2007, 04-03 Permit: 07001753 SewerSPOKANE COUNTY
y�p�y DEPARTMENT OF BUILDING & PLANNING
S '•'n 1026 WEST BROADWAY AVENUE • SPOKANE, WA 99260-0050
1 Site Information Project Information I
Site Address: 3810 S MCDONALD LN
Parcel Number: 45345.9149
Subdivision: RANGE
Block: 2
Lot: 9
Zoning: UNK Unknown
Owner: LEXINGTON HOMES INC
Address: P0 130X 141749
SPOKANE, WA 99214
Building Inspector: Dan Howard
Water Dist:
Project Number: 07001753 Inv: 1 Issue Date: 4/3/2007
Permit Use: SEWER CONNECTION - PINE ROCK RIDGE III
Applicant: LEXINGTON HOMES INC
PO 130X 141749
SPOKANE, WA 99214
Contact: LEXINGTON HOMES INC
PO 130X 141749
SI'OKANE, WA 99214
Setbacks - Front: Left:
Group Name:
Project Name:
Phone: (509) 924-1519
Phone: (509)924-1519
Right: Rear:
1 Permits I
Sewer Connection Permit Contractor: C & L EXCAVATION I 1 License #: CLEXCLE962RP
SEWER CONNECTION
1 $85.00 PROCESSING FEE
1 $1500
Total Permit Fee: $100.00
FOR SEWER INSPECTIONS CALL THE UTILITIES DEPT�A1»09) 477-3604 FROM 8:30-5:00 MONDAY -FRIDAY PRIOR TO
COVER. ONE WORKING DAY NOTICE REQUIRED. PERMIT ALLOWS FOR A 30 -MINUTE INSPECTION ADDITIONAL
INSPECTION FEES APPLY AFTER 30 MINUTES P:1 \iv
\;
'1'1113 INSTALLER IS RESPONSIBLE TO INSURE ALL WASTEWATER DRAINS ARE CONNECTED TO TIIE SEWER AND
MAY 13E REQUIRED TO PERFORM TESTS FOR VERIFICATION.:INS'TALLER IS TO FIELD LOCATE AND CONFIRM THE
ELEVATION AND POSITION OF SEWER STUB PRIOR mANY, 0 FHER EXCAVATION.
SEWER STUBS ARE To BE CHECKED PRIOR TO CONNECION=133ENSURE THAT THEY HAVE ACCEPTABLE GRADE
ANI) ARE CLEAR AND UNOBSTRUCTED TO THE MAIN SE' WER LINES SHOULD I3E CONSTRUCTED TO ALLOW FOR
GRAVITY FLOW FROM THE LOWEST LEVEL OF TILE STRUGfURE. \
E
THE INSTALLER AND THIS PERMIT MUST BE'PRESENTIAI; THEH013 sit Ar TIIE SCHEDULED INSPECTION TIME
13OT11 STATE LAW RCW 19.122 AND COUNTY CODE REQUIRESrTIE INS'T'ALLER TO GIVE NOTICE OF EXCAVATION TO
OWNERS OF UNDERGROUND FACILITIES! 1 111 110 !Id 011
CALL 1-800-424-5555 BEFORE YOU DIG --AT LEAST 2 WORKING'DAYS IN ADVANCE. SPOKANE COUNTY CODE
REQUIRES THE INSTALLER COMPLY1WITF ALEREQUIREMENTS'OE,,TuE WATSTATE DEPT OF LABOR & INDUSTRIES.
INCLUDING TIIOSE RELATED TO TRENCH SAFETYt1\ t \�J�l ilU�.ei 1 I
Payment Summary
Total Fees AmountPaid AmountOwing
5100.00 5100 00
50.00
Tran Date
4/3/2007
Receipt H
1527
Payment Amt
5100.00
1
Notes / Conditions of Approval
1
POSSIBLE DNR STREAM ON SITE
Processed By: CUMMINGS. KATHY
Printed By: I IINTZ. FAITH Page I of 1
PERMIT
NOTICE
It is the responsibility of the applicant/permittee to see to it that the use described on the front of this permit complies with applicable codes and
requirements and that required inspections are requested. Failure to request inspections as listed below and obtain the necessary approvals before
progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the applicant's/permittee's
or property owners expense. At a minimum, the following inspections ARE REQUIRED by County Code:
1. FOOTING - when forms and reinforcement are in place and prior to placement of concrete—all structures, including manufactured homes.
NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zoning
regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from
the property line or the center line of the roadway right-of-way, whichever provides the greater setback from the center line of the roadway right-of-
way. Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County can own as much as 20 feet of
right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback provisions lies solely
with the permittee—neither Spokane County nor its authorized representatives assume any responsibility for the verification or location of your
property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require its relocation at the
owner's/permittee's expense.
2 FOUNDATION - when forms and reinforcement are in place and prior to placement of concrete.
3. FRAMING - after all framing, bracing and blocking is in place, and prior to concealing.
4. INSULATION - prior to the installation of drywall.
5. PLUMBING - after rough -in, before covering, and final.
6 MECHANICAL - rough -in of piping, before covering, metal chimneys before concealment, and final.
7. FINAL - when complete and prior to occupancy and/or use. Please provide 24 -hours notice. All permits require final inspection.
NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site plan)
required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access, on-site
drainage ("208 swales"), road Improvements, parking, and landscaping are common requirements of a permit/site plan which must be
completed prior to final approval of a building or issuance of a Certificate of Occupancy
8. MANUFACTURED HOMES - Final inspection required when complete, stairs, handrails, skirting, etc. installed, and prior to occupancy; completed
inspection record card must be available on site. Manufactured Homes must comply with the manufacturer's installation instructions.
9. SEWERS - prior to cover
10. RIGHT-OF-WAY/APPROACH - prior to placement of concrete, or, if gravel approach, after completion.
In addition to the above, any plumbing or mechanical systems or material which would be concealed by framing, drywall, concrete, etc., must be inspected
prior to cover. Check with the department for "special inspections" in conjunction with commercial projects.
FOR INSPECTIONS:
TO INSURE PROMPT SERVICE, PLEASE GIVE ONE WORKING DAY/24-HOUR NOTICE
PARTS OF YOUR PROJECT MAY REQUIRE PERMITS AND INSPECTIONS
FROM MORE THAN ONE AGENCY.
• Building, plumbing, mechanical and fire inspections, Department
of Building & Planning
477-3675
Construction in a flood plain, Division of Engineering & Roads
477-3600
• Electrical wiring, State Department of Labor and Industries
324-2640
• On-site waste disposal system, Spokane Regional Health District
324-1560
Road cuts for utilities or driveways, Division of Engineering &
Roads - 48-HOUR NOTICE REQUIRED
477-3600
or State Department of Transportation
456-3000
• Sewer connection, Division of Utilities
477-3604
or City Public Works Department
625-6300
PERMIT EXPIRATION AND REFUNDS
Unless otherwise noted, this permit will be considered null and void by limitation if the work authorized by the permit is not commenced oris stopped for
a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration. At a
minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within one year
of the date of expiration for one-half the original tee, subject to certain limitations—please call us if you have any questions.
All refund requests must be made in writing by the applicant/permittee (shown on the reverse) no later than 180 days after the date of fee payment.
Refunds of not more than 80% of the permit fee paid may be authorized when no work has been done under the permit. No refunds may be authorized
more than 180 days after fee payment.
MISTAKE?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous information in the permit, please
bring it to our attention immediately by filing a written request for correction within 10 working days of discovery. All such requests should be directed to
the Department of Building and Planning at the below address.
Spokane County Department of Building & Planning
1026 West Broadway Avenue
Spokane, WA 99260
Phone: (509) 477-3675 Fax: (509) 477-4703 TDD: (509) 477-7133 FORM 30-050202 BLDG PERMIT