Loading...
1992, 12-01 Permit: 92007723 Energy Code InspectSPOKANE COUNTY DEPARTMENT OF BUILDINGS TE cc .S DDRESS .(i ma -c‘ o PERMIT :0 0 0 71223 o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST 0 o APPROVED FOR COVER BY 0 0• 0 0 0 0 0 0 o • e- I910WS & DOORS PER PLANS 6 AADVANCED FRAMING: WALLS . CEILINGS_ -e-WALL INSULATION: R- / o VAULTED CEIUNG: R-_ eIBATT INSTALLATION TECHNIQUES o WINDOWS & DOORS CAULKED oO�LEPLATE CAULKED 6PLU MBING//ELECTRICAL PENETRATIONS CAULKED o SEALED DUCTWORK e-E�CI-IAUST FANS/DUCTS INSTALLED a-F€CESSED UGI -ITS o -VAPOR RETARDERS: WALL CEIUNG erAITIC VENT BAFFLES o COMBUSTION AIR DUCTS INSTALLED o CRAWLSPACE VENTILATION bUN FAN CIRCUIT APPROVED FOR COVER BY se—S1PV DATE 73 ECHANICAL SYSTEMS BATH EXHAUST HEN EXHAUST UTOMATLC WHOLE HOUSE EXHAUST AKE-UP AIR INTAKES UCTWORK QUI • MENT INSTRUCTIONS EATING FUEL SYSTEM TYPE: r DON MONITOR ERIAL NUMBER257 S / y o-WtATHERSTRIPPING o-f16ORS & WINDOWS e //C & CRAWL ACCESSES o -SWITCH & OUTLET COVER PLATES 0 o INSULATION o FLOOR R- o.AITIC R- 3 o BELOW -GRADE WALLS R p B TT INSTALLATION TECHNIQUES o PLUMBING o -WATER HEATER PAD o SHOWER FLOW o FIREPLACE/WOODSTOVE o FIREPLACE DOORS o FLUE DAMPER o COMBUSTION AIR o CRAWLSPACE GROUND COVER o CRAWLSPACE VENTILATION e .-FIX-6AW�N VENT & LABEL WATTSUN 5.1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/19/91 -4., FILE: B:\CALSPLIT. WS Pian Reviewed By: D. Fenton (509) 482-4061 This plan review is provided for information purposes only, and does not guarantee compliance with local, state or federal codes or requirements. Mai.1 : Builder: HOMESTEAD CONSTRUCTION Address: The PROPOSED design HOUSE ID: CAL SPLIT A Analyst: DF Jurisdiction: Utility: WWF' Floor Area: 1984 ft2 Weather Data: Spokane, WA Climate Zone: 2 *COMPLIES* COMPONENT PERFORMANCE ENERGY BUDGET" REFERENCE DESIGN Component with 1991 WA REFERENCE 319 5.15 BG Wall BG Slab Floor Glazing @1.5/. Doors AG Wall Ceiling Infiltration PROPOSED DESIGN COMPONENTS Component BG Wail BG Slab Floor Glazing @12i: Doors AG Wall Ceiling infiltration Description State Energy Code. R19 batt 3.5' depth R30 unvented Joist 16oc **WF' VINYL 2 GL LOW E Metal R-5 base case R19 STD Lap Wood R49 blown Attic STD baffled Standard Air Sealing PROPOSED 31.6 Stu/hr-F 5.34 kWh/ft2-yr Reference Value X Area = UA U-0. 041 F-0.640 U-0.029 U-0.400 U-0.200 U-0.044 U-0.07.1. 462 18.9 132ft 84.5 77;2 0.9 297.6 119.0 20.0 4..0 1368 60.2 1008 31..2 Reference UA 319 Vai;lue X Area 1J-0.041 F-0.640 U-0. 029 U-0. 390 U-0. 190 U•-0. 062 U-0.027 ACH-0.750 = UA 462 18.9 132ft 84.5 32 2.3}7.0 ?0.0 1429 1008 0.9 92.4 L ; . 8 88.6 27.2 12976ft3 ( 78.6) Proposed UA 316 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 WAr-TSUN 5.1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/19/9.1. FILE: E+:\CALSPLIT.WS HOUSE 1D: CAL SPLIT A Struc Mass Light Frame, Sheetrock walls M- . ci�>C► 1984 5952.0 HEATING/COOLING/VENTILATING SYSTEMS Heating System Type: Make: Model: PROPOSED Electric: Zoned System Efficiency: 100 Y. Modified Efficiency: 100 '/. Heating Load(at 66F dt): System Size: Maximum Size @150/.: 29772 E+tu/hr 9.7 kW 13.1 kW Average Annual Heat: 13774 kwh Annual Cost: 758 Ventilation Type: Non -Heat Recovery Option: Option 1 Cooling Load (at 12F dt) : 24796 Btu/hr Recommended Size C125"/.: 2.9 tons Solar Access: Partially Shaded GLAZING ORIENTATIOu South: Southeast: East: Northeast: PROPOSED 59.2 ft2 0.0 59.2 0.0 North: Northwest.: West: Southwest: PROPOSED 59.2 ft2 10.00 59.2 0.0 Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. Page 2