2011, 04-29 Permit App: 11000706 Sprinkler SystemProject Number: 11000706 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/29/2011 Page 1 of 2 Project Information: Permit Use: SPRINKLER SYSTEM FOR A HOME Setbacks: Front Left: Right: Rear: Site Information: Plat Key: Name: Range Parcel Number: 45332.3803 SiteAddress: 3820 S MERCY LN Location:: CSV Zoning: R-2 Water District: Block: Contact: PATRIOT FIRE PROTECTION Address: 10005 E MONTGOMERY C - S - Z: SPOKANE, WA 99206 Phone: (509) 926-3428 Group Name: Project Name: Lot: District: Sout Owner: Name: CRAPO, DENNIS A & MELISSA A Address: 2602 N SULLIVAN RD SPOKANE VALLEY, WA 99216 SF Res Suburban District Area: 10,476 Sq Ft Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Fire District Review Permits: Released By: Originally Released: 4/29/2011 By: tharvey Contractor: PATRIOT FIRE PROTECTION Address: 10005 E MONTGOMERY AVE SPOKANE, WA 99206 Item Description City Fire Procssng Fee Hydraulic Sys 10-49 Hds Fire Safety Permit Firm: PATRIOT FIRE PROTECTION Phone: (509) 926-3428 Units Unit Desc 1 Select 1 Select Permit Total Fees: Fee Amount $37.00 $364.00 $401.00 Operator: JD Printed By: jmm Print Date: 4/29/2011 Project Number: 11000706 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 4/29/2011 Page 2 of 2 Notes: �� ��� �dt����4� �svM 1. ❑Drawings did not show ceiling elements (lights, fans, etc.). Sprinklers may need to be relocated to avoid ceiling elements during installation. Maximum spacing is 20ft x 20ft. Payment Summary. imimnmaimiguaam, Permit Type Fire Safety Permit Fee Amount Invoice Amount Amount Paid Amount Owing $401.00 $401.00 $0.00 $401.00 $401.00 $401.00 $0.00 $401.00 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: jmm Print Date: 4/29/2011 SPOKANE VALLEY FIRE DEPARTMENT Est. 1940 Mike Thompson, Fire Chief 10319 E. Sprague Avenue Spokane Valley, WA 99206 Phone (509) 928-1700 FAX (509) 892-4125 www.spokanevalleyfire.com April 29, 2011 Permit* 11000706 Project Address: 3820 S. Mercy Lane Project Description: NFPA 13D Sprinkler System — Ponderosa House Contractor: Patriot Fire Protection 10005 E. Montgomery Spokane Valley, WA 99206 926-3428 RE: Fire Suppression Shop Drawing Review Comments Attn: Carey Calkins The Spokane Valley Fire Department has completed a review of the Fire Suppression shop drawing submittal for the above referenced project with the following conditions: 1. Drawings did not show ceiling elements (lights, fans, etc.). Sprinklers may need to be relocated to avoid ceiling elements during installation. Maximum spacing is 20ft x 20ft. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call 928-1700 to schedule an inspection. Provide a minimum of 24 hours notice. If there are any questions please do not hesitate to call. (70 iced/G Traci Harvey Fire Protection Enginee Spokane Valley Fire De3artment Cc Spokane Valley Permit Center Q:\Dept Data Unshared\Prevention Unshared\Building Files\M - Master Property\Mercy Ln S 3820 Fire Suppression 13D.docx Project Number: 11000706 Inv: 1 • Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 3/25/2011 Page 1 of 1 Project Information: Permit Use: SPRINKLER SYSTEM FOR A HOME Setbacks: Front Site Information: Left: Right: Rear: Plat Key: Name: Range Contact: PATRIOT FIRE PROTECTION Address: 10005 E MONTGOMERY C - S - Z: SPOKANE, WA 99206 Phone: (509) 926-3428 Group Name: Project Name: . ....> w. .. WA,.", District: Sout Parcel Number: 45332.9069 Block: SiteAddress: 3820 S MERCY LN Location:: CSV Lot: Owner: Name: CRAPO, DENNIS A & MELISSA A Address: 2602 N SULLIVAN RD SPOKANE VALLEY, WA 99216 Zoning: R-2 SF Res Suburban District Water District: Area: 5.44 Acres Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Fire District Review Permits: Released By: Contractor: PATRIOT FIRE PROTECTION Address: 10005 E MONTGOMERY AVE SPOKANE, WA 99206 Notes Fire Safety Permit Firm: PATRIOT FIRE PROTECTION Phone: (509) 926-3428 (10-��. mac. \-A4c1Y-ctokc Cat c_t.c64-feiv-\ 64- Do IQ Payment Summary: Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulati b O f _ pe of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or in rovi{F'of; a violation of any of the provisions of the code or of any other state or local laws or ordinances. .00 Signature: Operator: JD Printed By: JD Print Date: 3/25/2011 Sp�u444hhhhh1 Community Development Department Permit Center 11703 East Sprague Avenue, Suite B-3 Spokane Valley, WA 99206 Tel: (509) 688-0036 Fax: (509) 688-0037 permitcenter@spokanevallev.orq (Staff Use Only) PERMIT NUMBER: \ \ -07 PERMIT FEE: FIRE SAFETY PERMIT APPLICATION SITE ADDRESS: 3820 S. Mercy dr. ASSESSORS PARCEL NO.: LEGAL DESCRIPTION: BUILDING OWNER NAME: Diamond Rock Construction MAILING ADDRESS: cm,: Spokane Valley STATE: WA zip: 99206 CONTACT PERSON NAME: Dennis PHONE: (509) 924-8964 FAX: CELL: CONTRACTOR NAME: Patriot Fire Protection INC. MAILING ADDRESS: 10005 E. Montgomery dr. cm: Spokane Valley STATE: WA. zip: 99206 PHONE: (509) 462-6818 FAX: (509) 462-6848 CELL: (509)370-1744 CONTRACTOR LICENSE No.: PATRIFP099CF EXPIRES: 10-5-12 CITY BUSINESS LICENSE NO.: NAME OF OCCUPANT OF STRUCTURE: Ponderosa House PHONE: FAX: CELL: CONTACT PERSON NAME: Carey Calkins PHONE: FAX: CELL: FIRE SPRINKLERS: Wet system NUMBER OF HEADS: 31 FIRE ALARM: PAINT BOOTH: TENT: BLASTING: DATE/TIME: OTHER: ABOVE/UNDERGROUND STORAGE TANK SIZE: DESCRIBE THE SCOPE OF WORK IN DETAIL: Patriot to install new sprinklers system in house. TOTAL COST OF PROJECT: $ DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subsequently approved before this application can be processed. Signature Date: 3/24/11 Method of payment: ❑ Cash ❑x Check Bankcard #: ❑ Visa ❑ Mastercard EXP: VIN#: Authorized Signature: Effective October 28, 2007 Page 1 of 1 H:\Common\JURISDICTIONS\PERMIT APPLICATIONS\Washington\Spokane Valley, City of\Fire Safety Permit App.l.doc PATRIOT FIRE PROTECTION, INC. EAST 10005 MONTGOMERY SPOKANE,WA 99206 HYDRAULIC CALCULATIONS FOR PONDEROSA HOUSE 3820 S MERCY DR. SPOKANE VALLEY, WA. 99206 REMOTE AREA 1 FILE NUMBER: 22-9578 DATE: MAR 31, 2011 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Residential Occupancy DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 2 HEAD CALC COVERAGE PER SPRINKLER: SSP 20X20 SQ.FT. HSW 12X12 SQ.FT. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 36.7 gpm TOTAL WATER REQUIRED (including hose): 36.7 gpm FLOW AND PRESSURE (@ BOR): 36.7 gpm @ 53.5 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: Patriot Fire Protection DESIGN/LAYOUT BY: Carey Calkins AUTHORITY HAVING JURISDICTION: Spokane Valley Fire Dept. SPOKANE VALLE1R [ t€: P Approved As Note; mate'__ CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 3808132110) HRS SYSTEMS, INC. TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/31/2011 W:\_2011\22-9578 DIAMOND ROCK\REMOTE AREA 1.SDF JOB TITLE: WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 88.0 62.0 1174.0 88.0 36.7 83.7 Required pressure is 4.2 psi (5%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 36.7 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 36.7 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 12.0 19.3 2 10.0 24.7 3 10.0 30.1 4 0.0 - - - - 38.4 101 0.0 K= 4.40 14.4 16.7 102 0.0 K= 4.90 16.7 20.0 TR 0.0 46.3 BOR 0.0 53.5 DC1 0.0 52.9 DC2 0.0 46.9 METER 1 0.0 78.1 METER 2 0.0 - - - - 73.1 - - - SOURCE 0.0 SOURCE 83.7 36.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/31/2011 W:\_2011\22-9578 DIAMOND ROCK\REMOTE AREA 1.SDF JOB TITLE: PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -16.7 1.010 PL 18.00 PF 2.3 101 0.0 4.4 14.4 16.7 6.7 150 FTG 5E PE 0.0 102 0.0 4.9 16.7 20.0 0.074 TL 30.55 PV Pipe: 2 -36.7 1.010 PL 12.00 PF 7.8 102 0.0 4.9 16.7 20.0 14.7 150 FTG 2T PE -5.2 1 12.0 0.0 19.3 0.0 0.318 TL 24.56 PV Pipe: 3 -36.7 1.010 PL 8.00 PF 4.5 1 12.0 0.0 19.3 0.0 14.7 150 FTG T PE 0.9 2 10.0 0.0 24.7 0.0 0.318 TL 14.28 PV Pipe: 4 -36.7 1.010 PL 12.00 PF 5.4 2 10.0 0.0 24.7 0.0 14.7 150 FTG 2E PE 0.0 3 10.0 0.0 30.1 0.0 0.318 TL 17.02 PV Pipe: 5 -36.7 1.010 PL 10.00 PF 4.0 3 10.0 0.0 30.1 0.0 14.7 150 FTG E PE 4.3 4 0.0 0.0 38.4 0.0 0.318 TL 12.51 PV Pipe: 6 -36.7 1.010 PL 16.00 PF 7.9 4 0.0 0.0 38.4 0.0 14.7 150 FTG ET PE 0.0 TR 0.0 0.0 46.3 0.0 0.318 TL 24.79 PV Pipe: 7 -36.7 1.380 PL 6.00 PF 0.6 TR 0.0 0.0 46.3 0.0 7.9 120 FTG ---- PE 0.0 DC2 0.0 0.0 46.9 0.0 0.105 TL 6.00 PV Pipe: 8 FIXED PRESSURE LOSS DEVICE DC1 0.0 0.0 52.9 0.0 6.0 psi, 36.7 gpm DC2 0.0 0.0 46.9 0.0 Pipe: 9 -36.7 1.049 PL 1.50 PF 0.6 DC1 0.0 0.0 52.9 0.0 13.6 120 FTG ---- PE 0.0 BOR 0.0 0.0 53.5 0.0 0.400 TL 1.50 PV Pipe: 10 -36.7 1.049 PL 45.00 PF 19.6 BOR 0.0 0.0 53.5 0.0 13.6 120 FTG 2E PE 0.0 METER 2 0.0 0.0 73.1 0.0 0.400 TL 49.00 PV Pipe: 11 FIXED PRESSURE LOSS DEVICE METER 1 0.0 0.0 78.1 0.0 5.0 psi, 36.7 gpm METER 2 0.0 0.0 73.1 0.0 Pipe: 12 -36.7 1.049 PL 5.00 PF 5.6 METER 1 0.0 0.0 78.1 0.0 13.6 120 FTG 2ET PE 0.0 SOURCE 0.0 SRCE 83.7 (N/A) 0.401 TL 14.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/31/2011 W:\_2011\22-9578 DIAMOND ROCK\REMOTE AREA 1.SDF JOB TITLE: NOTES (HASS): (1) Calculations were performed by the HASS 8.1 computer program under license no. 3808132110 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.016 gpm and a maximum imbalance at any node of 0.188 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 14.7 ft/sec at pipe 2. (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatV1v AlmChk DPV1v NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 PAGE: J MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee 1.010 2.51 6.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 WATER SUPPLY CURVE 96+ 1 1 1 880\ 1 \\ x \\ 1 \\ 80+ 1 72+ 1 \\ \\ \\ \\ \\ \\ \\ P 64+ R 1 E 1 S 1 S 56+ U I R 1 E 1 48+ ( I P 1 s 1 I 40+ I 32+ 1 1 * <-62.0 psi @ 1174 gpm Flow Test Point 24+ 16+ LEGEND " " 1 X = Required Water Supply 1 83.74 psi @ 36.7 gpm " 8+ 1 0 = Available Water Supply 87.96 psi @ 36.7 gpm If 0++-+---+----+ + + + + + + 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) WATER SUPPLY ANALYSIS N l0 ri N U) O 0 CO CO CJ) ri N 0 0 0 0 0 O O O O 0 0 CO lD C N 0 Kt c7 41 a x W cn u) a W --- a m -H -- Ca O O FLOW (GPM) VERTICAL SUPPORT AND RESTRAINT TR 11/4 Q 1 4�G BOR P(1TRIOT TO PROVIDE 1V4xtx1/z E 1 DIELECTRIC UNION PATrdOT START P0 Lnf (I AT BASE OFR SER itiT OWNER TO PROVIDE ADEQUATE WATER SOURCE TO MEET OR EXCEED HYDRAULIC REQUIREMENTS nRISER DETAILS A SCALE: b` 1'-0 AFCON #906 HORIZONTAL STABILIZE au AND RESTRAINT HANGER DETAIL SCALE NTS IT SS IMPORTANT ITO ENSURE SPRINKLER PIPING IS PROPERLY PROTECTED AGAINST FREEZING WHERE SPRINKLER PIPE IS INSTALLED IN UNHEATED AREAS. ANY SPACES OR VOIDS BETWEEN THE INSULATION AND THE JOISTS CAUSES THE WATER IN THE FIRE SPRINKLER PIPING TO FREEZE. REFER TO TENTING DETAIL FOR PROPER PROTECTION AGAINST FREEZING. CARE SHOULD BE TAKEN TO ENSUF �z RISER LEGEND MAX SPACING feet (m) B COACH SCREW ROD TRUSS (2X4) PATRIOT (1.7) 1. 0-300 PSI GAUGE ASSY INSIDE 6.0' 1 ®1 2. 11/47 WILKINS 350 DOUBLE CHECK ASSY ITTHREADED) 1' OPENING 2.0) v 3. VSR-SF FLOW SWITCH (THREADED) ION M ' 0-6 4. 1" AGF TEST AN DRAIN (1000) =i IIIi 1-1I 11.; L tr-fi L j'-1 IlE a 1 5. 11/4" CPUC ADAPTER it li a= 111 n�1I 1-lllu, SPRINKLER DROP 6. 1" SMOOTH BORE 45' ELBOW SPRINKLER LEGEND --1"RISER LOCATION W/ CHROME WALL PLATE r �"�I' s z i2 o w 6 "' ALL EI ECTRICAL ALL E 7. 6' ELECTRIC BELL (SYSTEM SENSOR 110 1 (3.0) 01 BY OTHERS B. 6 HEAD BOX W/SPARE HEADS AND WRENEHES 1" UNDERGROUND,` 17 32 SPRAY 341 RES 4.9K 155 SSP 1-F1 RES 414 v 155 HSW SECTION VIEW B BO Q Q1/2 1" 4�G BOR P(1TRIOT TO PROVIDE 1V4xtx1/z E 1 DIELECTRIC UNION PATrdOT START P0 Lnf (I AT BASE OFR SER itiT OWNER TO PROVIDE ADEQUATE WATER SOURCE TO MEET OR EXCEED HYDRAULIC REQUIREMENTS nRISER DETAILS A SCALE: b` 1'-0 AFCON #906 HORIZONTAL STABILIZE au AND RESTRAINT HANGER DETAIL SCALE NTS IT SS IMPORTANT ITO ENSURE SPRINKLER PIPING IS PROPERLY PROTECTED AGAINST FREEZING WHERE SPRINKLER PIPE IS INSTALLED IN UNHEATED AREAS. ANY SPACES OR VOIDS BETWEEN THE INSULATION AND THE JOISTS CAUSES THE WATER IN THE FIRE SPRINKLER PIPING TO FREEZE. REFER TO TENTING DETAIL FOR PROPER PROTECTION AGAINST FREEZING. CARE SHOULD BE TAKEN TO ENSUF BL'IAZEMASTERO PIPE SDR 13.5 (ASTM F442) 1 HANGER SPACING BOL CHORD MAX SPACING feet (m) B COACH SCREW ROD TRUSS (2X4) 5.5' (1.7) 1 LAYER VISQUEEN, 1ITACH 5.0) 6.0' TIGHTLY TO PREVENT SAG WHEN 2.0) COVERED WITH INSU ION M 0.0) =i IIIi 1-1I 11.; L tr-fi L j'-1 IlE SPRINKLER BRANCHLINE it li a= 111 n�1I 1-lllu, SPRINKLER DROP , JII I-,11 Li x..111 u: SPRINKLER LEGEND --1"RISER LOCATION L �, I'i1=L - J I- I. r �"�I' s z i2 o w 6 "' 1ililJy. v 1 (3.0) O • i" 1" UNDERGROUND,` 17 32 SPRAY E] Q 3/4" BY OTHERS SECTION VIEW 3 7 1 B 16 2 SIDEWALL Q Q1/2 BL'IAZEMASTERO PIPE SDR 13.5 (ASTM F442) 1 HANGER SPACING NO AL SIZE inche (mm) MAX SPACING feet (m) B COACH SCREW ROD 0.0) 5.5' (1.7) G CEILING FLANGE 5.0) 6.0' (1.8) N TOGGLE NUT 2.0) 6.5' (2.0) M 0.0) 7.0' (2.1) X 50.0) 8.0, (2.4) SPRINKLER LEGEND 65.0) 9.0, (2.7) s z i2 o w 6 "' 80.0) 10.0' (3.0) SCOPE OF WORK FIRE SPRINKLER GENERAL NOTE& PATRIOT TO INSTALL NEW RESIDENTIAL FIRE ALL HANGER ATTACHMENT TO BE PER HANGER DETAIL ON SHEET FP -1 SPRINKLER SYSTEM PER THE DRAWINGS. ALL NEW PIPING TO BE 1" CPVC UNO ALL NEW PIPING ON RISER TO BE 1" SCH-40 BLACK UNO ALL PIPING, HANGERS AND HEADS SPACING TO BE IN ACCORDANCE WITH NFPA #13 MAX SPACING ON F1 RES. 49 PENDENT TO BE 20X20 PER SPRINKLER MAX SPACING ON F1 RES. 44 HORIZONTAL SIDEWALL TO BE 12X12 PER SPRINKLER FTTTER TO ADD AND RELOCATE HEADS AS NEEDED TO AVOID CEILING MOUNTED OBSTRUCTIONS r -- W111 III PATRIOT START POINT I i I AT 1" OPENING PROVIDED BY OTHERS -h! I SEE RISER DETAIL FOR MORE INFORMATION 1I r- I11 I II I I; 1 DOMESTIC WATER LINE PROVIDED BY OTHERS j SEE SITE MAP FOR MORE INFORMATION �SITE MAR S O SCALE: NTS I DEME I� OPEN STRUCTURE UNDER STAIRS -Y I I I 1 I I I I I 1 I I I 1 I I I i I I -----------J V SLIDING GLASS I I I I v 4' 3` II n i 1 I II T i i I I I I 17'-1 �7 I I I I II 1 u - CL1 11 I II �I I I I I I i 1 i i m ly I i f I I I i 1 I I. i�j 1 1 I i I I I I I i I I I i I I e{I 11 N 1 kit I-L__I____i-_ I I i I I i 1 1 I I I I I I 3, 0? 41-3 15-10 2 it I i I %I -11f ' 1 I I I 1 I I i �I I i 11 I I i 1 1 1 I 1 N i,z' 9"n2 -- UD -4 ------------- I 01 - ---------- IAS1 LVA TEDLNGl i 140PE ISL0I?LORE I 1 ------- ('AGE -------- d❑_ �__!__ ----------------- REMOTE AREA #1 ----------------- .05/2 HEAD CALC. r -----------I - - - - FLOW ® BOR ------i-------- 1 ------------- 36.7 GPM @ PSI 53.5 ------ 1 --------- 1ST FLOOR LAYOUT SCAI= 1'-0 SPOKANE VALLEY FIRE xoved As V fed ey Date: HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W "STRAP E EYELET F FLUSH SHELL G CEILING FLANGE HI SIDE BEAM BRACKET K I SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W X Y Z STATE CERTIFICATION SPRINKLER LEGEND ea. [am „ !Y w SPRINKLER ORIFICE SIZES AND TYPE s z i2 o w 6 "' 2 16 8 6 2 SPRAY O O i/2 O • i" 3 4 17 32 SPRAY E] Q 3/4" 0 . 1^ 1 2 3 7 1 B 16 2 SIDEWALL Q Q1/2 1" DRY TYPE 2 • 1^ i^ ® . 2 -WAY EARTHQUAKE BRACE 4- WAY EARTHQUAKE BRACE TEMP RATINGZ rc o Yoi/2"� za �= z- z o W N o Q 165° -8- 212' 286° 350° Egg 500, 1" STRUCTURE TO CENTERZ LINE OF PIPE IN INCHES 1'• ®1/2' 1" JI 1^ FITTING LEGEND 1/2" (:p 1/2'• P PIPE -O -LET APPROVAL REQUIRED F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE OWNER TSN THREADED SHAPED NIPPLE SPOKANE VALLEY FIRE DEPT. SPRINKLER HEADS USED SYM MANUF MODEL - TYPE THREAD ORIFICE HEAD ESCUTCH TEMP QTY SIZE SIZE FINISH FINISH • RMQE RFS 49 SEMI RECD SSP I/2" 4.9K WHIE WHIE 155 26 REtM RES 44 SEM RECD 0 1/1 4AK WIRE WNIE 155 1 • RWABIE FIR SEMI RECD SSP 1/f 5.6K WME WHTE 2N 2 TOTAL 29 QUALITY CONTROL BY DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND 'FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE. PROVIDED By BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED By BY OTHERS DESIGN CRITERIA PER NFPA #13D PIPE NOTES SCH-40 BLK & CPVC IMPORT OR DOMESTIC U.G. TO BE PROVIDED BY OTHERS REVISIONS NO DATE BY DESCRIPTION RACT WITH: QDNTDIAMOND ROCK CONSTRUCTION 2602 N. SULLIVAN RD. SPOKANE VALLEY, WA 99216 DENNIS 509-924-8964 PRDJECT NAME: PONDEROSA HOUSE 3820 S MERCY DRIVE SPOKANE VALLEY, WA. 99206 PATRIFP099CF WWW.PATRIDTFIRE.COMDATRIW- cOreyc®patriotfre.com FIN - w OOOSE. MONTGOMERY! TEL (509) 462-6818