2006, 03-14 Permit App: 06000827 GarageProject Number: 06000827 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 3/14/2006 Page 1 of 2
Project Information:
Permit Use: 18X20 garage
Setbacks: Front
Site Information:
Plat Key: 002044 Name: GREENACRES IRR DISTRICT A
Left: Right: Rear:
Contact: TURNER, BERNARD
Address: 17113 E MISSION AVE
C - S - Z: SPOKANE VALLEY, WA 99016
Phone: (509) 928-2951
Group Name:
Project Name:
District: East
Parcel Number: 55073.1446
Block:
SiteAddress: 17113 E MISSION AVE
Location:: CSV
Zoning: UR -3.5
Water District:
Urban Residential 3.5
Lot:
Owner: Name: TURNER, BERNARD
Address: 17113 E MISSION AVE
SPOKANE VALLEY, WA 99016
Hold: ❑
Area: 3.00 Acres Width: 315 Depth: 357 Right Of Way (ft): 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:
Review
Building Plan Review
Released By
Landuse/Zoning/HE Conditions
Permits:
Relea
Operator: AMB Printed By: AMB Print Date: 3/14/2006
Project Number: 06000827 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 3/14/2006
Contractor: OWNER
Description Grp Type
GARAGE U-1 VB
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Notes:
Payment Summary:
Permit Type
Building Permit
Notes
owner built
Building Permit
Page 2 of 2
Firm: OWNER
Phone: (000) 000-0000
This Application:
So Ft Valuation
360 $6,840.00
Totals: 360
Units Unit Desc
1 SELECT
1 SELECT
1 SELECT
$6,840.00
Permit Total Fees:
Fee Amount Invoice Amount
$199.45 $199.45
Total Project:
Su Ft Valuation
360 $6,840.00
360 $6,840.00
Fee Amount
$139.25
$4.50
$55.70
Amount Paid
$0.00
$199.45
Amount Owing
$199.45
$199.45 $199.45
$0.00
$199.45
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB
Print Date: 3/14/2006
BUING WORKSHEET
fir`',itt�SlnIL Valley CommunitPERMITyAPPLICATION Development Department
i J Building Division •
MAR 1 11707 E. Sprague Avenue, Suite 106
YSpokane Valley, WA 99206
IP)) „{, f, ii ,,,, u kr er e: (509) 688-0036; Fax: (509) 688-0037
REQUIRED SITE INFORMATION
Street Address: /71/3 �isslo.tJ soota.fr', it . yi9, 'e) 99O/46'
Assessor's Tax Parcel Number(s): .5507.x. /-4z-'4'
Legal Description: 4-Xn64/4,4'5
PERMIT DESCRIPTION: sTo,Q e sf eat - /doe, o/ ,c.Q. M
Building Permit
❑ Relocation
❑ Change in Use n Grading ❑ Manufactured Home
❑ Tenant Improvement n Fire Safety ❑ Other
OWNER/APPLICANT INFORMATION
Owner .SeiZ,t/.9, ci 7e:;, e/V e ? 1 1 Applicant:
Phone: z1/3-_,154.5"/ Fax: 9,19-108 5G Phone: Fax:
Address: , ,o, ,..q.0),- 8/Y Address:
/w,ve \Vie ),g• 990/G
'City State Zip Code City State Zip Code
❑ Contractor: 06/./AUv.' ❑ Architect:
Phone: Fax: Phone: Fax:
Address:
Address:
City State Zip Code City State Zip Code
Contact:
Spokane Valley Bus. Liscense #: Contact:
WA State Contractor License #:
PERMIT/BUILDING INFORMATION
HEIGHT TO PEAK: .
DIMENS)ONS:
Z
OR
# OF STORIES:
%
MAIN FLOOR TO SQ. FTG:
2� SQ. FTG:
UNFIN BASEMENT SQ. FTG:
FINISHED BASEMENT SQ. FTG:
GAFS,1SO. FTG:
DECK/COV. PATIO SQ. FTG:
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
HEAT SOURCE:
# OF BEDROOMS:
TOTAL HABITABLE SPACE:
IMPERVIOUS SURFACE AREA:
COST OF PROJECT:
_ 4-0g, ° °
30% SLOPES ON PROPERTY:
SEWER OR ON-SITE SEPTIC
SYSTEM?
iv,
'"r"URr ! HOME
Width: Length:
Manufacturer:
Year:
Pit Set:
Previous Address:
Proposed Use:
RELOCATIO
FIRE SAFETY
Fire Sprinkler. # of Heads: Fire Alarm: Paint Booth:
Tent: Fireworks Display: Blasulg: Date/Time:
Valuation: Above/Underground Storag - Tank Size:
WASHINGTON TATE NON-RESIDENTIAL ENERGY CODE
Plans Examiner:
Address:
Inspector.
Address:
Phone: Fax:
9 BOLTING ❑ CONCRETE
city
Phone:
State
Fax:
Zip
City
State Zip
DIAL INSPECTIONS
9 REINFORCEMENT 9 WELDING
Firm Name: Phone: Fax:
Inspector(s):
DISCLAIMER
The permitee verifies, acknowledges ar d agrees by their signature that: 1) If this permit is for construction of or on a
dwelling, the dwelling is/will be served , y potable water. 2) Ownership of this City of Spokane Valley Permit inure to the
property owner. 3) The signatory is ti aroperty owner or has permission to represent the property owner in this
transaction. 4) All construction is done in full compliance with the City of Spokane Valley Development Code.
Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley
Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances.
Ownership of resulting development rights granted by any issued permit inure to the pro•erty owner.
Print Name ,/4,c2,v,q-zz,J 7-i;,twez
Signature
Method of Payment: (Faxed permit applications will only be accepted with major bankcard)
0 Cash ,a Check
Bankcard #:
Authorized Signature: ..�
0 Mastercard
Expires:
❑ VISA
VIN#:
0 Other
PLEASE ASK A STAFF PERSON FOR MORE INFORMATION 1
Spokane
Valley
Minimum Site Plan
Requirements
Effective November 5, 2003, the following are the City's
minimum requirements for site plans submitted at time of
building permit for residential and non-residential development:
•
•
•
•
Site Address
Scale
North Arrow
Legal Description (for non-residential development and
multi -family development only)
Abutting Street Names
Actual Property Configuration
Property Dimensions, Property Lines and Property Corners
Property Square Footage
Percent of Building Coverage (non-residential and multi-
family development only)
Proposed number of stories of new primary or accessory
structures
Actual Structural Footprint for proposed and existing structures
with dimensions and square footage also identified
Actual Structural Footprint of all existing and proposed
accessory buildings with dimensions and square footage also
identified
Proposed and existing building setbacks
Distances (in feet) between existing and proposed primary and
accessory structures
Location of existing or proposed driveways
Number, location, and dimensions of on-site parking spaces and
drive aisles (non-residential and multi -family development
only)
Location, type, size and percent of on-site landscaping (non-
residential and multi -family development only)
c
Tom Scholtens, Building Official
Date
6.01
Assessor Parcel # _ 5070 number given on Harp)
GPS Controlled Section
(x1 7 0 0
1 Inch = 2 00 Fell
200
12006
City of
SPOKANE VALLEY BUILDING DEPARTMENT
11707 E. Sprague Avenue #106, Spokane Valley, Washington 99206 - Tel 509-688-0036 - Fax 509-688-0037
Following is a typical cross-section for a residential garage. It may not represent the proposed project If you are using this detail
as a porton of your plan submittal, please complete the requested information in the boxes provided on both sides of this sheet
This completed sheet, along with any additional information needs to be submitted with your apIlication and be on site at the time
of inspection.
PROTECTION AND OPENINGS BETWEEN
DWELLINGS AND PRIVATE GARAGES SHALL HAVE:
1) MATERIALS APPROVED FOR ONE HOUR FIRE
RESISTIVE CONSTRUCTION ON THE GAR e. ,E SIDE:
• 5/8" TYPE 'X' GYP BOARD (HABITABLE SPACE ABOVE)
' 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING)
2) OPENINGS BETWEEN GARAGE AND RESIDENCE
SHALL BE EQUIPPED WITH SOLID WOOD DOOR, SOLID OR
HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8",
OR 20 MINUTE FIRE RATED DOORS.
ALTERNATE FOUN
ACCESSORY BUILDINGS F
400 SQ. FT. TO 3000 SQ. FT.
SECTION A -A
N FOR
N
4
6" MIN.
L
IIII®IIIII
3111- ._2 :MIN
1--12"--1
(2) ¢4 RE
MW
NOTE:
Diagonal wall bracing required on
each comer and every 25 feet of wall.
Wails within 3 feet of a property line or
within 6 feet of a dwelling must be 1 hour
rated. (5/8" type 7C gypsum sheathing
on both sides of wall). Openings are not
permitted in these walls. Garages over
3,000 sq. ft. require protection when
closer than 20 feet to the property line.
Parapets may be required.
ENGINEERED TRUSS OR
RAFTER SIZE AND SPA91p4G
/_i&
ROOFING MATERIAL
ROOFING PAPER
''12- 415
ROOF
THING
(DING
6" MIN.
1
24" MIN.
Si LID BLOCKING
L SHEATHING
� 14 Lk rZit,(c 4AI d Ti sr-
DOUBLE TOP PLATE
WALL HEIGHT
it
2x 0.C.
PRESSURE TREATED
SOLE PLATE
3-112' CONCRETE SLAB
S"x12"
FOOTING
ANGOR BOLTS
1/2"x7 MIN.
(7" INTO CONCRt I t)
6' 0. C. OR APPROVED
ANCHOR INSTALLED
PER MANUFACTURER
FOUNDATION PLAN
PLEA.`'E''DMPLETE THE FOLLO`' '''FORMATION AND ADD ON THE DRAWING BELOW.
/ / BUILDING DIMENSIONS: /9 X�C) '�
/ 1 i
GARAGE OPENING AND HE";"�DER SIZE: /c)(/0 0,4d0/
INDIn.ATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON THE PLAN.
f -
O
z
w
J
rT
R.1136E LIN:
0-
WIDTH
CONCRETE TO COMPLY TO IRC
N it/Codv4-
ABLE 404.1.1(1)
FOUNDATION WALLS - 3000 * PSI
SLABS, GARAGES, CARPORS
& PORCHES - 3500 # f1SI
ALL FOOTINGS MUST BE CON1IIINIJOUS
A
"7-"J
Please note that while every effort is made to assure the accuracy of the information contained in this brochure is
not warranted for accuracy. This document is not intended to address all aspects or regulatory requirements for a
project and should serve as a starting point for your investigation. For detailed information on a particular project,
permit, or code requirement refer directly to applicable file and/or code/regulatory documents or contact the
appropriate division.
Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4
vlin. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6
Vlin. 16, 18 or 20 in. APA Portal Frame Bracing
Engineered Shear Wall Bracing
tt4
t
0
`/
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
ROOF TRUSSES, BEAMS AND
FLOOR SYSTEMS PRIOR TO FRAMING
INSPECTIONS
CITY COPY
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
REV FOF 1J •
"-; .:PLANCFL: