Loading...
2008, 06-27 Permit App: 08002383 Retro Fit, Egress WindowsProject Number: 08002383 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 6/27/2008 Page 1 of 2 Project Information: Permit Use: INSTALLING 2 RETRO FIT & 1 EGRESS WINDOW Setbacks: Front Site Information: Left: Right: Rear: Plat Key: 003150 Name: WEgg Contact: MCVAY BROTHERS Address: 11420 E MONTGOMERY C - S - Z: SPOKANE VALLEY WA 99206 Phone: (509) 928-4686 Group Name: Project Name: MICA PARK ADD AMENDED District: Sout Parcel Number: 45203.1821 Block: SiteAddress: 1117 S MICA PARK DR Location:: CSV Lot: Owner: Name: SINDLINGER, THEODORE G Address: 1117 S MICA PARK DR SPOKANE VALLE, WA 99206-3111 Zoning: MF -1 MF MDR District Water District: 101 SPO CO WATER DIST#3B Hold: ❑ Area: .00 Acres Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Permits: Released By - Originally Released: 6/27/2008 By: tmelbourn Contractor: MCVAY BROS CONTRS INC Address: 11420 E MONTGOMERY SPOKANE VALLEY WA 99206 Building Permit Firm: MCVAY BROS CONTRS INC Phone: (509) 928-4686 This Application: Total Project: Description Grp Type Notes Su Ft Valuation Su Ft Valuation 1&2 FAMILY R-3 VB WINDOWS 0 $2,533.00 0 $2,533.00 Totals: 0 $2,533.00 0 $2,533.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $83.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW < 7999 SQ FT 1 SELECT $33.30 Permit Total Fees: $121.05 Operator: jmm Printed By: jmm Print Date: 6/27/2008 Proj get Number: 08002383 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 6/27/2008 Page 2 of 2 Notes Payment Summary•Yn:.m. _ : E:to.,:� {- ,.:: _ ,m Permit Type Building Permit I M: . MIS .. }; Fee Amount Invoice Amount Amount Paid Amount Owing $121.05 $121.05 $0.00 $121.05 $121.05 $121.05 $0.00 $121.05 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: jmm Printed By: jmm Print Date: 6/27/2008 ' SpSkane Vlley EMERGENCY ESCAPE AND RESCUE EGRESS WINDOW *Minimum 20" wide clear opening *Minimum 24" high clear opening *Minimum 5.7 sq ft openable area **5.0 sq ft minimum @ grade floor *Top of sill maximum of 44" above finished floor 20' CLEAR MIN MINIMUM SIZE WINDOW FOR 20 IN. CLEAR WIDTH 41" CLEAR SILL HEIGHT 44' MAX 34' CLEAR • OPENABLE AREA 5.7 SQ FT MIN (5.0 SQ FT MIN GRADE FLOOR) • MINIMUM SIZE WINDOW FOR 24 IN. CLEAR HEIGHT 1 24" CLEAR MIN FLOOR Grade floor opening is a window or other openings located such that the sill height of the opening is not more than 44" above or below the finished ground level adjacent to the opening. / i i / / • OPENABLE �' AREA 5.7 SQ FT MIN \(5MIN CP RADE FLOOR) • • • i MINIMUM SIZE WINDOW FOR 20 IN. CLEAR WIDTH 41" CLEAR SILL HEIGHT 44' MAX 34' CLEAR • OPENABLE AREA 5.7 SQ FT MIN (5.0 SQ FT MIN GRADE FLOOR) • MINIMUM SIZE WINDOW FOR 24 IN. CLEAR HEIGHT 1 24" CLEAR MIN FLOOR Grade floor opening is a window or other openings located such that the sill height of the opening is not more than 44" above or below the finished ground level adjacent to the opening. WINDOW WELL *Minimum 36" x 36" *Minimum 9 sq ft clear floor area *Top of wall a maximum of 44" above the floor of the well *A guardrail is not required unless an exit way adjoins the well. *Provide drainage DEEP WELLS *If the top of the window well wall is more than 44" above the floor of the well, either a permanently fixed ladder or stair egress is required. *The ladder or stair may encroach a maximum of 6" into the required clear floor space. WINDOW WELL LADDER OR STAIR REQUIRED NET CLEAR DIMENSIONS WHEN FULLY OPENED TO PROVIDE 9 SQUARE FEET OF OPENING '/// //1/,:\\\ '/// '\\\'///, .\\\ 7/1% ‘\\\ '///• LADDER EGRESS *At least 12" in width *Rungs not more than 18" on center *Minimum 3" toe space *Permanently fixed *Non-combustible *Shall extend to top of wall LADDER OR STAIR PERMITTED TO ENCROACH MAXIMUM OF 6 INCHES INTO REQUIRED DIMENSIONS �-0 /// EMERGENCY ESCAPE OR RESCUE OPENING WITH FINISHED SILL HEIGHT BELOW ADJACENT GRADE \\\\ \\\'/// \\\"/// ,\\\ /1/ \\\'/// . \\\'/// \\\"/// , \\\'/1/ 36' MIN 36' MIN *Where bars, grills, covers, screens or similar devices are installed over emergency escape and rescue openings, they must be openable from the inside without the need of special knowledge or special tools, and the force to open them may not be greater than that required of the opening itself. JUN 2.5 14;4; rK 'v've6 Untitled Page 20 24 Fr G (480 2• 24 sFt5H 88 37 1 s Fr B 4 4 1 S F OH 74 1sFrOH Page 1 of 32 2l 22 EMERGENCY EGRESS **OUIREMENTS FROM SLEEPING ROOMS 1) NET CLEAR OPENING 5 7 SQUARE FEET GRADE FLOOR OPENING (MAX 44') 5.0 SQUARE FEET 2► NET CLEAR OPENING HEIGHT 24 INCHES 3) NET CLEAI; OPE NINGMOTH 20 INCHES FLOOR 41 MAX FINiSri1D SILL HEIGHT ABOVE F MERGE NC Y ESCAPE & RESCUE OPENING SHALL BE UPE RATIcN AL FROM THE INSIDE OF THE ROOM WITHOUT EH1 ISE'4 KEYS OR TOOLS 'FiEN INTERIOR ALTERATIONS. REPAIRS OR ADDITIONS ; <<? IHRINN A PERMIT OCCUR, OR WHEN ONE OR MORE E;'i, r E `IN( ROOMS ARE ADDED OR CREATED IN EXISTING LINOS. THE DWELLING UNIT SHALL BE PROVIDED V I H SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. ,IOKE ALARMS SHALL BE INTERCON- dr-CTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ARM WI -IL ACTIVATE ALL ALARMS. BEDROOMS, AREAS APPROACHING. BEDROOMS, VAULTED CEILING WITH RISE OF 24" & ON EACH FLOOR) iM 11\11 mAn evt. b G L — (?) Z >' E Jf\ A) ->( 1 ** TOTAL PAGE.02 ** PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING !NSPECTIONS C' 11-51'4FtUOINIC,?..itia-,1 r THESEiPLANSVIOSPITHKPT, (N THE .101k§RE THIS BUILpinaVv.g3,JECT TO FILO INSPECTIO(4 9PRRECTIONS Stiog:24-y! REVIEWED Fr ri 3aVIPLIANCE SPOKANE VAI ' E7-" DSON or