1988, 03-31 Permit: 88000641 Energy Code InfoSPOKANE PUNTY DEPARTMENT OF BUILDING OD SAFETY
NORTH811JEFpERSON
SPOKANE, WASHINGTON 99260
(509) 456-3675
I certify that I have examined this permit and state that the information contained in it and submitted by me or my agent to compilesaid permit/tand correct. I
addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and
ordinances governing this type of work will be complied with whether specified herein or not. I understand that the issuance of this permit and any subsequent inspection
approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any state or local law regulating construction, or as a
warranty of conformance with the provisions of any state or local laws regulating construction.
SIGNATURE OF APPLICATION
OWNER onAGENT DATE
PROJECT NUMBER= 88000641 DATE= 03/31/88 PAGE= 03
ISSUED PERMIT
*************************** ENEKGY
SITE STREET= 155.ee E MISSION AVE
ADDRESS= SPOKANE WA 99016
INFORMATION *************«»*************
PERMIT USE= SINGLE FAMILY RESIDENCE
NEW= X REMODEL= ADDITION=
ENERGY CODE=
APPROACH=
COMPLEXITY=
DE%CRIPTION
.
BASEMENT U
DECK
GARAGE
RESIDENCE
PARCELO= 18551-1909
CHANGE OF USE=
UTILITY= WWP
GROUP
-----
R-3
R-3
M -i
R-3
*****************«******* ENERGY CODE
CEILING, FLAT: g-38
CEILING, VAULTED: --��'
. `�
WALL
g. 24A
WALL' BELOW GRADE: R ^\
FLOOR OVER UNC. SPACE VI* (Z -3o
SLAB FLOOR PERIMETER: R-10
COMMENTS:
TYPE
----
VN
VN
VN
VN
PLAN REVIEU
%Q FT
-----
864
80
576
963
DOORS MAX. U -VALUE: 0'L41
GLAZING MAX U -VALUE:
GLAZING MAX AREA:
AIR LEAKAGE SYSTEM: STP
SPACE HEATING SYSTEM: .6p6E��0-*0
****v*x**)************x*),—;x*********»***A:***»********»**»******************
I HAVE BEEN ADVISED OF THE FINANCIAL INCENTIVES AVAILIBLE FOR THE STRUCTURE
DESCRIBED ON THI% PERMIT, AND THAT THE ENERGY CONSTRUCTION MEASURES FOR
WHICH THE INCENTIVES WILL BE PAID ARE A REQUIREMENT OF THIS PERMIT, AND THAT
THE STRUCTURE MUST RECEIVE FINAL APPROVAL BY MARCH 31, 1989 TO RECEIVE THE
INCENTIVE PAYMENT. I ALSO UNDERSTAND THAT NEITHER THE BONNEVILLE POWER
MINISTRATION NOR NOR %POKANE COUNTY MAKE ANY WARRANTIES AS TO ACTUAL ELECTRICAL
SAVINGS TO BE REALIZED' OR ANY OTHER EXPRESSED OR IMPLIED WARRANTY CON-
CERNING THE MATERIALS EMPLLY[D T|4E CONSTRUCTION OF THE STRUCTURE,
HAVE BEEN ADVISED OF AND INT -ND TO COMPLY WITH THE NORTHWEST ENERGY CODE
REQUIREMENTS PERTAINING TO FORMALDEHYDE EMISSIONS STANDARDS FOR STRUCTURAL
COMPONENTS, AND HAVE RECEIVED A COPY OF EXHIBIT 9(A) WHICH DESCRIBES THESE
REQUIREMENTS,
�� � /e?"
_-�� ��'
*»*****»*4**�*****ft****k******** -HANK YOU **«*****************�*ii«***,...»****
•
INSP-!Dr"...
DATE
40
G-1
6-7
--4.c'
"7' (7
-----
y-
-- --._2
------
—
..
-
-
Rt33`/1
•- -� ViD
PLBM
i
I
MOBILE
HOME
DEMO
y
Race
G
U
th
I I
PKOJ[[l NUnBER= 38O,0611110
INVUED PERlT
**** ****^* *********** ENLR�\ I�F1RMAT'PN
.
~75/7
411 JITE
E MI%ION AVE 1O5�i i`O?
ADDRESS,, SPOKANE WA Y?0i6
PERMIT U%E= SINGLE FAMILY RESIDENCE
NEW= X
REMODEL=
ENERGY CODE= KikArOZ..
APPROACH= PW5c�tir-riap.
COMPLEXITY=
ADDlTION=
nE:::CP[PTIGN
BASEMENT U
�ECK
RESIDENCE
�HAN�E OF USE=
UT[LlTY� WWP
*4*******»*»**'*.Jf-***�**11 ENERC.:(Y CODE
CEILING, FLAT:
CEILING, VAULTED.
WALL:
WALL, BELOW GRADE
FLbOR OVER UNC. SPACE:
411%LAB FLUOR FERIMETER:
COMMENTS:
TYPE %Q FI
Vh
VN
VN
57�
*1,:*°*******4.***v*****11:*"*
DOOR2 MAX. U -VALUE:
GLA7ING MAX i| -VALUE: 0.4c,
C,LAZING MAX AREA: \��^
AIR LEAKAGE SYSTEM �_T()
%PACE HEATING SYSTEM. E-i_eLT.Fec*4)
v*****k*************41*************v**************,*******x«***:P.******
l HAVE BEEN ADVISED OF THE FINANCIAL INCENTIVES AVAILIBL[ FOR THE STRUCTURE
DESCRIBED ON THIS PERMIT' AND THAT THE ENERGY CON4TRUCTION MEASURES FOR
WHICH THE INCENTIVES WILL BE PAID ARE A REQUIREMENT OF THIS PERMIT, AND THAT
THE STRUCTURE MUST RECEIVE FINAL AFPRO/AL BY MARCH 3i, i989 TO RECEIVE THE
INCLN/IVE PAYM[NT, I ALSO UNDERSTAND THAT NEITHER lHE BONNEVILLE POWER AD-
MINISTRATION NOR SPOKANE COUNTY MAKE ANY WARRANTIES A% TO ACTUAL ELECTRICAL
SAVINGS TO DE REALI:EE, OR ANY OTHER EXPRESSED OR IMPLIED WARRANTY CON-
CERWAG THE MATERIALS EMPLOYED IN THE CONJ7RUCTTON OF THE %TUCTURE.
I HAVE BEEN ADVUED OF AND INTEND TO COMPLY WITH THE NORTHWEST ENERGY COD[
REQUIREMENTS PERTAINING TO FORMALDEHYDE EMISSIONS STANDARDS FOR STRUCTURAL
COMPONENTS, AND HAVE RECEIVED A COPY OF EXHIBIT c:'(A) WHICH DESCRIBES THESE
REQUIREMENTZ
•
APPLlCANT __
/'
----'--' --------'--'
/ AUTH]RIZED OFF:.CER
/
DAlE
v************************* THANK YOU *******11::),:.* *»*****************
NORTHWEST ENERGY CODE
Organization of File for Project No.
Site Address
0- 18523 rnl%totl A4
DESCRIPTION
DATE FILED
- INITIAL
VERIFIED AT/
CLOSE OUT - INIT
COMMENT SHEET
ONE SET OF APPROVED
PLANS
3-3I-88
ONE COPY OF THE
BUILDING PERMIT
3-3)--88
THE PLAN REVIEW
CHECKLIST
3-31•-38
PLAN REVIEW NOTES
WATT -SUN SUMMARY
REPORT
ORIGINALS OF
CORRECTION NOTICE
3 - 3)-S8
19 oe
ONE COPY OF THE
INSPECTION REPORTS
THE INSPECTION
CHECKLIST
ORIGINAL OF THE
SIGNED PERMIT HOLDER'S
CERTIFICATION
10.to. 88
VERIFICATION OF RADON
MONITORING OFFER
9-0,00
ORIGINAL OF THE
REQUEST FOR
INCENTIVE PAYMENT
/6 •
8
REQUEST FOR INCENTIVE PAYMENT
The file has been reviewed for project number 86 --G1 The
building is a 5(NGc CP/Yl1l_t residential building located at
e l6SIS (4(s&toN
The necessary information is in the file and the permit holder
has qualified to ieceive a builder incentive payment.
The total area of conditioned floor area is sF The
payment amount calculation is:
IE327 S :...4 o.s
PL
,The permit holder is
179es • cos
1 o0
( 13.3 cag
Ke•AU ; aNsm.uc.--nor- .
fo.'411 -;203''oTl: oltGNfrpvs
wit - t107-7:
*****************************************************************
Request by .SUN1 PIASLAnsio
Building and Safety.
, staff, Spokane County:
;:To::;- Kra LI K---CL2JS-(12uCTIc -\
Check No. •I, /`�
2
2
wwaIX 0a
L1<00(•-•
L�zU
°cfHZZ0
1-4 00, 00.0
a
v
U
z
a
U
0
O
•
Oa
•
i
Descriptions@ / Comments
alb
CJ N
+-IO
> L
O 7
X c
0 i
rl
Value Total Time
(Minutes)
S
U
6
i
FOUNDATION
Heated Slab
Unheated Slab
Basement
Crawlspace
FRAMING.
Ceiling
Doors
Floor
windows
Walls
Vapor Barriers
AIR-TO-AIR HEAT EXCHANGER
-a�
y
Ca
X
.
CC
CO
F
w -
3
F i
i
x,
INFILTRATION CONTROL
SPACE HEATING SYSTEM
I NOT,T.V'TT.T.N7A
U
2
F
.Z',
U
ti
0
m
0
0
z
0
C
C
Ol
U
L
tti
0
0
•
0
u
N
3
H
F
C
ti
.0
v
II
y
3
0
C
3
>
CJ
c
N C
en
II
1:4 w
4
C O
0.
O 6I
H >
Oh O
.0
% 0
W c
as required.
0
•-4
0.
a
m
O
C
C •
m c
r 7
O. L.
z 1 - •
.N
0) L
C.)
co h F
a O 3
PERMIT HOLDER'S CERTIFICATION
The undersigned verifies that they were made aware of and advised
of the Northwest Energy Code requirements at the time of issuance
of permit number f38 -6-qt for the residential building
located at fl t ESI S M(ss(otJ
Further, the undersigned certifies that the building stated above
meets the requirements of the Northwest Energy Code pertaining to
formaldehyde emissions of structural panels.
Further, the undersigned certifies that no incentive payment has
been or will be received from any Super GOOD CENTS Program for
this building.
Permit Holder
Witness:
Au
40,/,.kr
Date
/2 .//.06
orized Officer Date
Drpartment of Building & Safety
1
•
•
•
•
* SLAB INSPECTION - PRIOR TO PLACING SLAB
Job /less
County of Spokane Energy
Northwest Energy Code Inspections
BUILDER/INSPECTOR CHECKLIST 456-3675
GRAVEL BASE: A 4 inch thick coarse -grade gravel base shall be in place.
PERIMETER INSULATION: All slab perimeters within 24 inches of the final exterior grade shall be insulated to at least
R-10. Insulation shall be 24 inches in length overall and installed in an approved manner.
* INSULATION AND SEALING INSPECTION
APPROVED PLANS are available on the job site.
_ WINDOWS AND DOORS: All windows and doors shall be as specified on the approved plans. The rough opening around jambs,
sills and headers shall be sealed to prevent air infiltration. These areas may be either caulked or foamed, but must be
sealed airtight.
SOLEPLATE CAULKED: Soleplates of walls shall be caulked or glued to the floor.
PLUMBING AND ELECTRICAL PENETRATIONS: All holes in the buiding envelope shall be sealed to prevent air infiltration.
Where electrical wiring passes horizontally through a wall stud, no sealing is required unless that stud penetrates the
building "envelope." Electric boxes throughout the building shall either have the holes and edges sealed or be provided
with plate gaskets. Rim joists, mudsills and plumbing stacks shalt be sealed.
WALL. INSULATION: All wall cavities shall be fitted completely to the required insulation value. Batts shall not be
compressed. Batts must be cut to fit around wires, pipes and outlet boxes. Kraft or foil vapor retarders must be
face -stapled.
FLOOR INSULATION: Floor insulation shall be installed to the required R -value, and shall be supported in an approved
manner with twine, wire, "Tyvek," netting, etc. Avoid compressing the insulation.
CEILING INSULATION: If eave vents are used, approved baffles shall be in place to permit adequate ventilation through
eave vents. Blown insulation may not be used if the ceiling slopes more than 2-1/2 in 12.
DUCTS: Ducts shalt be sealed at joints and corners with duct tape or sealant. Ducts outside of the conditioned space,
except exhaust air ducts, shall be insulated to R-11. Exhaust air ducts shall extend to the exterior of the building.
VAPOR RETARDERS: A vapor retarder is required on the warm side of insulation in walls, floors, and ceilings. Approved
materials include: 6 mil. polyethylene, Kraft or foil paper face -stapled, exterior grade plywood and certain flooring
materials.
CRAWL SPACE: Screened ventilation openings shall be provided at a rate of not less than one square foot for each 300
square feet of under -floor area.
• •
* FINAL INSPECTION (ENERGY)
APPROVED PLANS are available on the job site.
MECHANICAL SYSTEMS: All mechanical systems will be checked for correct operation and labeling of controls.
L'/ Heaters shall be sized as shown on the approved plans.
L./Exhaust fans shall be properly located and shall be properly rated for size and noise.
Exhaust ducts shall be provided with a tight -fitting backdraft damper.
The whole house exhaust fan shall be controlled to operate automatically as well as manually.
Make-up air intakes shall be properly located and sized.
WEATHERSTRIPPING:
V/ Weatherstripping shall be aligned for proper seal on exterior doors, including doors into unheated spaces. Door
threshold or sweep shall be properly adjusted.
L Attic hatches and interior crawlspace access hatches shall be weatherstripped and insulated.
Windows shall be weatherstripped and locking mechanism checked for proper function.
Electrical switch and outlet plates throughout the building shall be fitted with gaskets, unless the boxes were sealed
prior to the insulation inspection.
ATTICS:
J/ Insulation shall be of thickness specified by the manufacturer to comply with required R -values.
PLUMBING:
Hot water heaters shall meet the ASHRAE 90A-80 specifications.
L/ Showers shall be equipped with flow restrictors allowing a maximum flow of 2.75 gallons per minute per shower head.
FIREPLACES / WOOD STOVES:
p Fireplaces and wood stoves shall be
i r
ep equipped with "tight -fitting" metal or glass doors_
A combustion air intake shall be ducted directly into the firebox. The intake duct shall be at least six square inches
in area and shall be equipped with a readily accessible, operable tight -fitting damper.
CRAWL SPACES:
A ground cover of 6 mil. black polyethylene or equal shall be installed on all crawl space floors. Joints shall be
lapped at least 12 inches.
INDOOR AIR QUALITY:
During the final inspection of occupancies which are eligible for incentive payments, the energy code inspector will
leave a pre -paid postcard, which offers a free radon monitor, and a backgrounder booklet from BPA about indoor air
quality.
C7- /
•