Loading...
2006, 04-21 Permit App: 06001385 ResidenceProject Number: 06001385 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/21/2006 Page 1 of 3 Project Information: Permit Use: SFR, GA HEAT, ON SEWER Contact: VIKING CONSTRUCTION INC Address: 2605 W HAYDEN C - S - Z: HAYDEN LAKE, ID 83835 Setbacks: Front Left: Right: Rear: Phone: (208) 762-9106 Group Name: Site Information: Project Name: Plat Key: Name: Hidden Valley District: East Parcel Number: 55073.1902 Block: Lot: SiteAddress: 17307 E MANSFIELD AVE Location:: CSV Owner: Name: VIKING CONSTRUCTION INC Address: 2605 W HAYDEN HAYDEN LAKE, ID 83835 Zoning: UR -3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: 6,500 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Building Plan Review Originally Released: 4/20/2006 By: TMELBOU Landuse/Zoning/HE Conditions Sewer Review Originally Released: 4/19/2006 By: CJJANSSE Permits: Operator: AMB Printed By: AMB Print Date: 4/21/2006 Project Number: 06001385 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/21/2006 Page 2 of 3 Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Item Description APPROACH -CONST IN ROW Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Description Grn Type 1&2 FAMILY R-3 VB BASEMENT U R-3 VB DECK OPEN R-3 VB GARAGE U-1 VB Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Notes Contractor: AIR DESIGN INC Address: 1807 E FRANCIS AVE SPOKANE, WA 99207 Item Description GAS WATER HEATER GAS APPLIANCE<=100,000BTU GAS PIPING VENTILATING FANS RANGE HOOD -TYPE II Approach Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 Units Unit Desc Fee Amount 1 NUMBER OF $50.00 Permit Total Fees: Building Permit $50.00 Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 This Application: Total Project: Sq Ft Valuation Sq Ft Valuation 1,166 $100,707.42 1,166 $100,707.42 647 $9,705.00 647 $9,705.00 28 $420.00 28 $420.00 633 $12,027.00 633 $12,027.00 Totals: 2,474 $122,859.42 2,474 $122,859.42 Units Unit Desc 1 1 1 SELECT SELECT SELECT Permit Total Fees: Mechanical Permit Fee Amount $1,122.55 $4.50 $449.02 $1,576.07 Firm: AIR DESIGN INC Phone: (509) 487-4328 Units Unit Desc 1 NUMBER OF 1 NUMBER OF 3 # OF UNITS 4 NUMBER OF 1 NUMBER OF 1 NUMBER OF Operator: AMB Printed By: AMB Permit Total Fees: Print Date: Fee Amount $10.00 $12.00 $3.00 $40.00 $10.00 $10.00 $85.00 4/21/2006 Project Number: 06001385 Notes: Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/21/2006 Payment Summary: Permit Type Approach Building Permit Mechanical Permit Fee Amount Invoice Amount $50.00 $50.00 $1,576.07 $1,576.07 $85.00 $85.00 $1,711.07 $1,711.07 Amount Paid $0.00 $0.00 $0.00 Amount Owing $50.00 $1,576.07 $ 85.00 $0.00 $1,711.07 Page 3 of 3 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 4/21/2006 Project Number: 06001385 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/18/2006 Page 1 of 2 Project Information: Permit Use: SFR, GA HEAT, ON SEWER Setbacks: Front Site Information: Plat Key: Left: Right: Rear: Contact: VIKING CONSTRUCTION INC Address: 2605 W HAYDEN C - S - Z: HAYDEN LAKE, ID 83835 Phone: (208) 762-9106 Group Name: Project Name: Name: Hidden Valley District: East Parcel Number: 55073.1902 Block: Lot: SiteAddress: 17307 E MANSFIELD AVE Location:: CSV Zoning: UR -3.5 Water District: Area: 6,500 Sq Ft Urban Residential 3.5 Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Owner: Name: VIKING CONSTRUCTION INC Address: 2605 W HAYDEN HAYDEN LAKE, ID 83835 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Released By: Landuse/Zoning/HE Conditions Sewer Review Permits: Released By: Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Approach Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 Operator: AMB Printed By: AMB Print Date: 4/18/2006 Project Number: 06001385 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/18/2006 Page 2 of 2 Building Permit Contractor: VIKING CONSTRUCTION Firm: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE Phone: (208) 762-9106 HAYDEN, ID 83835 Mechanical Permit Contractor: AIR DESIGN INC Firm: AIR DESIGN INC Address: 1807 E FRANCIS AVE Phone: (509) 487-4328 SPOKANE, WA 99207 Notes: Payment Summary Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local Laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 4/18/2006 Permit Center Spokane 1: .1. k, N/Ta1j Valley, a•ie" Jv`.ry a �G l3 Residential Construction Permit Application I�I ?ERMIT NL ER : (31( tf 1\T2 TCoact-ruction ❑ Addition/RemodeI o Other: o Deck SITE :ADDRESS 11 C71 f e__ .A..3S7Sc.ORS ? ,P,CEL JO: s? J``' I - 7") . C5\ ') LEGAL L ESCR FTICN: Building owner Name: c:Y u - Name.: \1 JULfCk Address: MAIN FLOC, T Q. FTG: � Address: r U) fit' c \ (;e City: VS` (' ,-\ Zip: e -/-?:?) :S Phone: /1'L'.. LA Fax: DECK/COV. ATIO SQ. FTG: `a Ft. -LI') Li contact Person: Name: Phone: Describe the scope of work in detail: Contractor.. Name: c:Y u - # OF STOP.IE : 'Cr,' -Leve Address: MAIN FLOC, T Q. FTG: � City: Zip: Phone: Fax: Lic No: \' i -i I\CVct` ':i-3 Exp. Date: City Business Lic No: DECK/COV. ATIO SQ. FTG: `a Ft. Cost of Project: **************The following MUST be complete: (write NIA if not applicable)***/ ************* HEIGHT TO PEAK: Zo' - Z " DIMENSIONS: 511'n 9 7 # OF STOP.IE : 'Cr,' -Leve TOTALHP TABLE SPACE: FY-. MAIN FLOC, T Q. FTG: � 2''" FLOOR SQ. FTG: N�/1 UNFIN BA ' T SQ. FTG: ��� + F -F. IMPERVIOUS SURFACE AREA: Z 55g F -f, FINISHED BASEMENT SQ. FTG: VJ&Jr u-7 RAGE Q. FTG: 6 I, DECK/COV. ATIO SQ. FTG: `a Ft. 30% SLOPES ON �/ PROPERTY: (��/7- SEWER OR SEPTIC? Sem i# OF BEDROOMS: CONSTRUCTION TYP : 1C-orxic.,4all T HEAT SOURC Fo-« 4-Y- , DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All :zonstruction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval far any violation of federal, state or local 12Ws., codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. �I ikfeffiod of Payment: (Faxed permit a/7,Diicatior2s will on e accepted with malorbankcarO) ❑ Cash ❑ Check E MastercardI i VISA Bankcard Expires: V!Nt Authorized Signature,: _ .c.1SEE 5 25 23::5 ),(1(310&' ❑ Other Siokane4.5000 MtI ley 11707 E Sprague Ave Suite 105 4 Spokane Vathy WA 99206 5019.92 j.1ono 4 ray_ 50.921.i00 i.cityhaU®sp.Jkane'aHey. . rg Residentiai Plan Subrnittal M i ramums Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature., and date. Two sets of plans including Site Plan, elevations, poor plans, foundation plans With details, roof plan, framing plans & details. Show the height of any proposed buildings or accessory structures. Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Roam (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. All braced wall panel types: show locations and details of installation, including engineered design. Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. Smoke detector locations 22" X 30" attic access location ,� � x 3a►, d " crawl space access: .(7i' One-hour separation detail: between house and garage Floor framing details: Joist type, size, .spacing and installation details Roof framing plan and details G1% Furnace and hot water heater location. C9� AN header locations: type, size, and connections i7 Foundation plan Insulation infor� �,aiin,-i L. ' I • • ; 1 '• • I !Hi - - — . • ,••••. A ; 1'1 t!..1 It I If , it i!1 it ".'!-.• ••iit .• • ! • •-••' 9wit • _1 1:1;•,111: !t, :i!: '1 • .:-. • . I -L• •.- • • •-[!,11'r t! _f 1_ I_ .1 (_!!:,1 1••-• • 'I LI!' • • • •-• ' i•T-.11.: I .1.. • : . 112 .-!..11-• -2,':=•",•.2,11.1:-.=,"1*,.1-•..::•i'.. • I -.11'. 1 I \'‘-'• '•'• 110,199,1,1'111!1 '9,'-‘11,9111", ;_•tit1111131!\,,' 1 s.)1(.•6 Sgokan e� .000 Valley Community Development Permit Center 11707 E Sprague Ave, Suite 106 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 Nww.spokanevalley.orc.com Mechanical Permit Application ❑ Commercial 410 SITE ADDRESS 11 3I -1 I PERMIT:IEiMBER. <= PERNIIT FE °Residential Building owner Name: X 111 I XT �t i� 1'1'1. ('A- 1 T1� \(, Phone: n ('((&-'1 t-) "i i it: Fax ,l(' - --)L4-(..6(7,-7 Address: ,-1.v_Cf-) t )(U r. t1 !-i ,f' City @ is )rl, State 'TO Zip ?f ?(A �')S Contractor l `Name: �l� ��,�f1 tl Phone: Fax: Address: City State Zip License No: City Business License No: Contact Name: Phone: • • DESCRIPTION OF WORK # OF UNITS X COST = TOTAL AMOUNT 1 FUEL BURNING APPLIANCE Equal to or less than 100,000 X 812.00 2 FUEL BURNING APPLIANCE More than 100,000 X $15.00 3 UNLISTED APPLIANCE (Additional Fee) Equal to or less than 400,000 X $50.00 4 UNLISTED APPLIANCE (Additional Fee) More than 400,000 X $100.00 5 USED APPLIANCE (WSEC min. AFUE rating) Equal to or Tess than 400,000 X $50.00 6 USED APPLIANCE (WSEC min. AFUE rating) More than 400,000 X $100.00 7 BOILER/REFRIGERATION 1 - 100M BTU X $12.00 8 BOILER/REFRIGERATION 101 - 500M BTU X $20.00 9 BOILER/REFRIGERATION 501 - 1,000M BTU X $25.00 10 BOILER/REFRIGERATION 1,001 - 1,750M BTU X $35.00 11 BOILER/REFRIGERATION More than 1,750M BTU X $60.00 12 GAS LOG, GAS INSERT, GAS FIREPLACE X $10.00 13 RANGE X $10.00 14 DRYER X $10.00 15 FUEL BURNING WATER HEATER X $10.00 16 MISC. FUEL BURNING APPLIANCE X $10.00 17 GAS PIPING (each outlet) X $1.00 18 DUCT SYSTEMS X $10.00 19 VENTILATING FANS X $10.00 20 AIR HANDLER (DOES NOT include ducting) Equal to or less than 10,000 CFM X $12.00 21 AIR HANDLER (DOES NOT include ducting) Greater than 10,000 CFM X $15.00 22 EVAPORATIVE COOLERS X $10.00 23 TYPE 1 HOOD X $50.00 24 TYPE II HOOD X $10.00 25 HEAT PUMP/AIR CONDITIONER 0-3 TON X $12.00 26 AIR CONDITIONER 3-15 TON X $20.00 27 AIR CONDITIONER 15-30 TON X $25.00 28 AIR CONDITIONER 30-50 TON X $35.00 29 AIR CONDITIONER More than 50 TON X $60.00 30 LPG STORAGE TANK X $10.00 31 WOOD OR PELLET STOVE/INSERT X $10.00 32 WOOD STOVE - FREE STANDING X $25.00 33 REPAIR & ADDITIONS X $15.00 34 VENTILATION SYSTEMS X $12.00 35 VENTILATION MECHANICAL EXHAUST X 812.00 36 INCINERATOR - RESIDENCE X $19.00 37 INCINERATOR - COMMERCIAL x _ 822.00 METHOD OF PAYMENT: ❑CASH ❑ CHECK ❑ VISA ❑ MC CARD #: AUTHORIZED SIGNATURE: DATE: EXPIRES: SUBTOTAL PROCESSING FEE 835.00 TOTAL PERMIT FEE DUE: REVISED 8/26/05 \''. ley ^ ' i De .�'Ji?li.�U:.n:t�' t elOpcmeni. :C 1 i Cen Lei 07 _ . >,__ ,vt.. S'.._ Spokane C1iei, 1I` ?9206 (5()9 )6Fg_rin.F rn}r.,crc!,c,cc_903? w-ww. s-ookanev all t . or2 Approach Pers it Application PROJECT ADDRESS VJIU-1�r l� START DATE PERMIT . E-A. ANTICIPATED C,OlVd'LL" 1 i `Ji`J DATE E Building Oiler: Contractor: Name: V aktrc Address: AS kx') City: Iea.L\011130 Phone: .0(6- lu.,).... q k o State: Zip:b Contact Pcrson Fax: (k)?) = l lsy-1-`uW Name: Phone: ; _-� ) _cuc)L PROJECT DESCRIPTION (Provide site sketch) Residential Driveway Existing Curb &. Gutter Culvert Installation Other Conditions Name: z(--1, jr(v) Address: City: State: Zip: Phone: Fax: Contractor Lic No: v i K i t Ac tc,'sCX` i Exp Date: City Business Lic. No: Commercial/Industrial Driveway Rural. Road Section Sidewalk Repan -/Construction Bond/Insurance certification must be on file with the city. DISCLAIMER The permittee verifies, acknowledges and agrees by their signatures that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Perrot inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional. information may be required to be submitted, and subsequently approved before this application can be processed. Signature t Date Metricd of Paymenc. VISA Cash I I C,heci: ❑ Mastercard❑ VISA • utho_ized Signature: EV SEC "atce *lane .000Valley Ol0- 143D DEPARTMENT OF COMNf[-r.''z i Y DEVELOPMENT CURRENT PLANNING ADMINISTRATIVE EXCEPTION APPLICATION AND DETERMINATION PART I \' APPLICANT: V 1 V--.106 t 70--ZPS712-4-AC-T1®f3 MAILING ADDRESS: tR"[ DE.13 I oo. CITY: ►atq,I/(%� � STATE: J �c00 ZIP: 83b 3S - PHONE: (HOME) 2.05 -/C:0 -"Ci k (WORK) (CELL) NOTE: IF APPLICANT IS NOT THE OWNER, INCLUDE WRITTEN OWNER AUTHORIZATION FROM THE LEGAL OWNER BELOW LEGAL OWNER: MAILING ADDRESS: CITY: STATE: ZIP: PHONE: (HOME TAX PARCEL No: r LEGAL DESCRIPTION: lam'! - 2 4/ Fb %A ►'- VA L.C.. �``Y PS trk ► tJ (--rc) t3 (WORK) (CELL) STREET ADDRESS OF SITE: L4C.kL- 1 14 ic=1den ValIe SECTIONS) -ZONINGCLASSIFICATION: "" `.. COMPREHENSIVE TYPE OF ADMINNISTRATIVE EXCEPTION REQUESTED' TOWNSHIP RANGE PLAN CATEGORY: - l �D Env l I EXPLAIN REASON FOR REQUEST: 'i- i t 113 . Cop C( 0 'STAtR. ' rcop mc -T- . " C 11 S ► IvL� �-( APPLICABLE SEC LIONS) OF ZONING CODE: NOTE: A SITE PLAN AND SUPPORTIVE DOCUMENTS SHALL BE LNCLUDED WITH THIS APPLICATION PART 11 LEGAL OWNER SIGNATURE (Signature of legal owner or representative as authorized by legal owner) n l`) U.\-QJ�.D L U\ -DO , (print name) SWEAR OR AFFIRM THAT THE ABOVE RESPONSES ARE MADE TRUTHFULLY AND TO THE BEST OF MY KNOWLEDGE. I FURTHER SWEAR OR AFFIRM THAT I AM THE OWNER OF RECORD OF THE AREA PROPOSED FOR THE ABOVE IDENTIFIED LAND USE ACTION, OR, IF NOT THE OWNER, ATTACHED HEREWITH IS WRITTEN PERMISSION FROM THE OWNER AUTHORIZING MY ACTIONS ON HIS/HER BEHALF. ADDRESS: L . t }. Dia) Pore_- PHONE: 3439) g.— Q i0 L0 ''{ bn ZIP: t?)c(t5 (Signature 4- -/3 -0 6 (Date) NOTARY (For Part II above) STATE OF WASHINGTON ) ss: COUNTY OF SPOKANE ) SUBSCRIBED AND SWORN to before me this 11)1 -\day of NOT i'B Y ,....._... ''1/// NOTARY SIGNATURE i k ' Notary Public �in and for the State of Vt•Lasiftitagt-ea ' E,. ®l = Residing at: l 1; --rd lL2tl U t � l'��, • My appointment expires: CA , 201(4 DATE SUBMITTED: FEE: PART III (To be completed by the Planning Staff) ` RECEIVED BY:a./ CV V FILE N3CD co O.: �{ ' O� -O PART FV Under Section 14.412.041 of the City Zoning Code, any person aggrieved by this administrative determination has the right to appeal this administrative decision to the City of Spokane Valley Hearing Examiner. An appeal must be filed by submitting the appropriate appeal application together with the required fee to the Department of Community Development Current Planning, within fourteen (14) calendar days after the decision is issued. Upon receipt of a complete appeal application, a public hearing will be scheduled. For information or questions, please call (509) 921-1000 Rev 6/03 DETERM]INA T ION File No: AE -(J - _C The Department of Community Development finds that the information provided by the applicant and required compliance with the City of Spokane Valley Zoning Code and all other development regulations, does / does not adverse affect on the adjacent properties nor the public's general health, safety and welfare. The Department of Community Development approves / denies this "Administrative Exemption" as conditioned below, for the property described in Part I, pursuant to Sections 14.506.000 and 14.506.020 of the Zoning Code. This administrative exception is subject to the following conditions of approval: , 1) This administrative decision shall apply to the subject property indefinitely and may be transferred to future property owners, heirs or any successor in interest to the property subject to the conditions of approval contained herein. 2) The applicant and property owner shall comply with all requirements and regulations of the Zoning Code. 3) The applicant shall comply with all applicable development regulations and standards. 4) The applicant and property owner shall comply with the following additional conditions: This administrative exception is hereby approved this 1 q 11 day of p { �V -, , 20 O L Approved S)Cl-��— Title: N.A.t ,CiR1,151 Under Section 14.412.041 of the City Zoning Code, any person aggrieved by this administrative determination has the right to appeal this administrative decision to the City of Spokane Valley Hearing Examiner. An appeal must be filed by submitting the appropriate appeal application together with the required fee to the Department of Community Development Current Planning, within fourteen (14) calendar days after the decision is issued. Upon receipt of a complete appeal application, a public hearing will be scheduled. For information or questions, please call (509) 921-1000 Rev 6/03 l �O�{ OMB 17;*41al —E� pt,�►NN�NG LOT z BLOCK 1 HIDDEN VALLEY BY* DATE: 11 �1 ADMINISTRATIVE EXCEPTION REQUESTED SETBACK C5� )'-6/ 54'-0" LOT AREA 6500 Sq. Ft. 65.00' This site plan is being submitted for the purpose of obtaining a building permit and is a true and correct representaion of the propsal. All known property line/dimensions, curb lines, structures and easements have been identified. Also indicated are wetlands, bodies of water, steep slopes or other critical areas. Signed: Josh Goodson Date: 4-1 2-06 5'-6" CONCRETE PATIO SLAB ON GRADE PROPERTY LINE RAISED CONCRETE STOOP AND STAIRS 2' TYP. ENCROACHMENT ALLOWANCE SLOPE SV. IN Io' CONC. PORCH AND SIDEWALK PROPERTY LINE 20' MIN. FRONT SETBAC FROM BORDER EASEMENT 10' UTILITY EASEMENT =DRIVEWAY: WANR SEWER 13' BORDER EASEMENT SIDEWALK :;`:i, SWALE 41)._ __EZDEEKX.LINE 65.00' /NUER a4ROUND ' /OWER • 00 N CURB BIrANSFFELDD AVE, CROWN OF STREET KAYSER / EAGLE 'SW' SIMPSON UPLIFT STRAP 1,800 POUNDS ✓~iii 1 • BnlnannnaU, nri112 ►=�f.121 T111111ln=11111,1210 "dalai,vilaiiiiaa, .-d•. . 0.• .D, a .•dr .• •. d• .• .• . .. •a ▪ •• ••a D•. •. d' •. •.•dz . .MI .db• •• • . 0...•.. • • •.•• .•, •I .•b.. .•D•a .•da .•d•. .•b -..•da TWO ANCHOR BOLTS INSTALLED IN ACCORDANCE WITH FIGURE R403.1(1) SHALL BE PROVIDED IN EACH PANEL. ANCHOR BLOTS SHALL BE PLACED AT PANEL QUARTER POLNTTS N iAX. HEIGHT 10'- 0" \ \-\-\\J, 8" MI . WIDTH 7/16" OSB SHEATHING 3/8" MLN. NAILED WITH Sd COMMON OR GALVINIZED BOX NAILS IN ACCORDANCE WITH TABLE R6023(1) AND BLOCKED AT ALL WOOD STRUCTURAL PANEL SHEATHING EDGES. 2 1 E BACK •CHSTRAP WITH A STUD RECOMMENDED HOLD IN r FROM EDGE OF BP.ACING PANEL - � iJ�p' • . 7111111 1221 mGa 12i' • N111112 a 1122a 11101TamNm11121 N11lualr ��11aaall :CII cEssa .• d•. .d•. . d% •. . d•. a' .�L . D•i . bx . •. . d••..6% .d•. % . dti . 0% d% . 1+% . d•. . b•. ..6%.d•a . • . . . . . . .•. . . . • •. . 0% b -a . d% . 0% . 0.6 . 0% . .0% . d% .•. IN FIRST STORY OF TWO-STORY BUILDINGS, SHALL HAVE AT LEAST THREE ANCHOR BOLTS, PLACED AT ONE-FIFTH POINTS SIMPSON UPLIFT STRAP 3,000 POUNDS SCALE: I " = I'- D" A y _,RNA I E BRACIN G ANEL P.1=104 ALTERNATE BFL4CED 'V '.LL PANELS Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels KAYSER EAGLE SW LOT 2 BLOCK 1 HIDDEN VALLEY SPOKANE VALLEY, WASHINGTON Conditioned Floor Area Conditioned Building Volume Weather Station j Spokane CO Component Performance, Zone 2, Other: VIKING CONSTRUCTION INC. W. 2605 HAYDEN AVE. HAYDEN, IDAHO 1833 14664 Heating System Size Ducts are located in unconditioned space.0 Equipment size over design Toad 100%, •I Code Target Values Area UA Vertical Glazing U = 0.400 Overhead Glazing Installed in Attics U = 0.580 Overhead Glazing Installed in Vaults U = 0.580 Doors U = 0.200 Attics U = 0.031 Single Rafter/Joist Vault U = 0.034 Wall (above grade) U = 0.062 Floors U = 0.029 Slab F = 0.540 Below Grade Interior 2' depth, wall U = 0.043 2' depth, slab F = 0.690 3.5' depth, wall U = 0.041 3.5' depth, slab F = 0.640 7' depth, wall U = 0.037 7' depth, slab F = 0.570 Below Grade Exterior 2' depth, wall U = 0.061 2' depth, slab F = 0.600 3.5' depth, wall U = 0.057 3.5' depth, slab F = 0.570 7' depth, wall U = 0.050 7' depth, slab F = 0.420 275 110.0 0 0.0 0 0.0 38 7.6 1182 36.6 0 0.0 1508 93.5 529 15.3 0 0.0 0 0.0 0 0.0 362 14.8 103 65.9 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Target UA Total If the Proposed UA <_ The Target the UA requirements are meet. Check other code requirements 343.8 Btu/hour output KW 29,863 8.7 Proposed Design Values Area UA 231 115.5 0 0.0 0 0.0 38 2.6 1182 36.6 0 0.0 1552 88.5 529 15.3 0 0.0 0 0.0 0 0.0 362 14.8 103 65.9 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Proposed UA Total Copyright 2002, WSUCEEP 02-090 (Version 4) • Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 339.3 4/12/2006 1 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Vertical Glazing Plan Component Glazing II Width Height n+ Feet Inch Feet Inch Area ID Description 2g1 vinyl,clear 1/2" space ''I r ,. 10-6c v 0.500 -... 2 4 2 4 6 32.0 16.0 1.2 2g1 vinyl,dear 1/2" space v 10-6c 0.500 1 4 8 1 6.2 3.1 20.0 1.4 v 10-6c 0.500 1 6 5 30.0 15.0 0.0 2g1 vinyl,clear 1/2" space 2g1 vinyl,clear 1/2" space . v 10-6c 0.500 3 2 6 6 45.0 22.5 0.0 ear 1/2" space � 2g1 vinyl,clear 10-6c 0.500 3 2 6 1 6 11.3 5.6 0.0 v 10-6c 0.500 1 6 6 10 41.0 20.5 0.0 2g1 vinyl,clear 1/2" space V 10-6c 0.500 3 4 3 6 42.0 21.0 2g1 vinyl,clear 1/2" space 2g1 vinyl,clear 1/2" space V 10-6c 0.500 1 5 3 6 17.5 8.8 v i 0 291 vinyl,clear 1/2" space v 10-6c 0.500 1 1 0.0 6 6.0 3.0 0.000 0 0.000 0.0 0.0 0.0 0.0 0.000 v 0 0.000 0.0 0.0 0.0 0.0 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v_ v 0 0.000 0.0 0.0 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 Exterior Doors Plan Component Descri tion Door U Sum of Area and UA 231.0 115.5 Width Height Qt. Feet Inch Feet Inch Area UA IV p p -1/p-21 steel insulated Custom 0.070 1 2 8 6 8 17.8 1.2 p -1/p-21 steel insulated v Custom 0.070 1 3 6 8 20.0 1.4 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 ---- - - 0 0.000 0.0 0.0 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v i 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 0 0.000 0.0 0.0 If exempt door is selected, must be s 24 SF. Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) . Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 37.81 2.6 4/12/2006 2 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Overhead Glazing Installed in Attic Ceilings Plan Component ID Description Ref. Glazing Width Height U Qt. Feet inch Feet inch Area UA v 1 0 0.000 0.000 0.031 0.000 0 0.000 0.0 0.0 vi 0 0.000 0.000 0.000 ' v 0.0 0.0 0.0 0 0.000 0.000 0.0 0.0 V 0 0.000 0 0.000 0.0 0.0 v 0 0.000 0 0.000 0.0 0.0 0.0 0 0.000 0 0.000 0.0 0.0 0.0 0 0.000 0 0.000 0.0 0.0 Overhead Glazing Installed in Vaulted Ceilings Plan Component ID Description Attics Plan ID Component Description Glazing Ref. U Sum of Area and UA 0.0 0.0 Width Height Qt. Feet Inch Feet Inch Area UA Ref. Attic U R38 blown Attic STD baffled 0 0.000 0.031 0.000 0 0.000 0 0.0 0.0 v 0 0.000 0.000 ' v 0 0.0 0.0 V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 0 0.000 0.0 0.0 Ref. Attic U Vaults Plan Component ID Description V Ref. Vault U 0 R38 blown Attic STD baffled 0 10-7 0.031 0.000 0 0.000 0 0.000 v 0 0.000 ' v 0 0.000 Vaults Plan Component ID Description V Ref. Vault U 0 0.000 0 0.000 0 0.000 0 0.000 Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) • Copied by permission from Washington State University Cooperative Extension Eneroy Program. (see copyright restrictions) 0.0 0.0 Area UA 1182.0 36.6 0.0 0.0 0.0 1182.0 36.6 Area UA 0.0 0.0 0.0 0.0 0.0 0.0 4/12/2006 3 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Walls (Above Grade) Plan Component ID Description R21 cavity+RO foam STD 2X6W Lap Floor (over crawl or exterior) Plan Component ID Description R30 vented Joist 16oc Ref. Wall U V 10-5 0.057 0 0.000 0 0.000 0 0.000 Ref. Floor U v 10-3 0.029 Custom 0.000 0 0.000 Slab on Grade (less than 2 feet below grade) Plan ID Component Descripti 0 0.000 Ref. Slab F Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) Area UA 1552.0 88.5 0.0 0.0 0.0 1552.0 88.5 Area UA 529.0 15.3 0.0 0.0 0.0 529.0 15.3 Slab Length UA 0.0 0.0 0.0 0.0 0.0 0.0 4/12/2006 4 of 6 v 0 0.000 V 0 0.000 V 0 0.000 V 0 0.000 Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) Area UA 1552.0 88.5 0.0 0.0 0.0 1552.0 88.5 Area UA 529.0 15.3 0.0 0.0 0.0 529.0 15.3 Slab Length UA 0.0 0.0 0.0 0.0 0.0 0.0 4/12/2006 4 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Below Grade Wall: 2 foot depth, insulated on the interior Plan Component ID Description Wall Wall Wall Slab Slab Slab Area UA F Length UA v 0 0.000 362.0 0.0 0.000 103.0 0.0 v 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 '14 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the interior Plan Component ID Description R19 Batt 3.5 depth Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA v 10-1 0.041 362.0 14.8 0.640 103.0 65.9 Iv 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 '14 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the interior Plan Component ID Description Ref. Wall U 362.0 14.8 103.0 65.9 Wall Wall Slab Slab Slab Area UA F Length UA v 0 0.000 0.0 0.000 0.0 Iv 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) • Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 4/12/2006 5 of 6 Washington State Energy Code: Component Performance Worksheet ' Zone 2, Other Fuels Below Grade Wall: 2 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U Wall Wall Slab Slab Slab Area UA F Length UA Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA 0 0.000 0.000 0.0 0.000 0.000 0.0 v 0 0.000 0.000 0.0 0.000 0.000 0.0 V 0 0.000 0 0.0 0.000 0.0 0.0 r 0 0.000 v• 0.0 0.000 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the exterior Plan Component ID Descriptio Ref. Wall U 0.0 0.0 Wall Area 0.0 0.0 Wall Slab Slab Slab UA F Length UA v 0 0.000 0.0 0.000 0.0 V 0 0.000 0.000 0.0 0.000 0.000 0.0 0.0 V 0 0.000 0.000 0.0 0.000 0.000 0.0 0.0 v• 0 0.000 0.000 0.0 0.000 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the exterior Plan Component ID Descriptio Ref. Wall U 0.0 0.0 Wall Area 0.0 0.0 Wall Slab Slab Slab UA F Length UA Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 4/12/2006 6 of 6 v 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 4/12/2006 6 of 6 2x6 TOP PLATE JOINTS LAPPED MINIMUM OF 48" AND FULL SURFACE GLUED AND NAILED WITH I0d 9 6"o.c. WHILE GLUE WET GLUE OUTSIDE 2x6 TRIM STUD TO EDGE OF VERTICAL FLAT 2x8 AND NAIL WITH 10d 9 6"o.c. WHILE GLUE WET FULL SURFACE ALL VERTICAL 2x8's AT EACH END OF OPENING TO LAPPED HEADER (WITH BRUSH OR ROLLER) AND NAIL WITH 10d m 2"o.c. E.W. WHILE GLUE WET VERTICAL FLAT 2x8 (TYPICAL AT BOTH ENDS OF WINDOW OPENING AND CONTINUOUS TO TOP PLATE) NOTCH HEADERS 4"+ THICK TO SNUG FIT VERTICAL 2x8 HEADER SIZED FOR VERTICAL LOADS BY OTHERS BUT NOT LESS THAN 2x10 10 I/4" OUT -TO -OUT WIDTH OFF RF2 DETAIL IS WINDOW RO. + 20Y" (4'-0 MINIMUM) TOP VIEUJ OF OUTSIDE EDGE OF RF2 2x FILLER NOT REQUIRED WHEN 4"+ THICK NOTCHED HEADER FILLS THE lY" SPACE) GLUE INSIDE 2x6 TRIM STUD TO EDGE OF VERTICAL FLAT 2x8 AND NAIL WITH I0d a 6"o.c. WHILE GLUE WET (TYPICAL) MINIMUM 2x8 SILL CROSS PIECE LAPPED AND FULL SURFACE GLUED (WITH BRUSH OR ROLLER) TO VERTICAL FLAT 2x8's AT EACH END AND NAILED WITH I0d e 2"o.c. WHILE GLUE WET HEADERS CAN BE SLOPED HEADERS CAN BE CUT AT MID -SPAN (45 FOR A CATHEDRAL CEILING) AND SPLICED WITH A MINIMUM 2x10 FULL SURFACE GLUED TO BACKSIDE OF HEADERS AT JOINT WHEN WALLS HAVE SPACE ABOVE AND/OR BELOW OPENING FILL WITH 2x6 STUDS e I6 "o.c. 2x6 STUD WALL MINIMUM INSIDE VIEUJ NOTCHING OPTIONAL AT HEADER (STOP AT 2x6 HEAD TRIMMER) 2x FILLERS MATCHING DEPTH OF HEADER AND SILL CROSS PIECE AND FULL SURFACE GLUED AND NAILED TO HEADER AND SILL CROSS PIECE WITH 10d 6 "o.c. E.W. WHILE GLUE IS STILL WET FULL SURFACE GLUE SHEETING ON OUTSIDE FACE OF RF2 AND NAIL WHILE GLUE WET EXTERIOR SHEETING Y" NOMINAL PLYWOOD OR OSB NAILED WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6"o.c. AT ALL EDGES (ALL EDGES MUST BE BLOCKED) AND 12"o.c. AT ALL OTHER SUPPORTS FRAMING LUMBER DFL No. 2 OR BETTER DAP WELDWOOD CARPENTER'S WOOD GLUE PROFESSIONAL GRADE (ALIPHATIC RESIN) OR EQUAL, PROVIDING AVERAGE 2800psI SHEAR (ASTM D-905 BLOCKSHEARS) THIS DETAIL ONLY PER 2000/2003 I$.CJLR.C. (EXPIRES THEREAFTER) LOT 2, !BLOCK I, HIDDEN VALLEY, SPOKANE VALLEY, UJ4 © 14OIT ENGINEERING, INC. (208) 162-8111 DATE: 4/13/06 SCALE: 3/8" = I'-0"