HomeMy WebLinkAbout2012, 05-16 Permit App: BLD-2012-0658 ResidenceScm u11LU`le.
•
Community Development Department
Permit Center
11703 East Sprague Avenue, Suite B-3
Spokane Valley, WA 99206
Tel: (509) 688-0036
Fax: (509) 688-0037
permitcenter(alsookanevailev.orq
RESIDENTIAL CONSTRUCTION PERMIT APPLICATION
% NEW CONSTRUCTION ❑ ADDITION/REMODEL
❑ OTHER
0 DECK
SITE ADDRESS: 1 1 620 E Marietta, Avenue
0 ACCESSORY BUILDING
Project # r(z-4Sg
ASSESSORS PARCEL NO.: 45091.3004 LEGAL DESCRIPTION: LREFeiel vee
BUILDING OWNER NAME:
NAME: SVG View Ranch LLC
ADDRESS: 2910 E 13th Avenue
Cm: Spokane
NAT 1 t L.UIE
CSV PERMIT CENTER
STATE: WA
PHONE: 509-951-0239
SUB # I 1ZIP RF \!
FAX; 509-534-1152
951 -0239 --
CONTACT NAME:
PHONE: 509-951-0239
FAX: 509-534-1152
CELL: 509-951-0239
CONTRACTOR NAME: J and E construction
MAILING ADDRESS:
Cmf: Spokane
STATE: WA ZIP:
PHONE: 509-951-0239
FAX: 509-534-1152
CELL: 509-951-0239
CONTRACTOR LICENSE No.:
EXPIRES: CITY BUSINESS LICENSE NO.:
DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE:
Construct 1,125 Sf Ranch Style home on 4,150 sf lot.
Construct 1,125 Sf Ranch Style home on 4,150 sf lot.
****YOU MUST COMPLETE THE FOLLOWING****
Height to Peak: 16
Dimensions: 40 x 40
No. of Stories: 1
Total Habitable 1125
Space:
Main Floor SQ FT
:1125Upper
-:11250
Floor SQ FT:
Unfinished Basement SQ
FT: U
Finished Basement SQ
FT:O
Garage SQ FT: 440
Deck/CoverPatio SQ
FT: 1 0
.w�
Impervious Surface
Area: 1665
30% Slopes on
Property: O
No. of Bedrooms:3
Construction Type:
Heat Source: FAG
Sewer or Septic: sewer
TOTAL COST OF PROJECT: $ 80000
DISCLAIMER
The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling is/will
be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property
owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of
Spokane Valley Development code. Referenced code are a ailable for review at the City of Spokane Valley Permit Center. 5) The City of
Spokane Valley permit is not a permit or approval for . vio t n of federal, state or local laws, codes or ordinances. 6) Plans or additional
information may be required to be submitted and subse. t= tlroved before this application can be processed.
Effective October 28, 2007 Page 1 of 2
P:\Community Development\02 Administration\03 Forms Official Versions\Permit Center\Residential Construction Permit
App 10.28.07.doc
•
LL/ 33
•
TAS Technical Assistance Services
Garden Court Building, 222 W. Mission Avenue. Suite 234, Spokane, WA 99201 (509) 325-4476 FAX (509) 325-4587
11/15/11
City of Spokane Valley Building Department
11707 E. Sprague Ave., #106
Spokane Valley, Wa.
Project Single Family Residence
Total Area: 1130 sq.ft.
rr62.b
Address:4 E. Marietta
Spokane Valley, WA
Contractor/Phone: Carlos Lancia/ 951-0239
Glazing Percentage: 14.6%
'Project #---
RECEIVED
MAY 1 6 2012
CSV PERM; - (-7;; TFEA
Lt.! B # .
PROJECT COMPLIES with TABLE 5-1/ TARGET COMPONENT VALUES FOR GROUP R
OCCUPANCY, 2009 Washington State Energy Code.
ALLOWABLE HEAT LOSS (Btu/h/deg.F)
Glazing: 15% 1130 sq.ft.= 169.5 @ U .30
Doors: 40 sq.ft. @ U .20
Ceiling (Attic): 1143 sq.ft. R38 ADV or R49 STD @ U .027
Walls (1558 gross sq.ft.): 1348 sq.ft. R21 INT @ U .056
Floors: 1130 sq.ft. R30 @ U .029
= 50.9
= 8.0 _.
= 30.9
= 75.5
= 32.8
TOTAL UA ALLOWABLE = 198.1
PROPOSED HEAT LOSS (Btu/h/deg.F)
Glazing (14.6%): 80.5 sq.ft.vinyl operable w/low-E + Argon @ U .30
49.0 sq.ft.vinyl fixed w/low-E + Argon @ U .27
35 sq.ft.vinyl patio w/low-E + Argon @ U .29
Doors: 21 sq.ft. insulated w/ small glass light @ U .20
19 sq.ft. insulated @ U .16
Ceiling: 707 sq.ft. R38 6:12 STD truss @ U .029
436 sq.ft. R38 6:12/3:12 Scissor Truss @ U .031
Walls: 234 sq.ft.R21 INT horiz. Siding @ U .054
1119 sq.ft. R21 INT T1-11 Siding @ U .056
Floor: 1130 sq.ft. R30 @ U .029
TOTAL PROPOSED HEAT LOSS
196.9 Btu/h < 198.1 Btu/h -- Project complies w/ Table 5.1
Edward R. Fields
Technical Assistance Services
11704 E. Marietta
= 24.2
= 13.2
= 10.2
= 4.2
= 3.0
= 20.5
= 13.5
12.6
= 62.7
= 32.8
= 196.9
ESTIMATED HEAT LOSS CALCULATION
For System Sizing
Building Identification: 11704 E. Marietta
Spokane Valley, WA
Interior Temperature: 70 deg.F
Exterior Temperature: 4 deg.F (Spokane)
Temperature differential: 66 deg.F
Component Heat Loss: 196.9 Btu/h per hour x 66 deg. temp. differential
Air Leakage Heat Loss (Volume =10898 cu.ft.): .0168 x 10898 cu.ft. x 66 deg: 12084
12084 x .35 air change per hour
Building Design Heat Load
Duct Heat Load Multiplier (Ducts in unconditioned space): 1.15 x 17,224 Btu/h
= 12,995 Btu/h
= 4.229 Btu/h
17,224 Btti/h
=19,808 Btu/h
ESTIMATED TOTAL HEAT LOSS (Maximum Btu/h) : 19,808 Btu/h x 150% = 29,711 Btu/h
NOTE: This is an estimated heat loss for building permit purposes only. Input Btu/h required depends
on the efficiency of the equipment (fuel fired)— divide the Estimated Total Heat Loss by the % efficiency of
furnace to be used. EXAMPLE: 29,711 Btu/h / 80% efficiency = 37,139 Btu/h input. When sizing the
furnace, pick a unit with a factory input Btu/h that is the closest to the calculated input required but greater
than, not less than, the required input.
It is the mechanical contractor's responsibility to size the system.
2009 Edition
5b
HIGH EFFICIENCY WATER HEATING:1
Water heating system shall include one of the following:
Gas, propane or oil water heater with a minimum EF of 0.82.
or
Solar water heating supplementing a minimum standard water
heater. Solar water heating will provide a rated minimum savings
of 85 therms or 2000 kWh based on the Solar Rating and
Certification Corporation (SRCC) Annual Performance of 0G-300
Certified Solar Water Heating Systems.
or
Electric heat pump water heater with a minimum EF of 2.0.
1.5
6
`'
SMALL DWELLING UNIT 1:'
Dwelling units less than 1500 square feet in floor area with less
than 300 square feet of window -I- door area. Additions to existing
building that are Less than 750 square feet of heated floor area.
1.0
7
LARGE DWELLING UNIT 1:'
Dwelling units exceeding 5000 square feet of floor area shall be
assessed a deduction for purposes of complying with Section 901 of
this Code.
-1.0
8
RENEWABLE ELECTRIC ENERGY:
For each 1200 kWh of electrical generation provided annually by
on-site wind or solar equipment a 0.5 credit shall be allowed, up to
3 credits. Generation shall be calculated as follows:
For solar electric systems, the design shall be demonstrated to meet
this requirement using the National Renewable Energy Laboratory
calculator PVWATTs. Documentation noting solar access shall be
included on the plans.
For wind generation projects designs shall document annual power
generation based on the following factors:
The wind turbine power curve; average annual wind speed at the
site; frequency distribution of the wind speed at the site and height
of the tower.
0.5
•
_
Footnotes:
1. Interior Duct Placement Ducts included as Option 2 of Table 9-1 shall be placed wholly within the heated
envelope of the housing unit. The placement shall be inspected and certified to receive the credits associated with
this option.
EXCEPTION: Ducts complying with this section may have up to 5% of the total Iinear feet of ducts located in the exterior
cavities or buffer spaces of the dwelling. If this exception is used the ducts will be tested to the following standards:
Post -construction test Leakage to outdoors shall be less than or equal to 1 CFM per 100 le of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's
air handler enclosure. All register boots shall be taped or otherwise sealed during the test.
2. Plumbing Fixtures Flow Ratings. Low flow plumbing fixtures (water closets and urinals) and fittings (faucets
and showerheads) shall comply with the following requirements:
(a) Residential bathroom lavatory sink faucets: Maximum flow rate - 3.8 L/min (1.0 gal/min) when tested in
accordance with ASME Al 12.18.1/CSA B125.1.
(b) Residential kitchen faucets: Maximum flow rate - 6.6 L/min (1.75 gal/min) when tested in accordance with
ASME A112.18.1/CSA B 125.1.
(c) Residential showerheads: Maximum flow rate - 6.6 L/min (I.75 gal/min) when tested in accordance with ASME
A112.18.1/CSA B125.1.
Effective July 1, 2010
43
SPoxp COUNTY
Site Information
SPOKANE COUNTY
DEPARTMENT OF BUILDING & PLANNING
1026 WEST BROADWAY AVENUE • SPOKANE, WA 99260-0050
Project Information
Site Address: 11620 E MARIETTA AVE
Parcel Number: 45091.3004
Subdivision: CITY OF SPOKANE VALLEY
Block: 3 Lot: 4
Zoning:
Owner: SVG VIEW RANCH, LLC
Address: 2910 E 13TH AVE
SPOKANE, WA 99202 -
Building Inspector:
Water Dist:
Project Number: 11006521 Inv:
Permit Use: SEWER CONNECTION
Applicant: C & L EXCAVATION
26826 N SPOTTED RD
DEER PARK, WA 99006
Contact: C & L EXCAVATION
26826 N SPOTTED RD
DEER PARK, WA 99006
Setbacks - Front:
Group Name:
Project Name:
1 Issue Date: 12/28/2011
Phone: (509) 993-0040
Phone: (509) 993-0040
Left: Right: Rear:
Permits
Sewer Connection Permit
Contractor: C & L EXCAVATION License #: CLEXCLE962RP
SEWER CONNECTION 1 $125.00 PROCESSING FEE 1 $25.00
Total Permit Fee: $150.00
**FOR SEWER INSPECTIONS CALL THE UTILITIES DEPT AT (509) 477-3604 FROM 8:30-5:00 MONDAY -FRIDAY PRIOR TO
COVER. ONE WORKING DAY NOTICE REQUIRED. PERMIT ALLOWS FOR A 30 -MINUTE INSPECTION. ADDITIONAL
INSPECTION FEES APPLY AFTER 30 MINUTES.
**INSTALLER IS RESPONSIBLE TO INSURE ALL WASTEWATER DRAINS ARE CONNECTED TO THE SEWER AND MAY
BE REQUIRED TO PERFORM TESTS FOR VERIFICATION. INSTALLER IS TO FIELD LOCATE AND CONFIRM THE
ELEVATION AND POSITION OF SEWER STUB PRIOR TO ANY OTHER EXCAVATION.
**SEWER STUBS AND DRY SIDE SEWERS ARE TO BE CHECKED PRIOR TO CONNECTION TO ENSURE THAT THEY
HAVE ACCEPTABLE GRADE AND ARE CLEAR AND UNOBSTRUCTED. SEWER LINES SHOULD BE CONSTRUCTED TO
ALLOW FOR GRAVITY FLOW FROM THE LOWEST LEVEL OF THE STRUCTURE.
**THE INSTALLER AND THIS PERMIT MUST BE PRESENT AT THE J013 SITE AT THE SCHEDULED INSPECTION TIME.
BOTH STATE LAW RCW 19.122 AND COUNTY CODE REQUIRES THE INSTALLER TO GIVE NOTICE OF EXCAVATION TO
OWNERS OF UNDERGROUND FACILITIES.
**CALL 1-800-424-5555 BEFORE YOU DIG --AT LEAST 2 WORKING DAYS IN ADVANCE. SPOKANE COUNTY CODE
REQUIRES THE INSTALLER COMPLY WITH ALL REQUIREMENTS OF THE WA STATE DEPT OF LABOR & INDUSTRIES,
INCLUDING THOSE RELATED TO TRENCH SAFETY.
Payment Summary
Total Fees AmountPaid AmountOwing
$150.00 $150.00 $0.00
Tran Date
12/28/2011
Processed By: SHATTO, JULIE
Printed By: Force, Faith Page 1 of 1
Receipt # Payment Amt
5758 $150.00
PERMIT
• NOTICE
It is the responsibility of the applicant/permittee to see to it that the use described on the front of this permit complies with applicable codes and
requirements and that required inspections are requested. Failure to request inspections as listed below and obtain the necessary approvals before
progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the applicant's/permittee's
or property owner's expense. At a minimum, the following inspections ARE REQUIRED by County Code:
1. FOOTING - all structures, including manufactured homes when forms and reinforcement are in place and prior to placement of concrete.
NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zon-
ing regulations. Front, flanking, side and rear yard setbacks are measured from property lines. Curb lines and fence lines are not necessarily
indicative of property lines. In some residential areas, the County can own as much as 20 feet of right-of-way between your property and the
actual improved street/curb. The responsibility to comply with applicable setback provisions lies solely with the permittee—neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your property lines. Please verify their
location prior to locating your structure. Failure to properly locate the structure may require its relocation at the owner's/permittee's expense.
2. FOUNDATION - when forms and reinforcement are in place and prior to placement of concrete.
3. FRAMING - after all framing, bracing and blocking is in place, plumbing, mechanical rough -in inspections have been approved, and prior to
concealing.
4. INSULATION - prior to the installation of drywall.
5. PLUMBING - after rough -in, before covering, and final.
6. MECHANICAL - rough -in of piping, before covering, metal chimneys before concealment, and final.
7. FINAL - all permits - when complete and prior to occupancy and/or use. Please provide 24 hours notice. NOTE: In addition to inspection of
the structure, this inspection includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a
condition of approval of this permit. Items such as the installation of fire hydrants, fire department access, on-site drainage ("208 swales"),
road improvements, parking, and landscaping are common requirements of a permit/site plan which must be completed prior to final ap-
proval of a building or issuance of a Certificate of Occupancy.
8. MANUFACTURED HOMES - foundation inspections prior to pouring pads, inspection of blocking/tie-downs, when completed per
manufacturers installation instructions. Final Inspection approval prior to occupancy: stairs, handrails, skirting, etc., installations completed
WAINS Tag(s) must be affixed to the home, completed inspection record card and manufacturer's installation instructions must be available on
site.
9. SEWERS - prior to cover
10. RIGHT-OF-WAY/APPROACH - prior to placement of concrete, or, if gravel approach, after completion.
In addition to the above, any plumbing or mechanical systems or material which would be concealed by framing, drywall, concrete, etc., must be
inspected prior to cover. Check with the department for "special inspections" in conjunction with commercial projects.
FOR INSPECTIONS:
TO INSURE PROMPT SERVICE, PLEASE GIVE ONE WORKING DAY/24 HOUR NOTICE .
PARTS OF YOUR PROJECT MAY REQUIRE PERMITS AND INSPECTIONS
FROM MORE THAN ONE AGENCY.
• Building, plumbing, mechanical and fire inspections -Department
of Building & Planning 477-3675
• Construction in a flood plain - Division of Engineering & Roads 477-
3600
• Electrical wiring - State Department of Labor and Industries 324-2640
• On-site waste disposal system, Spokane Regional Health District
324-1560
• Road cuts for utilities or driveways - Division of Engineering &
Roads - 48-HOUR NOTICE REQUIRED 477-3600 or State
Department of Transportation 456-3000
• Sewer connection, Division of Utilities- 477-3604 or City Pub-
lic Works Department 625-6300
• Asbestos, Renovations, and Demolitions - Spokane Regional
Clean Air Agency 477-4727
PERMIT EXPIRATION & EXTENSION
Building permits shall automatically expire and become invalid by limitation of time three (3) years from the date of permit issuance. Other permits not
issued in conjunction with the construction or completion of a building or structure shall automatically expire and become invalid by limitation of time
18 months from the date of permit issuance. The Director is authorized within his/her discretion to grant one (1) extension of time, for a period not to
exceed 180 days. A request for an extension shall be made by the permit holder in writing and shall be submitted to and received by the Spokane County
Building and Planning Department prior to the expiration date of the permit and shall demonstrate just cause for the requested extension.
REFUNDS
The building official may authorize refunding: (1) Any fee paid which was erroneously paid or collected; or, (2) Not more than 80°/ of a permit fee
paid when no work has been done under the permit; or, (3) Not more than 80% of the plan review fee paid when an application for a permit for which
a plan review fee has been paid is withdrawn or canceled before any plan reviewing is done; or, (4) Any fee paid except on written application filed
by the original permittee not later than 180 days after the date of fee payment. Please note that application processing fees are nonrefundable unless
the application was erroneously processed.
MISTAKE?
If you think we've made an error in processing this permit or find erroneous information on the permit, please bring it to our attention immediately
by filing a written request for correction within 10 working days of discovery. All such requests should be directed to the Department of Building
and Planning at:
Spokane County Department of Building & Planning
1026 West Broadway Avenue Spokane, WA 99260
Phone: (509) 477-3675 Fax: (509) 477-4703 TDD: (509) 477-7133
REVISED 121111 BLDG PERMIT