2011, 04-07 Duct Leakage Affidavita e S' u:- 1l s .VVASFi11GION STATE UNIVERSITY EXrENSR7N ENERGt PROGRAM Duct Leakage Affidavit Permit #: (t - 0 3_2 3 ^� C House address or lot number: / . ( J ile7 b cu... r City: 5' ` o (G ww f.-1/41l� Gal et zip: Cond. Floor Area (ft2): \ "75\3 _Source (circle one): Estimated Measured ❑ Duct tightness testing is not required for this residence per exceptions listed at the end of this document Air Handler in conditioned space? 0 yes Jno Air Handler during test? Oyes ❑ no Circle Test Method: Leakage to Outside Maximum duct leakage: Post Construction, total duct leakage: (floor area x .08) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .06) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .06) = YTt� FFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .04) = CFM@25 Pa otal Leakage 37 Test Result: °N CFM@25Pa A 5r/o /0 U • Ring (circle one if applicable): Open 1 t('S\\"' 2 5 3 VLA LA`r 4e c Duct Tester Location: O,n 4 Ks 'K ft \' f v\ Pressure Tap Location: ti , .%.4%j .5 :,. a ? I / I certify that these duct leakage rates areaaccurate and determined `using standard duct testing protocol. r 4 0`4‘ I— r, til 1 Amin. (.p Technician: Li I Q— p r Owl 1 t CS g 5 o3 Company Name: Technician Signature: Date: Li/ V.2el( Phone Number: 5 O `Z$O038 Washington State Energy Code reference: . 503.10.3 Sealing. All ducts. air handlers, filter boxes, and building cavities used as ducts shall be sealed. Joints and seams shall comply with Section M1601.3 of the International Residential Code or 603.9 of the International Mechanical Code. Duct tightness testing shall be conducted to verify that the duds are sealed. A signed affidavit documenting the test results shall be provided to the jurisdiction having authority by the testing agent. When required by the building official. the test shall be conducted in the presence of department staff. Exceptions: 1. Duct tightness test is not required if the air handler and all ducts are located within conditioned space. 2. Duct testing is not required if the fumace is a nondired vent type combustion appliance installed in an unconditioned space. A maximum of six feet of connected ductwork in the unconditioned space is allowed. All additional supply and return duds shall be within the conditioned space. Ducts outside the conditioned space shall be sealed with a mastic type dud sealant and insulated on the exterior with R-8 insulation for above grade ducts and R-6 water resistant insulation when within a slab or earth. - Duct Testing Calculator (New Construction) House address or lot #: Conditioned Floor Area: Duct tester location: Pressure tap location: Ring (if applicable): -has S rn o ` 1 ki 9 l,.A....j 00c -Cmc° ,oCc- ` C,Od19S- e.,4oc-v\.. N".6/..5 5,.,,.pLi Open ❑ 1 ❑ 2 X 3 ❑ At Rough -in (Total Leakage) Test Method Standard' Calculated Target Test2 CFM25 Air Handler Present 5 6 CFM25 per 100 sf of CFA 'v qCI Air Handler not Present <_ 4 CFM25 per 100 sf of CFA Post Construction Test Method Standard' Calculated Target Test2 CFM25 Air Handler Present (Total Leakage) 8 CFM25 per 100 sf of CFA Air Handler Present (Leakage to Exterior) 6 CFM25 per 100 sf of CFA 1. Test results must comply with one of the Standards options. 2. Test CFM25 must be equal to or Tess than the calculated target. Air Leakage testing Calculator (Blower Door Test) Standard Tested CFM50 Test Result (SLA) 0.00030SLA ((CFM50X 0.055)/(CFA X144)) 00c -Cmc° ,oCc- ` C,Od19S- ` 600 19- , i -HI )c 1,49 -C�o Glossary Rough -In: After installation of the complete air distribution system but before installation of insulation and sheet rock. Allows for access to all duct seams and connections for re-evaluation of seal integrity if standard is not met in intitial test. Post Construction: At or near final inspection. The home must be complete enough to pressurize the home to 25 pa. Total Leakage: Aggregation of the entire systems duct leakage in a duct test. Leakage to Exterior: Aggregation of all duct system Teaks to the exterior of the CFA in a duct test. CFA: Conditioned floor area CFM25: Cubic feet per minute of air leakage at 25 pascals of pressure CFM50: Cubic feet per minute of air leakage at 50 pascals of pressure Pascal (pa)- Unit of pressure SLA: Specific leakage area