2013, 04-30 Energy Compliance CertInspector Copy Property Address: 11819 E Marietta Spokane Valley, WA Conditioned Floor Area 1500 Date 04 /30 / 2013 Builder or registered design professional : SVG Ranch Construction Ftov►te EwerAudit Tech Signature: LH Le growv, 509 220 0321 R -Valves Ceiling: Vaulted R- Floors Over unconditioned space R- 30 Attic R- 38 Slab on grade floor R- Walis: Above grade R- 21 Doors metal R- 5.3 Below, int. R- R - Below, ext. R- R- U -Factors and SHGC NFRC rating (or) Default rating (Chapter 10 WITLC 2009) Windows U- .30 SHGC- .32 Skylights u- SHOC- Clh.apter 9 option(s) HVAC System Heating Cooling DHW Total Clipt 9 Credits 1 .Heating. Cooling t Domestic foot Water Gas forced air electric central -Gas 50 Gal Duct Building Air Leakage All ducts & HVAC in conditioned space (ysz i no) Insulation R- 8 Test Method: x Total leakage Leakage to exterior x Air handler present Efficiency 80% .58 Test Target 90 CFM( 25Pa Test Result 89 CFM(425Pa Building air leakage target: SLA<O.00030 - Tested leakage: SLA= , 0(7Q 3 Onsite Renewable Energy Etc Power System System type: Rated annual generation KIN Is Permit #: House address or lot number: tl 8 1 i Duct Leakage Affidavit ng rcr V\SHINGTON STATI UNIVERSI FY' e ©EXTENSIr�N ENERG} PROGI1 \\t' 1 1 City: Sn JICa'"- t)4//'" Zip: Cond. Floor Area (ft2): i So 0 Source (circle one): Plan Measured ❑ Duct tightness testing is not required for this residence per exceptions listed at the end of this document Air Handler in conditioned space?., 'no Air Handler present during test? g yeses-no— Circle Test Method: Leakage to Outside Maximum duct leakage: Post Construction, total duct leakage: (floor area x .08) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .06) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .06) = 9%0 CFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .04) = CFM@25 Pa Test Result: / CFM@25Pa Ring (circle one if applicable): Open Duct Tester Location: Vas - L}U Jut. 1 3 Pressure Tap Location: C9- tet./) f 4 - kc pi7 y I certify that these duct leakage rates are accurate and determined using standard duct testing -protocol. Company Name: f {(jiw(. emirid ,414itt -reek Technician: Technician Signature: Lyle. 3r -o.• % 9.4.541---• Date: ( /17/)013 Phone Number: S0 9 ZS 0- 0 3 21 Washington State Energy Code reference: 503.10.3 Sealing. All ducts, air handlers, filter boxes, and building cavities used as ducts shall be sealed. Joints and seams shall comply with Section M1601 3 of the International Residential Code or 603.9 of the International Mechanical Code Duct tightness testing shall be conducted to verify that the ducts are sealed. A signed affidavit documenting the test results shall be provided to the jurisdiction having authority by the testing agent. When required by the building official, the test shall be conducted in the presence of department staff. Exceptions: 1. Duct tightness test is not required if the air handler and all ducts are located within conditioned space. 2. Dud testing is not required if the fumace is a nondirect vent type combustion appliance installed in an unconditioned space. A maximum of six feet of connected ductwork in the unconditioned space is allowed. All additional supply and retum ducts shall be within the conditioned space. Ducts outside the conditioned space shall be sealed with a mastic type duct sealant and insulated on the exterior with R-8 insulation for above grade ducts and R-5 water resistant insulation when within a slab or earth. . INTEGRATED WHOLE HOUSE VENTILATION SYSTEM (WSV IAQC SECTION 303.4.2.1) WORKSHEET FOR REQUIRED.FRESH AIR COMBUSTION AIR JOB ADDRESS: // Si q. t- -.ea: FURNACE MODEL NUMBER: N P /V /1,/09.q/7 /�T( ,,_FURNACE BRAND NAME: lat 0%�� WATER HEATER BRAND NAME i/ni. VENTILATION RATE DETERMINATION Floor area (totalsq.ft.) of residence (basement, 1st, 2nd, 3rd floors & bonus room Number of bedrooms in the residence: . 1' Using TABLE 3-2 on the back of this form, determine BTU INPUT: 7t/71 BTU INPUT: 94)/1 Minimum ventilation air = Maximum ventilation air = FORMULA FOR COMBUSTION AIR (1) For Fan Assist Vented.Fumace -i. MBTU input x .4 CFM/BTU •(2) Power Vented Water Heater (Use99OCFM if Rating Unknown) (3) For Draft Hood Applian1 ces % 0 ' MBTU input x .8 CFM/BTU , TOTAL CFM REQUIRED FOR COMBUSTION AIR.... ADD 1 + 2 + 3 //.3 _ /g, -la. v CFM CFM CFM �SD D CFM d. The ventilation/combustion air duct must provide adequiate compustion air or outside combustion air must be provided separately from the ventilation air. (Outside combustion air maybe provided with one (1) duct in the upper 12 inches of the enclosure sized at one (1) square inch per 3,000 BTH/hr input of all the appliances in the enclosure.) Use TABLE 3-5 on the back of this fomi to detemiing ventilation/compustion air duct size. SIZEOFOPENINGS IN WALL OF APPLIANCE ENCLOSURE (IF CONFINED SPACE - LESS THAN 50 CU FT PER 1000 BTU INPUT) PER U.M.C. AND INWHVAC ASSOC. STANDARDS BOOK (1 SQ IN PER 1000 BTU INPUT OF ALL APPLIANCES IN THE ENCLOSURE) = SO IN (NET FREE AREA). (NET FREE AREA = 65% FOR METAL LOUVER; 25% FOR WOOD LOUVERS) VERIFICATION OF PROPER • - • FTING OF APPLIANCES WITH ALL EXHAUST FANS, INCLUDING DRYER IF INSTALLED... J VERIFIED BY;;, r COMPANY NA OPERATING: YES NO AIR DESIGN HEATING & AIR CONDITIONING 13122-/47/ ,LEAVE A•COPY OF THIS FORM ON THE JOAITE AT OR ON THE FURNACE! T Joumeyman:. .4 AP. / Gas;Lc�rise:, Electrical License: TABLE 3-2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES LESS* Minimum Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) Floor Area 2 or Less 75 3 98 80 4 95 143 5 165 125 6 140 210 7 55 83 8 105 (SQ FT) Min. Max Min. 150 Max. Min. 130 Max. Min. 218 Max. Min. 90 Max. Min 90 Max. Min 158 Max. Less than 500 50 75 65 98 80 120 95 143 110 165 125 188 140 210 501-1000 55 83 70 105 85 128 100 150 115 173 130 195 145 218 1001-1500 60 90 75 113 90 135 105 158 120 180 135 203 150 225 1501-2000 65 98 80 120 95 143 110 165 125 188 140 . 210 155 233 2001-2500 70 105 85 128 100 150 115 173' 130 195 145 218 160 240 2501-3000 75 113 90 135 105 158 120 180 135 203 150 225 165 248 3001-3500 80 120 95 143 110 165 125 188 140 210 155 233 170 255 3501-4000 85 128 100 150 115 173 • 130 195 145 218 160 240 175 263 4001-5000 95 143 110 165 125 188 140 210 155 233 170 255 185 278 5001-6000 105 158 120 180 135 203 150 225 165 248 180 270 195 293 6001-7000 115 173 130 195 145 218 160 240 175 263 190 285 205 308 7001-8000 125 188 140 210 155 233 170 255 185 278 200 300 215 323 8001-9000 135 203 150 225 165 248 180 270 195 293 210 315 225 338 Over9000 145 218 160 240 175 263 190 285 205 308 220 330 235 353 For residences that exceed 8 bedrooms, increase the minimum requirement listed for 8 bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 timese the minimum TABLE 3-5 PRESCRIPTIVE INTEGRATED FORCED AIR SUPPLY DUCT SIZING Required Flow (CFM) Per Table 3-2 Minimum Smooth Duct Diameter Minimum Flex Duct Diameter Max. Length * - (Feet)' Max. Elbows" 50 - 80 6" 7" - 20' 3 80 - 125 7" 8" 20' 3 115 - 175 8" - 10" 20'. 3, 170 - 240 9" 11" 20' 3 ' For lengths over 20 feet increase the duct diameter 1 -inch. ** For elbows numbering more than 3, increase the duct diameter 1 -inch. Insulate the ventilation/combustion air duct withing the conditioned space to a minimum of R-4. TABLE 3-3 PRESCRIPTIVE EXHAUST DUCT SIZING Fan Tested CFM at 0.25'W C Min. Flex Diameter Maximum Length Feet Min. Smooth Diameter . Max. Length Feet Maximum I Elbows" 50 . 4 inch 25 4 inch 70 3 50 5 inch 90 5 inch 100 3 50 6 inch NO LMIT 6 inch NO LIMIT 3 • 8D.` . r.. •.- 4 inch" NA 4 inch 20 3 80 .. `.---L T-. `. ' . 5 inch 15 • S inch 100 3 80 6 inch 90 6 inch NO LIMIT 3 100 5 inch"' NA 5 inch 50 3 100 6 inch 45 6 inch , NO LIMIT 3 '"- - 125 6 inch 15 6 inch NO LIMIT .3 125 '_ 7 Inch 70 7 inch NO LIMIT • 3 * For each additional elbow, subtract 10 feet from length. " Flex ducts of this diameter are not permitted with fans of this size. •