Loading...
2005, 10-14 Permit App: 05003842 GradingProject Number: 05003842 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 10/14/2005 Page 1 of 2 Project Information: Permit Use: MORNING CREST - GRADING FOR WATER AND Contact: BLEWS CUSTOM HOMES, INC Address: 4810 S MORROW DARK RD C - S - Z: SPOKANE, WA 99206 Setbacks: Front Lefl: Right: Rear: Phone: (509) 928-6227 Group Name: Site Information: Project Name: GRADING - MORNING CREST UTILITIES Plat Key: 999999 Name: RANGE District: Sout Parcel Number: 45221.9030 Block: SiteAddress: 209 S MCDONALD RD Location:: CSV Zoning: UR -12 Water District - Urban Residential -12 Lot: Owner: Name: BLEWS CUSTOM HOMES, INC Address: 4810 S MORROW OARK RD SPOKANE, WA 99206 Hold: ❑ Area: 2.38 Acres Width: 0 Depth: 0 Right Of Way (ft): 50 Nbr of Bldgs: 2 Nbr of Dwellings: 18 Review Information: Review Site Plan Review - Released 13 Approach / Drainage • hb S�C11k��G� 8rc tn� CLQ OL -p p rcSJ cJ- Stormwater Control Released By Permits: Operator: MT Printed By: MT Print Date: 10/14/2005 Project Number: 05003842 Inv: 1 Application Date: 10/14/2005 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Grading Permit Contractor: SALCO INDUSTRIES Firm: SALCO INDUSTRIES Address: 0 N UNICNOWN ST Phone: (000) 000-0000 NINE MILE FALLS, WA 99026 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation GRADING NONE NONE WATER / 60 $60.00 60 $60.00 UTILITIES Item Description PERMIT FEE - RESIDENTIAL REVIEW FEE - RESIDENTIAL Totals: 60 $60.00 60 $60.00 Units Unit Desc 1 SELECT I SELECT Fee Amount $20.00 $12.00 Permit Total Fees: $32.00 Notes: , Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Grading Permit $32.00 $32.00 $0.00 $32.00 $32.00 $32.00 $0.00 $32.00 Disclaimer: Submittal of this application certifles the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: MT Printed By: MT Print Date: 10/14/2005 Spokane .0,00Ualley Community Development Grading Permit Application Permit Center 11707 E Sprague Ave, Suite 106 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)6 www.suokanevalley.ore.co 2rUn SITE ADDRESS 9.0`i S. it -bonctU /Clearing ��jjIktkGrading roi{ltt& fSite Improvements/Landscaping (� Jd SQa-ane. Jatt€ ,WA ASSESSORS PARCEL NO: 4Sd-a l.9030 LEGAL DESCRIPTION: 52.2 61-44(4- 0j.0-ct Property Owner' "� Name: Ele,,,'s C._s��. t4) n,25 rwc • Manager/Contact Person: Seri-$- (318,..) Address:4810 S. &orrow Po -€k City: Sovkc.etc State: (,Wfk- Zip: G9a.o(0 Phone: 4 Z£r-0).-zfl Fax: q Z$- S -I 2-3 Contact Person Name: SCo,H- (31 Q W Phone: q9LI- ens -0 Identify and describe the work and indicate the use: 4ee a1/41-4-&ckt4. Excavation Contractor - Name: CA leo .i4.44u5`61,93 J-v..c. Address: (ill to /.(-,,,,r a4 CAT i,ne Aide calls State: imA Zip:79o2(o Phone: a-lle-(.c(;aO Fax: Lic No: 5a l eo V , 991 k L Exp. Date: 3 /13 Pio City Business Lic No: y.- u sU5 s'`fS Engineer - Company Name: 5,,., pS o n E, -,,,t nee v s Tr-- Address: fel 909 Arta nnt_ ;20e11 Cityspok-“nt tj Rc-( State: 6011 Zip:99212- Phone: 126,-i 3 a a Fax gal- 13 23 Lic No: ,231 CCI,,,,e-k S �ps.”„ t 99b-73 Soil Testing Firm - T Company Name: Sfyet-1-a, ,the. Address: ) (oao Al Ma -me -r %Zoc..d City: seol.v.n, Val(e.i State: (,JYl Zip: nal(0 Phone: Q9l - 19o4 Fax: &9(-a0 l a Estimated Excavation/Cut (Cu Yd): 601,44 Estimated Embankment/Fill (Cu Yd): (o 0 05 Destination of Excavated Materials: {Hwy a1 I 51-(9 ' fie. Start Date: to/17% S Estimated Completion Date: 3/3t)2330(0 DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and'subsequently approved before this application can beprocessed. Signature Date /07/c.45 - Method of Payment: (Faxed permit applications will only be accepted with major bankcard) ❑ Cash ❑ Check ❑ Mastercard ❑ VISA Bankcard #: Expires: VIN#: ❑ Other Authorized Signature: REVISED 8/25/2005 BLEW'S CUSTOM HOMES, INC. 4810 S. Morrow Park Rd. Spokane, WA 99206 (509)928-6227 (Office) (509)928-5723 (Fax) City of Spokane Valley RE: Morning Crest Eighteen (18) Zero Lot Line Single Family Homes 3rd Avenue Extension and Utilities for Morning Crest We are requesting early review and approval of the Grading Permit Application in order to complete work before winter weather prohibits further construction. We want to proceed with the 3"' Avenue extension, our excavator should complete the McDonald road work on Friday, October 14th, and would like to stay on-site and complete the remaining underground utility work, sewer, water, utilities, 208 swale and road sub - grade. Asphalt can not be accomplished this year due to weather. We will complete the asphalt, sidewalk and curb in the spring of 2006 as soon as weather permits (estimated March 31, 2006). In any event, we will complete the work prior to receiving Certificates of Occupancy. We will complete the required Type III landscaping along McDonald road upon completion of the building structure on the corresponding lot. Spokane Valley Fire District No. 1, Bill Clifford, Modern Electric, Dave Johnson and John McFeely, Spokane County Division of Utilities, Billy Housen, Spokane County Regional Health District, Don Copley, Avista, Qwest, Comcast have all seen the submitted plans and have not had any objections to our moving forward with the work described above. Excavator: Salco Industries, Inc. Engineer: Simpson Engineering, Inc State of WA #231, Chuck Simpson, PE #9967 Engineer/Soils: Strata, Inc, They will perforin sewer inspection and soil compaction test and report for Simpson Engineers. All final plat documents have been re -submitted to Karen Kendall, Assistant Planner and all road, water and sewer plans have been re -submitted to Sandra Raskell, P.E., Development Engineer with the City of Spokane Valley. Prior to building permit issuance we will have the 3`d Avenue extension prepared to sub - grade with 4 inches of gravel pack and obtain a letter approval from Spokane Valley Fire District No. 1. Prior to Certificate of Occupancy being issued road, sidewalk and curb will be completed. Blew's Custom Home's Inc. assumes all risk and responsibility to continue the project. Blew's Custom Homes, Inc. releases the City of Spokane Valley from any liability resulting from granting this request. Sincerely, Scott Blew President Form No. 14 Subdivns;on Guarantee (4-10-75) Exhibit "A" Guarantee Nz 1259-660672 Page No. 6 Real property in the County of Spokane, State of Washington, described as follows. That part of the Northwest quarter (NW'/a) of the Northeast quarter (NEV.) of Section twenty-two (22), Township twenty-five (25) North, Range forty-four (44) East of the Willamette Meridian, in the City of Spokane Valley, Spokane County, Washington, described as follows: BEGINNING at a point four hundred thirty-four and 3/10 (434.3) feet North of the Sou:hwe st corner of the Northwest quarter (NW1/4) of the Northeast quarter (NE1/4) of said Section twenty-two (22), thence East two hundred forty-seven and 5/10 (247.5) feet; thence South eight -six and 85/100 (86.85) feet; thence East two hundred forty-seven and 5/10 (241.5) feet; thence North two hundred sixty and 55/100 (260.55) feet; thence West four hundred ninety-five (495) feet; thence Scuth one hundred seventy-three and 7/10 (173.7) feet to the POINT OF BEGINNING; • EXCEPT any portion thereof included in the right of way conveyed to the Idaho and Western Railway (Now Chicago, Milwaukee, and Puget Sound Railway Company). ALSO EXCEPT that portion deeded to Spokane County for McDonald Road under Auditor's File No. 466129C. Tax Parcel Number: 45221.9030 FirstAmeicar Ttle C M SP f P RR R/W (neaaN) 44 wnT P4-tgr i i 95 i Ijzl3 CY F g6= 6, ALM 0_ sow 6 4,4 RR .J.,, 21/Y1 anre 5 r 1 r NORTH NOTE k 2247 I 3 SP -(306-02 LEGEND ♦at r.= 2 AUDITOR'S CERTIFICATE ths—wv —of a_ awwa Oa avast Sahara Raab EQUIPMENT ! PROCEDURE MIR away tas war,. w on 111 S20 :JUROR,' es BASIS 0) BEARING ma Ley w wm22. ZS if s.as 0a., e. LOY. ay sY... NC /bb ika RR v4 smewr awae9a..rvwfa. vNe.e- SURVEYOR'S CERTIFICATE ey apaw; Cana9.0..,.1L e.L„f, MORNING CREST REZ-20-04/SUB-14-04 A PGT IN A PORT/ON 0P THE NE I/4 SECTION 42, T25 N. R44 EMM SPOKANE VALLEY WASHINGTON _Y,Y"o" Engineers, Int COAL 4 NS ROAD, N 909 60 2, SPD(NIE Y 99212-2709 e w ulumen SE SW —a w aw— w -ter" sem Tata . us 114 al So la Sas— a Pae r? a-� wa.—Oro 'uµ. Wu a Sr lwtw«w OATS -4 4—, 424 44.41 zia rat Fpe wa -. 4casrs ra 247.5 lo AsMA Path US foot ri — w n APas ow awl InM 11 of • ory ".r wthw F as MA 4 s « Sr se 2..-.. MS - a+w+ — m n.. — Par — wWlW °L palm w 44lar. oub ry wear Par • w « My of yam Wok lane of ynw M. a Sark. MrY- mar S Vs SIM SS ISIS Ss I• SeaF man® mna oopSow at Fw0 woo mows awv r4W m l....li M 1w lw lnv1I«s r- 2a - sow set ..lprs ore 4,421 a raw 970 4444-4wi strata as - i.. a.. .. tin• /-.°aw-rare«r+I.+nk+.arwa— O� Sans p.a«wrAA r7yr. bo awes -..-.w m. sora lams, by a7..-...1. ..4+1 .m. Pa a AS — sae -.a.. as .4,-1 « m- mr mama a w a, PST m —Is Woad 1 SI a4 to Ther Fain ooriS7 • asIla kW as 4144 Mb to Wawa SI SY v aw a .......r a same. wen.aPar.raSa- ▪ .l .a.. 2,444 444 «.7 a.Paan as «Ywa pa SW m.w7..7f «alwaw.a Paa«w nye. Soy sof as to Om sand Saw aw S W la 01 WS ko walra of WI ols « ..M.) - -mm,4 m- to pi F -r ale Sawn. km sr a.Yµ-wax 7.22.Sana wa — SFS ." SOS - SA d000roloslao slaty as Asa ra dam W CAWS Van so T'T ST AT yal a` th. 0.w-•.,«.-wa-s «...I« mrra«w-.a DEDICATION Y VYaw aewYar y4 " Soo a. thane-,*-- thane--s2.-a «a.airmYr rkam --4-. Mm -ni. 1 4 -Y w W. wk4 Pa.Yss..ww wv2 Sys~ i/"`Sawa 0 rm. .10 e aea OM firlo At4 ""wi�wa4 4--. MFr.F aF Taw w •a "-vbr.aratS ST St Has ASS RW tits' Troa A sal ad or WS al WI Sara San *Ran «.aa.waaa.w1FY Fw Sa F «a. D.S. 0-4 :. oae.(«rra�".�r rte.. w 52044 OwPa 4.4-1.0' 0..ar a .... « ,.aa Sm w aa.m.ar.. a 7a as to to slat Par COS of SSW, TW Tata wly As sang ST ea._2_`.07`m F - m �. S • W FAA Son or SSA urn AA. 1.6 roW1 44SSa..a. Rap .-.r.....-7451.212". 0F. 715.141411112 ice+. IS WS) .ra sW 14. m.wr « MS OS Y w a- a Penn a ' SamSod .r-w—d., ACENOILIDCARNT STATE Cr us -Ten v Oyer or wow) ... " ` W. spa we. b a7.-1 .4 warm kw saw l.a air r.. 02722 rr.sa.arw--I S.0 Frs..lw«k l.. ar «r.Mam-"M at we IS ad 22.0 .a Mka"«b Mr: eY« ▪ atm ronr. 1 is SW r akart .a EMS day -. w—.7 ratika AC.NOILEDCYENf WRAY OF `4442 OPS a.a.. b&"..'- 2- .'`"''""' bast rr'°". ao as 2`«`-•.:. mans. ="a waat e ▪ -.••r was =."? eY««44 .ansa MORNING CREST REZ-20-04/SUB-14-04 A PLAT IN A PORTION OF TNT NE I/4 SEC17011 PE T26 N, 1[44 TEN SPOKANE PALLET. WASNINCTON AUDITOR'S CERTIFICATE FAS for sod—RR FS Pogo Ines Cos taw SORRRIS CQIRNIR Ss Amaraat lei r' na CITY f COUNTY OFFICLILS I PM) MILLET lellt/0/7 It Mir Sir E sb. w.. -a Va_ air® 04 .0 sax. wa MM. Inn s w. - o no, mom Wan ISISIM CONSIMPT r-.w..w.e...Ink _ray a 0024 Me= ICI> ins =Tuns • m ore. ..—Oa a Sr may y....1 of raw ad Vaasa r ..-a thw_a a. Matt MOS/ KW= ra.wa.a sea na_a a. eaw cOrmans IF.. aie rL tor .rte. aak......Y. ..w. a - jraorf Vv inguten int COAL [NSW . INC#2 SURVEYORS vva a Sas "am.c mu, a VA. 9921E -E019 ru a1.4310 4 wg 08/22/2005 09:33:18 AM PDT PAProjects\14501-15000\14811\dwg\14 Ex Fire Hydrant x Ex Fire Hydrant C M SP & P RR R/W (vacated) u 1 2 3 4 5 3 = e -0 — fn 3!^ y -0- — struct 8" PVC 8 ;s 150 C900 Watermain to (n 3 !m rn 3 3 to a a _ a 9 10 11 12 to In 3 a 0- r C/1 3!� = a AYE --c Install 10"x8" FL SS Tapping Tee -TR. 4-- — — with Concrete Thrust Blocking to West with 8" R.S. Gate Valve, FLxMJ to East cn E 3 � 3 3 to t to v tn M 0 0 z 25' 1 P 2 1 2 3 O 4 5 6 20'. 3 4 Install Fire Hydrant per MEW Co. Standard Construct 6" PVC Class 150 C900 Watermain Install 8"x8"x6" Flanged Tee with 8" Gate Valve, FLxFL and Blind Flange to East 6" Gate Valve, FLxMJ to North Concrete Blocking to South & Easy I UNPLATTED 0 25 50 100 !!!!!!!1 EXPIRES 07/17/07 VERTICAL THRUST BLOCKING PIPE DIAMETER VOLUME OF THRUST 'LOCKING (CU. FT.) 90DB45D BENDBEND (, 22 BEND 1/20 11 1/4D 6" 1.8 0.9 ( 0.4 8" 3.2 1.7 f 0.8 0.3 10" 4.9 2.6 1.3 0.5 12" 7.0 3.7 _ 1.8 nR NOTE: THRUST BLOCK VOLUME BASED ON 4000 lbs/cu. yd. FOR CONCRETE AND A HYDRAULIC TEST PRESSURE OF 150 psi. THRUST BLOCK VOLUMES SHALL BE PROPORTIONALLY ADJUSTED FOR DIFFERENT HYDRAULIC TEST PRESSURES. CONCRETE THRUST 3LOCKING FOR FITTINGS AND 1 VALVES NOTE: BEARING AREA BASED ON 2000 lbs/sq. ft. ALLOWABLE SOIL PRESSURE AND 150 psi HYDRAULIC TEST PRESSURE BEARING AREA SHALL BE PROPORTIONALLY ADJUSTED FOR DIFFERENT ALLOWABLE SOIL PRESSURES OR HYDRAULIC TEST PRESSURES. GENERAL WATER NOTES 1) Simpson Engineers, Inc., at 926-1322, must be called for inspection of any closures. 2) Modern Electric Water Co., at 928-4540, must be called for inspection of any closures. 3) Watermain location must be determined by Simpson Engineers. 4) All materials must be inspected and approved by M.E.W. Co. prior to installation. 5) Watermains must be disinfected to the satisfaction of the Department of Health for the State of Washington. 6) Watermains to be pressured tested at 150 p.s.i. for at least 30 minutes to the satisfaction of Simpson Engineers. 7) Watermains to have 4'-6" minimum cover. 8) Contractor shall obtain street opening permit from Spokane Volley prior to construction. 9) Fire hydrants and their installation shall be according to M.E.W. Co. standard. 10) All materials must be new. 11) Thrust blocks shall be precast, reinforced concrete, 6"x24"x36" M.E.W. standard. 12) Watermain shall be a minimum of ten feet from sanitary sewer lines. 13) Watermain and water services crossing sanitary sewers and less than 18" below sanitary sewers must be sleeved 20 feet (no joints) with 10 feet each side of sewer. 14) Water services must have ball valves on service connections with traffic model valve boxes. 15) Thrust blocks shall be installed at all horizontal or vertical bends of 22-i degrees or greater and at all tees. 16) Watermains to be Class 150 AWWA C 900 PVC, or Class 50 Ductile Iron water pipe. 17) Wotermeters and vaults to be provided and installed by M.E.W. Co. 18) M.E.W. Co. requires prepayment for all work to be performed by the company. 19) if watermain is constructed through a "208" drainage swale or pond, then a 4'-6" cover must be maintained from top of watermain to finished grade. 20) All plastic waterlines are to have a "Tracer Wire" installed parallel to them and grounded to M.E.W. Co. lines. 21) All work to be performed in accordance with; policies of the Modern Electric Water Company. 22) Deviations from the approved materials shown on this pian must be requested from M.E.W. Co. in writing, and will be responded to in writing'. TYPICAL STEEL STRAP INSTALLATION (FOR VALVES, TEES, ELBOWS, OR CROSSES ANCHORED TO CONCRETE BLOCKING) /5 REBAR FOR 6" AND 8" PIPE r i 16 FOR 10" AND 12" PIPE LOCATION OF THRUST BLOCKS UNDISTURBED EARTH (TYP) ar• 1$ BEARING AREA PER TABLE (TYP) Examined and approved this 27' day of AuQasr ,2005 Spokane Examined and approved thiSZ5 day of Co y Fire ern Elec'"7N c Water Company Examined and approved this Z,1r» day of t l' r7I'G 'strict No.1 ,2005 Fos - 'S x542005 Spokane Regional Healt stri t Examined and approved this Z'V day of A q J 2005 DeveloperJ WATER MAP FOR MORNING CREST A PLAT IN A PORTION OF THE NE 1/4 OF SEC.22, T25N, ' R44 EWM SPOKANE VALLEY, WASHINGTON Founded 1946 Vimpson Engineers, Inc. CIVIL ENGINEERS & LAND SURVEYORS N. 909 ARGONNE ROAD, SPOKANE WA., 99212-2789 PHONE (509) 926-1322 FAX (509) 926-1323 1 /1 CALL BEFORE YOU DIG 456-8000 PIPE DIAMETER BEARING AREA (SQ. FT.) TEE, CAP, LINE VALVE 900 BEND 45D BEND 22 1/2D BEND 11 1/4D BEND 6"4 7 4 2 1 8" 8 11 6 3 2 10" 131810 5 3 12" 18 25� 14 7 4 NOTE: BEARING AREA BASED ON 2000 lbs/sq. ft. ALLOWABLE SOIL PRESSURE AND 150 psi HYDRAULIC TEST PRESSURE BEARING AREA SHALL BE PROPORTIONALLY ADJUSTED FOR DIFFERENT ALLOWABLE SOIL PRESSURES OR HYDRAULIC TEST PRESSURES. GENERAL WATER NOTES 1) Simpson Engineers, Inc., at 926-1322, must be called for inspection of any closures. 2) Modern Electric Water Co., at 928-4540, must be called for inspection of any closures. 3) Watermain location must be determined by Simpson Engineers. 4) All materials must be inspected and approved by M.E.W. Co. prior to installation. 5) Watermains must be disinfected to the satisfaction of the Department of Health for the State of Washington. 6) Watermains to be pressured tested at 150 p.s.i. for at least 30 minutes to the satisfaction of Simpson Engineers. 7) Watermains to have 4'-6" minimum cover. 8) Contractor shall obtain street opening permit from Spokane Volley prior to construction. 9) Fire hydrants and their installation shall be according to M.E.W. Co. standard. 10) All materials must be new. 11) Thrust blocks shall be precast, reinforced concrete, 6"x24"x36" M.E.W. standard. 12) Watermain shall be a minimum of ten feet from sanitary sewer lines. 13) Watermain and water services crossing sanitary sewers and less than 18" below sanitary sewers must be sleeved 20 feet (no joints) with 10 feet each side of sewer. 14) Water services must have ball valves on service connections with traffic model valve boxes. 15) Thrust blocks shall be installed at all horizontal or vertical bends of 22-i degrees or greater and at all tees. 16) Watermains to be Class 150 AWWA C 900 PVC, or Class 50 Ductile Iron water pipe. 17) Wotermeters and vaults to be provided and installed by M.E.W. Co. 18) M.E.W. Co. requires prepayment for all work to be performed by the company. 19) if watermain is constructed through a "208" drainage swale or pond, then a 4'-6" cover must be maintained from top of watermain to finished grade. 20) All plastic waterlines are to have a "Tracer Wire" installed parallel to them and grounded to M.E.W. Co. lines. 21) All work to be performed in accordance with; policies of the Modern Electric Water Company. 22) Deviations from the approved materials shown on this pian must be requested from M.E.W. Co. in writing, and will be responded to in writing'. TYPICAL STEEL STRAP INSTALLATION (FOR VALVES, TEES, ELBOWS, OR CROSSES ANCHORED TO CONCRETE BLOCKING) /5 REBAR FOR 6" AND 8" PIPE r i 16 FOR 10" AND 12" PIPE LOCATION OF THRUST BLOCKS UNDISTURBED EARTH (TYP) ar• 1$ BEARING AREA PER TABLE (TYP) Examined and approved this 27' day of AuQasr ,2005 Spokane Examined and approved thiSZ5 day of Co y Fire ern Elec'"7N c Water Company Examined and approved this Z,1r» day of t l' r7I'G 'strict No.1 ,2005 Fos - 'S x542005 Spokane Regional Healt stri t Examined and approved this Z'V day of A q J 2005 DeveloperJ WATER MAP FOR MORNING CREST A PLAT IN A PORTION OF THE NE 1/4 OF SEC.22, T25N, ' R44 EWM SPOKANE VALLEY, WASHINGTON Founded 1946 Vimpson Engineers, Inc. CIVIL ENGINEERS & LAND SURVEYORS N. 909 ARGONNE ROAD, SPOKANE WA., 99212-2789 PHONE (509) 926-1322 FAX (509) 926-1323 1 /1 CALL BEFORE YOU DIG 456-8000