDEWALK 10' UTILITY EASEMENT 13' BORDER EASEMENT WALKWAY 69.5' SWALE CURB_ INIANSPEEDO AVE. GROWN OF STREET This site plan is being submitted for the purpose of obtaining a building permit and is a true and correct representaion of the propsal. All known property line/dimensions, curb lines, structures and easements have been identified. Also indicated are wetlands, bodies of water, steep slopes or other critical areas. Signed: e vrN Date: 'T"/LZ/OL WATER M ORMAND CLARINGTON FIGURE 2a GARAGE NARROW WALL BRACING METHOD WITHOUT HOLD-DOWNS (two segments shown) OuTsi c Elevation Max. height 10' / 3" x 11-1/4" min. header (built-up, solid sawn, glulom, etc.) "" bro� 6' to 18' (finished width) 4 } 'N Min. (2) 2x4 typ. 4h 0q ' Fasten sheathing lo header with Bd common nails in 3" grid pattern as shown and 3" o.c. in all framing (studs and sills) typ. If panel splice is needed it shall occur within 24" of mid -height. Blocking is required. If 2x blocking is used it must be stitch nailed 1. with one row of 16d sinkers at 3" o.c. iar 16" min. for 8' height 18" min. for 9' height 20" min. for 10' height vN� vM Min. 2"x2"x3/16" plate washer Inside Elevation Anchor bolt per code Fasten top plate to header with two rows of 16d sinkers of 3" o.c. typ. 1000 lb header strap opposite sheathing as shown (see Section A -A) typ. 2x framing N Min. (2) 2x4 typ. See typ. corner framing detail 1/2" dia. anchor bolt with 7" min. embedment i *r and 2" x 2" x 3/16" plate washer, typ. Jr • 8 --t Side Ekric;ibn Sheothing filter if needed 16d sinker nails in 2 rows a 3" o.c. 1000 Ib header strap 3/8" min. thickness wood structural panel sheathing Not to scale 4 © 2003 APA — The Engineered Wood Association 1 E' ? E Lr W A Y To B LJ I L f & L THE W k" A EZ 0 ti F Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Clarington Ormand Lot 1 Blk 1 Hidden Valley Spokane Valley, Washington Conditioned Floor Area Conditioned Building Volume Weather Station Spokane CO Component Performance, Zone 2, Other: Viking Construction W. 2605 Hayden Ave. Hayden, Idaho 83835 2468 19744 Heating System Size Ducts are located in unconditioned space. ❑ Equipment size over design load 100% Btu/hour output KW Code Target Values Area UA Vertical Glazing U = 0.400 Overhead Glazing Installed in Attics U = 0.580 Overhead Glazing Installed in Vaults U = 0.580 Doors U = 0.200 Attics U = 0.031 Single Rafter/Joist Vault U = 0.034 Wall (above grade) U = 0.062 Floors U = 0.029 Slab F = 0.540 Below Grade Interior 2' depth, wall U = 0.043 2' depth, slab F = 0.690 3.5' depth, wall U = 0.041 3.5' depth, slab F = 0.640 7' depth, wall U = 0.037 7' depth, slab F = 0.570 Below Grade Exterior 2' depth, wall U = 0.061 2' depth, slab F = 0.600 3.5' depth, wall U = 0.057 3.5' depth, slab F = 0.570 7' depth, wall U = 0.050 7' depth, slab F = 0.420 370 148.1 0 0.0 0 0.0 38 7.6 1482 45.9 0 0.0 2286 141.7 496 14.4 0 0.0 0 0.0 0 0.0 441 18.1 126 80.6 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Target UA Totai If the Proposed UA <_ The Target the UA requirements are meet. Check other code requirements 456.4 40,021 11.7 Proposed Design Values Area UA 266 133.0 0 0.0 0 0.0 38 2.6 1482 45.9 0 0.0 2390 148.2 496 25.3 0 0.0 0 0.0 0 0.0 441 18.1 126 80.6 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Proposed UA Total Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 453.8 4/12/2006 1 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Vertical Glazing Plan Component Glazing U Width Height Qt. Feet Inch Feet Inch Area UA - ........, .r....... --- _.. 2gl vinyl,clear 1/2" space v - - - 10-6c 0.500 2 4 4 32.0 16.0 -21 steel insulated V 291 vinyl,clear 1/2" space V 10-6c 0.500 1 6 8 6 6 39.0 19.5 0 291 vinyl,clear 1/2" space v 10-6c 0.500 1 6 0.0 6 10 41.0 20.5 0.000 291 vinyl,clear 1/2" space v 10-6c 0.500 5 4 0.0 3 6 70.0 35.0 2gl vinyl,dear 1/2" space v 10-6c 0.500 1 8 5 0 40.0 20.0 2g1 vinyl,clear 1/2" space v 10-6c 0.500 1 2 0 6 12.0 6.0 2g1 vinyl,clear 1/2" space v 10-6c 0.500 1 5 6 2 11.0 5.5 2gl vinyl,clear 1/2" space V 10-6c 0.500 1 6 3 6 21.0 10.5 0.0 0.0 V 0 0.000 0.000 0.0 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V_ V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 Exterior Doors Plan ID p -1/p p -1/p Component Description Ref. Door U Sum of Area and UA 266.0 133.0 Width Height Qt. Feet inch Feet In`h Area UA -21 steel insulated v Custom 0.070 1 3 68 20.0 1.4 -21 steel insulated V Custom 0.070 1 2 8 6 8 17.8 1.2 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 If exempt door is selected, must be <_ 24 SF. Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 37.8 2.6 4/12/2006 2 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Overhead Glazing Installed in Attic Ceilings Plan ID Component Ref. Glazing U Width Height Qt. Feet Inch Feet Inch Area UA r V 0 0.000 0.000 v 0 0.000 0.0 0.0 0.0 v 0 0.000 0.000 0.000 0.0 0.0 0.0 v 0 0.000 0.000 0.0 0.0 0.0 V 0 0.000 0.000 0.0 0.0 0.0 V 0 0.000 0.000 0.0 0.0 0.0 V 0 0.000 0.000 0.0 0.0 0.0 V 0 0.000 0.000 0.0 0.0 Overhead Glazing Installed in Vaulted Ceilings Plan ID Component Description Ref. Glazing U Sum of Area and UA 0.0 0.0 Width Height Qt. Feet Inch Feet Inch Area UA Attics Plan Component ID Description R38 blown Attic STD baffled Vaults Plan ID Ref. Attic U 10-7 0.031 0 0.000 v 0 0.000 0 0.000 Component Description Ref. Vault U V 0 0.000 v 0 0.000 0.0 0.0 0.000 V 0 0.000 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 Attics Plan Component ID Description R38 blown Attic STD baffled Vaults Plan ID Ref. Attic U 10-7 0.031 0 0.000 v 0 0.000 0 0.000 Component Description Ref. Vault U Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 Area UA 1482.0 45.9 0.0 0.0 0.0 1482.0 45.9 Area UA 0.0 0.0 0.0 0.0 0.0 0.0 4/12/2006 3 of 6 0 0.000 v 0 0.000 v 0 0.000 V 0 0.000 Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 Area UA 1482.0 45.9 0.0 0.0 0.0 1482.0 45.9 Area UA 0.0 0.0 0.0 0.0 0.0 0.0 4/12/2006 3 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Walls (Above Grade) Plan Component ID Description R19 cavi Ref. Wall U .y+RO foam STD 2X6W Lap V 10-5 0.062 V 0 0.000 0.051 v 0 0.000 0.000 0 0.000 Floor (over crawl or exterior) Plan Component ID Description Ref. Floor U 230 Wood Joist Exposed V 10-4A 0.051 230 Wood Joist Exposed V 10-4A 0.051 0.000 V 0 0.000 v 0 0.000 Slab on Grade (less than 2 feet below grade) Plan Component ID Description V Ref. Slab F 0 0.000 0 0.000 0 0.000 0 0.000 Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) Area UA 2390.0 148.2 0.0 0.0 0.0 2390.0 148.2 Area UA 14.0 0.7 482.0 24.6 0.0 0.0 496.0 25.3 Slab Length UA 0.0 0.0 0.0 0.0 0.0 0.0 4/12/2006 4 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Below Grade Wall: 2 foot depth, insulated on the interior Plan Component ID Description Ref. Wall U Wall Area Wall UA Slab F Slab Slab Length UA V 0 0.000 18.1 0.0 0.000 80.6 0.0 v 0 0.000 0.000 0.0 0.000 0 0.0 V 0 0.000 0.0 0.000 0.000 0.0 V 0 0.000 0.0 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the interior Plan ID Component Description R19 Batt 3.5 depth Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA 10-1 0.041 441.0 18.1 0.640 126.0 80.6 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the interior Plan ID Component Description 441.0 18.1 126.0 80.6 Wall Wall Wall Slab Slab Slab Ref. U Area UA F Length UA 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 4/12/2006 5 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels ' Below Grade Wall: 2 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U Wall Wall Slab Slab Slab Area UA F Length UA Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA w 0 0.000 0.000 0.0 0.000 0 0.0 w w 0 0.000 0.0 0.0 0.000 0.0 0.0 w 0 w 0 0.000 0.000 0.0 0.000 0.0 0.0 0 0.000 w 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the exterior Plan Component ID Description V V V Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA 0 0.000 0 0.000 0.000 0.0 0.000 0 0.0 w 0 0.000 0.0 0.0 0.000 0.0 0.000 w 0 0.000 0.000 0.0 0.000 0.000 0.0 0.0 w 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the exterior Plan Component ID Description V V V Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 4/12/2006 6 of 6