2003, 08-06 Permit App: BLD-03-02163 GaragePERMIT APPLICATION WORK SHEET
SPOKANE VALLEY COMMUNITY DEVELOPMENT
BUILD/NG DIVISION
11707 East Sprague Ave Ste 106
Spokane Valley, WA 99206
Phone: (509)688-0036 Fax: (509)688-0037
REQUIRED SITE INFORMATION
STREET ADDRESS:
90I /v rl-
ASSESSOR'S TAX PARCEL NUMBER(S):
LEGAL DISCRIPTION:
PERMIT DESCRIPTION:
BUILDING PERMIT C CHANGE IN USE Q GRADING CI MANUFACTURED HOME
®RELOCATION
D. SIGN I TENANT
13- OTHER
OWNER / APPLICANT INFORMATION
0OWNER: k,5e// Wa/I,(e
Y
APPLICANT:
PHONE: S 2. i Y 6 S 5' FAX: PHONE: FAX:
s/�'D fcw�
ADDRESS: ! Al
/V(R r- 5 L1 a f C 4', y2/1 ADDRESS:
CITY, STATE, ZIP
CITY,STATE, ZIP
®CONTRACTOR: ® ARCHITECT:
PHONE: FAX: PHONE:
ADDRESS: ADDRESS:
CITY, STATE, ZIP
FAX:
CITY, STATE, ZIP
WA ST CONTRACTOR LICENSE # CONTACT:
PERMIT/BUILDING INFORMATION
COST OF PROJECT:
BUILDING HEIGHT TO PEAK: OCCUPANCY GROUP: 2N0 FLOOR SQ FT:
BUILDING DIMENSION$: /6X 3 CONSTRUCTION TYPE: UNFIN BASEMENT:
NUMBER OF STORIES:
30% SLOPES ON PROPERTY:
MAIN FLOOR SQ FT:
STRUCTURES ON PROPERTY: FINISHED BASEMENT:
NUMBER of BEDROOMS: CRITICAL AREAS: GARAGE: / G x 3 ''
FLANKING SETBACK: CURRENT PROPERTY SIZE: COVERED DECK:
FRONT SETBACK: CURRENT PROPERTY USE: DECK:
REAR SETBACK: CURRENT SEPTIC USE:
LEFT SETBACK: 1 / 6 CURRENT WELL USE:
RIGHT SETBACK: (/11IMPERVIOUS SURFACE AREA:
MANUFACTURED HOME • SIGN
WIDTH: LENGTH:
YEAR: PIT SET:
MANUFACTURER:
SQ FT OF SIGN: HEIGHT OF SIGN:
# OF SIGNS: AREA OF EXIST SIGN:
TYPE OF SIGN:
RELOCATION
FIRE SAFETY
PREVIOUS ADDRESS:
PROPOSED USE:
FIRE SPRINKLER: FIRE ALARM:
PAINT BOOTH: TENT:
FIREWORKS DISPLAY:
BLASTING: DATE/TIME:
WA STATE NON-RESIDENTIAL ENERGY CODE
PLANS EXAMINER:
ADDRESS:.
PHONE: FAX:
CITY, STATE, ZIP
INSPECTOR: PHONE: FAX:
ADDRESS:
CITY, STATE, ZIP
SPECIAL INSPECTIONS
BOLTING
FIRM NAME:
INSPECTOR(S):
®CONCRETE
0 REINFORCEMENT
PHONE:
0 WELDING
FAX:
BUILDING STAFF USE ONLY
1
IS PUBLIC SEWER AVAILABLE: 0 YES 0 NO
IS PUBLIC WATER AVAILABLE: 0 YES 0 NO IF YES, WHICH WATER DIST/IRR:
IS PROPERTY LOCATED WITHIN DESIGNATED STORMWATER CONTROL AREA: 0 YES 0 NO
IS THE PROPERTY LOCATED WITHIN ASA: 0 YES CI NO PSSA: 0 YES 0 NO
1
IF YES: ® COUNTY 0 CITY
DATE:
STAFF:
1
METHOD OF PAYMENT:
0 0
CASH CHECK
BANKCARD #; EXPIRES: VIN #
AUTHOR/ZED SIGNATURE'
*FAXED PERMIT APPLICATIONS WILL ONLY BE ACCEPTED WITH MAJOR BANKCARD
100
J
Prue e -/Y Z, -;h
l
>
APPROVED B
08/06/2063u 12.50 J 56931567
+vCl.J cYJ✓JJ .4€4 24ri:
*Th>16iley
11707 E. Sprague Ave., Suite 106
Spokane Valley, WA 99208
Job Addrss*:
Description:
Subdivision:
Owner.
Applicant:
Address:
Contractor:
Address:
904 N MARGUERITE RD
SPOKANE WA 99212-2724
16 X 34 ATTACHED GARAGE
OWNER IS CONTRACTOR
WALKER, RUSSELL D & ROBIN J
WALKER, RUSSELL 0 & ROBIN J
904 N MARGUERITE RD
SPOKANE, WA 99212-2724
5rrrili tn�
TO 3241567 P.01/02
ACCESSORY BUILDING
THIS IS NOT A PERMIT
Penalties will be assessed for
commencing work without a permit
Application #:
Applied:
Issued:
Expires:
BLD -03-02163
0810612003
02/0212004
Lot: 81k: Parcel No; 46181.1317 Zoning:
Phone: (509) 634-4658
Phone:
Lic No:
General Information:
SERVED BY SEPTIC SYSTEM
WELLS LOCATED ON PROPERTY
no
no
Fees:
Total Calculated:
Deposits/Receipts:
Total Due:
0.00
0.00
0.00
APPROVED BY 1 Om
Somme 51te �. �ra ma & r,
bodro rns, or � t�r ,,
5:u up y' NUT A1.L:7'ilin D lir i sy .tom
Iinatailalion has S9 O approval.
THI8 IS NOT A RlCEIPT
AUG 03 2003 12 50 509324156? PAGE. 01
08/06/2003 12: 5b
PERMIT NO.
APPLICATION DR PRMIT.TO INSTALL OR RECONSTRUCT SEWAGE SPOSAL FACILITIES
5bJ.JL410b i
E. O, PLOEGER, M.'J•. M.P.H., HEA TH_OFFICER
N. 819 Jefferson Street
Spokane, Washington 99201
DA
N9 09508
Name
Address
s
Addresof Proposed _
FIs bassement.for bung
planned?
Type of Use '
r Capacity
Number. of Bedrooms 9 iding.Capaczty
Water Supp k}r--
(City, Well, Spring). AryWell
�Q gals. Style of tan
Septic tank capacity'
sorption its._.. -•-.-_-... ---.- -
Length of disposal ,f iel -- ...- _ _........-I
ton o: Proposed
and others out buildings.
soptic tank.
17.. garage
heavy elope or swampy area or any
pographic details.
(1) Show relative locos
disposal field. we
(2) Make note of any
other important to
Installer
5
;4.
c c‘k 04"
44:47‘4,1,5-
'‘ ;tiiii;0
Final Inspection bate
Remarks:
POON 344 kCV.$t•LTII
AUG 03 2003 12:51
For Spokane County Health District
5093241567 PAGE.03
City of .
SPOKANE VALLEY BUILDING DEPARTMENT •
11707 E. Sprauge Avenue, #106, Spokane Valley, Washington 99206 - Tel 509-921-1000 - Fax 509-921-1008
llowing is a typical cross-section for a residential garage. It may or may not represent the proposed project. If you are using this
tail as a portion ofyourplan submittal, please complete the requested information in the boxes provided on both sides ofthis sheet.
:ompleted sheet,along with any additional information needs to be submitted with your application and be on site at the time of
pection. ,ENGINEERED TRUSS OR,
❑ RAFTER SIZE AND SPACING
X O.C.
ROOFING MATERIAL
iOFING PAPER #15 MINIMUM
DOF SHEATHING TYPE
Cow► p
lS
STUDS
TREATED SILL
• 1/2" X 9" ANCHO
)BOLTS @ 6' 0" O.C.
'3 1/2" CONCRETE SL
(2) #4 REBAR .A
ALTERNATE FOUNDATION FOR
ACCESSORYBUILDINGS FROM
J 1000 SQ. FT. TO 3000 SQ. FT.
►TE:
Diagonal wall bracing required on
each corner and every 25 feet of wall.
Walls within 3 feet of a property line or
within 6 feet of a dwelling must be 1 hour
rated. (5/8" type "X" gypsum sheathing
on both sides of wall). Openings are not
permitted in these walls. Garages over
3,000 sq. ft. require protection when
closer than 20 feet to the property line.
Parapets may be required.
Doors entering a garage from the
house must be 1 3/8" solid core or carry a
120 minute fire rating (self-closing hinges
required). These common walls must also
be protected on the garage side with 5/8"
type 'x' gypsum sheathing.
SIDING
6" min.
SOLID BLOCKI G
BETWEEN TRUSSES
MI =41111
III
FOUNDATI ON DEPTH r 3 1/2"
18" (Detached) l _ I CONCRETE
24" (Attached) 1........:....._ . 1 .AR
6" X 12" FOOTING
SECTION AA
DOUBLE TOP PLATE
WALL HEIGHT
2X 16 I@ D o.c.
PRESSURE
TREATED
PLATE
• ' c
.p^
I'. 1 • ; 6
ANCHOR B OLTS
1/2" X 9"
MINIMUM (7"
CONCRETE) 6'
O.C. OR.
APPROVED
ANCHOR
INSTALLED PER
MANUFACTURER
6" min.
12" min.
12" (2) #4 R
ALTERNATE
FOUNDATION
(DETACHED
UNDER 1000
. FT.)
41.
FOUNDATION PLAN
PLEASE COMPLETE THE FOLLOWING INFORMATION AND ADD ON THE
DRAWING BELOW /
BUILDING DIMENSIONS: 16 X 3
GARAGE DOOR OPENINGANDHEADERSIZE• /L ` c2(g Yio )
INDICATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON
THE PLAN
E
L
Ridge Line
Width
/4o
1
r
L_�
1
J
J
se note that while every effort is made to assure the accuracy of the information contained in this brochure it is not warranted for accuracy.
document is not intended to address all aspects or regulatory requirements for a project and should serve as a starting point for your investiga-
For detailed information on a particular project, permit, or code requirement refer directly to applicable file and/or code/regulatory documents or